If you are not sure how accurate your digital multimeter measurement is, find its accuracy specifications in the
instruction manual, and then read this to get the rest of the story.

Design Engineering Updates

Most hand-held DMMs are more accurate than you might expect, including the least
expensive models.In addition to volts, ohms, and amperes, many can also measure frequency
and capacitance.

The accuracy of an electronic measurement defines how close the indicated value is to the true value of the measured
signal. Analog meters usually have their accuracy listed as a percentage of the full-scale reading. When a measured
value is close to full scale, or at least above 2/3 of full scale, the published accuracy is meaningful. However, the
further away the reading is from full scale, the greater it can deviate from the true value when viewed as a percentage
of reading, not as percentage of full scale.

http://www.designworldonline.com/howtodeterminedigitalmultimeteraccuracy/#_

1/5

11/6/2015

HowtoDetermineDigitalMultimeterAccuracy

For example, an analog voltmeter with a 3% accuracy is set to the 0 to 100-V range. Based on this accuracy, its
pointer can be 3 volts (100 V x 0.03 = 3V) below or above the true reading. If the true measured value is, for example,
90.0 V, the meter might read between 87 V and 93 V or 3.3% of reading. However, 10.0volts measured on a 100-V
scale of the same voltmeter can read between 7 V and 13 V, or 30% of the actual reading, while the meter is
technically within specifications. So, to maintain reasonable accuracy, select the analog meter range that places the
pointer between 2/3 of full scale and full scale.
Compared to analog meters, digital multimeters (DMM) have many practical advantages. They present measurement
data in a direct format that does not require calculating the exact value, and they are free from the parallax error of
analog meters. Unlike meter movements in analog meters, digital multimeter displays have no moving parts, and they
are free from wear and shock failures. DMMs automatically detect polarity, show positive and negative values, have
much better overload protection, and offer automatic as well as manual range selection options.

Design World Digital Edition


Browse the most
current issue of Design
World and back issues in
an easy to use high
quality format. Clip,
share and download
with the leading design
engineering magazine today.
ViewBackIssues

Subscribe

All these features lead many DMM users to believe that because the meter displays the measured value in direct
decimal format the number shown is the true value of the measured parameter. Others read the meter manual to find
the basic accuracy specifications, for example 2%, and expect all readings to be within this margin of error. However,
to calculate the actual deviation from the true value that the meter manufacturer can claim and still be within
specifications requires a much deeper understanding of the published electrical meter specifications. For example,
first, look at how DMM resolution and ranges affect accuracy, then read the examples that follow and learn what the
meter manufacturers really mean.
Display digits, DMM counts, and resolution
Most hand-held DMMs have a so-called 3-digit display. The three full numeric characters on the right can show any
value from 0 through 9, but the leading (most significant) digit can be only 0 or 1, and is called the digit. Such
meters can display numbers from 0 to 1999. They are also known as 2000-count DMMs.
DMM resolution depends on the maximum number of analog-to-digital converter (ADC) counts during a full
conversion. For example, the theoretical resolution of a 2000-count meter with a 3-digit display is (1/2000)(100%) =
0.05%. However, a practical resolution also accounts for the number of least significant counts similar to the
accuracy rating.

The most accurate reading for an analog meter is a pointer position between 2/3
of full scale and full scale.

Typically, dc voltage measurements use the full count capability of the ADC, since signal conditioning is rather straight
forward: it uses resistive dividers and filters. Other functions might be limited in range or require signal conditioning
that limits the ADC input range and gives a coarser resolution. High resolution, hand-held DMMs often have a 4-digit
display (20000 count) and can display any value from 0 to 19999. The 40000-count meters have a 4-digit display and
can represent any value from 0 to 39999. Somewhere in the middle are 3-digit displays or 4000-count DMMs. Many
DMMs temporarily blank the leading digit when it contains a zero.
The larger number of counts should translate into higher resolution, and usually DMMs with a higher resolution have
higher accuracy. However, DMM accuracy also depends on other design factors, such as ADC accuracy, component
tolerances, noise level, and the stability of internal references. So, do not automatically assume that a 4-digit meter
is 10 times more accurate than a 3-digit meter. In addition, since DMMs have automatic polarity detection, they
display negative values equal in range to the positive values. That is, the display of a 3-digit DMM can show any
number from -1999 to 0 and from 0 to 1999.

Forum for Electronics


Covering Microcontrollers, DSP, Networking,
Analog and Digital Design, RF, Power Electronics,
PCB Routing and much more

Ranges
Select the highest range first to keep the meter safe from damage, then switch to progressively lower ranges to
obtain the most accurate measurement available on a given meter. Range selection on the least expensive DMMs is
usually manual: the user sets the rotary switch to the appropriate range of the desired function. For example, a typical
selection of available ranges in dc volts of a 3-digit DMM will include 200 mV, 2 V, 20 V, 200 V, and 1000 V (or some
lower value). The top range is limited by the maximum voltage that the meter can safely handle.
For manual range-changing meters, switch to a range that provides the maximum number of digits for the unknown
voltage. For example, when measuring a 1.5-V battery, the highest 1000 V range will only show 1. Switching to the
200 V range will show 1.5 on the display, the 20-V range could display 1.52, and the most accurate reading is obtained
in the 2-V range: perhaps 1.523. This will become more obvious in the following section on DMM accuracy.
DMM accuracy
Some instruction manuals list basic meter accuracy as % of reading. For example, if the basic meter accuracy in the
dc volts range is 1%, and the true voltage is 1.00V, the meter is expected to display a reading of 1.00 V 1%, or 0.99
V to 1.01 V. However, basic accuracy does not take into account the inner workings of the ADC (that is at the heart of

http://www.designworldonline.com/howtodeterminedigitalmultimeteraccuracy/#_

2/5

11/6/2015

HowtoDetermineDigitalMultimeterAccuracy

every DMM) and other circuitry on the analog side. These circuits and the ADC have tolerances, nonlinearities, and
offsets that vary from function to function. In addition, signal noise might require limiting the resolution. To give
meter users a more accurate value, DMM manufacturers present accuracy specifications in the following format:
Complete accuracy specifications: (% of reading + number of LSD)
Where:
Reading = the true value of the signal that the DMM measures
LSD = least significant digit
The LSD represents the magnitude of uncertainty due to internal offsets, noise, and rounding errors. For a given DMM
the number of LSDs varies from function to function and even from range to range for the same function. Accuracy
and range selection need to be considered independently, otherwise a misunderstanding can lead to gross errors. For
example, consider the following:
A 3-digit display DMM measures an output of a precision 1.2-V reference. Presume that the true voltage is 1.200 V.
The DMM manual shows the dc volts accuracy specification as (0.5% + 3). How should you measure the voltage and
interpret the reading?
First, set the meter to the 200-V range. The display will indicate the measured voltage as XX.X. The percentage of
reading is (1.200)(0.5)/100 = 0.006 V, which cannot even be seen on the display because only one digit after the
decimal point is shown. However, when accounting for the three allowed LSD counts, realize that the last digit on the
display can vary by 3 counts. So, the meter can display a value of 1.2 0.3 V, or a range of 0.9 V to 1.5 V. This is a
25% potential error with all factors combined and is not acceptable for a precision measurement.

The Engineering Exchange is a global educational


networking community for engineers.
Connect, share, and learn today

Tweets

Follow

Design World
@DesignWorld

6h

Bearing FAQ you need to know: How does


internal clearance differ after mounting a
bearing?
hubs.ly/H01mDjP0 pic.twitter.com/ohDiP4lDSs

Set the switch to the 20-V range and it will display the value as X.XX, which improves the accuracy. The complete
accuracy can be a calculated as (1.200)(0.5)/100 +0.03) = 0.036 V. So, any reading between 1.16 V and 1.23 V is
within the accuracy specifications. This complete accuracy is 3% of reading, which is better, but still not accurate
enough.
Finally, set the DMM to the 2-V range. The display format changes to X.XXX. The percentage of reading does not
change, but the third LSD becomes a smaller factor. The complete accuracy can be a determined as (1.200)(0.5)/100
+0.003) = 0.009 V. The meter display is only allowed to be within the narrow 1.191 V to 1.209 V range. Now the
complete accuracy is only 0.75% of reading, which is sufficient for the measurement. So, selecting the lowest
measurement range before the DMM over-ranges reduces the negative effect of the number of LSDs and gives the
most accurate results.
Time, temperature, and humidity
When was your meter manufactured or recalibrated? Most meter manufacturers and calibration services guarantee
accuracy specifications only for one year. After that, the DMM might not keep its accuracy within published limits. So,
if accuracy must be guaranteed, the meter must be calibrated about once a year.

Tweet to @DesignWorld

DesignWorldNetwork
394,912likes

LikePage

SignUp

Bethefirstofyourfriendstolikethis

DesignWorldNetwork
15hrs

Myth1:ISO13849andIEC61508are
laws

5mythsaboutsafetyin
machinery
Safetyhasbeenahottopicin
automationandmotioncontroland
The most accurate reading for a digital meter is in the
lowest range that shows the most significant digit in the
left-most position. Select the lowest measurement range
on the DMM before it over-ranges to read the most
accurate results. For example, in the first figure, a DMM
reads an unknown low voltage (which appears to be 1.4 V)
as displayed on the 200-V dc range. Initially, the reading
looks acceptable. However, switching to the 20-V dc range
improves the accuracy; the reading is now 1.58 V because
the least significant digit (LSD) error is pushed into the
hundredths of a volt position. Finally, after switching the
DMM to the 2-V dc position, the reading is 1.602 V. It then
becomes obvious how the LSD counts can become a more

http://www.designworldonline.com/howtodeterminedigitalmultimeteraccuracy/#_

WWW.MOTIONCONTROLTIPS.COM

34Likes12Shares

Design World
Ikuti

+1

+ 2.646

3/5

11/6/2015

HowtoDetermineDigitalMultimeterAccuracy
becomes obvious how the LSD counts can become a more
significant source of error than the accuracy when the
range selection is not considered.

Do not use the meter when the ambient temperature is higher or lower than the specified operating temperature
range. In addition to the operating temperature specifications of electronic components inside the meter, LCD
displays are notorious for becoming sluggish and eventually going blank at subfreezing temperatures. At high
temperatures, LCDs display ghost images of the segments that are turned off, and they eventually darken.
Many high-quality DMMs produced by major manufacturers have an operating temperature range of20C to +55C.
This wide temperature range guarantees that the meter will perform reasonably well under most indoor and outdoor
conditions. However, beware of inexpensive meters: many are guaranteed to work reliably only between 0C and
+40C. In any case, these specifications are true only when the relative humidity is below a specified value, usually 80
to 90%.
Do not confuse the operating temperature with the temperature range at which the manufacturer specifies meter
accuracy.
Compared to the 20C to +55C operating temperature range,accuracy specifications are normally guaranteed only
within a much narrower 18C to 28C (235C) range and often at a lower humidity level. Some meter specifications
list a temperature coefficient value that helps calculate the accuracy of a specific function for the entire operating
temperature range. A typical example of a temperature coefficient would be 0.05 times (specified accuracy) per each
C between 20C and 18Cand from 28C to +55C. However, do not assume that every meter will have the same
temperature coefficient. If the meter manual does not list it, the loss of accuracy due to ambient temperature
fluctuations might be much higher. Also, the effect of humidity increases at a higher temperature.
Discuss this on the Engineering Exchange:

For more information:


http://www.fluke.com
http://www.omega.com
http://www.tek.com
http://www.agilent.com
http://www.ul.com
http://www.nist.gov

0Comments
Recommend

DesignWorld

Share

Login

SortbyBest

Startthediscussion

Bethefirsttocomment.

Subscribe

AddDisqustoyoursite

Privacy

http://www.designworldonline.com/howtodeterminedigitalmultimeteraccuracy/#_

4/5

11/6/2015

HowtoDetermineDigitalMultimeterAccuracy

Solar Power

Windpower

Print Subscription

Design World

Solar Power World reaches executives,

Windpower Engineering & Development

Stay Informed. Stay Smart. Stay Ahead.

>> Advertising

managers, engineers, installers and

covers the design, technical content, and

You're invited to qualify for the fastest

>> Contact

technical professionals involved in the

maintenance of wind turbines, wind farms,

growing design engineering publication on

design, manufacturing, development, and

and the regulations and policies that make

the market today. Click button below for

>> Engineering Jobs

installation of solar power projects.

the industry function.

additional information.

Visitwebsite

Visitwebsite

New/ManageSubscription

>> RSS
>> Enews Archive
>> Site Map

Privacy Policy. Copyright 2015 WTWH Media, LLC. All Rights Reserved.

http://www.designworldonline.com/howtodeterminedigitalmultimeteraccuracy/#_

5/5

You might also like