FLANGED FITTINGS
Sizes 3" thru 12" UL Listed for Fire Main Equipment
SAMPLE SPECIFICATION
Flanged Fittings, 2" through 48" shall be manufactured of Ductile Iron in accordance with all applicable terms and provisions of
standards ANSI/AWWA C110/A21.10 (current revisions). Flange surface shall be faced and drilled in accordance with ANSI Class
125 B16.1. All Ductile Iron Flanged Fittings shall be rated for water pressure of 250 PSI. Flanged ductile-iron fittings in 24-in. (610
mm) and smaller sizes may be rated for 350 psi (2,413 kPa) with the use of special gaskets. NOTE: Fittings are CEMENT-LINED
and seal coated in accordance with ANSI/AWWA C104/A21.4, also available prime coated, bare or epoxy coated. All coated fittings
meet requirements of NSF-61. Interiors shall be lined and seal coated in accordance with ANSI/AWWA C104/A21.04, Cementmortor Lining for Ductile Iron Pipe and Fittings for Water unless otherwise specified.
FLANGE DETAILS
Nominal
Pipe Size
Inch
2
3
4
6
8
10
12
14
16
18
20
24
30
36
42
48
Flange
O.D.
6
7.5
9
11
13.5
16
19
21
23.5
25
27.5
32
38.75
46
53
59.50
Dia. of
Bolt
Circle
4.75
6
7.5
9.5
11.75
14.25
17
18.75
21.25
22.75
25
29.5
36
42.75
49.50
56.00
Flange
Thickness
T
.62
.75
.94
1.00
1.12
1.19
1.25
1.38
1.44
1.56
1.69
1.88
2.12
2.38
2.62
2.75
Bolt Hole
Diameter
.75
.75
.75
.875
.875
1.00
1.00
1.125
1.125
1.25
1.25
1.375
1.375
1.675
1.625
1.625
Number
of Bolts
Bolt Dia.
and Lengths
4
4
8
8
8
12
12
12
16
16
20
20
28
32
36
44
x 2
x 2
x 3
x 3
x 3
x 4
x 4
1 x 4
1 x 4
1 x 5
1 x 5
1 x 5
1 x 6
1x7
1x7
1x8
NOTE: Drilling templates are in multiples of four, so that fittings may be made to face in any
quarter. Bolt holes shall straddle the center line.
28
Tyler Utilities Division 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
Union Foundry Company Box 309 Anniston, Alabama 36202 (800) 226-7601
02/01/08
BENDS
Note: Base Bends are on page 33 and 34, reducing and long radius 90 bends are on page 33.
90Bends (1/4)
Size
2
3
4
6
8
10
12
14
16
18
20
24
30
36
42
48
45 Bends (1/8)
Dimensions
R
A
Weight
3.0
4
4.5
6
7
9
10
11.5
12.5
14
15.5
18.5
21.5
24.5
27.5
30.5
02/01/08
4.5
5.5
6.5
8
9
11
12
14
15
16.5
18
22
25
28
31
34
14
26
44
67
115
164
236
330
478
527
878
1085
1755
2135
3055
4095
Dimensions
R
A
...
3.62
4.81
7.25
8.44
10.88
13.25
12.06
13.25
14.5
16.88
18.12
27.75
35.00
42.25
49.50
...
3
4
5
5.5
6.5
7.5
7.5
8
8.5
9.5
11
15
18
21
24
Weight
...
20
36
57
105
131
196
245
315
422
485
730
1355
1755
2600
3580
...
7.56
10.06
15.06
17.62
22.62
27.67
25.12
27.62
30.19
35.19
37.69
57.81
72.88
88.00
103.06
...
3
4
5
5.5
6.5
7.5
7.5
8
8.5
9.5
11
15
18
21
24
Weight
...
22
35
64
90
130
194
250
315
402
505
528
1385
1790
2665
3665
Tyler Utilities Division 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
Union Foundry Company Box 309 Anniston, Alabama 36202 (800) 226-7601
...
15.25
20.31
30.5
35.5
45.69
55.81
50.75
55.81
60.94
71.06
76.12
116.75
147.25
177.69
208.12
...
3
4
5
5.5
6.5
7.5
7.5
8
8.5
9.5
11
15
18
21
24
Weight
...
20
40
56
90
130
193
245
315
385
505
760
1395
1805
2680
3695
29
Run
Size
Run
2
3
3
4
*4
4
4
*4
*6
*6
*6
6
6
6
6
*8
*8
*8
8
8
8
8
*8
*8
*10
*10
*10
*10
*10
10
10
10
10
10
* 12
*12
*12
2
3
3
3
4
4
4
4
4
4
6
6
6
6
6
6
6
6
8
8
8
8
8
8
6
6
8
8
8
10
10
10
10
10
6
6
8
30
Branch
2
2
3
3
2
3
4
6
4
6
2
3
4
6
8
4
6
8
3
4
6
8
10
12
6
10
6
8
10
4
6
8
10
12
6
8
6
*Reducing
on Run
Dimensions
H
J
4.5
5.5
5.5
6.5
6.5
6.5
6.5
8.0
8.0
8.0
8.0
8.0
8.0
8.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
11.0
12.0
13.0
13.0
13.0
13.0
13.0
11.0
11.0
11.0
11.0
12.0
14.0
14.0
14.0
4.5
5.5
5.5
5.5
6.5
6.5
6.5
8.0
8.0
8.0
8.0
8.0
8.0
8.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
11.0
12.0
13.0
13.0
13.0
13.0
13.0
11.0
11.0
11.0
11.0
12.0
14.0
14.0
14.0
*Reducing on
Run and Branch
Weights
Tee
Cross
20
35
42
53
55
54
60
88
96
100
85
85
90
98
138
130
148
154
128
155
148
179
225
277
278
308
298
278
325
239
215
254
265
337
346
362
355
...
51
...
...
76
87
...
...
...
...
96
112
141
...
...
...
...
140
155
172
195
...
...
...
...
...
...
...
220
242
294
330
...
...
...
...
*Bullhead
Tees
Run
Size
Run
*12
*12
*12
12
12
12
12
12
12
12
12
*14
14
14
14
14
14
*16
16
16
16
16
16
16
18
18
18
18
18
18
18
8
8
10
10
10
10
12
12
12
12
12
14
14
14
14
14
14
16
16
16
16
16
16
16
18
18
18
18
18
18
18
Branch
8
12
6
8
10
12
4
6
8
10
12
4
6
8
10
12
14
4
6
8
10
12
14
16
6
8
10
12
14
16
18
Straight and
Reducing Crosses
Dimensions
H
J
12.0
12.0
14.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
14.0
14.0
14.0
14.0
14.0
14.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
13.0
13.0
13.0
13.0
16.5
16.5
16.5
12.0
12.0
14.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
14.0
14.0
14.0
14.0
14.0
14.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.5
15.5
15.5
15.5
16.5
16.5
16.5
Weights
Tee
Cross
375
420
390
400
420
440
322
297
346
394
369
410
420
435
450
470
500
525
573
555
565
590
610
635
780
609
585
638
808
760
865
...
...
...
...
...
...
310
326
351
415
438
...
450
475
...
555
595
...
565
590
620
665
...
755
...
...
...
706
...
...
915
Tyler Utilities Division 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
Union Foundry Company Box 309 Anniston, Alabama 36202 (800) 226-7601
02/01/08
Size
Run
20
20
20
20
20
20
20
20
24
24
24
24
24
24
24
24
24
*30
30
30
30
30
36
36
36
42
42
42
42
48
48
48
48
48
20
20
20
20
20
20
20
20
24
24
24
24
24
24
24
24
24
30
30
30
30
30
36
36
36
42
42
42
42
48
48
48
48
48
Branch
6
8
10
12
14
16
18
20
6
8
10
12
14
16
18
20
24
6
12
18
24
30
24
30
36
24
30
36
42
24
30
36
42
48
Dimensions
H
J
14.0
14.0
14.0
14.0
14.0
18.0
18.0
18.0
15.0
15.0
15.0
15.0
15.0
15.0
22.0
22.0
22.0
18.0
18.0
18.0
25.0
25.0
20.0
28.0
28.0
23.0
31.0
31.0
31.0
28.0
26.0
34.0
34.0
34.0
02/01/08
17.0
17.0
17.0
17.0
17.0
18.0
18.0
18.0
19.0
19.0
19.0
19.0
19.0
19.0
22.0
22.0
22.0
23.0
23.0
23.0
25.0
25.0
26.0
28.0
28.0
30.0
31.0
31.0
31.0
34.0
34.0
34.0
34.0
34.0
Tee
773
720
735
816
770
950
965
1005
1089
1060
1020
1125
1050
1070
1534
1510
1685
1725
1801
1852
2475
2615
2255
3000
3160
3245
4125
5360
5580
4385
4455
5555
7195
7385
Weights
Cross
...
...
...
820
...
1065
...
1175
...
...
...
1100
1125
1160
...
1695
1850
...
...
...
2695
2985
...
...
...
...
...
...
...
...
...
...
...
...
3
4
6
8
10
12
14
16
18
20
24
Dimensions
D
X
Y
7.5
9.0
11.0
13.5
16.0
19.0
21.0
23.5
25.0
27.5
32.0
5.5
6.5
8.0
9.0
11.0
12.0
14.0
15.0
16.5
18.0
22.0
8.5
9.5
12.0
13.0
15.0
16.0
22.0
23.0
24.5
26.0
30.0
Weight
26
39
73
110
171
253
450
545
675
860
1195
3
4
6
8
10
12
14
16
18
20
24
Dimensions
D L Weight
7.25
9.00
11.00
13.50
16.00
19.00
21.00
23.50
25.00
27.50
32.00
8
8
8
10
10
12
16
16
16
18
18
Tyler Utilities Division 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
Union Foundry Company Box 309 Anniston, Alabama 36202 (800) 226-7601
21
30
44
75
113
155
225
330
355
465
598
31
REDUCERS
Concentric Reducer
Eccentric Reducer
Size
Dimensions Wts
D
D 1
L
Size
Dimensions Wts
D
D 1
L
Size
Dimensions Wts
D
D 1
L
Size
Dimensions Wts
D
D 1
L
3
4
4
6
6
6
6
8
8
8
8
10
10
10
12
12
12
12
14
14
14
14
16
16
16
16
16
18
18
18
18
18
20
20
20
20
20
24
24
24
24
24
30
30
30
30
42
42
42
48
48
48
4
6
6
8
8
10
10
12
12
12
16
16
16
16
16
18
18
18
18
18
20
20
20
20
20
24
24
24
24
24
42
42
42
48
48
48
2
2
3
2
3
4
5
3
4
5
6
4
6
8
4
6
8
10
6
8
10
12
6
8
10
12
14
6
7
7
9
9
9
9
11
11
11
11
12
12
12
14
14
14
14
16
16
16
16
18
18
18
18
18
17
23
29
30
44
46
56
61
63
70
75
98
107
116
119
130
152
178
165
185
205
235
210
230
255
285
315
8
10
12
14
16
10
12
14
16
18
12
14
16
18
20
16
18
20
24
24
30
36
30
36
42
19
19
19
19
19
20
20
20
20
20
24
24
24
24
24
30
30
30
30
42
42
42
48
48
48
265
290
320
350
405
418
465
430
445
470
608
565
610
645
695
945
970
1144
1155
1810
2060
2345
2615
2940
3320
NOTE: Eccentric
Reducers not included in
AWWA C110
32
3
3
4
4
6
6
8
6
8
10
6
8
10
12
14
8
10
12
7
9
9
11
11
12
12
14
14
14
18
18
18
18
18
19
19
19
30
45
52
70
80
98
123
135
149
177
210
230
255
285
315
265
290
306
14
16
10
12
14
16
18
12
14
16
18
20
24
30
36
30
36
42
19
19
20
20
20
20
20
24
24
24
24
24
42
42
42
48
48
48
350
385
350
370
402
449
455
535
570
614
645
695
1820
2060
2345
2625
2950
3320
Tyler Utilities Division 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
Union Foundry Company Box 309 Anniston, Alabama 36202 (800) 226-7601
02/01/08
* WYES/LATERALS
*45 Wye
Size
Run Branch
3
4
4
6
6
8
8
8
10
10
10
10
12
12
12
12
12
14
14
14
14
14
16
16
16
16
16
16
18
18
18
18
18
18
20
20
20
20
20
24
3
3
4
4
6
4
6
8
4
6
8
10
4
6
8
10
12
6
8
10
12
14
6
8
10
12
14
16
8
10
12
14
16
18
10
12
14
16
20
24
Dimensions
H J
Weight
10
12
12
14.5
14.5
17.5
17.5
17.5
20.5
20.5
20.5
20.5
24.5
24.5
24.5
24.5
24.5
27
27
27
27
27
30
30
30
30
30
30
32
32
32
32
32
32
35
35
35
35
35
40.5
*90 Reducing
Bend (1/4)
True Wye
3
3
3
3.5
3.5
4.5
4.5
4.5
5
5
5
5
5.5
5.5
5.5
5.5
5.5
6
6
6
6
6
6.5
6.5
6.5
6.5
6.5
6.5
7
7
7
7
7
7
8
8
8
8
8
9
49
68
76
106
131
153
188
201
232
288
333
300
355
370
395
420
460
500
525
555
600
640
655
680
715
755
800
850
820
855
1003
940
990
1035
1095
1130
1170
1220
1345
2020
Size
Dimensions
Stem Branches X
Y Weight
4
6
6
8
8
4
4
6
6
8
6.5
8.0
8.0
9.0
9.0
3.0 49
3.5 75
3.5 84
4.5 134
4.5 125
Dimensions
Size
A
Weight
4x3
6x4
8x4
8x6
10x6
10x8
12x6
12x8
12x10
6.5
8
9
9
11
11
12
12
12
35
65
88
96
126
151
172
191
218
Size
3
4
6
8
10
12
14
16
Dimensions
R
A
6.25
7
9.5
14
16.5
17
19
21.5
Weight
7.75
9
11.5
14
16.5
19
21.5
24
32
46
83
140
252
310
475
630
* Not included in
AWWA C110
Base Bends
are made
to order
only, not
returnable.
Bases are
furnished
faced and
drilled.
3
4
6
8
10
12
14
16
18
20
24
30
Support
Dimensions
Pipe
X
S
U
Size
4.88
5.5
7
8.38
9.75
11.25
12.5
13.75
15
16
18.5
23
5
6
7
9
9
11
11
11
13.5
13.5
13.5
16
.50
.50
.62
.88
.88
1.00
1.00
1.00
1.12
1.12
1.12
1.15
1.5
2
2.5
4
4
6
6
6
8
8
8
10
Base Tees
90
Weight
90LR
Tee
38
50
83
142
210
300
400
505
645
805
1215
1945
41
60
100
180
315
427
580
740
...
...
...
...
47
76
115
195
315
450
570
710
900
1125
1927
...
Tyler Utilities Division 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
Union Foundry Company Box 309 Anniston, Alabama 36202 (800) 226-7601
33
* FLANGE SLUDGE
SHOE
Base Under
Large End
Size
Base Under
Small End
Dimensions
X
S
4x3
5.5
6x4
7
8x4
8.38
8x6
8.38
10x6
9.75
10x8
9.75
12x6
11.25
12x8
11.25
12x10 11.25
6
7
9
9
9
9
11
11
11
Weight
.50
.62
.88
.88
.88
.88
1.00
1.00
1.00
45
75
118
135
175
184
230
255
285
Nom.
Diameter
Inches
Weight
3 5.75 12
6
28
4 7.00 12
6
35
6 7.87 12
6
45
8 10.12 12
6
69
10 12.25 12
6
88
12 15.25 12
6
120
* Not included in AWWA C110
Size
Dimensions
D
X
Y
Dimensions - Inches
Bolt Hole Number
BC
Diameter
of Bolts
3
4
6
8
10
12
14
16
18
20
24
30
36
42
48
3.88
4.75
5.50
7.50
7.50
9.50
9.50
9.50
11.75
11.75
11.75
14.25
17.00
21.25
22.75
5/8
3/4
3/4
3/4
3/4
7/8
7/8
7/8
7/8
7/8
7/8
1
1
1-1/8
1-1/4
Size
Dimensions
Y
Steel
DI
2
2
3
4
6
8
10
12
14
16
18
20
24
30
36
42
48
6
7
7.5
9
11
13.5
16
19
21
23.5
25
27.5
32
38.75
46.00
53.00
59.50
.62
.69
.75
.94
1.00
1.12
1.19
1.25
1.38
1.44
1.56
1.69
1.88
2.12
2.38
2.62
2.75
1
1.13
1.19
1.31
1.56
1.75
1.94
2.19
2.25
2.5
2.69
2.88
3.25
...
...
...
...
4.75
5.50
6.00
7.50
9.50
11.75
14.25
...
...
...
...
...
...
...
...
...
...
4
8
7
12
21
28
49
61
...
...
...
...
...
...
...
...
...
...
...
6
11
14
34
33
52
72
90
105
115
160
255
...
...
...
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
eight
W
Blind Blind Tap
...
...
8
15
28
45
62
72
110
165
192
249
375
580
790
1175
1585
...
...
8
15
28
45
62
87
110
165
190
250
370
580
...
...
...
34
DI Reducing Flange
Threaded For Steel Pipe
Size
4x3
6x4
8x4
8x6
10x6
12x6
10x8
12x10
DI Reducing Flange
Threaded For Cast Iron Pipe
Tap x O.D.
Weight
Size
Tap x O.D.
3x9
4x11
4x13
6x13
6x16
6x19
8x16
10x19
16
25
44
31
50
60
55
72
4x3
6x4
8x4
8x6
10x8
12x8
3x9
4x11
4x13
6x13
8x16
8x19
Tyler Utilities Division 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
Union Foundry Company Box 309 Anniston, Alabama 36202 (800) 226-7601
Weight
16
25
40
35
50
85
02/01/08
ADAPTER FLANGES
(EZ OR UNI)
Size
Ductile Iron
Pipe OD
+.06 or -.06
3
4
6
8
10
12
3.96
4.80
6.90
9.05
11.10
13.20
D
+.06
-.04
4.94
6.02
8.12
10.27
12.34
14.44
F
+.07
-.03
Weight
4.06
4.90
7.00
9.15
11.20
13.30
.94
1.00
1.06
1.12
1.19
1.25
7
10
14
22
30
40
No. of
Set
Bolt
Screws Circle
3
4
6
8
10
12
4
4
8
8
12
12
250
250
250
250
250
150
6.00
7.50
9.50
11.75
14.25
17.00
No. of
Bolt &
Size
Nuts of Bolt
4
8
8
8
12
12
x2
x3
x3
x3
x4
x4
Bolt
Hole
Dia.
1
1
Fittings can be supplied with taps sized and located to ANSI B16.1
and MSS-SP-45. Specify fitting size, tap location by letter (refer to
drawings) and tap size by NPT dimension, on order.
Note:
Fitting
itting
F
Size
Size
Maximum
TapTap
Maximum
Without
Boss
Without
Boss
3"........................1/2"
4" - 6"................. 3/4"
8"........................1-1/4"
10" - 16"............. 1-1/2"
18" - 30"............. 2"
Tyler Utilities Division 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
Union Foundry Company Box 309 Anniston, Alabama 36202 (800) 226-7601
35