12:12 PM 05/04/2011

CLIENT: SAC
LOCATION: Kuwait
UNIT: EOCENE TRANSFER LINE
VERSION 1.4 PRESSURE DROP CALCULATIONS
LINE NO: 16"
FROM : Shipping Pump
TO : Tank
init psig
150
Deg F
100
lbs/hr
554,142
bbsd
40103
gpm
1169.67
lbs/cf
59.07
visc. (cps)
115
pipe I.D.
Nom Pipe Size
pipe Sch
area(sf)
f/s

15.25
16
40
1.268
2.05
LAMINAR

Psi/100'
NRe
A
B
f
epsilon

0.068
1.99E+3
3.51E+17
2.30E+20
0.0321
0.0001

straight length
elbows
straight tee
branch tee
gate valves
check valves
reducer
entrance

170560
0
0
0
6
1
0
0

exit
other
Equiv. length

0
0
170827

line drop(psi)
exch/eq drop
fe/fo/meter
furnace loss
frictional drop

115.924
10
0
0
125.924

control valve
st hd gain(ft)
st hd (psi)
outlet psig
last exported

0
510
209.21
233.28

JO-1495
ACEC