~FUGRO-SUHAIMILTD, funwn- Sonar CALIBRATION DEPARTMENT jessie "asco For pao 08 na haootengeerseon ! (CERTIFICATE No. 058077-74409 ge tof 2 CALIBRATION CERTIFICATE OF SIEVE cunt: Office ADDRESS: AlKhobar, Kingdom of Saudi Arabia ‘Ayed Eid Al Osaimi Consulting Civil Engineering PROJECT No.: SADS-8077 DATE: 30 January 2015 This sto certty thatthe equipment described below has been calibrated by Fugro-Suhaimi Limited. ‘This certificate applies only to the equipment specified in thie cerca. Details of Device under Calibration (DUC) (Gorman supa bye sen Description ‘SIEVE Manulacturer: GILSON Model Serial identncation No. | 10209828 /EKS-120 Cepacity/ Range 250 um Resolution / Accuracy NA ‘Speciation Limit ‘As per Manufaciurers Speciation Remarks Ni Calibration Details: Dale Insiument Recsived [28 January 2015 Calibration Date: 30 January 2015 | Next Catbration Due Date 30 January 2016 Location of Calibration: FFSL Calbraton Laboraton, Dammam Calibrated by: Mw Checked by: ZHR Remarks Ni Roviewad By ‘Approved By albiaton Technician aoe Rehman ‘Supetvisor Calibration Laboratory, Dammam 30 January 2016 Baie '80 70262005 ACCREDITED LABORATORY ‘The conipit is eomenwonrety FuyeSu Li inate epeices nN wt pp fom eons. CALBOOreIrOrCHaD:9 ———_Ammeméer of the Fugro group with ofc wordwide “Te cpnianatt sou FUGRO-SUHAIMI LTD. {CALIBRATION DEPARTMENT Talc) as ao Fue (ease aag pfege Seam SS See ees, A eal CERTIFICATE Na oso? 2a Patera RESULTS OF CALIBRATION OF SIEVE Catiaton Procedurs Cabaton Paced FELCALAGS Relererce sandr ASTME 11 SSATITET Calibration Data supe [oanewrieci | sinesinn) [ag TTS, Ear 3] 756 ecplabe ‘Tho Seve is examined visually Yor weaving GEIEGS, ceases, winKleS and foreign matter, by viewing against a uniformly iluminateg (On examination the sieve backaround. | found tobe acceptable Factor k-2, proving a level of confidence of approximately 85% ‘Test Conditions: Measurement Uncertainty: The expanded uncerianty ofthe above measurement im extmmaled alto exceed + 0.01 um, based on Type A and B Standard uncetantes mulpled by a coronas ‘Ariblent Temperature 20s Relative Hum: 50% Details of Reference Device: Description: Digital Vernier Calper Manufacturer mTuTOve ‘Serial /dentfication Number] FSLID Ne, 0-251 Resolution / Least Count 0.0% mm Calibration Traceabity “Traceable to International Standard Calibration Expiry Date (05 May 2016 Remarks! Ni 's0 #7028200 accREDITED LABORATORY {CAL 800/e1/0-ce2013 member ofthe Fugro group wih ofces wordwide owes by Fao Stam Kays te apie! natin adh tena em omg ny—

You might also like