You are on page 1of 2

KILBURN ENGINEERING LTD.

CLIENT ONGC / NPCC

DEMISTER

ITEM N-15-V-440 JOB CONSULTANT KOS- 128 SHEET 2 OF 3 NO. B SERIES AND N15 & N16 06 D.S. PROJECT KOS-128-ME-202 REV. 2 WELL PLATFORMS PROJECT NO. 1 SERVICE KNOCK OUT DRUM 2 FLUID HANDLED HYDROCARBON GAS / LIFT GAS VESSEL ID 3 538 MM OPERATING PRESSURE 4 30 - 78 Kg/cm2 G OPERATING TEMPERATURE 5 11.37- 18.51 C 6 VAPOUR CONDITION AT PRESSURE & TEMPERATURE VAPOUR FLOW RATE 7 104.2 105.6 KG/HR VAPOUR DENSITY 8 29.31 - 86.93 KG/M3 VAPOUR VISCOSITY 9 0.01164 0.01426 CP 10 VAPOUR MOLECULAR WEIGHT 20.20 20.76 11 LIQUID CONDITION AT PRESSURE & TEMPERATURE 12 DROPLET SIZE RANGE MIN. 10 MICRON. LIQUID FLOW RATE 13 25 LPH LIQUID DENSITY 14 519 609.7 KG/M3 LIQUID VISCOSITY 15 0.1280 0.2108 CP SURFACE TENSION 16 8 -12.95 DYNES / CM 17 DEMISTER PERFORMANCE REQUIREMENTS 18 SEPARATION EFFICIENCY 98% LIQUID. 10 MICRON MAX. ALLOWABLE PRESSURE DROP 19 100 MMWC 20 DESIGN DATA DESIGN PRESSURE 21 105 Kg/cm2 G DESIGN TEMPERATURE 22 75 C 23 MATERIAL OF CONSTRUCTION SS316L ( NOTE - 2) 24 REFERENCE EQUIPMENT DATASHEET NUMBER KOS-128-ME-202 Rev.2

NOTES: 1. LIQUID CARRYOVER IN GAS OUTLET OF KNOCK OUT DRUM SHALL BE LESS THAN 13.4 LIT/MMSCM OF GAS. 2. MATERIAL SHALL MEET THE REQUIREMENT OF NACE MR-01-75(ISO 15156) (LATEST) 3. SIZE OF DEMISTER BY VENDOR 4. DIMENSIONAL DRAWINGS SHALL BE PROVIDED

0 REV

APPROVAL DESCRIPTION

DATE

PPDY BY

APD BY

REV

DESCRIPTION

DATE

PPD BY

APD BY

You might also like