Summer Training 2010 in Dholpur Combined Cycle Power Project (DCCPP)
Summer Training 2010 in Dholpur Combined Cycle Power Project (DCCPP)
in
Dholpur Combined Cycle Power
Project (DCCPP)
Submitted By:
JITESH SHARMA
INTRODUCTION
To Dholpur Combined Cycle
Power Project (DCCPP)
DCCPP is project of Rajasthan Vidhut Utpadan
Nigam Ltd setup in 2007
Less pollution.
COMBINED CYCLE POWER PLANT
ADVANTAGE -:
High thermal efficiency
Low water requirement
Environmental friendliness
Fast start-up
Low installation cost
COMBINED CYCLE POWER PLANT
Disadvantage-:
Low thermal efficiency in open cycle
Higher cost of generation
Higher maintenance cost
PROCESS
First of all 800,000 cubic feet per minute air is
inserted into the gas turbine where it is
compressed , mixed with natural gas and
ignited in combustion chamber . Thus the
pressure generates. This pressure spins the
turbine blades. These blades are attached to a
rotar, which spins the generator and make
185 mw electricity.
BASIC CIRCUIT DIAGRAM OF PLANT
PLANT LAY OUT
HEAT RECOVERY STEAM
GENERATOR (HRSG)
It is a heat exchanger that recovers heat from a hot
gas stream
I
Switch A D I I I O
P O O O
Switch B
U
S
D I I I
I
MAXNET Network P O O O
U G
MAXSTATION
N
I I I I A
O O O O L
S
DPU(Distributed Processing Unit)
10 ms I/O and function Block processing time
8500 function block for high capacity complex
control
Multiple execution speed to make the best use
of the processor
Standard serial port link for communication
Dual 100 mbps highway connection for high
speed
Physical Capabilities
Addresses: 255
I/O Bus Length: 30 ft
I/O Bus Length With BEM: 6,500 ft
Number of I/O Modules per DPU: 125
Number of SOE Modules per DPU: 32
Operating Ambient Temperature: 0°C to +60°C
(local to DPU)
Relative Humidity: 5% to 90% non-condensing
Control Processor: National Geode, 128 mByte RAM,
64 MByte Compact Flash
Electrical
System Power: 24 ±4 Vdc
Current: 1.2 A @ 24 Vdc
Model No. PDP401 - maxDPU4F
CONTROL PANEL HARDWARES
Connectors
240V AC to 24V DC converter
Rack 1
Primary DPU
Rack 2
Sec. DPU
IO modules
Rack 3
Power Supply Module
DPU 4F
Mode Switch
Run - F
Network Healthy
Network A port
Network B port
Backup Indication
DPU Backup Cable
Reset Button
Takeover Button
DONGLE CARD
Dongle Card
Physical Characteristics
The maxDPU4F resides directly on the
maxNET communications network without the
need for servers. It is fully compatible with
max DNA, max PAC I/O,
MAX 1000 + PLUS and most MAX1000 Model
564 I/O. The maxDPU4F mounts in a single
wide slot in a max PAC 8 PAC rack.
DC SYSTEM & PLC COMMUNICATION
SWITCH YARD
BATTERY BANK
ELECTROLYTE-
1.mixture of acid & pure
water
2.genral proportion is
85% water & 15% acid.
PLCC (Power line
carrier
communication )
Working of PLCC
The voice freq. if converted into electrical
signal these signal are super imposed &
transmitted through a coupling capacitor (cc).
At the receiving and wave trap don’t allow the
modulated signal to enter power ckt. through
CC the signal is given to the line matching
unit . After matching freq. filtration of signal is
done.
Various electronics components & their
utilization
Simulation of section-simulate a value while online is
used to isolate a proper section . In process machine
works on simulate value instead of out come data.
RTD (Resistance temp detector) – RTD modules or
JITESH SHARMA
THANK YOU