You are on page 1of 2

AW 1200x1450

AW 1200x1810

AW 1200x2170

LINEN

ROBE

AW 1200x1810

ROBE

AW 1027x610

ROBE

AW 1200x1810

AW 1027x610

FIRST FLOOR

FW 1200x2170

AW 1200x1810

1.

Master Bed

4.2 x 4.0

2.

Bedroom 2

3.3 x 3.2

3.

Bedroom 3

3.3 x 3.2

4.

Bedroom 4

3.3 x 3.2

5.

Bedroom 5

3.2 x 3.3

6.

Living

5.3 x 5.6

7.

Dining

3.0 x 5.7

8.

Upstairs Living

5.5 x 5.0

9.

Garage

6.0 x 5.5

AW 514x2170

820

AW 1800x2400

AW 1800x850

AW 1800x850

7
2110x1465

SD 2110x3590

WIL
WM
SPACE

ROBE

5
P
FW 514x2170

GROUND FLOOR

2110x1485
AW 514x850

Sienna Building Pty Ltd - ABN 66 128 617 532 owns Copyright of this design any reproduction in whole or part without consent is forbidden
This Brochure is for illustration purposes only and should be used as a guide only. Refer to actual working drawings

AW 1800x2170

AW1027x1450

REF.
SPACE

Living Area

26.2 sq

Total Area

31.3 sq

Total House Length

17.42 m

Total House Width

11.30 m

Minimum Lot Width

12.50 m

UNLESS NOTED
OTHERWISE

DOUBLE POWER POINT @ 300MM.


SINGLE POWER POINT @ 750MM.
DOUBLE POWER POINT @ 1050MM.
WP

SGL WEATHER PROOF P.POINT @ 1050MM.

WP

DOUBLE WEATHER PROOF P.POINT @ 1050MM.


SGL P.POINT @ 600MM ON SEP. CIRCUIT.
SGL P.POINT TO CEIL-REMOTE CONT. UNIT
CEILING LIGHT OUTLET WITH ACRYLIC SHADE.
PENDANT LIGHT AS SPEC.

CEILING LIGHT WITH SPEC. FITTING.


LED (FIXED) DOWNLIGHT.
S.A.

2W

WALL LIGHT AS SPEC..


PARAFLOOD LIGHT WITH SENSOR.
1200 FLURO.
S

SENSOR.
EXHAUST FAN (SELF SEALING).

INSTALLED AS PER B.C.A. 3.8.5. &


TO COMPLY WITH A.S.1668.2.

COMBINATION EXHAUST FAN & LIGHT.


S.A.

SMOKE DETECTOR.

1300H
2W

TV POINT & DOUBLE POWER POINT @


SPECIFIED HEIGHT WITH BLOCKING
TV POINT

PH.

FIRST FLOOR

MMP
T-BOX

APPROX. POSITION INSTALLED AS PER


B.C.A. 3.7.2. & TO COMPLY WITH A.S.3786.

TO BE TERMINATED AT
ACCESS HATCH UNLESS SPECIFIED

TELEPHONE POINT TO MATCH ADJOINING POWER POINT HEIGHT


MULTIMEDIA POINT TO MATCH ADJOINING POWER POINT HEIGHT
TERMINATION BOX

D-HUB

DISTRIBUTION HUB BOX

DIM

DIMMER SWITCH TO FITTING AS WIRED.

2W

TWO WAY SWITCHING TO FITTING AS WIRED.

S/B

INTERNAL SWITCHBOARD.

M/B

EXTERNAL METER BOX.


HOT WATER UNIT AS SPEC'D.

GP

GAS BAYONET POINT @ 450mm

IMPORTANT:
- PROVIDE LIGHT POINT & SINGLE G.P.O. IN ROOF SPACE
- WHERE INSTALLED, PROVIDE DIRECT POWER OUTLETS TO COOK TOP,
RANGEHOOD, UNDER BENCH OVEN.
ALARM - WHERE SPECIFIED
ALARM SENSOR (TYP. WALL MOUNTED)

ALARM KEYPAD
ALARM STROBE & SIREN

ALARM CONTROL PANEL W/- SINGLE GPO @ 2200MM AFL


HEATING & COOLING - WHERE SPECIFIED
S.A.

2W

HTR

GAS DUCTED HEATING UNIT

ROOF ACCESS

CEILING REGISTER (HEATING ONLY)


CEILING REGISTER (COOLING ONLY)

ECU

CEILING FAN AS
SELECTED

RETURN AIR (WALL MOUNTED).

2W

EVAP. COOLER UNIT

RETURN AIR (CEILING MOUNTED).


AC - HEAD AIR CONDITIONER HEAD

PH.

DVS

GROUND FLOOR

DUCTED VACUUM SYSTEM


@1500MM APPROX.

DVP

AC - CON

DUCTED VACUUM POINT


@300MM

AIR CONDITIONER CONDENSOR


KO.

DUCTED VACUUM KICKBOARD OUTLET


(REFER INTERNALS FOR POSITION)

WP

Sienna Building Pty Ltd - ABN 66 128 617 532 owns Copyright of this design any reproduction in whole or part without consent is forbidden
This Brochure is for illustration purposes only and should be used as a guide only. Refer to actual working drawings

NOTE:
HEATING & COOLING REGISTERS INDICATED ON PLAN ARE SYMBOLIC ONLY. ACTUAL
REGISTERS SHAPE & LOCATION PER MANUFACTURES RECOMENDATIONS.

You might also like