POWER SUPPLY CHECK AND FIND «PROT» FAILURE

All of the following tests must be carried out with the MAINS switched OFF.

Any operations carried out with the MAINS switched ON may lead to components
being destroyed.

to analyse a «PROT» fault condition it is possible to use the following test configuration.
In this configuration the power supply will be working with its normal regulation loop, the deflection stage
and any "PROT" information is disabled in order to locate the cause of the problem.

- MAINS switched «OFF»


- CP170 short-circuited (K/6)*
- JL010 removed (M/8)* or desolder Pin 6 of DST (LL08)
- Connect a R= 75 Ohms (4W) between +Vs and -Vs (L-M/4-5)*

- Switch «ON» TV : Measure the following voltages.

U Syst : 50 Hz 50Hz 50Hz 100Hz 100 Hz 100 Hz


131V 132 137V 134V 137V 140V
Usyst (P/5)* (V+/-5V) 131.5 133 138 134.3 141 140
U vert / CP130 ( P/4)* (V) 13 14.2 14.2 12.7 12.8 11.8
+Us / -Us (L/5-4)* (V) 6.4 6.4 6.4 8 8.3 6
7V / CP140 (J/3-4)* (V) 4.3 8.6 8.6 6.8 7.4 6.4
10V SBY/ K DP133 (N/5)* (V) 10.6 11.2 11.2 10.2 10.4 9.3
Vcc1 / 44-IV001 (J/7)* (V) 7.8 7.9 7.9 7.9 7.9 7.8
UVFB / K DL043 (K/8)* (V) 13.3 14.5 14.5 12.7 12.8 11.1
13V / CL042 (J/8)* (V) 0 0 0 0 0 0
200V / CL046 (P/6)* (V) 0 0 0 0 0 1.1
5V / CP143 (H/3)* (V) 0 0 0 0 0 0.2

(*) Components location

safety circuit block diagram only