Professional Documents
Culture Documents
ELECTRO-HYDRAULIC
LOW LIMIT
HIGH LIMIT
ACTUATOR
SPRING LOADED
HANDWHEEL
SINGLE SOLENOID
ACTUATOR W/ RESET
SINGLE SOLENOID
ACTUATOR
SIGNAL NAME
E/H
ACTUATORS
DIAPHRAGM ACTUATOR
DIAPHRAGM ACTUATOR
W/ ELECTRO-PNEUMATIC
POSITIONER
PRESSURE BALANCED
DIAPHRAGM ACTUATOR
SINGLE ACTING
CYLINDER ACTUATOR
DOUBLE ACTING
CYLINDER ACTUATOR
MOTOR ACTUATOR
-K
REVERSE PROPORTIONAL
VELOCITY LIMITER
BIAS PLUS
BIAS MINUS
CONVERSION
INPUT/OUTPUT
BIAS PLUS/MINUS
*/*
REVERSE ACTION
DIRECT ACTION
REV
DIR
ANALOG
PNEUMATIC
ELECTROMAGNETIC SIGNAL
CURRENT
d/dt
LOW SELECT
* =
ON-OFF
BINARY
RESISTANCE ELECTRICAL
1-O
DIGITAL
PROPORTIONAL INTEGRAL
DERIVATIVE
VOLTAGE
TIME FUNCTION
UNSPECIFIED
EXPONENTIAL
ROOT EXTRACTING
DIVIDE
MULTIPLY
DERIVATIVE
INTEGRAL
PROPORTIONAL
DIFFERENCE
AVERAGE
SUM
d/dt
f(x)
f(t)
HYDRAULIC
HIGH SELECT
A
B
PITOT TUBE
FLOW NOZZLE
WELL
UNCLASSIFIED
MULTIFUNCTION
RECORD
CHEMICAL SEAL
ORIFICE PLATE
FLUME
WEIR
VENTURI TUBE
POSITIVE DISPLACEMENT
FLOW INSTRUMENT
VARIABLE AREA
FLOW INSTRUMENT
WATER GAUGER
SUCCEEDING LETTER
USER'S CHOICE
ORIFICE, RESTRICTION
LIGHT
INDICATE
USERS CHOICE
ALARM
UNCLASSIFIED
SWITCH
TRANSMIT
MULTIFUNCTION
VALVE, DAMPER, LOUVER
USER'S CHOICE
CONTROL STATION
PANEL AND CABINET
CONTROL
USERS CHOICE
06TIC-000A
AREA NUMBER
MEASURED VARIABLE LETTER
MODIFIED LETTER
FUNCTION LETTER
MODIFIER
FIRST LETTER
MEASURED OR INITIATION VARIABLE
SAFETY
INTEGRATE, TOTALIZE
MOMENTARY
SCAN
TIME RATE OF CHANGE
DIFFERENTIAL
RATIO, FRACTION
HAND
CURRENT (ELECTRICAL)
POWER
ANALYSIS
BRIX
BURNER,COMBUSTION
CONDUCTIVITY
DENSITY
VOLTAGE
FLOW RATE
C
D
E
F
G
H
I
J
LEVEL
MOTOR
MOISTURE
L
M
USER'S CHOICE
USER'S CHOICE
PRESSURE, VACUUM
N
O
P
QUANTITY
RADIATION
TEMPERATURE
MULTIVARIABLE
VIBRATION
MECH. ANALYSIS
VISCOSITY
WEIGHTFORCE
UNCLASSIFIED
EVENT, STATE OR PRESENCE
SPEED, FREQUENCY
W
X
Y
POSITION, DIMENSION
Q
R
S
T
U
V
MODIFIER
USERS CHOICE
CLOSED
HIGH
LOW
MIDDLE, INTERMEDIATE
USERS CHOICE
OPEN
MULTIFUNCTION
UNCLASSIFIED
001
INSTRUMENT SYMBOLS
LOCALLY MOUNTED
INSTRUMENT SHARING COMMON HOUSING
INSTRUMENT LOCAL GAUGE BOARD MOUNTED
INSTRUMENT LOCAL PANEL MOUNTED
INSTRUMENT CONTROL ROOM PANEL
OR RACK MOUNTED
6.01
TIR
SP
TSO
LO
LC
LL
IA
HH
FC
FI
FL
FO
SET POINT
LOCK OPEN
LOCK CLOSE
LOW ALARM
HIGH ALARM
FAIL
FAIL
FAIL
FAIL
AREA NUMBER
SEQUENCE NUMBER
IDENTIFICATION LETTERS
PILOT LIGHT
PILOT LIGHT MOUNTED ON
PANEL IN CONTROL ROOM
PILOT LIGHT MOUNTED ON
LOCAL PANEL
AREA NUMBER
IDENTIFICATION LETTERS
SEQUENCE NUMBER
(F)
X-R
INSTRUMENT ABBREVIATIONS
XR
-R
CLOSED
INTERMEDIATE
LOCKED
OPEN
GENERAL NOTES