You are on page 1of 6

315272970.

xls
GENERAL HOSPITAL AT NADIADI
SBC =
14
T/M^2

RAFT-SLAB
DL - DATA
COL
C34
C35
C44
C45
C46F
0
0
0
0
0

Fz
T
65.45
52.18
102.93
57.5
50.03
0
0
0
0
0
328.09

Mx
T-M
-0.34
-0.17
0.36
0.53
0.31
0
0
0
0
0
0.69

My
T-M
-0.01
-0.12
-0.79
0.02
0.29
0
0
0
0
0
-0.61

(X & Y W.R.T CENTRE OF C1)


X
Y
0
0
2.41
0
0
3.03
2.41
3.03
2.74
3.03
0
0
0
0
0
0
0
0
0
0

Fz
T
9.7
7.65
7.99
3.96
10.53
0
0
0
0
0
39.83

Mx
T-M
0.05
0.03
0.08
-0.02
0.09
0
0
0
0
0
0.23

My
T-M
-0.02
-0.01
-0.03
-0.03
0.002
0
0
0
0
0
-0.088

(X & Y W.R.T CENTRE OF C1)


X
Y
0
0
2.41
0
0
3.03
2.41
3.03
2.74
3.03
0
0
0
0
0
0
0
0
0
0

P*X

P*Y
0
0
125.7538
0
0 311.8779
138.575 174.225
137.0822 151.5909
0
0
0
0
0
0
0
0
0
0
401.411 637.6938

LL - DATA
COL
C34
C35
C44
C45
C46F
0
0
0
0
0

TOTAL
P*X(DL+LL) =

P*X
0
18.4365
0
9.5436
28.8522
0
0
0
0
0
56.8323

P*Y
0
0
24.2097
11.9988
31.9059
0
0
0
0
0
68.1144

TOTAL(DL+LL) =
Self wt. of Raft % =
REQ Area =

367.92
15
30.222

458.2433 705.8082
CGx = 1.245497

EQX+ - DATA
COL
C34
C35
C44
C45
C46F
0
0
0
0
0

Fz
T
-1.89
2.13
-9.2
31.84
-18.69
0
0
0
0
0
4.19

Mx
T-M
-0.15
-0.27
-0.3
-0.55
0.42
0
0
0
0
0
-0.85

My
T-M
-3.89
-3.47
-5.86
-5.14
-4.12
0
0
0
0
0
-22.48

PRESSURE(DL+LL) CASE-1
PR.=
12.12657 T/M^2
FACTORED PR. =
18.18985 T/M^2

CGy = 1.918374
L (II TO X) B(II TO Y)
Provided size =
4.10
7.40
SAFE
Area provided =

PRESSURE(DL+EQX)

CASE-2

pressure check
PR.
TOTAL PR
FACTORED PR. =

M/Z
1.113719 (@YY-CONSIDERED)
T/M^2
SAFE
T/M^2

P/A
10.95188
12.0656
18.0984

PRESSURE(DL+LL+EQX)

CASE-3

pressure check
PR.
TOTAL PR
FACTORED PR. =

M/Z
1.117964 (@YY-CONSIDERED)
T/M^2
SAFE
T/M^2

EQY+ - DATA
COL
C34
C35
C44
C45
C46F
0
0
0
0
0

Fz
T
-22.16
-21.31
35.66
30.87
10.81
0
0
0
0
0
33.87

Mx
T-M
5.54
5.65
14.06
12.86
9.67
0
0
0
0
0
47.78

My
T-M
-0.09
-0.01
-0.41
-0.18
0.27
0
0
0
0
0
-0.42

P/A
12.26467
13.38263
16.05916

PRESSURE(DL+EQY)
pressure check
PR.
TOTAL PR
FACTORED PR. =

CASE-4

P/A
M/Z
11.93013 1.29532 (@XX-CONSIDERED)
13.22544 T/M^2
SAFE
19.83817 T/M^2

PRESSURE(DL+LL+EQY)

CASE-5

pressure check
PR.
TOTAL PR
FACTORED PR. =

M/Z
1.301466 (@XX-CONSIDERED)
T/M^2
SAFE
T/M^2

P/A
13.24291
14.54438
17.45326

MAX.PR.(COE.1.5) = 13.22544 T/M^2

CASE - 1,2 OR 4

MAX.PR.(COE.1.2) = 14.54438 T/M^2

CASE - 3 OR 5

Page 1 of 6

30.34

M^2

Zxx =

37.41933 M^3

Zyy =

20.73233 M^3

RAFT-SLAB

315272970.xls
GENERAL HOSPITAL AT NADIADI
SBC =
14
T/M^2

DESIGN PRESSURE = 13.22544 T/M^2

Page 2 of 6

RAFT-SLAB

315272970.xls
GENERAL HOSPITAL AT NADIADI
SBC =
14
T/M^2

SLAB TH. CHECK :


CLEAR CANTILEVER =
CLEAR COVER =

131

CM

CM

CRITICAL SECTION FOR S.F. ( AT EFF.DEPTH FROM SUPPORT) =


FACTORED S.F. AT CRI.FACE =

17.18 T

SHEAR STRENGTH =

12.432 T

FACTORED S.F. AT FACE =

25.988

Page 3 of 6

SLAB DEPTH =

50

CM

RE.BAR DIA MM =
EFF. DEPTH =

12
CM
44.4 CM

UNSAFE-INCRASE DEPTH

315272970.xls