DRT Scanner

Quick Guide for XCAL-LTE


(Rev 071610)

Operation and Setup

Description
Power On/Off
Unit is powered on by connecting the power cable and power off by disconnecting
power cable
Control Interface
The unit maybe connected directly to a PC through and Ethernet crossover cable.
When directly connected to a PC the unit must be setup using a static IP address a
nd the PC must also be configured with a static IP address
address.

Network Connection Setting


1.Check your network connection for Ethernet port which was connected to laptop.
2. Set PC static IP address to 192.168.5.1
Please make sure yyou are able to ping
p g scanner IP address: 192.168.5.2
Ping reply messages represent connection has been established

Port Setting
1. Check Scanner button
2. Click Alias Setting button
3. Type Interface name and select Scanner Type
* Available scanner List will be shown in List box when y
you click Find Scanner button

4. Add your Interface name on Alias list


5. Click OK button and return to Port setting window.

New Task
1. If Scanner H/W is successfully synchronized with XCAL-LTE then you can
see New Task button become to Enable status
* Scanner 1 section on the left bottom side of XCAL main window would changed
g its color to Blue.

2. Click New Task button

RF Setting

1. Select Protocol , Task Type, Band


2. Select Channels to Scan
You can easily convert Channel index to actual
Frequency(Hz) via Channel to Freq. Converter

Data Measurement Setting

1. Select Data Measurement tab


2. Set Measurement Enable list
3. Set Scan Configuration
4. Set PSCH Detect Threshold
5. Set SSCH Detect Threshold
6. Set RS Detect Threshold

Scanner parameters
MeasurementEnable:
RS:RSRP(dBm),RSRQ(dB) WhenthisboxischeckedtheReferenceSignalReceivedPowerandReferenceSignalRec
eivedQualitywillbeincludedinthemeasurement
DetectionMode
D
i M d
ASYNC Detectionisattemptedwithoutattemptingtosynchronizingtothedownlinksignal
SYNC DetectionisperformedfollowingthesynchronizationofthedownlinksignaltoaknownstandardsuchasGPS
Robust Whenworkinginanenvironmentwithincreasednoiseandinterference,Robustmodewillimprove
detectionbyperformingamoredetailedanalysisofthesignal.RobustmodeisslowerthanASYNCortheSYNC
yp
g
y
g
Modes.
NumberofTXAntennas Specifiesthenumberoftransmitantennasbeingusedbythebasestation
ObservationtoAverage Thenumberofobservationsthatmustbedetectedbeforereportingthechannel.
PSCHDetectThreshold ThesignallevelbelowwhichthePrimarySynchronizationChannel(PSCH)decodeddataisnotretu
rned.ThisthresholdisenabledwhenMeasurementEnable,SCHisselected,otherwiseithasnoeffect.Thedefaultvalue
forthissettingis 10dB
SSCHDetectThreshold ThesignallevelbelowwhichtheSecondarySynchronizationChannel(SSCH)decodedataisnotret
urned.ThisthresholdisenabledwhenMeasurementEnable,SCHisselected,otherwiseithasnoeffect.Thedefaultvalue
is6dB
RSDetectThreshold
RS
Detect Threshold ThesignallevelbelowwhichtheRSdecodeddataisnotreturned.ThisthresholdisenabledwhenM
The signal level below which the RS decoded data is not returned This threshold is enabled when M
easurementEnable,RSisselected,otherwiseithasnoeffect.Thedefaultvalueforthissettingis20dB.
7

PCI Setup

1. Select PCI tab


2. Set Filtering section
TopN Value only available when you select your
filtering mode to TopN

PCI Setup
FilteringMode Selectsthetypeoffilteringtobeusedfordecoding.TopN returnsuptoNsetsofdata
whereNisthenumberenteredintheTopN Valuefield.
TopN Value Themaximumnumberofdatasetsthatwillbereturned.Thelargestentryis127.
PCI AllowsyoutoselectthePhysicalLayerCellIdentity(PCI)
PCIGroup AllowsyoutoselectthePCIGroup.
Count Thenumberofpairsintheunlabeledsearchfield
Unlabeledfield ThisfieldcontainsthePCI/PCIGrouppairsthatwillbesearchedforduringthesurvey.Only
dataonthesepairswillbereturned.Thisfieldcanhaveamaximumof127pairs.

Save/Load Setting

1.
2.
3.

You can save/load your setting at any Tabs you


choose.
Save setting will save whole settings in RF,
Data Measurement,, PCI Setup
p tab/
To apply whole settings, Click OK button

10

Start Scan
1. Click Play Icon to start measurement
* To stop measurement and terminate task, click Stop Icon and Exit button
* You can select Key parameters what you want to see in the red marked list box

2. Click Bar graph to check detail measurement result for corresponded PCI

11

Thank You

Accuver : Accurate + Verified in Test and Measurement Equipment


www accuver com
www.accuver.com