The solutions in the document are the operation method for particular alarm.
Actually, sometimes the different alarms will rise in a site or sector. One alarm may
be caused by another. Hence, we need to distinguish the priority of these alarms
when handle them. The structure of the document follows the priority (like the
contents).
3 , 8
Example.txt
2016-3-26
4 , 8
AISG cable
2016-3-26
R
C
U
5 , 8
4 The confused connection of feeders or jumpers. As the figure below, the jumper
of sector3 has be connected to the TMA of sector1. So, even there is no the alarm of
RF Unit ALD Current Out of Range, the problem is caused by wrong installation.
To judge this situation, we can turn off the dc supply in the alarm port ,then if the
current of another N1B
port in other sectors increase, that means the two ports in different
sectors are connected to one TMA. (See attachment Example2)
N1A
Example2.txt
N0A
N0B
Solution:
1 Conform the ALD network and installation status, avoid to add the device which
do not exist;
2 Configure the device in right way;
3 Check the AISG connection between RCU and TMA.
4 Check the tag of jumpers, clear up all the jumpers and their mark. Confirm the
each jumpers is installed in the right ports (may need to check the jumpers actual
2016-3-26
6 , 8
TMA
each jumper is installed in the right ports (may need to check
the jumpers actual
NodeB0
RET
NodeB1
connection with hand from end to end).If still not work, remakeNodeB0
all tagsRET
of jumpers.
NodeB1
Antenna
RFU
2016-3-26
7 , 8
R
C
U
Solution:
Operate the command to calibrate RET and then set the tilt as the configured tilt.
Operation:
DSP ANTTILT DSP ANTCONCLB ANTSET ANTTITLCheck alarm