Negligible difference between systems Mica paper with glass fabric carrier and without resin
class earner
Yes
Number of insulation lavers Internal potential grading for optimized field distribution in the main insulation
Corona protection \'lith tapes
Yes Yes
Yes
Main insulation dielectric strength Partial Discharges within the insulation (PO levet Advantages
Very low. no micro voids: Pressed - si ghtly higher due PD/single bar lower than 2 nC to lack of vacuum Void-free insulation by removal of air through the vacuum process Penetration of impregnating resin into the insulation to fill the voids Minimization of corona activity Achieve verylow levels of PO Low viscosity resin during heating results in very few retained voids Insulation system results in very high dielectric strength l ow POsystem High temperature capabuty