6.0
5.5
5.0
4.5
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
0 10 20 30 40 50 60
Beam Current (mA)
R SD N P
------------------------------------------------------------
0.99316 0.16799 5 <0.0001
------------------------------------------------------------
Test 1
Test 2
ASSUMING Sputter Yield BN – 0.5
ASSUMING 0.8333 of beam current is on the target. (This assumption comes from
the observation of measuring 25mA on the Aluminum target when the Ion Source
power supply reads 30mA).
- NOTE: Hrmmm….. this is interesting. With a target of size 15x14 cm, and a
vacuum chamber diameter of 20cm, the target takes up 0.833 of the cross sectional area
of the chamber. – Coincidence?
CRDS
Model
1.40E+010
1.20E+010
1.00E+010
[BN] (cm )
-2
8.00E+009
6.00E+009
4.00E+009
20 30 40 50 60
Beam Current (mA)
CRDS (cm-2) MODEL (cm-2) Beam Current (mA) CRDS PeakFit Area obtained from:
4.36E+09 4.46E+09 20 Test2
6.78E+09 6.69E+09 30 Test1
8.00E+09 8.92E+09 40 Test1
1.07E+10 1.12E+10 50 Test1
1.33E+10 1.34E+10 60 Test2