Professional Documents
Culture Documents
Date:
9/1/2015
Page
of
A summary of the rating criteria (Severity Scale, Occurrence Scale, Detection Scale) and classifications
that were used in the analysis.
The Process FMEA (PFMEA) spreadsheet report in the AIAG Form A reporting format.
A summary list of the potential causes of failure that were identified through the analysis, ranked by
Initial Occurrence rating.
A summary list of the recommended actions identified during the analysis.
A summary list of the current controls identified during the analysis.
The report is based on the sample analysis provided in the AIAG FMEA-3 guidelines, on page 36.
Date:
9/1/2015
Page
of
Criteria 1
Criteria 2
No effect
No discernible effect.
No discernible effect.
Very Low
Annoyance
Low
Annoyance
Low
Annoyance
Moderate
Degradation of Secondary
Function
Moderate
Moderate
High
High
High
10
10
Very High
Criteria 1
Criteria 2
Almost Certain
Very High
Classification Options
Abbreviation
Criteria
Failure is eliminated through
preventative control.
Description
Critical
KI
Key Intermediate
Criteria 2
High
Moderately High
Moderate
Low
Very Low
Remote
Very Remote
10
Almost Impossible
No detection opportunity.
Date:
9/1/2015
Page
KLd
Key Leading
KLg
Key Lagging
of
Significant
POTENTIAL
FAILURE MODE AND EFFECTS ANALYSIS
Front Door L.H.
Manually inserted
spray head not
inserted far enough
RPNi
DETi
5
Recommended
Action(s)
Responsibility &
Actions Taken &
Planned
Completion Date Actual Completion
Date
Spray head
clogged- Viscosity
too highTemperature too
low- Pressure too
low.
Spray head
deformed due to
impact
Preventive
maintenance
program to
maintain heads.
70
Spray time
insufficient
Operator
instructions and lot
sampling (10
doors/shift) to
check for coverage
of critical areas.
RPNr
Allows integrity
breach of inner
door panel.
Corroded interior
lower door panels.
Deteriorated life of
door leading to:
- Unsatisfactory
appearance due to
rust through paint
over time
- Impaired function
of interior door
hardware
Current Process
Controls
(Detection)
DETr
Insufficient wax
coverage over
specified surface
Current Process
Controls
(Prevention)
OCCr
Potential
Cause(s) of
Failure
SEVr
Requirements
Potential
Effect(s) of
Failure
FMEA Number
1450
Page
4
of
8
Prepared By
J. Ford - X6521 - Assy Ops
FMEA Date (Orig.)
7/1/2015
(Rev)
7/15/2015
Action Results
OCCi
Potential Failure
Mode
Classification
Name / Function
SEVi
FMEA Type
Component
Item
1.1.1 - Front Door L.H.
Process Responsibility
Body Engineering
Model Year(s)/Vehicle(s)
201X/Lion 4dr/Wagon
Key Date
7/22/2015
Core Team
A. Tate - Body Engrg, J. Smith - OC, R. James - Production, J. Jones - Maintenance
70
35
70
49
Rejected due to
complexity of
different doors on
same line.
- 7/10/2015
Temp and press
limits were
determined and limit
controls have been
installed - control
charts show process
is in control Cpk =
1.85. - 7/13/2015
Automatic spray
timer installed operator starts
spray, timer controls
shut-off - control
charts show process
is in control Cpk =
2.05.
- 7/14/2015
CAUSES
Potential Cause(s) of
Failure
1.1.1.1 Manually inserted spray
head not inserted far
enough
Cause ID Cause #
1
280
70
% Reduction in Cause
RPN
75
Date:
9/1/2015
Page
of
Last Updated
Potential Failure
Last Updated Name Function
By
Mode
Reliability
9/1/2015 12:54 Front
Op. 70
Insufficient wax
Engineer
PM
Door
Manual
coverage over
L.H.
application specified surface
of wax
inside door/
cover inner
door, lower
surfaces
with wax to
specification
thickness.
8
Potential Effect(s) of
Failure
Allows integrity breach of
inner door panel.
Corroded interior lower
door panels.
Deteriorated life of door
leading to:
- Unsatisfactory appearance
due to rust through paint
over time
- Impaired function of
interior door hardware
175
35
80
Reliability
Engineer
Op. 70
Insufficient wax
Manual
coverage over
application specified surface
of wax
inside door/
cover inner
door, lower
surfaces
with wax to
specification
thickness.
70
70
Reliability
Engineer
Op. 70
Insufficient wax
Manual
coverage over
application specified surface
of wax
inside door/
cover inner
door, lower
surfaces
with wax to
specification
thickness.
392
49
87.5
Reliability
Engineer
Op. 70
Insufficient wax
Manual
coverage over
application specified surface
of wax
inside door/
cover inner
door, lower
surfaces
with wax to
specification
thickness.
ACTIONS
Action Action
Recommended
ID
#
Action(s)
1
1.1.1.1.1 Add positive depth
stop to sprayer.
Responsibility
Mfg. Engrg
Planned
Completion Date
7/8/2015
Actual
Actions
Last
Completion Date
Taken
Updated By
7/8/2015
Stop added,
Reliability
sprayer
Engineer
checked on
line.
Last
Updated
9/1/2015
12:45 PM
Date:
9/1/2015
Page
Potential Failure
Mode
Op. 70
Insufficient wax
Manual
coverage over
application specified surface
of wax
inside door/
cover inner
door, lower
surfaces
with wax to
specification
thickness.
Name Function
Front
Door
L.H.
of
7/10/2015
7/10/2015
Rejected
due to
complexity
of different
doors on
same line.
Reliability
Engineer
9/1/2015
12:46 PM
Front
Door
L.H.
Op. 70
Insufficient wax
Manual
coverage over
application specified surface
of wax
inside door/
cover inner
door, lower
surfaces
with wax to
specification
thickness.
70
Mfg. Engrg
7/13/2015
7/13/2015
Reliability
Engineer
9/1/2015
12:47 PM
Front
Door
L.H.
Op. 70
Insufficient wax
Manual
coverage over
application specified surface
of wax
inside door/
cover inner
door, lower
surfaces
with wax to
specification
thickness.
175
35
Maintenance
7/14/2015
7/14/2015
Temp and
press limits
were
determined
and limit
controls
have been
installed control
charts show
process is in
control Cpk
= 1.85.
Automatic
spray timer
installed operator
starts spray,
timer
controls
shut-off control
charts show
process is in
control Cpk
= 2.05.
Reliability
Engineer
9/1/2015
12:47 PM
Front
Door
L.H.
Op. 70
Insufficient wax
Manual
coverage over
application specified surface
of wax
inside door/
cover inner
door, lower
surfaces
with wax to
specification
thickness.
392
49
CONTROLS
Control ID
Date:
9/1/2015
Page
of
Potential Cause(s) of
Failure
Reliability Engineer 9/1/2015 12:48 PM Front
Op. 70
Insufficient wax coverage Allows integrity breach of inner Manually inserted spray head
Door L.H. Manual
over specified surface
door panel.
not inserted far enough
application
Corroded interior lower door
of wax
panels.
inside door/
Deteriorated life of door leading
cover inner
to:
- Unsatisfactory appearance
door, lower
due to rust through paint over
surfaces
time
with wax to
- Impaired function of interior
specification
thickness.
door hardware
Last Updated
Name
RPNi
RPNr
280
70
1.1.1.1.1
Detection
1.1.1.2.1
Prevention
175
35
1.1.1.2.2
Detection
175
35
1.1.1.3.1
Preventive maintenance
program to maintain heads.
Prevention
70
70
CONTROLS
Date:
9/1/2015
Page
of
1.1.1.3.2
Detection
70
70
1.1.1.4.1
Detection
392
49