You are on page 1of 1

Edition I/2007

RAIL-MOUNTED TEMPERATURE TRANSMITTER TYPE ATL

? Programmable sensor type PT100 i Ni100

? Programmable measuring range.


? Resistant thermoresistance line compensation
( 3 wire line)
? Output signal 420mA
? rail- mounting system.

Application and function


The temperature economical transmitter ATL is applicable to converting
resistance of temperature sensor to standard current signal 420mA.
Most of parameters such as: sensor type, input signal, measuring range
may be adapted by user for specific requirements of his measuring system.
The transmitter is programmed using PC with RS converter and Aplisens
AT configuration software.
If you define type of sensor, measuring range in the order, then the
transmitter is programmed with required parameters and their values are
printed on serial number label.
Transmitter for rail mounting.

62

Input signal
Limit process
Min. measuring range
Output signal
Power supply
Load resistance
Alarm signal
Accuracy for R>20
Thermal error
Ambient temperature
Error due to supply voltage
changes

Pt 100, Ni 100
20 <R<380
10
4 20 mA
1036V DC
Ro[k]<(Uz 7V)/25mA
23mA or 3,8mA
0,2%
0,1% / 10C
-25+80C
0,1%

Ordering procedure.

91

Technical data

Electrical diagrams

ATL /___/____C/___
RS232

Sensor type:Pt100,Ni100

Alarm signal
Konwerter

Measuring range

GND Rx

Tx

Example: temperature transmitter ATL, sensor type Pt100,


measuring range 0100C, alarm signal 23mA.

I
+

3
2

Rt

WE

ATL/Pt100/ 0100C/23mA

Ucc

50

WY

APLISENS Ltd. 03-192 Warsaw, 7 Morelowa Str. tel. (+48-22) 814-07-77


fax (+48-22) 814-07-78, www.aplisens.pl, e-mail: export@aplisens.pl