ineve |LMe.Va. Spa. ~ Romania Nr. 241/13.08.2010 St. Virgil Madgear,25 Corp C ap 306 Sector | Bucharest Object: JV Astalt-PCC Bypass Constanta ‘Site Culvert Type Me. Va. Cumpana Km 141550 Dear Sirs, Please find here the calculation of estimation durability of stel galvanized culvert type LM. Va. INCOMING DATA ‘As por Testing report a” 108/13.04.2010 from S.C. RAJA S.A. Constanta Laborator Ape Potabila Palas (attached) we have the folowing INCOMING DATA concerning the water condition: pH pH 9.08 Conductivity S/om 168 equivalent o Resistivity $952.38 ohmem In conformity of “Handbook of Stee! Drainage and construction Product edition 1994, igure 6:7, ‘page 339 inthe ease of pHi > 7,3 we can calculate the durability according the following formal: Yoyears=2.94R™ In which R= 5952.38 ohmem And ‘¥=2,94"(6952,80)""=103,75 years Fortis reason in the case of stoel galvanized culverts thickness equal to 0052 inch (13mm) we Ihave a estimaied durability of 103,75 years. Best Regards A _— TMeVa.S.p.a. >> tae sea, 5.6. RAIA S.A. Constanta ‘rare anh Porn se rte Cy 24 mt RAPORY DEINCERCARE i. 108 18.00.2010 cod FLT Oe 0 ‘honda GaRTIRCKE De ACADIAN Nurse tenet Asocloren FCC CONSTRUCCCION SA & ASTALDI Sp. eas beefciuS. Paul Grezae 24 9p. 4,0, Boag Conan Contact 1424618. 0420107- ami ue ect Oa eco Localoclis/ sus: Cumpina Podet 14 +850 / Bata ‘Slandald rebovar: SRISO 56575:1057 Tp probs os pros A 7 Prada lca cores 18042010 (bsarvaf prclovare efoctuats de Donotcar;, data ina robe labora: 13.04.2010 Ronse © ase ctf tr wr | somiat comes | ‘igen taste | vile | rte ‘meee ape sticom | cma | ssa ees sea, Tat wait] SIRO 1608208 | SaaS 3 22% Hed eects 2 | a (y gt Seiso sear 2001 2 2 Moto wana 7 |__| | nai jin | ~ SR EN 2688007 2608 28% ei 4206 | Neos ecocins ac oot, once room hae on mncan rt 2 eng ca xy io cs ‘Rhuntc creas nna eevee ‘Eula at spn» ay ac i screen aa Feusrovettten Pout imhevs ICECON S.A, - $26, weania fife LMeVa. Spa. ~ Romania (Ne. 241/13.042010 Str. Vigil Madgearu, 25 Corp C ap.306 Sector I Bucurosti Obiectiv: JV Astaldi-FOC Bypass Constanta ‘Site Culvert Type LMe.Va. Cumpana Kan 144550 Stimate Domnule Presedinte ~ Director General Polidor BRATU, Prin prezonta va rugam sa ne comunicati durata de vata estimaia a strcturilor din tabla ondulata galvanizata ip LME.VA utilizat la obiectvel mai sus mentionst, in condtile precizate in raportal de incereare a ape me. 108/13.042010, emis de S.C. RAJA S.A. Constanta - Laborator apa potabila Palas (anexa!. 1m acelasi timp, anexam declratia producstoraui privind durabilitatea estimata a structurilor din tabla ondulatagalvanizata tip LME.VA. in conditile mentionate in aportl de inereare a apei. Cr ICECON S.A. Aa! Data ELE ® Ream een. . BEGUN 5.8. oon Reteritor la adresa dvs. nr, 241 din data 13.08.2010, prin care ne solicitat evaluarea durate de viata estimate a struturit du tabla ondulata galvanizata tip LME.VA - podet Cumpana Km 114550, va comunicam urmatoarele: In conditile preczate in raportul de incercare a apei nr. 108/13.04.2010, emis deS.C. RATA S.A. Constanta -Laborator apa potabila Pals, respect pul apei de 9,08 si conductvitatea ‘pei de 168 Siem (rezistionatea de 5.952,38 olm.em), rezuita o durata de viata estimata ‘Sructuilor dia tabla ondulatapalvanizata ip LME.V. de cca 103 ani, vloare care confirma

You might also like