2009 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to Andrew Solutions products or services. TP- 103194-EN (6/09)
Introduction
As wireless telecommunication services continue to expand, wireless providers are deploying more and more base station antennas in order to meet the growing demand. As a result, antenna towers and support structures are being pushed to the limits of their load capacity. It is therefore important for wireless service providers and tower owners to understand the impact that each base station antenna has on the overall tower load. Base station antennas not only add load to the towers due to their mass, but also in the form of additional dynamic loading caused by the wind. Depending on the aerodynamic efficiency of the antenna, the increased wind load can be significant. Its effects figure prominently in the design of every Andrew base station antenna. This paper focuses on how Andrew Solutions determines wind load values and Effective Drag Areas published in its catalogs and technical specifications. Figure 1. Basic Wind Speed Design Factors. In determining wind load values, Andrew uses standalone antennas subjected to 150 kilometers per hour (93 miles per hour) winds directed from both front and side. The resulting wind load values can then be used to compare aerodynamic efficiencies between various antenna profiles. These should be used as a starting point for loads used in the tower design and not as absolute maximum wind load values. Additionally, there are other location-specific factors to consider when calculating antenna wind load. These include but are not limited to: geographic location, tower height, tower or building structure, surrounding terrain, and shielding effects from other mounted antennas. For example, some regions have maximum wind speeds of 140km/h while others may be as high as 240km/h (Figure 1). Using Andrew calculated values at 150km/h may cause the tower to be over-designed or even worse, greatly under-designed. Industry standards such as TIA-222-G "Structural Standards for Antenna Supporting Structures" take into account these additional factors.
Wind Load Calculation Wind load is calculated using the following equation:
Fw =
( C dp ) V 2 A 2
Where: Fw = Force due to wind (lbf, N) = Air Density (.075lb/ft3, 1.22 kg/m3) Cdp = Profile Drag Coefficient (from text or experimental data) = Length/Width Aspect Ratio Correction Factor V = Wind Velocity (ft/s, m/s) A = Cross Sectional Area Normal to wind direction (length*width) (ft2,m2)
Visit our Web site at www.commscope/andrew.com or contact your local Andrew Solutions representative for more information.
2009 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to Andrew Solutions products or services. TP- 103194-EN (6/09)
Drag Coefficient
The drag coefficient is a key component in calculating wind
load on an antenna. Its value varies for each antenna shape and must be determined experimentally or with the aid of Computational Fluid Dynamic (CFD) analysis. If the drag force on an antenna is known, the antennas drag coefficient can be calculated using the following equation.
C da
Fw = 1 V 2 A 2
The area used in this equation is the cross sectional area perpendicular to the wind direction. A variety of resources list experimental drag coefficients of basic shapes and profiles. This data provides a good estimation of simple antenna profiles and is often used by Andrew as a starting point during testing and design. The experimental data is then confirmed with both wind tunnel testing and CFD analysis. Table 1 lists drag coefficients of various antenna profiles.
It is important to note that the drag coefficient of antennas with round and cylindrical profiles are more dependant on the Reynolds number than profiles with abrupt corners. For this reason, values listed are based on Reynolds numbers between 104 and 105. Once the correct drag coefficient has been determined for a given profile, antennas can be scaled up or down and new wind loads calculated.
Visit our Web site at www.commscope/andrew.com or contact your local Andrew Solutions representative for more information.
2009 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to Andrew Solutions products or services. TP- 103194-EN (6/09)
Cda = Cdp
Fw = 1 2 (Cdp ) V 2 A
L/W
2 .60
5 .63
8 .70
12 .74
20
30
40
50
Length/Width
Visit our Web site at www.commscope/andrew.com or contact your local Andrew Solutions representative for more information.
2009 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to Andrew Solutions products or services. TP- 103194-EN (6/09)
Visit our Web site at www.commscope/andrew.com or contact your local Andrew Solutions representative for more information.
2009 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to Andrew Solutions products or services. TP- 103194-EN (6/09)
Setting the antenna wind load at a given wind speed equal to the flat plate wind load
.5 V 2 Aa C da = .5 V 2 A fp C dfp
Solving for Afp
A fp =
Aa C da C dfp
Where: Afp = equivalent flat plate Aa = Antenna projected area Cda = Drag Coefficient of Antenna Cdfp = Drag Coefficient of flat plate
It is critical to understand not only the reference area of the antenna being analyzed, but the flat plate reference area as well. Is it circular, square, rectangular, or infinitely long? The shape of the reference flat plate can make a significant difference in the area calculated as shown in Table 2. Table 2. Equivalent Flat Plate Areas Versus Reference Shape.
Visit our Web site at www.commscope/andrew.com or contact your local Andrew Solutions representative for more information.
2009 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to Andrew Solutions products or services. TP- 103194-EN (6/09)
A more accepted practice is to assume that the flat plate reference area has a drag coefficient of 1.0, meaning the equivalent flat plate area is equal the antennas drag coefficient multiplied by the antennas projected area perpendicular to the wind direction. This is referred to by Andrew Solutions as the Effective Drag Area (EDA). In order to stay consistent with the latest revision of TIA-222, Andrew has adopted the following calculation for EDA.
EDA = Cda A
Where:
EDA = Effective Drag Area (ft2, m2) Cda = Antenna Drag Coefficient A = Projected Area of the Antenna (ft2, m2)
The more aerodynamic the antenna profile, the smaller the Effective Drag Area, as seen in Figure 4. Figure 4. Projected Area And Drag Area.
antenna wind load. The streamlined design of the Andrew ATM200 actuator allows it to be considered as part of the cable run when calculating tower loads (Figure 5).
Visit our Web site at www.commscope/andrew.com or contact your local Andrew Solutions representative for more information.
2009 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to Andrew Solutions products or services. TP- 103194-EN (6/09)
Where: F=Static Load (lbf) V=Velocity (mph) A=Projected Area (ft2) Cylindrical Profile
This method assumes a flat plate cross section (no force reduction for curved surfaces) and includes a 30% margin to account for the added effects of wind gusts and ice. Figure 6. Wind Load And Tunnel Testing.
Conclusion
In many cases, the cost of leasing tower space is largely based on how much loading a base station antenna adds to the tower structure. Wireless operators often use wind load data presented by base station antenna manufacturers when deciding on which antennas to deploy. Therefore, it is important for operators and tower owners to fully understand how wind load data is calculated so that fair comparisons can be made between various antenna designs. This paper presents the methods in which Andrew Solutions determines frontal and lateral wind load values, as well as the effective drag area. These methods are backed up by full scale wind tunnel testing, as well as computational fluid dynamic simulation. Wind load data provided by Andrew Solutions is accurate and reliable, giving wireless service providers the tools to make the best antenna purchase decision.
Visit our Web site at www.commscope/andrew.com or contact your local Andrew Solutions representative for more information.
2009 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to Andrew Solutions products or services. TP- 103194-EN (6/09)
Appendix A
Comparison of wind tunnel testing to CFD simulations and Andrew wind load calculator.
120.0
100.0
60.0
40.0 Wind Tunnel 20.0 ANSYS CFX Hand Calc 0.0 30 40 50 60 70 80 90 100 110 120 Wind Speed (mph)
50.0
30.0
180.0 160.0 140.0 120.0 Wind Load (lbf) 100.0 80.0 60.0 40.0 20.0 0.0 30 40 50 60 70 80 90 100 110 120 Wind Speed (mph) Wind Tunnel ANSYS CFX Hand Calc