You are on page 1of 2

SOLARWATT P220-96 GET AK

ENGLISH
GLASS-FOIL-SOLAR-MODULE

SOLARWATT modules supply the highest yield


through optimally matched materials and
sorting in tight performance classes. Tested
source material, the most careful processing
and the strictest test procedures guarantee the
longevity of the modules. SOLARWATT modules
are exclusively manufactured in Germany.
The solar module SOLARWATT P220-96 GET AK
for grid-connected plants connects
SOLARWATT‘s familiar high quality with
efficient installation and an outstanding cost-
performance ratio.

» polycrystalline solar cells with an efficiency


of up to 16%
» frame with hollow chamber profile and
drainage opening
» high mechanic stability and torsional
stiffness
SOLARWATT AG
» insulated and against reverse polarity Maria-Reiche-Str. 2a
protected connectors 01109 Dresden, Germany
» plus-oriented performance sorting Tel. +49 351 8895-0
(-1 Wp to +4 Wp) Fax +49 351 8895-111
info@solarwatt.de
» Max. system voltage 1000 V
www.solarwatt.de
» cells and used materials are tested
disengaged on the basis of test routines CERTIFIED ACC. TO::
» quality test during all manufacturing steps DIN EN ISO 9001 und 14001
» 25 years warranty to power output acc. to
Warranty Conditions
» resource-conserving, patented packing
system QUICKSTAXX ®

[ NOMENCLATURE OF NAMES OF SOLARWATT MODULES ]

P 220 - 96 GET A K

TYPE OF CELLS BENCHMARK FOR NO. OF CELLS LAYER CONSTRUKTION FRAME CONNECTION
A = amorphous silicon MODULE PERFORMANCE E = EVA A = Aluminium B = Ribbon
M = monocristalline silicon Nominal Power and G = Glass E = Stainless Steel D = Box
P = polycristalline silicon performance class are K = Synthetics L = Laminate K = Cable
specified in the data T = Tedlar-composite film (without frame)
sheet
GLASS-FOIL-SOLAR-MODULE | SOLARWATT AG |

SOLARWATT APPOINTED DEALER:

Subject to change without notice .


SOLARWATT P220-96 GET AK
TECHNICAL DATA

DIMENSIONS GENERAL DATA


1610 ± 2 mm Module Technology Glass-Foil-Laminate; Aluminium Frame
Cover material High transparent solar glass (tempered), 4 mm
Encapsulation EVA-Solar Cells-EVA
Back material Tedlar-Polyester-Tedlar, white
No. and Type of Cells 96 polycrystalline solar cells
1060 ± 2 mm

Dimensions of Cells 125 x 125 mm


Cables Junction box with tyco plug connector cables
2 x 1,20 m/4 mm²
Bypass-Diodes 4 pcs.
Application Class Class A at IEC 61730
Ø 9mm
Earthing bores
810 ± 0,5 mm Dimensions (LxWxH) 1610 x 1060 x 50 mm
Weight 24 kg
Max. System Voltage 1000 V
IP Protection Level IP 65
Mechanical Ratings Suction pressure of 2400 Pa approved
(Wind speed 130 km/h with safety factor 3)
Load of 5400 Pa approved
IEC 61215 Ed.2,
Qualifications
IEC 61730 (incl. Safety Class II)

ELECTRICAL DATA (STC)  STC: Standard Test Conditions: measurement conditions: Radiation strength 1000 W/m2, spectral distribu-
tion AM 1.5, temperature 252 °C, in accordance with EN 60904-3

Specification SOLARWATT P220-96 GET AK


Nominal Power Pmax 210 Wp 215 Wp 220 Wp 225 Wp 230 Wp 235 Wp
Nominal Voltage Umpp 47,2 V 47,3 V 47,4 V 47,6 V 47,8 V 48,0 V
Nominal Current Impp 4,46 A 4,55 A 4,65 A 4,73 A 4,82 A 4,90 A
Open Circuit Voltage UOC 58,2 V 58,3 V 58,5 V 58,7 V 58,9 V 59,1 V
Short Circuit Current ISC 5,00 A 5,06 A 5,11 A 5,16 A 5,22 A 5,29 A
IR* 15 A 15 A 15 A 15 A 15 A 15 A
Measuring tolerances P max ±5 %;
*Reverse current power rating: Operation of the modules with an external power source is only permitted with a string fuse with a release current of < 2 x ISC @ NOCT.

Reduction in the module efficiency with reduction in radiation strength of 1000 W/m2 to 200 W/m2 (25°C): 4 ±2 % (relative) / -0,6 ± 0,3 % (absolute).

ELECTRICAL DATA (NOCT) NOCT: Normal Operation Cell Temperature, measurement conditions: Radiation strength 800 W/m2, AM 1.5,
temperature 20 °C, wind speed 1m/s, electrical open-circuit operation

Specification SOLARWATT P220-96 GET AK


Nominal Power Pmax 153 Wp 156 Wp 160 Wp 163 Wp 167 Wp 171 Wp
Nominal Voltage Umpp 43,1 V 43,2 V 43,3 V 43,5 V 43,7 V 43,9 V
Open Circuit Voltage UOC 54,1 V 54,2 V 54,4 V 54,6 V 54,7V 54,9 V
Short Circuit Current ISC 4,04 A 4,09 A 4,13 A 4,17 A 4,22 A 4,28 A

CHARACT. 1000 W/m2 THERMAL FEATURES


LINE 800 W/m2

600 W/m2
Operating Temperature Range -40 … +80 °C
Voltage charact. Ambiente Temperature Range -40 … +45 °C
line with different 400 W/m2
Temperature Coefficient of PN -0,46%/K
irradiations 200 W/m2
Temperature Coefficient of UOC -0,35%/K
Temperature Coefficient of ISC 0,05%/K
Performance class 235 Wp
NOCT 45°C

[This data sheet conforms to DIN EN 50380:2003; 2008/11]