You are on page 1of 1

JMS Com. e Ind. de Equipamentos Ltda.

Phone : (16) 3042-1620


Fax : (16) 3042-1620
Customer : Internal
Project : Fan Selection by Elton Barroso
Item 1 - Ref : Temp 1
Gas Properties :
Barom Pressure :
Operating Temp :
Humidity :
Specific Gravity :
Inlet Density :

10331.9
20
50
1
1.2001

mm wg
Deg.C.
%

Quote Ref : Centrix Temp


12/08/2014

8
7
6

Kg/m3

Fan Static Efficiency


Fan Total Efficiency
Duty : 250 M3/MIN @ 120 MM WG @ 20 Deg.C.

Fan Power
kw

Duty Required :
Inlet Volume Flow :
Fan Static Pressure :
Inlet Pressure :
Outlet Pressure :

250 m3/min
-0 mm wg
120 mm wg

Fan Selected :
SWSI-A219-620/100-100
1709 Rpm
Speed :
Impeller :
620 mm
Fan Class :
2
Maximum Rpm :
2156 Note 1
Fan Shaft Power :
@ 20 Deg C :
@ Duty Temp :

7.05 kW
7.05 kW

Tip Speed :
Inlet Velocity :
Outlet Velocity :
Temp Rise :

55.5
14.1
12.4
1.4

Noise Details :

2
1

12

16

20

24

28

32

36

40

180

90
Eff %

160

80

140

70

120

60

100

Fan Static + Total Pressure


MM WG

50

Total Eff %

m/s
m/s
m/s
Deg.C.

80

40

60

30

40

Static Eff %

20

20

Pt

10

12

16
20
24
28
Volume Flow M3/MIN X 10

32

36

40

Prog V390.38

63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Total

Internal SWL dB
Free Inlet SPL dBA
Free Outlet SPL dBA

99
57
59

96
68
71

98
80
83

92
82
84

85
78
80

82
76
78

80
74
76

74
66
68

103
86
88

Outside Casing dBA

55

63

69

69

65

65

63

55

74

Motor noise is NOT included in the figures above.


Sound Pressure levels (SPL) assume Free Field Hemispherical Radiation at 1 metre(s)
Breakout at 1 metre from 5/3 mm thick casing(inside Near Field range).
Casing levels assume the inlet / outlet are ducted and noise does not breakout through duct.
All values are averages. Free Inlet assumes that outlet is ducted and vice versa.

Note 1) The max rpm may require a larger motor and/or upgraded drive components.

You might also like