You are on page 1of 1

750 V 70C THW

0.6/1(MEA
kV CVTYPE A)

PVC -INSULATED,
SINGLE-CORE
2 CORES
CROSSLINKED
POLYETHYLENE POWER CABLE

BANGKOK CABLE 750 V 70 C PVC THW


BANGKOK CABLE 0.6/1 kV CV

1
Construction
2 3 4
1. Conductor
: Solid or concentric stranded annealed copper
Construction

2
5

Reference Standard :
Reference
Standard :
2. Insulation 1. Conductor
: Polyvinyl chloride
(PVC)stranded or Compacted stranded
TIS 11-2531,
TABLE 4
: Concentric
White, Black,annealed
Red, Blue,
Green or other colour
copper

2. Insulation
Colour code
3. Filler
4. Binding tape
5. Sheath

: Cross-linked polyethylene (XLPE)


: Red, Black

IEC 60502-1

Classification
MaximumClassification
conductor temperature

: 70C
: Polypropylene (Non-hygroscopic material) Maximum circuit voltage
: 750 V : 90C
Maximum conductor temperature
: Polyester tape and/or Spunbond tape
AC test voltage
: 2,500 V: 1,000 V
Maximum circuit voltage
: Polyvinyl chloride (PVC), Black colour
AC test voltage
: 3,500 V

Application
Application
For building
wiring, installation on insulator or in raceway, dry location.
For general purpose power distribution in dry or wet location,
installation exposed in conduit or duct or direct burial in ground.

Conductor
Thickness
Overall
Insulation
Current
Cable
Standard
No. & dia.
Diameter Thickness
of Thicknessdiameter
resistance
rating
weight
length Standard
Conductor
Current
rating
Overall
DC.
Insulstion
Cable
in free air
of wires
insulation
at 70C
Cross- No. of Diameter
of
of
diameter conductor resistanceat 40inCfree air direct burial weight
length
sectional wires
insulation sheath
resistance at 20Cambient
at 40C in ground
2
area
at
20

C
ambient
at 30C
mm
No./mm
mm
mm
mm
M-km
A
kg/km
m
(Max.)
(Min.)
(Approx.)
2
0.5
1/0.80
0.80
3.0mm
0.0715 M-km 11 A
11A
100/C m/drum
kg/km
mm
mm 0.8
mm
/km
mm
1
1/1.13 (Min.) (Approx.)
1.13
0.8 (Nominal) (Approx.)
3.3
0.0141 (Min.) 16
17
100/C
(Nominal)
(Max.)
(Approx.)
1
7/0.40
1.20
0.8
3.5
0.0135
16
17
100/C
1.5
1.56
0.7 0.8
1.8
12.1
120
1.5
1/1.38 7
1.38
3.610.5
0.0123 2,550 21 25
2233
100/C 500
2.5
2.01
0.7 0.8
1.8
7.41
160100/C 500
1.5
7/0.50 7
1.50
3.811.5
0.0116 2,100 21 34
2244
41/1.78 7
2.55
0.7 0.8
1.8
4.61
210
2.5
1.78
4.012.5
0.0102 1,700 29 44
3158
100/C 500
2.5
7/0.67
2.01
0.8
4.3
0.0093
29
31
100/C 500
6
7
3.12
0.7
1.8
14.0
3.08
1,450
57
73
270
4
1/2.25
2.25
0.9
4.8
0.0094
39
50
10
6
3.72
0.7
1.8
15.0
1.83
1,250
77
97
370100/C 500
4
7/0.85
2.55
0.9
5.2
0.0085
39
50
100/C
167/1.04 6
4.69
0.7 0.9
1.8
1.15
520
3.12
5.817.0
0.0073 1,000 51 100
75125
100/C 500
6
257/1.35 6
5.90
0.9 1.1
1.8
0.727
165
770100/C 500
10
4.05
7.220.5
0.0069 1,050 70 135
120
35
6
6.95
0.9
1.8
22.5
0.524
900
165
195
1,020
16
7/1.70
5.10
1.1
8.4
0.0057
96
180
100/C 500
25
6.42
10.526.0
0.0054 850 127 205
290
100/C 500
507/2.14 6
8.33
1.0 1.3
1.8
0.387
235
1,360
35
19/1.53 12
7.65
11.529.0
0.0047 800 157 255
380
100/C 500
70
9.73
1.1 1.3
1.8
0.268
290
1,860
50
19/1.78
8.90
1.5
13.5
0.0046
191
540
500/D
95
11.43
1.1 1.5
1.9
0.193
350
2,500
70
19/2.14 15
10.70
15.533.0
0.0039 700 244 315
720
500/D 500
120
18
12.95
1.2
2.0
36.5
0.153
650
365
400
3,130
95
19/2.52
12.60
1.7
18.0
0.0038
297
1,000
500/D 500
150
14.27
1.4 1.7
2.1
0.124
450
3,850
120
37/2.03 18
14.21
19.540.5
0.0034 700 345 415
1,240
500/D 500
15.75
21.545.0
0.0034 700 397 485
1,520
500/D 400
150
37/2.25 30
185
15.98
1.6 1.9
2.3
0.0991
505
4,820
185
37/2.52
17.64
2.1
24.0
0.0034
453
1,900
500/D 300
240
34
18.47
1.7
2.5
51.0
0.0754
650
580
585
6,280
240
61/2.25
20.25
2.3
27.0
0.0033
535
2,480
500/D
300
20.68
1.8 2.5
2.6
0.0601
665
7,770
300
61/2.52 34
22.68
30.056.0
0.0032 600 617 675
3,100
500/D 250
400
23.39
2.0 2.7
2.9
0.0470
750
9,900
400
61/2.85 53
25.65
33.563.5
0.0030 600 741 790
3,950
300/D 200
500
61/3.20
28.80
3.1
38.0
0.0031
854
5,150
300/D
B 32
C =Revision
Packing
: 00,in coil
May 2010
D = Packing in drum
B 2B 32
Revision : 00, May 2010
Crosssectional
area

You might also like