You are on page 1of 6

IES INDOOR REPORT

PHOTOMETRIC FILENAME : BALA LED CETUS RA OP 10W.IES


DESCRIPTION INFORMATION (From Photometric File)
IESNA:LM-63-2002
[TEST]20131212-3
[TESTLAB] AD973
[TESTDATE]12-12-2013
[EQUIPMENT]PHOTOGLOBE II
[MANUFAC] CELSA S.A.
[LUMINAIRE] CETUS RA OP 10W
[LUMCAT] BALA LED
[LAMP]MODULO VOSSLOH LUGA 10430
[BALLAST] LPF-60D-48
[ISSUEDATE]12/12/2013
[OTHER] INDICE DE REPPRODUCCIN DEL COLOR:60 %
[OTHER]TEMPERATURA DEL COLOR: 3873 K
[OTHER] LABORATORIO DE ILUMINACION PHOTOGLOBE II CELSA S.A
[OTHER] Calle 50 No. 40-20 Itagui-Colombia
[OTHER] Tel +574 3755500
[OTHER] Fax +574 3721707
[OTHER] www.celsa.com.co
[OTHER] mail: info@celsa.com.co
CHARACTERISTICS
Lumens Per Lamp
Total Lamp Lumens
Luminaire Lumens
Total Luminaire Efficiency
Luminaire Efficacy Rating (LER)
Total Luminaire Watts
Ballast Factor
CIE Type
Spacing Criterion (0-180)
Spacing Criterion (90-270)
Spacing Criterion (Diagonal)
Basic Luminous Shape
Luminous Length (0-180)
Luminous Width (90-270)
Luminous Height

846 (1 lamp)
846
848
100 %
85
10
1.00
Direct
1.18
1.18
1.20
Rectangular w/Sides
0.10 m
0.10 m
0.10 m

Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc.


Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.

Page 1

IES INDOOR REPORT


PHOTOMETRIC FILENAME : BALA LED CETUS RA OP 10W.IES
LUMINANCE DATA (cd/sq.m)
Angle In
Degrees

Average
0-Deg

Average
45-Deg

Average
90-Deg

45
55
65
75
85

14431
10609
6548
3225
383

11955
8531
5106
2431
277

14431
10609
6548
3225
383

Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc.


Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.

Page 2

IES INDOOR REPORT


PHOTOMETRIC FILENAME : BALA LED CETUS RA OP 10W.IES
CANDELA TABULATION

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90

0
367.540
365.913
331.940
326.085
326.337
316.019
286.761
251.526
203.841
204.172
173.948
147.822
120.895
87.052
67.007
39.515
15.086
4.150
1.027

Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc.


Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.

Page 3

IES INDOOR REPORT


PHOTOMETRIC FILENAME : BALA LED CETUS RA OP 10W.IES
ZONAL LUMEN SUMMARY
Zone

Lumens

%Lamp

%Fixt

0-20
0-30
0-40
0-60
0-80
0-90
10-90
20-40
20-50
40-70
60-80
70-80
80-90
90-110
90-120
90-130
90-150
90-180
110-180
0-180

126.53
270.19
425.43
709.46
841.47
848.12
814.38
298.89
450.85
373.59
132.01
42.45
6.64
0.00
0.00
0.00
0.00
0.00
0.00
848.12

15.00
31.90
50.30
83.90
99.50
100.30
96.30
35.30
53.30
44.20
15.60
5.00
0.80
0.00
0.00
0.00
0.00
0.00
0.00
100.30

14.90
31.90
50.20
83.70
99.20
100.00
96.00
35.20
53.20
44.00
15.60
5.00
0.80
0.00
0.00
0.00
0.00
0.00
0.00
100.00

Total Luminaire Efficiency = 100.30%

ZONAL LUMEN SUMMARY


Zone

Lumens

0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

33.73
92.80
143.65
155.24
151.95
132.08
89.56
42.45
6.64
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc.


Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.

Page 4

IES INDOOR REPORT


PHOTOMETRIC FILENAME : BALA LED CETUS RA OP 10W.IES
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
Effective Floor Cavity Reflectance 0.20
RC
RW

80
70 50 30 10

70
70 50 30 10

50
50 30 10

30
50 30 10

10
50 30 10

0
0

0
1
2
3
4
5
6
7
8
9
10

119 119 119 119


110 10610298
10193 87 81
92 82 75 68
85 73 65 59
78 66 57 51
72 59 51 45
67 54 46 40
63 50 41 36
59 46 38 32
55 42 34 29

117 117 117 117


107 103 100 97
98 91 85 80
90 81 74 68
83 72 64 58
76 65 57 51
70 59 50 44
66 53 45 40
61 49 41 35
57 45 37 32
54 42 34 29

111 111 111


99 96 94
88 83 78
78 72 67
70 63 57
63 55 50
57 50 44
52 45 39
48 40 35
44 37 32
41 34 29

107107107
95 93 91
84 80 77
75 70 65
67 61 57
61 54 49
55 49 44
50 44 39
46 40 35
43 36 32
40 33 29

102102102
92 90 88
81 78 75
73 68 64
65 60 56
59 53 49
54 48 43
49 43 39
45 39 35
42 36 32
39 33 29

100
86
73
62
54
47
41
37
33
30
27

Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc.


Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.

Page 5

IES INDOOR REPORT


PHOTOMETRIC FILENAME : BALA LED CETUS RA OP 10W.IES
POLAR GRAPH

368

276

184

92

Maximum Candela = 367.54 Located At Horizontal Angle = 0, Vertical Angle = 0


# 1 - Vertical Plane Through Horizontal Angles (90 - 270)
# 2 - Vertical Plane Through Horizontal Angles (0 - 180)

Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc.


Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.

Page 6