Technical Data

Technical Data
Maximum air inlet pressure

Models with 16:1 - 70:1 pressure ratios: 100 psi (0.7 MPa, 7 bar).
Models with 80:1 pressure ratios: 90 psi (0.62 MPa, 6.2 bar).
Models with a 90:1 pressure ratio: 80 psi (0.55 MPa, 5.5 bar).

Air motor piston diameter

NXT Model 6500: 10.375 in. (264 mm)


NXT Model 3400: 7.5 in. (191 mm)
NXT Model 2200: 6.0 in. (152 mm)

Stroke length

4.75 in. (120 mm)

Air Inlet Size

3/4 npt(f)

Fluid Inlet Size

1-1/4 npt(m)

Fluid Outlet Size

All pumps with built-in filters (2 outlet ports): 1/2 npt(m)


Pumps without built-in filters (1 outlet port):
85cc and 115cc pumps: 1/2 npt(f)
145cc and 180cc pumps: 3/4 npt(f)
220cc, 250cc, and 290cc pumps: 1 npt(f)

Maximum pump speed


(Do not exceed maximum recommended speed of
fluid pump, to prevent premature pump wear)

60 cycles per minute

NOTE: See NXT Motor manual (311238) for sound data.

Maximum Working Pressure and Flow Rate at Full Air Pressure (100 psi)

Ratio

Maximum Working
Pressure psi (MPa, bar)

16:1
21:1

Flow Rate gpm (lpm)

NXT Air Motor

Lower
(cc per cycle)

30 cpm

60 cpm

1520 (10.5, 105)

2200

290

2.3 (8.7)

4.6 (17.0)

2025 (14.0, 140)

2200

220

1.74 (6.6)

3.4 (12.9)

24:1

2400 (16.5, 165)

2200

180

1.43 (5.4)

2.9 (11.0)

25:1

2375 (16.4, 164)

3400

290

2.3 (8.7)

4.6 (17.0)

30:1

3150 (21.7, 217)

3400

220

1.74 (6.6)

3.4 (12.9)

31:1

3000 (20.7, 207)

2200

145

1.15 (4.4)

2.3 (8.7)

35:1

3800 (26.2, 262)

2200

115

0.95 (3.6)

2.0 (7.6)

40:1

3800 (26.2, 262)

3400

180

1.43 (5.4)

2.9 (11.0)

45:1

4500 (31.0, 310)

6500

290

2.3 (8.7)

4.6 (17.0)

46:1

4750 (32.7, 327)

3400

145

1.15 (4.4)

2.3 (8.7)

50:1

5000 (34.5, 345)

6500

250

2.0 (7.6)

4.0 (15.2)

55:1

5600 (38.6, 386)

3400

115

0.95 (3.6)

2.0 (7.6)

60:1

6000 (41.7, 417)

6500

220

1.74 (6.6)

3.4 (12.9)

70:1

7250 (50.0, 500)

6500

180

1.43 (5.4)

2.9 (11.0)

80:1

7250 (50.0, 500)

3400

85

0.8 (3.0)

1.5 (5.7)

90:1

7250 (50.0, 500)

6500

145

1.15 (4.4)*

2.3 (8.7)*

* At 80 psi (0.55 MPa, 5.5 bar)


At 90 psi (0.62 MPa, 6.2 bar)

56

311164P

Pump Package Performance Charts

Pump Package Performance Charts


Calculate Fluid Outlet Pressure

Calculate Pump Air Flow/Consumption

To calculate fluid outlet pressure (psi/MPa/bar) at a specific fluid flow (gpm/lpm) and operating air pressure
(psi/MPa/bar), use the following instructions and pump
data charts.

To calculate pump air flow/consumption (scfm or


m3/min) at a specific fluid flow (gpm/lpm) and air pressure (psi/MPa/bar), use the following instructions and
pump data charts.

1. Locate desired flow along bottom of chart.

1. Locate desired flow along bottom of chart.

2. Follow vertical line up to intersection with selected


fluid outlet pressure curve. Follow left to scale to
read fluid outlet pressure.

2. Follow vertical line up to intersection with selected


air flow/consumption curve. Follow right to scale to
read air flow/consumption.

Key: Air Pressure


A
B
C

100 psi (0.7 MPa, 7 bar)


70 psi (0.5 MPa, 7.8 bar)
40 psi (0.3 MPa, 2.8 bar)

16:1 Xtreme Pumps

A
B

800
(5.6, 56)

60
(1.7)
40
(1.1)

B
C

400
(2.8, 28)

20
(0.6)

1.0
(3.8)

2.0
(7.6)

3.0
(11.4)

4.0
(15.2)

Fluid Pressure in psig (MPa, bar)

1200
(8.4, 84)

21:1 Xtreme Pumps


80
(2.2)

80
(2.2)

2500
(17.5, 175)

A
A
1500
(10.5, 105)

B
C

40
(1.1)

C
C

500
(3.5, 35)
0

1.0
(3.8)

2.0
(7.6)

Fluid Flow in gpm (lpm)

311164P

20
(0.6)

3.0
(11.4)

Fluid Pressure in psig (MPa, bar)

60
(1.7)

2500
(17.5, 175)

1500
(10.5, 105)

160
(4.5)

A
A

B
B
C
C

500
(3.5, 35)

1.0
(3.8)

3.0
(11.4)

120
(3.4)
80
(2.2)
40
(1.1)

Air Flow in SCFM (m3/min)

Fluid Pressure in psig (MPa, bar)

25:1 Xtreme Pumps


Air Flow in SCFM (m3/min)

1500
(10.5, 105)

3.0
(11.4)

Fluid Flow in gpm (lpm)

80
(2.2)

2.0
(7.6)

1.0
(3.8)

24:1 Xtreme Pumps

20
(0.6)

Fluid Flow in gpm (lpm)

2500
(17.5, 175)

40
(1.1)

500
(3.5, 35)

60
(1.7)

Air Flow in SCFM (m3/min)

1600
(11.2, 112)

Air Flow in SCFM (m3/min)

Fluid Pressure in psig (MPa, bar)

Dashed lines indicate low noise motors.

5.0
(19.0)

Fluid Flow in gpm (lpm)

57

Pump Package Performance Charts

31:1 Xtreme Pumps

30:1 Xtreme Pumps

120
(3.4)

2500
(17.5, 175)

1500
(10.5, 105)

80
(2.2)

40
(1.1)

500
(3.5, 35)
1.0
(3.8)

3.0
(11.4)

2.0
(7.6)

4.0
(15.2)

3000
(21.0, 210)

Fluid Pressure in psig (MPa, bar)

160
(4.5)

A
2000
(14.0, 140)

B
1000
(7.0, 70)

B
B

1000
(7.0, 70)

40
(1.1)

C
0.5
(1.9)

80
(2.2)

1.0
(3.8)

2.0
(7.6)

1.5
(5.7)

Fluid Pressure in psig (MPa, bar)

2000
(14.0, 140)

C
1.0
2.0
(3.8)
(7.6)
Fluid Flow in gpm (lpm)

3000
(21.0, 210)

2000
(14.0, 140)

150
(4.2)

B
C
C

1000
(7.0, 70)

1.0
(3.8)

50
(1.4)
3.0
(11.4)

Fluid Flow in gpm (lpm)

58

5.0
(19.0)

Fluid Pressure in psig (MPa, bar)

Fluid Pressure in psig (MPa, bar)

3000
(21.0, 210)

2000
(14.0, 140)

80
(2.2)

1000
(7.0, 70)

40
(1.1)

C
1.0
(3.8)

120
(3.4)

3.0
(11.4)

2.0
(7.6)

46:1 Xtreme Pumps


5000
(35.0, 350)
4000
(28.0, 280)
3000
(21.0, 210)
2000
(14.0, 140)

250
(7.0)

A
B
A
C
B

1000
(7.0, 70)
0

150
(4.2)

50
(1.4)

C
1.0
(3.8)

2.0
(7.6)

Air Flow in SCFM (m3/min)

Air Flow in SCFM (m3/min)

250
(7.0)

4000
(28.0, 280)

160
(4.5)

Fluid Flow in gpm (lpm)

45:1 Xtreme Pumps


A

3.0
(11.4)

40:1 Xtreme Pumps


4000
(28.0, 280)

Fluid Flow in gpm (lpm)

5000
(35.0, 350)

40
(1.1)

Air Flow in SCFM (m3/min)

3000
(21.0, 210)

120
(3.4)

Air Flow in SCFM (m3/min)

Fluid Pressure in psig (MPa, bar)

35:1 Xtreme Pumps

80
(2.2)

Fluid Flow in gpm (lpm)

4000
(28.0, 280)

120
(3.4)

Air Flow in SCFM (m3/min)

3500
(24.5, 245)

Air Flow in SCFM (m3/min)

Fluid Pressure in psig (MPa, bar)

Pump Package Performance Charts (cont.)

3.0
(11.4)

Fluid Flow in gpm (lpm)

311164P

Pump Package Performance Charts

Pump Package Performance Charts (cont.)

4000
(28.0, 280)

200
(5.6)

150
(4.2)

B
B

100
(2.8)

2000
(14.0, 140)

1.0
(3.8)

50
(1.4)

2.0
(7.6)

3.0
(11.4)

4.0
(15.2)

7000
(49.0, 490)

160
(4.5)

A
5000
(35.0, 350)

A
B
C

0.5
(1.9)

200
(5.6)

150
(4.2)

100
(2.8)

C
C
1.0
(3.8)

50
(1.4)

2.0
(7.6)

2.0
(7.6)

3.0
(11.4)

70:1 Xtreme Pumps

4.0
(15.2)

Fluid Pressure in psig (MPa, bar)

Fluid Pressure in psig (MPa, bar)

250
(7.0)

1000
(7.0, 70)

1.5
(5.7)

8000
(56.0, 560)
6000
(42.0, 420)
4000
(28.0, 280)

250
(7.0)

A
A
B

150
(4.2)

100
(2.8)

2000
(14.0, 140)

50
(1.4)

1.0
(3.8)

Fluid Flow in gpm (lpm)

200
(5.6)

2.0
(7.6)

Air Flow in SCFM (m3/min)

3000
(21.0, 210)

1.0
(3.8)

Fluid Flow in gpm (lpm)

Air Flow in SCFM (m3/min)

5000
(35.0, 350)

40
(1.1)

1000
(7.0, 70)

60:1 Xtreme Pumps

80
(2.2)

3000
(21.0, 210)

Fluid Flow in gpm (lpm)

7000
(49.0, 490)

120
(3.4)

Air Flow in SCFM (m3/min)

Fluid Pressure in psig (MPa, bar)

55:1 Xtreme Pumps


250
(7.0)

Air Flow in SCFM (m3/min)

Fluid Pressure in psig (MPa, bar)

50:1 Xtreme Pumps


6000
(42.0, 420)

3.0
(11.4)

Fluid Flow in gpm (lpm)

120
(3.4)

4000
(28.0, 280)

C
C

2000
(14.0, 140)

0.5
(1.9)

1.0
(3.8)

40
(1.1)

1.5
(5.7)

Fluid Flow in gpm (lpm)

311164P

80
(2.2)

2.0
(7.6)

90:1 Xtreme Pumps


8000
(56.0, 560)

250
(7.0)

B
B

6000
(42.0, 420)

200
(5.6)
150
(4.2)

4000
(28.0, 280)

100
(2.8)

2000
(14.0, 140)

1.0
(3.8)

50
(1.4)
2.0
(7.6)

Air Flow in SCFM (m3/min)

6000
(42.0, 420)

160
(4.5)

Fluid Pressure in psig (MPa, bar)

80:1 Xtreme Pumps


8000
(56.0, 560)

Air Flow in SCFM (m3/min)

Fluid Pressure in psig (MPa, bar)

Key: 90:1 Pumps Air Pressure


B 80 psi (0.56 MPa, 5.6 bar)
C 40 psi (0.28 MPa, 2.8 bar)

3.0
(11.4)

Fluid Flow in gpm (lpm)

59