Professional Documents
Culture Documents
Office:
Author:
Date 10/17/2015
Project Name:
Slab design
Assumptions
Calculation mode: Composite Floors
Dimensioning of reinforced concrete slab on the profiled steel sheets that work together in the service
(composite) phase, partially or completely replace the bottom reinforcement in service (composite) phase and
are used as a working platform and formwork in the construction phase.
ArcelorMittal
Type:
0.75 mm
1.2. Reinforcement
Steel grade:
Self weight:
77,01 kN/m3
d1 = 10 mm
d2 = 10 mm
c1 = 20 mm
c2 = 20 mm
1.3. Concrete
Concrete class:
Self weight:
25 kN/m3
1.4. Assumptions
Calculations according to the code:
EN 1993-1-3
EN 1993-1-1
EN 1994-1-2
National Annex:
User
L / 180
h = 9 cm; bs = 150 mm; bb = 124 mm; b0 = 103.5 mm; br = 46.5 mm; hp = 40 mm; hc = 50 mm
Moment of inertia of a section: I = 452.49 cm4/m
1.6. Load
Span:
Self-weight:
Dead load:
Live load:
3.00 kN/m2
5.54 kN/m2
3.00 kN/m2
Safety factors
Self-weight:
1.35
Dead load:
1.35
Live load:
1.50
1.00
Value (kNm/m)
23.06
Value (kNm/m)
Value (kN/m)
- /23.06
-23.06 / -
Value (kN/m)
29.18
2. Diagrams
3. Slab design
The slab is designed incorrectly
Anti-shrinkage reinforcement
Amesh = 188 mm2 > As2min = 152 mm2 (81%)
4. List of materials
The amount of reinforcing steel (upper bars):
Q188 (#6x15)
3.58 kg/m2
d1 = 10 mm
4.03 kg/m2
C25/30
0.13 m3/m2