You are on page 1of 14

Kitsnet

Multi-port Flow Selector Valve

6 inlet ports 2

16 inlet ports

8 inlet ports

10 inlet ports

Page 1 of 14

Introduction
The Multi-port Flow Selector Valve (MSV) is a kind of special equipment
which is used in the metering station of oilfields for the purpose of metering of
oil well fluid. Instead of the complicated conventional /existing manifold and
powered T valves group, it can be more simply operated for well-selection
and metering with local control or remote control mode. It also can be easily
operated with hand wheel for well-selection and metering on site too.

Capability & Function


Simple structure, small size, compact design, easy to install and operate
Little maintenance, long service life.
Hard alloy coated sealing surface, its hardness is up to HRC60-62,
acid/alkali corrosion resistance, with high sealing reliability.
Suitable for sand content oil service and being flush erosion resistant
because of the hard alloy coated
sealing surface.
It can endure the high temperature
of 150 for light oil; 300 for
heavy oil.
It can endure the high temperature
of 150 for light oil; 300 for
heavy oil.
The internal leakage level is up to
GB/T4213-1992

and

ANSI/FCI 70-2-1999/.
It will take very short time to select
the required position of valve and it
only takes less than 15 seconds to

Page 2 of 14

arrive at the next valve position.


It is with very a little abrasion loss of the hard alloy sealing surface, besides,
the clearance between the sealing surfaces can be self offset with its special
design structure.
The flow channel within the valve body is designed of all circular arc shape
transition so that the flow resistance factor is very small. The wall thickness
of the valve body is proper designed for a very long life span.
Adopt digital technique to inspect/test the valve position and the signal is
stable and accurate; the total position determination error is only0.5.
The wave spring for pre-pressure compensation is installed under the
bottom of the motive seal within the valve, and an adjusting/checking hole is
specially designed on the valve bonnet, we can open it to adjust the
pre-pressure when necessary. It is convenient for check and maintenance of
the Multi-port Flow Selector Valve too.
The Remote Control Mode: Be able to realize computer control operation via
communication mode 485. The Stepping Mode: Turn the stepping switch
(on/off) by hand for stepping operation. Hand Wheel Operation Mode: Turn
the hand wheel by hand for operation on site.
Fire test in conformity with API spec 6FA.

Page 3 of 14

Description
The common pressure level for Multi-port Valve is to seePage 10.
The normal Diameter of Multi-port Valve is to seePage 10.
The common use material of Multi-port Valve is to seePage 10.
The electrical powered driving unit of Multi-port Valve is explosion-proof
ExdBT4 and protection level IP 67.
The international and national patents No.s

200420006528.1

200420073455.8 200620019902.0200620135470.X200620167076.4
PCT/CN2007/000888 PCT/CN2007/002012.

Page 4 of 14

Options

Pressure rating for multi-port valve and flange connection.

Connection pipe wall thickness (Schd).

Material of Multi-port Valve.


The oil-inlet port size of Multi-port Valve
for a single well.

The group outlet port size of Multi-port


Valve.

Control system of Multi-port Valve:


control box, explosion-proof control box,
and integrated control system.
Motor Voltage: 380VAC220VAC110
VAC 24VDC1350 PRMYDF.

The output torque and rotation speed of explosion-proof electrical powered


driving unit of Multi-port Valve: 600N.m800 N.m1200N.m1500N.m
2500N.m0.5/0.2RPM.
Third part inspection & certification agency e.g. DNA, CCS etc. or any
specified on.

Page 5 of 14

37

38 39

40 41
42

46

20

Page 6 of 14

13

4
3

"o"-sealing ring

Spring washer
Flat washer

32
31

1
Packing filler
Name
No.

Name

Valve body

2
28

No.

"o"-sealing ring

3
Packing gland

29
27

"o"-sealing ring
Tapered roller bearing

4
Nut
Stud

30

Drainage screw plug

Rotation plug

Internal-hex adjusting nut

Dished spring

8
Flat washer
Bolt bolt

Spring washer

35
33

Sealing ring
Thrust washer

10
34

"o"-sealing ring

11
Flat key
Spacer

36

Fan-shaped valve seat ring

12
37

Actuator bracket

38

indicating arrow

Assembly

39

"o"-sealing ring
Metal clad gasket

14
Inner-hex tapered locking screw

40

15
Inner-hex tapered locking screw

41

8
7

Set screw
Tapered roller bearing
Valve position indicating board

42

10

16

Bolt

43

11

17

Flat washer

44

12

Lifting bail/Lug
Spring washer

46

Adjusting nut

Valve bonnet

21

Additional

45

13

15
14

Welding flange

Nut
Stud bolt

22

18

Flat washer

23

Bolt
Grease cup

19

Screw plug
Spring washer

24

Retainer ring

26
25

47

36

48

28

16

27

17

26

45
44
43

Nozzle sealing gasket

25

35
34
33

49

18

19

20

24
23
22
21

32
31
30
29

Assembly of Multi-port Valve

Fitting of Valve Seat Ring

Position Selection & Control


I ntegrated optical coupling circuit board and Photoelectric encoder device
combined into a 4-way valve coded signal.
Four basic unit of optical encoder circuit is independent of each other,
positive and negative can be wired, no damage to the circuit board.
Applying four miniature low-power relay output, with the outside world
completely isolated.
Operating temperature -30 to 120 .
Applicable to both sink input and source
input connection wiring.
No mechanical wear.
Positioning accuracy of 0.5
Working life to 106.

Page 7 of 14

Position Mode & Display

Switch Mode
A ButtonRedValve Position
B ButtonBlackStepping-OnStepping-Off.
Mode & DisplayValve Position ModeLLocal
RRemoteRemote Control. SShut offStop.
Position Display011# Position022# Position033# Position
044# Position,and so like.

Communication protocol & address


Communication Mode:

RS485

Communication protocol Modbus RTU protocol


The communication parameters default/acquiescence setting
Device Address 11-200

Baud rate

96001200,24004800,9600,19200,38400.

Parity: none (none, odd, even).

Data Bits

8bits. Stop bits:

1.

Register address
There are 4 register addresses to be used by upper-computer (PC), using the standard
address format of Modbus Rtu protocol.
Valve position setting register address 40003
Valve position display register address 40004
Mode conversion register address 40005
Mode conversion register address 40006
Note:The register data format is of decimal system.

Page 8 of 14

Electrical principle

ELECTRONIC DIGITAL DISPLAY BOARD

C PU 224XP CN

S IE M E N S
S 7 -2 0 0
2 1 4 -2 B D 2 3 -O X B 8

6
D1

7
D2

D3

10

11

12

D4 ZH1 ZH2 ZH3

GZ

13

14

BJ

RS485

Note:The communication wire for RS485 has been connected to the


terminal inside the electrical driving head,while there is a
correspouding wire connection terminal outside for
conveniently wiring out.

Terminals Diagram for Wiring

24V
24V

D1

D2

D3

D4

ZH1

ZH2

10

ZH3

11

GZ

12

BJ

13

BX

14

BX

15

24 Volt PUBLIC TERMINALS 24V

24 Volt PUBLIC TERMINALS 24V

0 V
0 V

0 Volt PUBLIC TERMINALS 0V

0 Volt PUBLIC TERMINALS 0V

SIGNAL 1 1
SIGNAL 2 2
SIGNAL 3 3
SIGNAL 4 4
REMOTE SIGNAL
LOCAL SIGNAL
CUT SIGNAL
OVERLOAD SIGNAL
STEPPING SIGNAL
0 Volt ELECTRIACAL FUSE 0.5A 0V 0.5A
24 Volt ELECTRIACAL FUSE 0.5A 24V 0.5A

Page 9 of 14

F
U
S
E

Size & Specification of MSV


Service

Heavy oil/light oil

Medieum Temp.()

-29300

Operation Temp.()

-3070

Nominal Pres.(lb)

150,300,400,600,900,1500,2500

oil-inlet ports

4681012141516,18

oil-inlet Port Nominal Dia.


inch

1 3
1
1
1
, ,1, 1 ,2, 2 ,3, 3 ,4,6,8,10
2 4
4
2
2
1 3
1
1
1
, ,1, 1 ,2, 2 ,3, 3 ,4,6,8,10
2 4
4
2
2
3
1
1
1
,1, 1 ,2, 2 ,3, 3 ,4,6,8,10
4
4
2
2

Test out-let port Nominal


Dia.inch
Group-outlet Port Nominal
Dia.inch
Control System

Common control box; Explosion-proof control


box; Integrated Mechano-eletronic Control box

Output TorqueNm

600,800,1000,1200,1500,2500,5000

Output Rotation
r/Min

speed 0.2,0.3,0.5

Valve Body material

A216M-WCB,A351M-CF8A351-CF3M,
A487M-1C, Duplex stainless steel,etc.

Bolts &Nuts Standard

ASTM A193/193M ASTM A194/194M

valve Seat Leakage level

Power Driving Actuator

Explosion-Proof ClassExdBT4

Note: The data within the table are common used data, but the nominal
Dia. & Pres. and material of MSV can be designed on the basis of the
users requirements.

Page 10 of 14

Kitsnet MSV Outline Figures


2150 lb MSV Outline Figures

Unit:mm.

Page 11 of 14

Kitsnet MSV utline Figures


3300 lb MSV Outline Figures

Unit:mm.
Page 12 of 14

Kitsnet MSV Outline Figures


4900lb MSV Outline Figures

Unit:mm.
Page 13 of 14

Contact us
Business Contact:
Telephone: 86 +0990-6223690/13999301712
Email: wmm@kitsnet.cn
Technical Support:
Telephone:86+09906228306/13999501886
Email: yjs@kitsnet.cn
After-sale Service:
Telephone:86+ 09906879900/13999515675/13565456395
Email: rxr@kitsnet.cn/cjs@kitsnet.cn
Fax:86+ 0990-6228306/6223690
Website: http//www.kitsnet.cn
Kelamayi King-Bull Infortec Petroleum Equipment Company, Ltd.
Address: No.30#,Ashan Road, Kelamayi City, Xinjiang, China.
Post code: 834000

Page 14 of 14