You are on page 1of 1

DATA FLOW DIAGRAM PEG GUANACASTE ENERGY MEASUREMENT

As-Is situation (February 2012)


Data

Measurement
Equipment

Unit

Data
Collection
Application

Unit

Data registration
and storage

Data Handling and


Reporting System

Unit

Control
Application
Daily Values

Unit

Control
Application
Monthly
Values

Unit

Injected Energy to the Grid 230kV

Primary Data

Spreadsheet Monthly
Report)

15' AActive (Export to Grid)

Main
Energy
Meter
230kV

1011
0100

kWh

1011
0100

kWh

YYYY-MM Energa
Entregada.xls

Spreadsheet files
Extracted data from
ION 7550 devices

copy/
paste

15' A-

kWh

Active (Export to Grid)

Stored on server

A-

Active (Export to Grid)

15' AActive (Export to Grid) Backup

Backup
Energy
Meter
230kV

ION 230 Y 345 PRINCIPAL Y


RESPALDO - AYER
(YYYY-MM-DD HH
MM SS).xls
1011
0100

kWh

1011
0100

A-

Active (Export to Grid)

kWh

copy/
paste

kWh

copy/
paste

copy/
paste

kWh

copy/
paste

kWh

A-

A-

Active (Export to Grid)

Active (Export to Grid)

15' NA-

kWh

Active (Export to Grid) Backup

D NA-

ION
Enterprise
Software

Active (Export to Grid) Backup

M NAActive (Export to Grid) Backup

A-

Active (Export to Grid) Backup

kWh

copy/
paste

A-

Active (Export to Grid) Backup

Energy consumption ICE substation

(Daily Request
for Raw Data
00h00)

15' AActive (To Substation)

Main
Energy
Meter
34,5kV

1011
0100

kWh

1011
0100

kWh

copy/
paste

15' A-

kWh

Active (To Substation)

A-

Active (To Substation)

copy/
paste

kWh

A-

Active (To Substation)

15' AActive (To Substation) Backup

Backup
Energy
Meter
34,5kV

1011
0100

kWh

1011
0100

kWh

copy/
paste

Active (To Substation) Backup

A-

Gross Production

S1 to S55

Gross Active

55x Gross
Energy
Meter

1011
0100

SCADA
Enercon
1011
0100

kWh

Stored on server

Own consumption PEG

kWh Control =

kWh

copy/
paste

D GA-

D A+*

Energy
Meter

kWh

S1 to S55

Gross Active

M GA-

S1 to S55

Gross Active

copy/
paste

kWh

copy/
paste

kWh

M GA-

S1 to S55

Gross Active

% Losses
(Transformers + cables

55

k=1

Active PEG (Cons.) *=index reading

Monthly Operation
Report
(YYYY-MM Informe
Mensual OP PEG.xls
Sheet: CDM Data)
Primary Data
Secondary Data
CDM Data

Filename:
Query WsAd
Daily_3060.csv

Manual Index
registration
form
(hardcopy)

A-

Spreadsheet files
Extracted data SCADA
Enercon

kWh

D GA- S1 to S55
Gross Active

Active (To Substation)

YYYY-MM Daily
Control mechanism Main data and
Secondary data.xls

Active (To Substation) Backup

GA-

kWh

A-

real
time

copy/
paste

Control Application
Daily values
(Spreadsheet)

15' A-

kWh

A-

Active (To Substation)

Active (To Substation) Backup

Secondary Data

A-

Active (To Substation)

kWhk,Gross

) kWh

PEG consumption

kWh ICE substation consumption

* 1-

% Losses
100

kWh

A-

Active (Export to Grid) Control

A+

Active PEG (Consumption)

A+

Active PEG (Consumption)

A+

Active PEG (Consumption)

Control Mechanisms:
Deviation (%) = (A - B) / A

* 100

1: Compare A with B

Deviation (%) = (A - C) / A

* 100

2: Compare A with C

% Losses
(Transformers + cables

A-

Active (Export to Grid) Control

Data from Sales Receipts


and Invoices

Primary Data

kWh Control =

A-

Active (Injected Sales Receipt)

A+

Electricity
Sales
Receipt ICE

Invoice ICE

Active (Received Invoice ICE)

55

kWhk,Gross
k=1

) kWh

PEG consumption

kWh

kWh

kWh ICE substation consumption

* 1-

D
% Losses
100

A-

Active (Injected, Sales Receipt)

A+

Active (Received, Invoice ICE)

NA-(From invoices) (kWh) = A-(injected) A+(received)

M NANet Active (From invoices)

Injected Energy to the Grid 230kV

Primary Data

Monthly Data Control:


Compare monthly value
(kWh Month control = kWh Day1 (M+1) 00h00 kWh Day1 (M) 00h00 )
15' AActive (Export to Grid)

15' A+
Active (Import from Grid)

Main
Energy
Meter
230kV

With:
1011
0100

kWh

1011
0100

kWh

1011
0100

kWh

1011
0100

kWh

kWh

1) Monthly value from YYYY-MM Energa Entregada.xls


kWh

NA-(main) (kWh) = A-(export to grid) A+(import from grid)

15' AActive (Export to Grid) Backup

15' A+
Active (Import from Grid) Backup

Backup
Energy
Meter
230kV

1011
0100

kWh

1011
0100

1011
0100

kWh

1011
0100

ION
Enterprise
Software

kWh

Spreadsheet file
Extracted data from
ION 7550 devices

kWh

Legend

Stored on server

Energy consumption ICE substation

(Monthly
Request for
Raw Data)

15' AActive (To Substation)

Main
Energy
Meter
34,5kV

15' A-

real
time

A+

Active (Import from Grid) Backup

NA-(backup) (kWh) = A-(export to grid backup) A+(import from grid backup)

Real-time

M NANet Active (Inj. to Grid) Backup

W Week
M Month
Y Year
X' X minutes

1011
0100

kWh

1011
0100

kWh

Source

Control Mechanisms:

Project Site
Grid Operator
X Constant Value
S1 System1: Generator 1

Deviation (%) = (A - B) / A

* 100

1: Compare A with B

Deviation (%) = (A - C) / A

* 100

2: Compare A with C

Deviation (%) = (A - D) / A

* 100

3: Compare A with D

S2 System2: Generator 2

Active (To Substation) Backup

M NANet Active (Injected to Grid)

D Day

ION 230 Y 345 PRINCIPAL Y


RESPALDO - ULTIMO
MES (Month YYYY).xls

System

Backup
Energy
Meter
34,5kV

A+

kWh

Timestamp

Secondary Data

Active (Import from Grid)

S55 System55: Generator 55


1011
0100

kWh

1011
0100

kWh

Signal/Data

1011
0100

Digital Communication Protocol

copy/
paste

Manual Copy/Paste

Manual input

You might also like