You are on page 1of 40

Gulf Cable & Electrical Ind. Co.

INTRODUCTION
Gulf Cable and Electrical Industries Company K.S.C. (Gulf Cable) is the only domestic manufacturer and exporter
of power cables, control cables, telecommunication cables and overhead conductors in Kuwait. We were established
in March 1975 and have been listed on the Kuwait Stock Exchange since 1984. Our manufacturing operations
commenced in 1979.
We embarked upon a massive restoration of our plant & it's facilities during the early 90's when state-of-the-art
machinery and testing equipment were acquired. Thereafter, new machines are recurrently being introduced to
enhance our production capacity and product range. The new machines and equipment have numerous built-in
functions and features assuring precision and consistency of the highest standard.
On a regular basis, we develop new products and enhance our existing ones. At Gulf Cable we pay utmost attention
to product quality, and to ensure this, we have adapted a comprehensive Quality Assurance System that complies
with international standards.
Quality has always been our top priority and meeting customer's expectations has been our prime objective. The
very basis on which we have earned the confidence of our clientele.
At Gulf Cable we follow stringent quality standards which go beyond stipulatations of international specifications,
rendering long term performance and reliability to our products during their service life.
At Gulf Cable we always aim for the best. When most of the cable manufacturers in the region settled for ISO:
9002, we stand out with ISO 9001, which recognizes our ability for Design and Development as well. We are also
acknowledged by the Kuwait Quality Mark issued by the Ministry of Commerce and Industries.

Gulf Cable & Electrical Ind. Co.


CONTENTS
INTRODUCTION
PRODUCT RANGE

I-II

PRODUCT DATA TABLES


XLPE INSULATED MEDIUM VOLTAGE CABLES
Single Core Cables 3.8 /6.6 KV Cu/SC/XLPE/SC/AWA/PVC

Three Core Cables 3.8 /6.6 KV Cu/SC/XLPE/SC/SWA/PVC

Single Core Cables 6.35/11 KV Cu/SC/XLPE/SC/AWA/PVC

Single Core Cables 6.35/11 KV Cu/SC/XLPE/SC/CUT/PVC/AWA/PVC

Three Core Cables 6.35/11 KV Cu/SC/XLPE/SC/SWA/PVC

Three Core Cables 6.35/11 KV Cu/SC/XLPE/SC/CUT/PVC/SWA/PVC

Three Core Cables 6.35/11 KV AI/ SC/XLPE/SC/SWA/PVC

Three Core Cables 6.35/11 KV AI/SC/XLPE/SC/CUT/PVC/SWA/PVC

Single Core Cables 8.7 / 15 KV Cu/SC/XLPE/SC/AWA/PVC

Single Core Cables 8.7 / 15 KV Cu/SC/XLPE/SC/CUT/ PVC

10

Single Core Cables 8.7 / 15 KV Cu/SC/XLPE/SC/CUT/PVC/AWA/PVC

11

Three core Cables 8.7 / 15 KV Cu/SC/XLPE/SC/CUT/ PVC

12

Three Core Cables 8.7/15 KV Cu/SC/XLPE/SC/CUT/PVC/SWA/PVC

13

Three Core Cables 8.7/15 KV AI/ SC/XLPE/SC/CUT/PVC/SWA/PVC

14

Single Core Cables 12.7/22 KV Cu/SC/XLPE/SC/CUT/PVC

15

Three Core Cables 12.7/22 KV Cu/SC/XLPE/SC/CUT/PVC

16

Three Core Cables 12.7/22 KV Cu/SC/XLPE/SC/CUT/PVC/SWA/PVC

17

Three Core Cables 12.7/22 KV AI/SC/XLPE/SC/CUT/PVC/SWA/PVC

18

Single Core cables 19/33 KV Cu/SC/XLPE/SC/CUT/PVC/AWA/PVC

19

Three Core Cables 19/33 KV Cu/SC/XLPE/SC/CUT/PVC/SWA/PVC

20

Three Core Cables 19/33 KV AI/ SC/XLPE/SC/CUT/PVC/SWA/PVC

21

AUXILIARY CABLES
Pilot Cables 16 and 34 Core Cables

22

TECHNICAL INFORMATION
CURRENT RATING
Installation Conditions

23-24

3.8/6.6 to 19/33 KV XLPE Insulated Cables

25

Rating Factors for Air, Ground and Duct

26

Group Rating Factors


Rating Factors for Thermal Resistivity of Soil

27
28-30

AC RESISTANCE, RECATANCE AND CAPACITANCE VALUES


3.8/6.6 KV and 6.35/11 KV Cables

31

8.7/15 KV and 12.7/22 KV Cables

32

19/33 KV Cables

33

SHORT CIRCUIT CURVES


Copper Conductor XLPE Insulated Cables

34

Aluminum Conductor XLPE Insulated Cables

35

DRUMS
Drum Sizes and Dimensions

36

Gulf Cable & Electrical Ind. Co.


PRODUCT RANGE

We at Gulf Cable always aim for the best. While most of the Cable Manufacturers in Gulf and Middle East region settled for
ISO 9002, we stand out with ISO 9001 which recognizes our ability for Design & Development as well.
As a philosophy, our commitment to customers does not end with a sale. We also offer a host of related services before and
after the sale. These include,
Application engineering service for selection of appropriate product best suiting the end use.
An extensive range of cables, single core wires, flexible cords bare & insulated conductors manufactured to stringent Quality
Standards going beyond international specifications.
Design and Development of products tailored to meet specific requirements of the application.
To help the customers understand the product intricacies and its performance levels.
NOTE 1: THE TABULATIONS ON SUBSEQUENT PAGES FURNISH OVERALL DIMENSIONS, NET & GROSS WEIGHTS AND DRUM
DIMENSIONS. PLEASE NOTE THAT THESE ARE "APPROXIMATE" VALUES. THEY HAVE BEEN FURNISHED FOR GENERAL GUIDELINES
AND INTENDED TO BE USED FOR THUMB RULE ESTIMATIONS/FREIGHT CALCULATIONS.
NOTE 2: VOLTAGE RATING:
TWO DISTINCT SYSTEMS OF VOLTAGE DESIGNATION ARE GENERALLY IN USE. EQUIVALENCE BETWEEN THESE TWO SYSTEMS
BASED ON INSULATION THICKNESS AND MAXIMUM VALUE OF HIGHEST SYSTEM VOLTAGE IS AS TABULATED BELOW:
IEC DESIGNATION
Uo/U (Um)

BS DESIGNATION
Uo/U (Um)

3.6 / 6 (7.2)

KV

3.8 / 6.6 (7.2)

KV

6 / 10 (12)

KV

6.35 / 11 (12)

KV

8.7 / 15 (17.5)

KV

8.7 / 15 (17.5)

KV

12 / 20 (24)

KV

12.7 / 22 (24)

KV

18 / 30 (36)

KV

19 / 33 (36)

KV

Where,
Uo is rated power frequency voltage between conductor and earth or metallic screen, for which the cable is designed.
U is the rated power frequency voltage between conductors, for which the cable is designed.
Um is the maximum value of "highest system voltage" for which the equipment may be used.
FROM ABOVE TABULATION, EQUIVALENT IEC / BS DESIGNATION CAN BE DETERMINED FOR ANY SYSTEM AS APPROPRIATE.

Gulf Cable & Electrical Ind. Co.


PRODUCT RANGE

II

NOTE 3: THE FOLLOWING LIST TABULATES ONLY THE "STANDARD" PRODUCTS. FOR ANY PRODUCT NOT LISTED BELOW, PLEASE
DO NOT HESITATE TO CONTACT OUR SALES & MARKETTING DIVISION. WE SHALL BE TOO PLEASED TO MEET YOUR SPECIFIC
REQUIREMENTS.

PRODUCT

STANDARD

Medium Voltage Power Cables up to 30 KV


XLPE insulated, single core or multicore armoured or unarmoured cables

IEC 60502 / BS 6622

Auxiliary Cables
16 core or 34 core pilot cables to be used along with underground
powerlines 11KV, 132 KV and beyond

MEW / ESI Standards

Gulf Cable & Electrical Ind. Co.


3.8 / 6.6 KV - SINGLE CORE
(HIGHEST SYSTEM VOLTAGE = 7.2 KV)
COPPER CONDUCTOR XLPE INSULATED
ALUMINIUM WIRE ARMOURED
PVC SHEATHED CABLES
(Cu/SC/XLPE/SC/AWA/PVC)

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Bedding
(Semiconducting)
Tape

Dia of
Armour
Wire

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/Km

mm

mm

mm

mm

mm

Kg/Km

Metre 10%

35
50
70

0.524
0.387
0.268

2.5
2.5
2.5

0.4
0.4
0.4

1.6
1.6
1.6

1.8
1.8
1.8

23.9
25.0
26.6

860
1010
1250

500
500
500

D-11
D-12
D-12

530
615
735

95
120
150

0.193
0.153
0.124

2.5
2.5
2.5

0.4
0.4
0.4

1.6
1.6
1.6

1.8
1.9
1.9

28.5
30.2
31.6

1560
1840
2160

500
500
500

D-12
D-14
D-14

890
1070
1230

185
240
300

0.0991
0.0754
0.0601

2.5
2.6
2.8

0.4
0.4
0.4

1.6
2.0
2.0

2.0
2.1
2.2

33.4
37.1
39.7

2530
3240
3900

500
500
500

D-16
D-18
D-18

1480
1860
2190

400
500
630

0.0470
0.0366
0.0283

3.0
3.2
3.2

0.4
0.4
0.4

2.0
2.5
2.5

2.3
2.4
2.5

43.2
47.8
51.8

4870
6110
7520

500
500
500

D-18
D-19
D-19

2680
3380
4080

All conductors circular compacted.


Equivalent voltage designation as per IEC: 60502 - 2 - 1997 : 3.6 / 6 KV
Cables conform to IEC 60502 - 2 - 1997

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


3.8 / 6.6 KV - THREE CORE
(HIGHEST SYSTEM VOLTAGE - 7.2 KV)
COPPER CONDUCTOR XLPE INSULATED
STEEL WIRE ARMOURED
PVC SHEATHED CABLES
(Cu/SC/XLPE/SC/SWA/PVC)

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Bedding
(Semiconducting)
Tape

Dia of
Armour
Wire

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/Km

mm

mm

mm

mm

mm

Kg/Km

Metre 10%

35
50
70

0.524
0.387
0.268

2.5
2.5
2.5

0.4
0.4
0.6

2.0
2.5
2.5

2.3
2.4
2.5

43.9
47.5
51.1

3310
4230
5100

500
500
500

D-18
D-19
D-19

1900
2440
2870

95
120
150

0.193
0.153
0.124

2.5
2.5
2.5

0.6
0.6
0.6

2.5
2.5
2.5

2.7
2.8
2.9

56.2
59.7
62.9

6260
7240
8310

500
500
250

D-21
D-22
D-18

3550
4090
2320

185
240
300

0.0991
0.0754
0.0601

2.5
2.6
2.8

0.6
0.6
0.6

2.5
2.5
3.15

3.0
3.2
3.4

66.6
72.8
79.7

9570
11650
14740

250
250
250

D-18
D-21
D-23

2630
3330
4190

400

0.0470

3.0

0.6

3.15

3.7

87.4

18020

250

D-23

5010

All conductors circular compacted.


Equivalent voltage designation as per IEC 60502 - 2 - 1997 : 3.6 /6 KV
Cables conform to IEC 60502 - 2 -1997.

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


6.35/11 KV - SINGLE CORE
(HIGHEST SYSTEM VOLTAGE -12 KV)
COPPER CONDUCTOR XLPE INSULATED
ALUMINIUM WIRE ARMOURED
PVC SHEATHED CABLES
(Cu/SC/XLPE/SC/AWA/PVC)

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Bedding
(Semiconducting)
Tape

Dia of
Armour
Wire

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/km

mm

mm

mm

mm

mm

Kg/Km

Metre 10%

35
50
70

0.524
0.387
0.268

3.4
3.4
3.4

0.4
0.4
0.4

1.6
1.6
1.6

1.8
1.8
1.8

26.0
27.0
28.0

950
1110
1340

500
500
500

D-12
D-12
D-12

585
660
780

95
120
150

0.193
0.153
0.124

3.4
3.4
3.4

0.4
0.4
0.4

1.6
1.6
1.6

1.9
1.9
2.0

30.5
32.0
33.6

1670
1940
2280

500
500
500

D-14
D-14
D-16

985
1120
1350

185
240
300

0.0991
0.0754
0.0601

3.4
3.4
3.4

0.4
0.4
0.4

2.0
2.0
2.0

2.0
2.1
2.2

36.0
39.0
40.9

2730
3340
3990

500
500
500

D-18
D-18
D-18

1600
1910
2240

400
500
630

0.0470
0.0366
0.0283

3.4
3.4
3.4

0.4
0.4
0.4

2.0
2.5
2.5

2.3
2.4
2.5

44.0
48.2
52.2

4930
6150
7560

500
500
500

D-18
D-19
D-19

2710
3390
4100

All conductors circular compacted.


Equivalent voltage designation as per IEC: 60502 - 2 - 1997 : 6/10 KV
Cables conform to IEC 60502 - 2 - 1997

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


6.35/11 KV - SINGLE CORE
(HIGHEST SYSTEM VOLTAGE -12 KV)
COPPER CONDUCTOR XLPE INSULATED
COPPER TAPE SCREENED
ALUMINIUM WIRE ARMOURED
PVC SHEATHED CABLES
(Cu/SC/XLPE/SC/CuT/PVC/AWA/PVC)

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Copper
Tape

Thickness
of Extruded
Bedding

Dia of
Armour
Wire

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/Km

mm

mm

mm

mm

mm

mm

Kg/Km

Metre 10%

35
50
70

0.524
0.387
0.268

3.4
3.4
3.4

0.075
0.075
0.075

1.2
1.2
1.2

1.6
1.6
1.6

1.8
1.8
1.9

27.3
28.4
30.2

1130
1290
1560

500
500
500

D-12
D-12
D-14

675
755
930

95
120
150

0.193
0.153
0.124

3.4
3.4
3.4

0.075
0.075
0.075

1.2
1.2
1.2

1.6
1.6
2.0

1.9
2.0
2.1

32.1
33.8
36.2

1880
2190
2620

500
500
500

D-16
D-16
D-18

1150
1330
1550

185
240
300

0.0991
0.0754
0.0601

3.4
3.4
3.4

0.075
0.075
0.075

1.2
1.2
1.2

2.0
2.0
2.0

2.1
2.2
2.2

37.8
40.5
42.5

3000
3640
4290

500
500
500

D-18
D-18
D-18

1740
2060
2390

400
500
630

0.0470
0.0366
0.0283

3.4
3.4
3.4

0.075
0.075
0.075

1.2
1.3
1.4

2.0
2.5
2.5

2.4
2.5
2.6

45.8
50.2
54.4

5270
6550
8020

500
500
500

D-19
D-19
D-21

2960
3600
4430

All conductors circular compacted.


Equivalent voltage designation as per IEC 60502 - 2 - 1997 : 6/10 KV
Cables conform to IEC 60502 - 2 - 1997.

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


6.35/11 KV - THREE CORE
(HIGHEST SYSTEM VOLTAGE - 12 KV)
COPPER CONDUCTOR XLPE INSULATED
STEEL WIRE ARMOURED
PVC SHEATHED CABLES
(Cu /SC/XLPE/SC/SWA/PVC)

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Bedding
(Semiconducting)
Tape

Dia of
Armour
Wire

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/Km

mm

mm

mm

mm

mm

Kg/Km

Metre 10%

35
50
70

0.524
0.387
0.268

3.4
3.4
3.4

0.4
0.4
0.6

2.5
2.5
2.5

2.4
2.5
2.7

49.0
51.6
56.0

4060
4640
5630

500
500
500

D-19
D-19
D-21

2350
2640
3240

95
120
150

0.193
0.153
0.124

3.4
3.4
3.4

0.6
0.6
0.6

2.5
2.5
2.5

2.8
2.9
3.0

60.3
63.8
67.0

6720
7720
8800

500
250
250

D-22
D-18
D-18

3830
2170
2440

185
240
300

0.0991
0.0754
0.0601

3.4
3.4
3.4

0.6
0.6
0.6

2.5
3.15
3.15

3.1
3.3
3.5

70.7
77.9
82.5

10080
12960
15150

250
250
250

D-21
D-21
D-23

2940
3660
4290

400

0.0470

3.4

0.6

3.15

3.7

89.1

18270

250

D-23

5070

All conductors circular compacted.


Equivalent voltage designation as per IEC 60502 - 2 - 1997 : 6/10 KV
Cables conform to IEC :60502 - 2 - 1997

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


6.35/11 KV - THREE CORE
(HIGHEST SYSTEM VOLTAGE - 12 KV)
COPPER CONDUCTOR XLPE INSULATED
COPPER TAPE SCREENED
STEEL WIRE ARMOURED
PVC SHEATHED CABLES
(Cu/SC/XLPE/SC/CuT/PVC/SWA/PVC)

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Copper
Tape

Thickness
of Extruded
Bedding

Dia of
Armour
Wire

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/Km

mm

mm

mm

mm

mm

mm

Kg/Km

Metre 10%

35
50
70

0.524
0.387
0.268

3.4
3.4
3.4

0.075
0.075
0.075

1.3
1.4
1.4

2.5
2.5
2.5

2.5
2.6
2.7

52.0
54.8
58.5

4700
5300
6240

500
500
500

D-19
D-21
D-22

2670
3070
3590

95
120
150

0.193
0.153
0.124

3.4
3.4
3.4

0.075
0.075
0.075

1.5
1.6
1.6

2.5
2.5
2.5

2.9
3.0
3.1

63.2
66.8
70.0

7460
8530
9650

500
500
500

D-23
D-23
D-23

4230
4770
5330

185
240
300

0.0991
0.0754
0.0601

3.4
3.4
3.4

0.075
0.075
0.075

1.7
1.8
1.9

2.5
3.15
3.15

3.2
3.4
3.6

73.9
81.2
86.1

11040
14060
16340

250
250
250

D-21
D-23
D-23

3180
4020
4590

400

0.0470

3.4

0.075

2.0

3.15

3.8

93.0

19610

250

D-23

5400

All conductors circular compacted.


Equivalent voltage designation as per IEC 60502 - 2 - 1997 : 6/10KV
Cables conform to IEC 60502 - 2 -1997

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


6.35/11 KV - THREE CORE
(HIGHEST SYSTEM VOLTAGE - 12KV)
ALUMINIUM CONDUCTOR XLPE INSULATED
STEEL WIRE ARMOURED
PVC SHEATHED CABLES
(AI/SC/XLPE/SC/SWA/PVC)

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Bedding
(Semiconducting)
Tape

Dia of
Armour
Wire

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/Km

mm

mm

mm

mm

mm

Kg/Km

Metre 10%

35
50
70

0.868
0.641
0.443

3.4
3.4
3.4

0.4
0.4
0.6

2.5
2.5
2.5

2.4
2.5
2.7

49.0
51.6
56.5

3440
3790
4430

500
500
500

D-19
D-19
D-21

2040
2220
2640

95
120
150

0.320
0.253
0.206

3.4
3.4
3.4

0.6
0.6
0.6

2.5
2.5
2.5

2.8
2.9
3.0

60.6
63.8
67.0

5050
5550
6070

500
500
500

D-22
D-23
D-23

3000
3280
3540

185
240
300

0.164
0.125
0.100

3.4
3.4
3.4

0.6
0.6
0.6

2.5
3.15
3.15

3.1
3.3
3.5

70.9
78.0
82.5

6740
8590
9640

250
250
250

D-21
D-21
D-23

2110
2570
2910

400

0.0778

3.4

0.6

3.15

3.7

89.6

11160

250

D-23

3290

All conductors circular compacted.


Equivalent voltage designation as per IEC 60502 - 2 - 1997 : 6/10 KV
Cables conform to IEC 60502 - 2 - 1997.

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


6.35/11 KV - THREE CORE
(HIGHEST SYSTEM VOLTAGE - 12 KV)
ALUMINIUM CONDUCTOR XLPE INSULATED
COPPER TAPE SCREENED
STEEL WIRE ARMOURED
PVC SHEATHED CABLES
(AI/SC/XLPE/SC/CuT/PVC/SWA/PVC)

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Copper
Tape

Thickness
of Extruded
Bedding

Dia of
Armour
Wire

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/Km

mm

mm

mm

mm

mm

mm

Kg/Km

Metre 10%

35
50
70

0.868
0.641
0.443

3.4
3.4
3.4

0.075
0.075
0.075

1.3
1.4
1.4

2.5
2.5
2.5

2.5
2.6
2.7

52.0
54.8
58.9

4090
4450
5080

500
500
500

D-19
D-21
D-22

2370
2650
3010

95
120
150

0.320
0.253
0.206

3.4
3.4
3.4

0.075
0.075
0.075

1.5
1.6
1.6

2.5
2.5
2.5

2.9
3.0
3.1

63.4
66.8
70.0

5750
6350
6920

500
500
500

D-23
D-23
D-23

3380
3680
3960

185
240
300

0.164
0.125
0.100

3.4
3.4
3.4

0.075
0.075
0.075

1.7
1.8
1.9

2.5
3.15
3.15

3.2
3.4
3.6

74.1
81.4
86.1

7700
9690
10830

500
500
500

D-23
D-24
D-25-S

4350
5450
6170

400

0.0778

3.4

0.075

2.0

3.15

3.8

93.4

12500

250

D-23

3630

All conductors circular compacted.


Equivalent voltage designation as per IEC 60502 - 2 - 1997 : 6/10 KV
Cables conform to IEC 60502 - 2 - 1997.

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


8.7/15KV - SINGLE CORE
(HIGHEST SYSTEM VOLTAGE - 17.5 KV)
COPPER CONDUCTOR XLPE INSULATED
ALUMINIUM WIRE ARMOURED
PVC SHEATHED CABLES
(Cu/SC/XLPE/SC/AWA/PVC)

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Bedding
(Semiconducting)
Tape

Dia of
Armour
Wire

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/Km

mm

mm

mm

mm

mm

Kg/Km

Metre 10%

35
50
70

0.524
0.387
0.268

4.5
4.5
4.5

0.4
0.4
0.4

1.6
1.6
1.6

1.8
1.8
1.9

27.9
29.0
30.8

1050
1210
1470

500
500
500

D-12
D-12
D-14

635
715
885

95
120
150

0.193
0.153
0.124

4.5
4.5
4.5

0.4
0.4
0.4

1.6
2.0
2.0

1.9
2.0
2.1

32.7
35.2
36.8

1780
2170
2510

500
500
500

D-16
D-18
D-18

1100
1330
1500

185
240
300

0.0991
0.0754
0.0601

4.5
4.5
4.5

0.4
0.4
0.4

2.0
2.0
2.0

2.1
2.2
2.3

38.4
41.1
43.3

2890
3510
4170

500
500
500

D-18
D-18
D-18

1680
2000
2330

400
500
630

0.0470
0.0366
0.0283

4.5
4.5
4.5

0.4
0.4
0.4

2.5
2.5
2.5

2.4
2.5
2.6

47.4
50.6
54.6

5240
6350
7780

500
500
500

D-19
D-19
D-21

2950
3500
4310

All conductors circular compacted


Cables conform to IEC 60502 - 2 - 1997

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


8.7/15 KV - SINGLE CORE
(HIGHEST SYSTEM VOLTAGE - 17.5 KV)
COPPER CONDUCTOR XLPE INSULATED
COPPER TAPE SCREENED
PVC SHEATHED CABLES
(Cu/SC/XLPE/SC/CuT/PVC)

10

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Copper
Tape

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/Km

mm

mm

mm

mm

Kg/Km

Metre 10%

35
50
70

0.524
0.387
0.268

4.5
4.5
4.5

0.075
0.075
0.075

1.8
1.8
1.8

23.7
24.8
26.4

835
980
1220

500
500
500

D-12
D-12
D-12

520
600
720

95
120
150

0.193
0.153
0.124

4.5
4.5
4.5

0.075
0.075
0.075

1.8
1.9
1.9

28.3
30.0
31.4

1520
1800
2110

500
500
500

D-12
D-12
D-14

870
1010
1210

185
240
300

0.0991
0.0754
0.0601

4.5
4.5
4.5

0.075
0.075
0.075

2.0
2.0
2.1

33.2
35.7
37.9

2480
3070
3700

500
500
500

D-16
D-18
D-18

1450
1780
2090

400
500
630

0.0470
0.0366
0.0283

4.5
4.5
4.5

0.075
0.075
0.075

2.2
2.3
2.4

41.0
44.2
48.2

4620
5660
7040

500
500
500

D-18
D-18
D-19

2550
3070
3840

All conductors circular compacted.


Cables conform to IEC 60502 - 2- 1997.

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


8.7/15 KV - SINGLE CORE
(HIGHEST SYSTEM VOLTAGE - 17.5 KV)
COPPER CONDUCTOR XLPE INSULATED
COPPER TAPE SCREENED
ALUMINIUM WIRE ARMOURED
PVC SHEATHED CABLES
(Cu/SC/XLPE/SC/CuT/PVC/AWA/PVC)

11

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Copper
Tape

Thickness
of Extruded
Bedding

Dia of
Armour
Wire

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/Km

mm

mm

mm

mm

mm

mm

Kg/Km

Metre 10%

35
50
70

0.524
0.387
0.268

4.5
4.5
4.5

0.075
0.075
0.075

1.2
1.2
1.2

1.6
1.6
1.6

1.9
1.9
1.9

29.7
30.8
32.4

1270
1430
1700

500
500
500

D-12
D-14
D-16

745
865
1060

95
120
150

0.193
0.153
0.124

4.5
4.5
4.5

0.075
0.075
0.075

1.2
1.2
1.2

2.0
2.0
2.0

2.0
2.1
2.1

35.3
37.0
38.4

2130
2440
2780

500
500
500

D-18
D-18
D-18

1310
1460
1630

185
240
300

0.0991
0.0754
0.0601

4.5
4.5
4.5

0.075
0.075
0.075

1.2
1.2
1.2

2.0
2.0
2.0

2.2
2.3
2.3

40.2
42.9
44.9

3180
3840
4490

500
500
500

D-18
D-18
D-18

1830
2160
2490

400
500
630

0.0470
0.0366
0.0283

4.5
4.5
4.5

0.075
0.075
0.075

1.3
1.3
1.4

2.5
2.5
2.5

2.5
2.6
2.7

49.4
52.6
56.8

5660
6770
8280

500
500
500

D-19
D-19
D-21

3150
3710
4560

All the conductors circular compacted.


Cables conform to IEC 60502 - 2 - 1997

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


8.7/15 KV - THREE CORE
(HIGHEST SYSTEM VOLTAGE - 17.5 KV)
COPPER CONDUCTOR XLPE INSULATED
COPPER TAPE SCREENED
PVC SHEATHED CABLES
(Cu/SC/XLPE/SC/CuT/PVC)

12

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Copper
Tape

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/Km

mm

mm

mm

mm

Kg/Km

Metre 10%

35
50
70

0.524
0.387
0.268

4.5
4.5
4.5

0.075
0.075
0.075

2.5
2.6
2.7

49.4
52.0
55.6

2760
3250
4030

500
500
500

D-19
D-19
D-21

1700
1950
2440

95
120
150

0.193
0.153
0.124

4.5
4.5
4.5

0.075
0.075
0.075

2.8
2.9
3.0

59.9
63.4
66.6

5000
5880
6880

500
500
500

D-22
D-23
D-23

2970
3440
3940

185
240
300

0.0991
0.0754
0.0601

4.5
4.5
4.5

0.075
0.075
0.075

3.1
3.3
3.4

70.2
76.0
80.6

8030
9930
11890

500
500
500

D-23
D-23
D-23

4520
5470
6450

400

0.0470

4.5

0.075

3.7

87.4

14800

250

D-23

4200

All conductors circular compacted.


Cables conform to IEC 60502 - 2 - 1997.

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


8.7/15 KV - THREE CORE
(HIGHEST SYSTEM VOLTAGE - 17.5 KV)
COPPER CONDUCTOR XLPE INSULATED
COPPER TAPE SCREENED
STEEL WIRE ARMOURED
PVC SHEATHED CABLES
(Cu/SC/XLPE/SC/CuT/PVC/SWA/PVC)

13

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Copper
Tape

Thickness
of Extruded
Bedding

Dia of
Armour
Wire

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/km

mm

mm

mm

mm

mm

mm

Kg/km

Metre 10%

35
50
70

0.524
0.387
0.268

4.5
4.5
4.5

0.075
0.075
0.075

1.4
1.5
1.5

2.5
2.5
2.5

2.7
2.8
2.9

57.4
60.2
63.8

5320
5980
6940

500
500
500

D-22
D-22
D-23

3130
3460
3870

95
120
150

0.193
0.153
0.124

4.5
4.5
4.5

0.075
0.075
0.075

1.6
1.7
1.7

2.5
2.5
2.5

3.0
3.1
3.2

68.3
72.0
75.2

8170
9270
10410

500
500
500

D-23
D-23
D-23

4590
5140
5710

185
240
300

0.0991
0.0754
0.0601

4.5
4.5
4.5

0.075
0.075
0.075

1.8
1.9
2.0

3.15
3.15
3.15

3.4
3.6
3.7

80.5
86.5
91.3

12630
14930
17230

500
500
500

D-23
D-25-S
D-25-S

6820
8220
9370

400

0.0470

4.5

0.075

2.1

3.15

4.0

98.3

20580

400

D-25-S

8980

All conductors circular compacted.


Cables conform to IEC 60502 - 2 - 1997

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


8.7/15 KV - THREE CORE
(HIGHEST SYSTEM VOLTAGE - 17.5 KV)
ALUMINIUM CONDUCTOR XLPE INSULATED
COPPER TAPE SCREENED
STEEL WIRE ARMOURED
PVC SHEATHED CABLES
(AI/SC/XLPE/SC/CuT/PVC/SWA/PVC)

14

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Copper
Tape

Thickness
of Extruded
Bedding

Dia of
Armour
Wire

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/km

mm

mm

mm

mm

mm

mm

Kg/km

Metre 10%

35
50
70

0.868
0.641
0.443

4.5
4.5
4.5

0.075
0.075
0.075

1.4
1.5
1.5

2.5
2.5
2.5

2.7
2.8
2.9

57.4
60.2
64.2

4710
5130
5740

500
500
500

D-19
D-22
D-23

2680
3040
3370

95
120
150

0.320
0.253
0.206

4.5
4.5
4.5

0.075
0.075
0.075

1.6
1.7
1.7

2.5
2.5
2.5

3.0
3.1
3.2

68.5
72.0
75.2

6460
7100
7680

500
500
500

D-23
D-23
D-23

3730
4050
4340

185
240
300

0.164
0.125
0.100

4.5
4.5
4.5

0.075
0.075
0.075

1.8
1.9
2.0

3.15
3.15
3.15

3.4
3.6
3.7

80.8
86.8
91.3

9370
10580
11720

500
500
500

D-23
D-25-S
D-25-S

5190
6040
2930

400

0.0778

4.5

0.075

2.1

3.15

4.0

98.8

13490

400

D-25-S

6150

All conductors circular compacted.


Cables conform to IEC 60502 - 2 - 1997.

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


12.7/22 KV - SINGLE CORE
(HIGHEST SYSTEM VOLTAGE - 24 KV)
COPPER CONDUCTOR XLPE INSULATED
COPPER TAPE SCREENED
PVC SHEATHED CABLES
(Cu/SC/XLPE/SC/CuT/PVC)

15

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Copper
Tape

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/km

mm

mm

mm

mm

Kg/km

Metre 10%

35
50
70

0.524
0.387
0.268

5.5
5.5
5.5

0.075
0.075
0.075

1.8
1.8
1.8

25.7
26.8
28.4

920
1070
1310

500
500
500

D-12
D-12
D-12

570
645
765

95
120
150

0.193
0.153
0.124

5.5
5.5
5.5

0.075
0.075
0.075

1.9
1.9
2.0

30.5
32.0
33.6

1630
1900
2240

500
500
500

D-14
D-14
D-16

965
1100
1330

185
240
300

0.0991
0.0754
0.0601

5.5
5.5
5.5

0.075
0.075
0.075

2.0
2.1
2.2

35.2
37.9
40.1

2600
3200
3850

500
500
500

D-18
D-18
D-18

1540
1840
2170

400
500

0.0470
0.0366

5.5
5.5

0.075
0.075

2.3
2.4

43.2
46.4

4770
5830

500
500

D-18
D-19

2630
3240

630

0.0283

5.5

0.075

2.5

50.4

7220

500

D-19

3930

All conductors circular compacted.


Equivalent voltage designation as per IEC 60502 - 2 - 1997 : 12/20 KV
Cables conform to IEC 60502 - 2 - 1997.

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


12.7/22 KV - THREE CORE
(HIGHEST SYSTEM VOLTAGE - 24 KV)
COPPER CONDUCTOR XLPE INSULATED
COPPER TAPE SCREENED
PVC SHEATHED CABLES
(Cu/SC/XLPE/SC/CuT/PVC)

16

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Copper
Tape

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/km

mm

mm

mm

mm

Kg/km

Metre 10%

35
50
70

0.524
0.387
0.268

5.5
5.5
5.5

0.075
0.075
0.075

2.6
2.7
2.8

53.9
56.5
60.1

3100
3610
4410

500
500
500

D-19
D-21
D-22

1870
2130
2630

95
120
150

0.193
0.153
0.124

5.5
5.5
5.5

0.075
0.075
0.075

2.9
3.0
3.1

64.4
67.9
71.1

5400
6300
7320

500
500
500

D-23
D-23
D-23

3170
3650
4160

185
240
300

0.0991
0.0754
0.0601

5.5
5.5
5.5

0.075
0.075
0.075

3.3
3.4
3.6

75.0
80.6
85.3

8540
10440
12450

500
250
250

D-23
D-23
D-23

4770
3110
3610

400

0.0470

5.5

0.075

3.8

91.9

15370

200

D-23

3570

All conductors circular compacted.


Equivalent voltage designation as per IEC 60502-2-1997 : 12/20 KV
Cables conform to IEC: 60502 - 2 - 1997

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


12.7/22 KV - THREE CORE
(HIGHEST SYSTEM VOLTAGE -24 KV)
COPPER CONDUCTOR XLPE INSULATED
COPPER TAPE SCREENED
STEEL WIRE ARMOURED
PVC SHEATHED CABLES
(Cu/SC/XLPE/SC/CuT/PVC/SWA/PVC)

17

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Copper
Tape

Thickness
of Extruded
Bedding

Dia of
Armour
Wire

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/km

mm

mm

mm

mm

mm

mm

Kg/km

Metre 10%

35
50
70

0.524
0.387
0.268

5.5
5.5
5.5

0.075
0.075
0.075

1.5
1.6
1.6

2.5
2.5
2.5

2.8
2.9
3.1

62.1
64.9
68.7

5920
6600
7610

500
500
500

D-23
D-23
D-23

3460
3800
4310

95
120
150

0.193
0.153
0.124

5.5
5.5
5.5

0.075
0.075
0.075

1.7
1.7
1.8

2.5
3.15
3.15

3.2
3.3
3.4

73.2
78.0
81.4

8870
10730
12000

500
250
250

D-23
D-21
D-23

4940
3100
3500

185
240
300

0.0991
0.0754
0.0601

5.5
5.5
5.5

0.075
0.075
0.075

1.9
2.0
2.0

3.15
3.15
3.15

3.6
3.7
3.9

85.5
91.3
96.0

13460
15780
18110

200
200
200

D-22
D-23
D-24

3160
3660
4220

400

0.0470

5.5

0.075

2.2

3.15

4.1

103.0

21500

200

D-24

4900

All conductors circular compacted .


Equivalent voltage designation as per IEC 60502-2-1997 : 12/20 KV
Cables conform to IEC: 60502 - 2 - 1997

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


12.7/22 KV - THREE CORE
(HIGHEST SYSTEM VOLTAGE - 24 KV)
ALUMINIUM CONDUCTOR XLPE INSULATED
COPPER TAPE SCREENED
STEEL WIRE ARMOURED
PVC SHEATHED CABLES
(AI/SC/XLPE/SC/CuT/PVC/SWA/PVC)

18

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Copper
Tape

Thickness
of Extruded
Bedding

Dia of
Armour
Wire

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/km

mm

mm

mm

mm

mm

mm

Kg/km

Metre 10%

35
50
70

0.868
0.641
0.443

5.5
5.5
5.5

0.075
0.075
0.075

1.5
1.6
1.6

2.5
2.5
2.5

2.8
2.9
3.1

62.1
64.9
69.2

5300
5740
6400

500
500
500

D-23
D-23
D-23

3150
3370
3710

95
120
150

0.320
0.253
0.206

5.5
5.5
5.5

0.075
0.075
0.075

1.7
1.7
1.8

2.5
3.15
3.15

3.2
3.3
3.4

73.5
78.0
81.4

7170
8550
9260

500
250
250

D-23
D-21
D-23

4090
2560
2820

185
240
300

0.164
0.125
0.100

5.5
5.5
5.5

0.075
0.075
0.075

1.9
2.0
2.0

3.15
3.15
3.15

3.6
3.7
3.9

85.7
91.5
96.0

10130
11420
12590

200
200
200

D-22
D-23
D-23

2500
2780
3020

400

0.0778

5.5

0.075

2.2

3.15

4.1

103.5

14410

200

D-23

3380

All conductors circular compacted.


Equivalent voltage designation as per IEC 60502-2-1997 : 12/20 KV
Cables conform to IEC 60502 - 2 - 1997.

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


19/33 KV - SINGLE CORE
(HIGHEST SYSTEM VOLTAGE - 36 KV)
COPPER CONDUCTOR XLPE INSULATED
COPPER TAPE SCREENED
ALUMINIUM WIRE ARMOURED
PVC SHEATHED CABLES
(Cu/SC/XLPE/SC /CuT/PVC/AWA/PVC)

19

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Copper
Tape

Thickness
of Extruded
Bedding

Dia of
Armour
Wire

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/km

mm

mm

mm

mm

mm

mm

Kg/km

Metre 10%

50
70
95

0.387
0.268
0.193

8.0
8.0
8.0

0.075
0.075
0.075

1.2
1.2
1.2

2.0
2.0
2.0

2.2
2.2
2.3

39.4
41.0
43.1

2050
2330
2710

500
500
500

D-18
D-18
D-18

1270
1410
1600

120
150
185

0.153
0.124
0.0991

8.0
8.0
8.0

0.075
0.075
0.075

1.2
1.3
1.3

2.0
2.5
2.5

2.3
2.4
2.5

44.6
47.4
49.2

3020
3570
3990

500
500
500

D-18
D-19
D-19

1750
2110
2320

240
300
400

0.0754
0.0601
0.0470

8.0
8.0
8.0

0.075
0.075
0.075

1.3
1.4
1.4

2.5
2.5
2.5

2.5
2.6
2.7

51.7
54.1
57.2

4670
5410
6430

500
500
500

D-19
D-21
D-22

2660
3130
3690

500
630

0.0366
0.0283

8.0
8.0

0.075
0.075

1.5
1.6

2.5
2.5

2.8
2.9

60.6
64.8

7620
8935

500
500

D-22
D-21 M

4280
4890

All conductors circular compacted.


Equivalent voltage designation as per IEC 60502 - 2 - 1997. 18/30 KV
Cables conform to IEC 60502 - 2 - 1997.

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


19/33 KV - THREE CORE
(HIGHEST SYSTEM VOLTAGE - 36 KV)
COPPER CONDUCTOR XLPE INSULATED
COPPER TAPE SCREENED
STEEL WIRE ARMOURED
PVC SHEATHED CABLES
(Cu/SC/XLPE/SC/CuT/PVC/SWA/PVC)

20

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Copper
Tape

Thickness
of Extruded
Bedding

Dia of
Armour
Wire

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/km

mm

mm

mm

mm

mm

mm

Kg/km

Metre 10%

50
70
95

0.387
0.268
0.193

8.0
8.0
8.0

0.075
0.075
0.075

1.8
1.8
1.9

3.15
3.15
3.15

3.4
3.5
3.6

78.8
82.5
87.0

9230
10310
11640

500
500
500

D-23
D-24
D-25-S

5120
5760
6570

120
150
185

0.153
0.124
0.0991

8.0
8.0
8.0

0.075
0.075
0.075

2.0
2.0
2.1

3.15
3.15
3.15

3.7
3.8
4.0

90.6
93.8
97.9

12850
14150
15700

250
250
250

D-23
D-23
D-23

3710
4040
4430

240
300

0.0754
0.0601

8.0
8.0

0.075
0.075

2.2
2.3

3.15
3.15

4.1
4.3

104.0
109.0

18120
20570

250
200

D-25
D-25

5280
4860

All conductors circular compacted.


Equivalent voltage designation as per IEC 60502 - 2 - 1997. 18/30 KV
Cables conform to IEC 60502 - 2 - 1997.

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


19/33 KV - THREE CORE
(HIGHEST SYSTEM VOLTAGE - 36 KV)
ALUMINIUM CONDUCTOR, XLPE INSULATED
COPPER TAPE SCREENED
STEEL WIRE ARMOURED
PVC SHEATHED CABLES
(AL/SC/XLPE/SC/CuT/PVC/SWA/PVC)

21

Nominal
Area of
Conductor

Maximum
Conductor
Resistance
at 20C

Thickness
of XLPE
Insulation

Thickness
of Copper
Tape

Thickness
of Extruded
Bedding

Dia of
Armour
Wire

Thickness
of Outer
Sheath

Approx.
Overall
Diameter

Approx.
Cable
Weight

Standard
Packing
Length

Sqmm

Ohm/km

mm

mm

mm

mm

mm

mm

Kg/km

Metre 10%

50
70
95

0.641
0.443
0.320

8.0
8.0
8.0

0.075
0.075
0.075

1.8
1.8
1.9

3.15
3.15
3.15

3.4
3.5
3.6

78.8
82.9
87.2

8380
9120
10000

500
500
500

D-23
D-24
D-25-S

4690
5160
5750

120
150
185

0.253
0.206
0.164

8.0
8.0
8.0

0.075
0.075
0.075

2.0
2.0
2.1

3.15
3.15
3.15

3.7
3.8
4.0

90.6
93.8
98.1

10680
11410
12370

250
250
250

D-23
D-23
D-23

3170
3350
3590

240
300

0.125
0.100

8.0
8.0

0.075
0.075

2.2
2.3

3.15
3.15

4.1
4.3

104.0
109.0

13760
15060

250
200

D-25
D-25

4190
3760

All conductors circular compacted.


Equivalent voltage designation as per IEC 60502 - 2 - 1997. 18/30 KV
Cables conform to IEC 60502 - 2 - 1997.

Drum
Size

Approx.
Gross
Weight

Kg

Gulf Cable & Electrical Ind. Co.


PILOT CABLE
COPPER CONDUCTOR PE INSULATED
STEEL WIRE ARMOURED PVC SHEATHED CABLES

22

Total
To
Thickness Thickness Thickness Thickness Diameter Thickness Approx. Approx. Standard
CONDUCTOR
Number Withstand
of
of
of
of
of
of
Overall Cable Packing
of
Maximum Nominal Number Maximum Screened Pair
PE
Armour Outer Diameter Weight Length
Unscreened Pair Insulation Screening PE
Cores Induced
(Min.)
Tape
Bedding Inner
Wire
Sheath
Area
of
Resistance
Voltage
Sheath
(Min.)
of
Cores
at 20C
Number Nominal Number Nominal
Level Conductor
of
Diameter
of
Diameter
Pairs
of
Pairs
of
Wires
Wires
No.

KV

Sqmm

No.

Ohm/km

No.

mm

No.

mm

7.41

1.78

1.78

2.5
&
0.635

16

10

28.48

0.90

0.90

7.41

1.78

28

28.48

14

0.90

34

15

2.5
&
0.635

Drum
Size

Approx.
Gross
Weight

mm

mm

mm

mm

mm

mm

mm

Kg/Km

Metre
10%

0.5

0.09

1.0

1.25

1.7

24.0

930

1000

D-14

1050

0.8

0.075

1.8

1.0

2.0

1.9

44.0

2900

750

D-22

2640

All conductors circular solid (Class 1).


In 16 core Pilot Cable polyester laminated aluminium screen is provided over pairs for Solkor protection and Telephone System.
In 34 core Pilot Cable individual pairs for Solkor protection system and intertripping and interlocking system are screened with
plain copper tape. Also an overall screen of plain copper tape is provided over PE bedding.
Cables conform to MEW Kuwait and ESI 09-6 specification.

Kg

Gulf Cable & Electrical Ind. Co.


INSTALLATION CONDITIONS
1.

23

Continuous operating temperature of conductor


a) PVC type-5 insulated
b) XLPE insulated

::
:

85 C
90 C

2.

Ambient temperature

52 C

3.

Temperature of ground

35 C

4.

Depth of laying in ground :a) LV Cables


b) MV Cables

:
:

750 mm
1000 mm

Thermal resistivity of soil

1.2 C .m/W

5.

OTHER CONDITIONS
MEDIUM VOLTAGE CABLES 6.6 KV TO 33 KV
1.

SINGLE CORE CABLES


i) Three cables, trefoil, in air, two point bonding, separated from wall.
ii) Three cables flat with a gap of one cable diameter installed vertically in air,
separated from wall. Single point or cross bonded.
iii) Three cables with gap one cable diameter laid horizontally underground.

2.

MULTI CORE CABLES


i) Single cable touching wall installed in air.
ii) Single isolated buried cable in ground.

Gulf Cable & Electrical Ind. Co.


INSTALLATION DETAILS
I)

IN AIR (Installed on non-continuous brackets, ladder supports or cleats)


a) Single Core
1) Two cables spaced De vertical

2) Three cables trefoil

3) Three cables (flat) spaced De vertical

b) Multi Core
1) Single cable touching wall

II)

IN GROUND

a) Single Core
1) Two cables spaced De horizontal

2) Three cables trefoil

3) Three cables (flat) spaced De horizontal

b) Multi Core
1) Single isolated buried cable

III)

IN DUCT ( Multi Core Cables)


1) Single isolated buried ducts

NOTE:De
D

:
:

External diameter of cable


Depth of Laying

24

Gulf Cable & Electrical Ind. Co.


MEDIUM VOLTAGE CABLES 3.8/6.6KV TO 19/33KV
COPPER OR ALUMINIUM CONDUCTOR
XLPE INSULATED CABLES

25

A. SINGLE CORE CABLES


CURRENT CARRYING CAPACITY IN AMPERES
Nominal
Area
of
Conductor
Sqmm

In Air

In Ground

Copper
Trefoil

Aluminium

Copper

Flat

Trefoil

Flat

Trefoil

Aluminium
Flat

Trefoil

Flat

35
50
70

152
182
227

170
203
254

117
140
175

132
158
198

154
182
222

160
189
231

119
141
172

124
146
179

95
120
150

274
318
360

313
360
410

211
244
278

240
278
316

264
300
335

275
314
352

204
232
261

212
242
272

185
240
300

410
481
545

470
560
640

330
380
430

365
435
498

376
428
472

399
464
525

294
339
379

309
360
407

400
500
630

625
700
784

750
873
1035

500
570
655

585
685
810

517
553
605

600
684
772

427
465
516

468
537
615

***

I.a.2

I.a.3

I.a.2

I.a.3

II.a.2

II.a.3

II.a.2

II.a.3

B. THREE CORE CABLES


CURRENT CARRYING CAPACITY IN AMPERES
Nominal Area
of Conductor
Sqmm

In Air

In Ground

Copper

Aluminium

Copper

Aluminium

35
50
70

130
160
196

100
120
151

145
170
210

110
130
160

95
120
150

240
275
312

184
214
240

250
284
318

193
220
246

185
240
300

355
415
469

277
326
370

360
410
458

279
323
362

400

530

427

510

411

***

I.b.1

I.b.1

II.b.1

II.b.1

Note
Above values can be applied safely for unarmoured cables also.
*** Installation condition (please refer at the beginning of this section).

Gulf Cable & Electrical Ind. Co.

26

RATING FACTORS FOR VARIATION IN


AMBIENT TEMPERATURE FOR CABLES LAID IN AIR
Ambient temperature C
XLPE insulated cables

25

30

35

40

45

50

52

55

60

1.37

1.30

1.24

1.17

1.09

1.03

1.00

0.95

0.88

RATING FACTORS FOR VARIATION IN GROUND TEMPERATURE


FOR CABLES LAID DIRECT IN GROUND OR IN DUCTS
Ground temperature C

15

20

25

30

35

40

45

XLPE insulated cables

1.16

1.13

1.08

1.03

1.00

0.95

0.90

RATING FACTORS FOR DEPTHS OF LAYING FOR


CABLES LAID DIRECT IN GROUND OR IN DUCTS
Depth of
Laying

1.9/3.3 KV to 19/33 KV Cables


Cables Laid in Ground

Metre

Upto
300 Sqmm

Above
300 Sqmm

0.50
0.60
0.75

0.80
1.00
1.25

1.020
1.000
0.980

1.031
1.000
0.979

1.50
1.75
2.00

0.969
0.959
0.939

0.969
0.948
0.928

2.50
3.00
or more

0.929
0.918

0.918
0.907

Depth of laying is measured from surface of ground to the centre of a Cable/Duct or to the centre of a trefoil group of Cables/ ducts as the case may be.

Gulf Cable & Electrical Ind. Co.

27

GROUP RATING FACTORS (1.9/3.3 KV TO 19/33 KV CABLES) LAID IN GROUND


No. of
Circuits

3 Single Core Cable in Trefoil and Laid Flat Touching Horizontal Formation

Multicore Cable in Horizontal Formation

Spacing Between Centres of Cable Group (M)

Spacing Between Cables (M)

Touching

2
3
4
5
6

Trefoil

Flat

0.15

0.30

0.45

0.60

Touching

0.15

0.30

0.45

0.60

0.78
0.66
0.60
0.55
0.52

0.80
0.69
0.63
0.58
0.55

0.81
0.71
0.65
0.61
0.58

0.85
0.76
0.72
0.68
0.66

0.88
0.80
0.76
0.73
0.72

0.90
0.83
0.80
0.77
0.76

0.80
0.69
0.63
0.57
0.55

0.85
0.75
0.70
0.66
0.63

0.89
0.80
0.77
0.73
0.71

0.90
0.84
0.80
0.78
0.76

0.92
0.86
0.84
0.81
0.80

Gulf Cable & Electrical Ind. Co.

28

RATING FACTORS FOR VARIATION IN THERMAL RESISTIVITY OF SOIL


TWIN OR MULTI -CORE CABLES LAID DIRECT IN THE GROUND
Nominal Area
of Conductor
Sqmm

Thermal Resistivity of Soil in C m/w


0.7

0.8

0.9

1.0

1.2

1.5

2.0

2.5

3.0

1.5/2.5
4
6

1.12
1.13
1.14

1.09
1.10
1.10

1.07
1.07
1.07

1.04
1.05
1.05

1.0
1.0
1.0

0.94
0.94
0.93

0.86
0.85
0.85

0.80
0.79
0.79

0.75
0.74
0.74

0.70
0.69
0.68

0.66
0.65
0.64

10
16
25

1.15
1.16
1.17

1.11
1.12
1.13

1.08
1.08
1.09

1.05
1.05
1.05

1.0
1.0
1.0

0.93
0.93
0.93

0.85
0.84
0.83

0.78
0.77
0.77

0.73
0.72
0.71

0.67
0.66
0.65

0.63
0.62
0.61

35
50
70

1.17
1.17
1.18

1.13
1.13
1.14

1.09
1.09
1.09

1.06
1.06
1.06

1.0
1.0
1.0

0.92
0.92
0.92

0.83
0.83
0.83

0.76
0.76
0.75

0.71
0.71
0.70

0.65
0.65
0.64

0.61
0.61
0.60

95
120
150

1.18
1.19
1.19

1.14
1.14
1.14

1.09
1.10
1.10

1.06
1.06
1.06

1.0
1.0
1.0

0.92
0.92
0.92

0.83
0.82
0.82

0.75
0.75
0.75

0.70
0.69
0.69

0.64
0.63
0.63

0.60
0.60
0.59

185
240
300/400

1.19
1.20
1.20

1.14
1.15
1.15

1.10
1.10
1.10

1.06
1.07
1.07

1.0
1.0
1.0

0.92
0.92
0.92

0.82
0.81
0.81

0.74
0.74
0.74

0.69
0.69
0.69

0.63
0.63
0.63

0.59
0.59
0.59

3.5

4.0

RATING FACTORS FOR VARIATION IN THERMAL RESISTIVITY OF SOIL


FOR TWO OR THREE SINGLE - CORE CABLES LAID DIRECT IN THE GROUND
Nominal Area
of Conductor
Sqmm

Thermal Resistivity of Soil in C m/w


0.7

0.8

0.9

1.0

1.2

1.5

2.0

2.5

3.0

50
70
95

1.21
1.22
1.22

1.16
1.16
1.16

1.11
1.12
1.12

1.07
1.07
1.07

1.0
1.0
1.0

0.91
0.91
0.91

0.81
0.81
0.81

0.73
0.73
0.73

0.68
0.68
0.68

0.63
0.63
0.63

0.59
0.59
0.59

120
150
185

1.22
1.22
1.22

1.16
1.16
1.17

1.12
1.12
1.12

1.07
1.07
1.07

1.0
1.0
1.0

0.91
0.91
0.91

0.81
0.81
0.81

0.73
0.73
0.73

0.68
0.68
0.68

0.63
0.63
0.62

0.59
0.59
0.59

240
300
400

1.23
1.23
1.23

1.17
1.17
1.17

1.12
1.12
1.12

1.07
1.07
1.07

1.0
1.0
1.0

0.91
0.91
0.91

0.80
0.80
0.80

0.73
0.73
0.73

0.68
0.68
0.67

0.62
0.62
0.62

0.59
0.59
0.58

500
630
800

1.23
1.23
1.23

1.17
1.17
1.17

1.12
1.12
1.12

1.07
1.07
1.07

1.0
1.0
1.0

0.91
0.91
0.91

0.80
0.80
0.80

0.73
0.73
0.72

0.67
0.67
0.66

0.62
0.61
0.61

0.58
0.58
0.58

1000

1.24

1.18

1.12

1.07

1.0

0.91

0.80

0.72

0.66

0.61

0.58

3.5

4.0

Gulf Cable & Electrical Ind. Co.

29

RATING FACTORS FOR VARIATION IN THERMAL RESISTIVITY OF SOIL


TWIN OR MULTI-CORE CABLES LAID IN SINGLE -WAY DUCTS
Nominal Area
of Conductor
Sqmm

Thermal Resistivity of Soil in C m/w


0.7

0.8

0.9

1.0

1.2

1.5

2.0

2.5

3.0

1.5/2.5
4
6

1.04
1.04
1.05

1.03
1.04
1.04

1.02
1.03
1.03

1.02
1.02
1.02

1.0
1.0
1.0

0.98
0.97
0.97

0.94
0.94
0.93

0.91
0.90
0.90

0.88
0.87
0.86

0.86
0.85
0.84

0.83
0.82
0.81

10
16
25

1.05
1.06
1.06

1.04
1.04
1.05

1.03
1.03
1.03

1.02
1.02
1.02

1.0
1.0
1.0

0.97
0.97
0.96

0.93
0.92
0.92

0.89
0.88
0.88

0.86
0.85
0.84

0.83
0.82
0.82

0.80
0.79
0.78

35
50
70

1.06
1.07
1.07

1.05
1.05
1.05

1.03
1.03
1.04

1.02
1.02
1.02

1.0
1.0
1.0

0.96
0.96
0.96

0.92
0.91
0.91

0.87
0.87
0.86

0.83
0.83
0.82

0.81
0.80
0.79

0.77
0.77
0.76

95
120
150

1.07
1.08
1.09

1.06
1.06
1.06

1.04
1.04
1.04

1.02
1.03
1.03

1.0
1.0
1.0

0.96
0.95
0.95

0.91
0.90
0.90

0.86
0.85
0.85

0.82
0.81
0.80

0.78
0.78
0.77

0.75
0.74
0.73

185
240
300/400

1.09
1.09
1.10

1.07
1.07
1.07

1.05
1.05
1.05

1.03
1.03
1.03

1.0
1.0
1.0

0.95
0.95
0.95

0.89
0.89
0.88

0.84
0.84
0.83

0.80
0.79
0.78

0.76
0.76
0.75

0.72
0.72
0.71

3.5

4.0

RATING FACTORS FOR VARIATION IN THERMAL RESISTIVITY


OF SOIL TWO SINGLE - CORE CABLES IN DUCTS
Nominal Area
of Conductor
Sqmm

Thermal Resistivity of Soil in C m/w


0.7

0.8

0.9

1.0

1.2

1.5

2.0

2.5

3.0

50
70
95

1.08
1.08
1.08

1.06
1.06
1.07

1.04
1.05
1.05

1.03
1.03
1.03

1.0
1.0
1.0

0.96
0.96
0.95

0.90
0.90
0.89

0.85
0.84
0.84

0.81
0.80
0.80

0.77
0.76
0.75

0.74
0.73
0.72

120
150
185

1.09
1.09
1.09

1.07
1.07
1.07

1.05
1.05
1.05

1.03
1.03
1.03

1.0
1.0
1.0

0.95
0.95
0.95

0.89
0.88
0.88

0.83
0.83
0.83

0.79
0.79
0.78

0.75
0.74
0.74

0.71
0.71
0.70

240
300
400

1.10
1.10
1.11

1.08
1.08
1.08

1.05
1.06
1.06

1.04
1.04
1.04

1.0
1.0
1.0

0.95
0.95
0.94

0.88
0.87
0.87

0.82
0.82
0.82

0.78
0.77
0.77

0.73
0.72
0.72

0.70
0.69
0.68

500
630
800

1.12
1.12
1.13

1.08
1.09
1.10

1.06
1.06
1.07

1.04
1.04
1.04

1.0
1.0
1.0

0.94
0.94
0.94

0.87
0.87
0.86

0.81
0.81
0.80

0.76
0.76
0.75

0.71
0.71
0.71

0.68
0.67
0.67

1000

1.13

1.10

1.07

1.04

1.0

0.94

0.86

0.80

0.75

0.70

0.66

3.5

4.0

Gulf Cable & Electrical Ind. Co.

30

RATING FACTORS FOR VARIATION IN THERMAL RESISTIVITY


OF SOIL THREE SINGLE- CORE CABLES IN DUCTS
Nominal Area
of Conductor
Sqmm

Thermal Resistivity of Soil in C m/w


0.7

0.8

0.9

1.0

1.2

1.5

2.0

2.5

3.0

50
70
95

1.11
1.12
1.12

1.08
1.09
1.09

1.06
1.06
1.06

1.04
1.04
1.04

1.0
1.0
1.0

0.94
0.94
0.94

0.87
0.87
0.87

0.82
0.81
0.81

0.77
0.76
0.76

0.73
0.72
0.72

0.69
0.68
0.68

120
150
185

1.13
1.13
1.13

1.10
1.10
1.10

1.07
1.07
1.07

1.04
1.04
1.04

1.0
1.0
1.0

0.94
0.94
0.93

0.86
0.86
0.86

0.80
0.80
0.79

0.75
0.75
0.75

0.72
0.71
0.70

0.67
0.67
0.67

240
300
400

1.14
1.14
1.14

1.11
1.11
1.11

1.07
1.08
1.08

1.04
1.05
1.05

1.0
1.0
1.0

0.93
0.93
0.93

0.86
0.85
0.85

0.79
0.79
0.78

0.74
0.74
0.73

0.70
0.69
0.68

0.66
0.65
0.65

500
630
800

1.15
1.15
1.16

1.11
1.12
1.12

1.08
1.08
1.09

1.05
1.05
1.05

1.0
1.0
1.0

0.93
0.93
0.93

0.85
0.84
0.84

0.78
0.78
0.77

0.73
0.72
0.72

0.68
0.68
0.67

0.64
0.64
0.64

1000

1.16

1.13

1.09

1.05

1.0

0.92

0.84

0.77

0.71

0.67

0.63

3.5

4.0

Gulf Cable & Electrical Ind. Co.

31

3.8/6.6 KV CABLES
A.C. RESISTANCE, REACTANCE AND CAPACITANCE VALUES
Conductor
size

* Single Core Cables


A.C. Resistance at 90C

3-Core Cables

Reactance (50 Hz)

Capacitance

A.C. Resistance at 90C


Copper
(/km)

Capacitance

(/km)

( F/Km)

Copper
(/km)

Aluminium
(/km)

Trefoil
(/km)

Flat*
(/km)

35
50
70

0.668
0.494
0.342

1.11
0.822
0.568

0.140
0.131
0.123

0.198
0.189
0.181

0.29
0.33
0.37

0.668
0.494
0.342

1.11
0.922
0.568

0.108
0.103
0.098

0.30
0.33
0.38

95
120
150

0.247
0.196
0.159

0.411
0.325
0.265

0.117
0.112
0.109

0.175
0.170
0.167

0.42
0.47
0.51

0.247
0.196
0.159

0.411
0.325
0.265

0.094
0.090
0.088

0.43
0.48
0.52

185
240
300

0.127
0.0974
0.0782

0.211
0.161
0.129

0.107
0.103
0.101

0.165
0.161
0.159

0.55
0.60
0.61

0.127
0.0971
0.0778

0.211
0.162
0.130

0.086
0.083
0.082

0.56
0.61
0.62

400
500
630

0.0621
0.0495
0.0398

0.101
0.0792
0.0623

0.097
0.097
0.094

0.156
0.155
0.152

0.64
0.67
0.75

0.0614
-

0.102
-

0.080
-

0.65
-

Sq.mm

( F/km)

Aluminium
(/km)

Reactance
(50 Hz)

* Twice Cable diameter spacing between centres.

6.35/11 KV CABLES
A.C. RESISTANCE, REACTANCE AND CAPACITANCE VALUES
Conductor
size

* Single Core Cables


A.C. Resistance at 90C

3-Core Cables

Reactance (50 Hz)

Capacitance

A.C. Resistance at 90C


Copper
(/km)

Capacitance

Copper
(/km)

Aluminium
(/km)

Trefoil
(/km)

Flat*
(/km)

35
50
70

0.668
0.494
0.342

1.11
0.822
0.568

0.142
0.135
0.128

0.20
0.194
0.186

0.23
0.26
0.29

0.668
0.494
0.342

1.11
0.822
0.568

0.116
0.111
0.105

0.24
0.26
0.29

95
120
150

0.247
0.196
0.159

0.411
0.325
0.265

0.121
0.116
0.114

0.179
0.174
0.173

0.33
0.36
0.39

0.247
0.196
0.159

0.411
0.325
0.265

0.100
0.097
0.093

0.34
0.37
0.40

185
240
300

0.127
0.0973
0.0782

0.211
0.161
0.129

0.111
0.106
0.102

0.169
0.164
0.161

0.42
0.47
0.51

0.128
0.097
0.0778

0.211
0.161
0.129

0.091
0.087
0.085

0.43
0.48
0.52

400
500
630

0.0620
0.0494
0.0396

0.101
0.0792
0.0623

0.099
0.098
0.094

0.157
0.156
0.152

0.57
0.63
0.71

0.0614
-

0.101
-

0.082
-

0.59
-

Sq.mm

*Twice Cable diameter spacing between centres.

( F/km)

Aluminium
(/km)

Reactance
(50 Hz)
(/km)

( F/Km)

Gulf Cable & Electrical Ind. Co.

32

8.7/15 KV CABLES
A.C. RESISTANCE, REACTANCE AND CAPACITANCE VALUES
Conductor
size

* Single Core Cables


A.C. Resistance at 90C

3-Core Cables

Reactance (50 Hz)

Capacitance

A.C. Resistance at 90C


Copper
(/km)

Capacitance

(/km)

( F/Km)

Copper
(/km)

Aluminium
(/km)

Trefoil
(/km)

Flat*
(/km)

35
50
70

0.668
0.494
0.342

1.11
0.822
0.568

0.147
0.141
0.133

0.206
0.199
0.191

0.19
0.21
0.23

0.668
0.494
0.342

1.11
0.822
0.568

0.124
0.119
0.112

0.19
0.21
0.24

95
120
150

0.247
0.196
0.159

0.411
0.325
0.265

0.128
0.122
0.118

0.185
0.180
0.176

0.26
0.29
0.31

0.247
0.196
0.159

0.411
0.325
0.265

0.106
0.102
0.099

0.27
0.29
0.31

185
240
300

0.127
0.0973
0.0780

0.211
0.161
0.129

0.115
0.109
0.106

0.173
0.167
0.164

0.33
0.37
0.40

0.127
0.0970
0.0778

0.211
0.161
0.129

0.096
0.092
0.090

0.34
0.38
0.41

400
500
630

0.0619
0.0493
0.0395

0.101
0.0792
0.0622

0.104
0.101
0.097

0.162
0.159
0.155

0.45
0.50
0.55

0.0614
-

0.101
-

0.086
-

0.46
-

Sq.mm

( F/km)

Aluminium
(/km)

Reactance
(50 Hz)

* Twice Cable diameter spacing between centres.

12.7/22 KV CABLES
A.C. RESISTANCE, REACTANCE AND CAPACITANCE VALUES
Conductor
size

* Single Core Cables


A.C. Resistance at 90C

3-Core Cables

Reactance (50 Hz)

Capacitance

A.C. Resistance at 90C


Copper
(/km)

Capacitance

(/km)

( F/Km)

Copper
(/km)

Aluminium
(/km)

Trefoil
(/km)

Flat*
(/km)

35
50
70

0.668
0.494
0.342

1.11
0.822
0.568

0.138
0.132
0.125

0.196
0.190
0.183

0.19
0.22

0.668
0.494
0.342

1.11
0.822
0.568

0.131
0.125
0.118

0.17
0.18
0.20

95
120
150

0.247
0.196
0.159

0.411
0.325
0.265

0.118
0.113
0.110

0.176
0.171
0.168

0.24
0.26
0.28

0.247
0.196
0.159

0.411
0.325
0.265

0.112
0.107
0.104

0.23
0.25
0.27

185
240
300

0.127
0.0974
0.0782

0.211
0.161
0.129

0.107
0.102
0.099

0.164
0.160
0.157

0.30
0.34
0.37

0.127
0.0970
0.0778

0.211
0.161
0.129

0.101
0.096
0.093

0.29
0.32
0.35

400
500
630

0.0621
0.0495
0.0398

0.101
0.0791
0.0621

0.096
0.093
0.090

0.154
0.151
0.148

0.40
0.44
0.49

0.0614
-

0.101
-

0.090
-

0.39
-

Sq.mm

*Twice Cable diameter spacing between centres.

( F/km)

Aluminium
(/km)

Reactance
(50 Hz)

Gulf Cable & Electrical Ind. Co.

33

19/33 KV CABLES
A.C. RESISTANCE, REACTANCE AND CAPACITANCE VALUES
Conductor
size

* Single Core Cables


A.C. Resistance at 90C

3-Core Cables

Reactance (50 Hz)

Capacitance

A.C. Resistance at 90C


Copper
(/km)

Capacitance

(/km)

( F/Km)

Copper
(/km)

Aluminium
(/km)

Trefoil
(/km)

Flat*
(/km)

50
70
95

0.494
0.342
0.247

0.822
0.568
0.411

0.157
0.148
0.140

0.215
0.206
0.198

0.14
0.15
0.17

0.494
0.342
0.246

0.817
0.568
0.411

0.138
0.130
0.123

0.14
0.16
0.18

120
150
185

0.196
0.159
0.127

0.325
0.265
0.211

0.134
0.132
0.128

0.192
0.190
0.186

0.19
0.20
0.21

0.196
0.159
0.127

0.325
0.264
0.211

0.118
0.114
0.110

0.19
0.20
0.22

240
300
400

0.0972
0.0780
0.0617

0.161
0.129
0.101

0.121
0.118
0.113

0.179
0.176
0.172

0.24
0.25
0.28

0.0970
0.0777
-

0.161
0.129
-

0.105
0.102
-

0.24
0.26
-

500

0.0491

0.0793

0.110

0.168

0.31

Sq.mm

* Twice Cable diameter spacing between centres.

( F/km)

Aluminium
(/km)

Reactance
(50 Hz)

Gulf Cable & Electrical Ind. Co.


SHORT CIRCUIT CURRENT CURVES FOR
COPPER CONDUCTOR XLPE INSULATED CABLES

34

Isc = 0.14

CONDUCTOR AREA Sqmm

MAX. SHORT CIRCUIT CURRENT KA

Isc - Short Circuit Current in KA


A - Conductor Area in Sqmm
t - Short Circuit Time in Sec.

SHORT CIRCUIT TIME (Sec.) t.

Gulf Cable & Electrical Ind. Co.


SHORT CIRCUIT CURRENT CURVES FOR
ALUMINIUM CONDUCTOR XLPE INSULATED CABLES

35

Isc = 0.094

CONDUCTOR AREA Sqmm

MAX. SHORT CIRCUIT CURRENT KA

Isc - Short Circuit Current in KA


A - Conductor Area in Sqmm
t - Short Circuit Time in Sec.

SHORT CIRCUIT TIME (Sec.) t.

Gulf Cable & Electrical Ind. Co.


DRUMS SIZES AND DIMENSIONS

A - Flange diameter (excluding lagging), mm


B - Barrel diameter, mm
C - Overall width, mm
D - Traverse width, mm
E - Minimum spindle hole diameter, mm

36

DIMENSIONS
Drum Size
D-No

D-6
D-7
D-8

600
700
800

250
325
375

470
570
570

400
500
500

110
110
110

D-9
D-10
D-11

900
1000
1100

425
500
575

620
690
740

550
600
650

110
110
110

D-12
D-14
D-16

1200
1400
1600

675
800
950

950
950
970

850
850
850

110
110
110

D-18
D-19
D-20

1800
1900
2000

1100
1100
1300

1220
1230
1235

1100
1100
1100

110
110
110

D-21
D-22
D-23

2100
2200
2340

1150
1400
1200

1290
1390
1795

1100
1250
1625

110
110
110

D-24
D-25-S
D-25
D-26

2400
2540
2540
2600

1200
1200
1400
1400

1795
1825
1800
1970

1625
1625
1625
1800

110
110
110
110

Drum dimensions in actual deliveries are subject to change without notice.