You are on page 1of 124

3

INTRODUCTION ..........................................................................................................................................................................................................5&6
SECTION ONE - FIXED WIRING & MAINS CABLES
PVC insulated wiring cable 6491X (1.5mm2 to 630mm2) ..............................................................................................................................8
PVC insulated PVC sheathed surface wiring cable type 6181Y (1mm2 to 35mm2) ............................................................................9
XLPE insulated mains and control cable (1.5mm2 to 16mm2)....................................................................................................................10
XLPE insulated mains cable (25mm2 to 400mm2) ..........................................................................................................................................11
XLPE insulated mains cable 3300v (16mm2 to 400mm2) ............................................................................................................................12
XLPE insulated mains cable with aluminium conductors (25mm2 to 300mm2)................................................................................13
XLPE insulated single core non-armoured mains cable (50mm2 to 1000mm2)..................................................................................14
XLPE insulated single core armoured mains cable (50mm2 to 1000mm2) ..........................................................................................15
XLPE insulated non-armoured and armoured single core cable for cathodic protection (6mm2 to 185mm2) ....................16
Low smoke insulated wiring cable 6491B (1.5mm2 to 630mm2)..............................................................................................................17
XLPE insulated low smoke mains and control cable (1.5mm2 to 16mm2) ............................................................................................18
XLPE insulated low smoke mains cable (25mm2 to 400mm2) ..................................................................................................................19
XLPE insulated low smoke single core non-armoured mains cable 1000 volt (50mm2 to 1000mm2) ....................................20
XLPE insulated low smoke single core armoured mains cable (50mm2 to 1000mm2)....................................................................21
Mechanically protected wiring cable (1.0mm2 to 6.0mm2) ........................................................................................................................22
XLPE insulated medium voltage mains cable 11000 volt (25mm2 to 400mm2) and (50mm2 to 630mm2) ..........................23
XLPE insulated medium voltage mains cable 11000 volt (95mm2 to 300mm2) ................................................................................24
XLPE insulated low smoke medium voltage mains cable 11000 volt (35mm2 to 300mm2 and (50mm2 to 630mm2) ............25
Paper insulated medium voltage mains cable 11000 volt (25mm2 to 400mm2) ..............................................................................26
Paper insulated corrugated aluminium sheathed medium voltage mains cable 11000 volt (95mm2 to 300mm2)..........27
XLPE insulated mains cable with 60% conductivity in armour. (Mines & quarries & British Coal) (10mm2 to 300mm2)........28
XLPE insulated lead sheathed control cable for petro-chemical industries (1.5mm2 to 4mm2) ................................................29
XLPE insulated lead sheathed mains cable for petro-chemical industries (25mm2 to 300mm2) ..............................................30
XLPE insulated lead sheathed mains cable for petro-chemical industries (1.5mm2 to 16mm2) ................................................31
XLPE insulated lead sheathed mains cable for petro-chemical industries 3300 volt (25mm2 to 300mm2) ..........................32
PVC insulated single phase split and straight concentric service cable (4mm2 to 35mm2)..........................................................33
SECTION TWO - FLEXIBLE CABLES
PVC insulated flexible cords type 318*y (0.5mm2 to 2.5mm2) ..................................................................................................................36
PVC insulated heat resisting flexible cords type 309*y (0.5mm2 to 2.5mm2)......................................................................................37
LSF insulated flexible cords type 318*B (0.75mm2 to 2.5mm2)..................................................................................................................38
PVC insulated flexible power and control cable type YY (0.75mm2 to 1.5mm2) and (2.5mm2 to 50mm2) ..............39 & 40
LSF insulated flexible control cable type YY (1.5mm2 to 4.0mm2) ........................................................................................................41
PVC insulated braided flexible control cable type SY (0.75mm2 to 2.5mm2) and (4mm2 to 95mm2) ........................42 & 43
PVC insulated braid screened flexible power and control cable type CY (0.75mm2 to 10mm2) ..............................................44
Tri-rated and Bi-rated switch gear and control panel wire (0.5mm2 to 400mm2) ............................................................................45
EPR insulated HOFR sheathed flexible power and control cable (0.75mm2 to 2.5mm2) ................................................................46
EPR insulated heavy duty HOFR sheathed flexible mains cable (4mm2) ..............................................................................................47
EPR insulated HOFR sheathed power and control cable (6mm2 to 630mm2) ....................................................................................48
Rubber insulated neoprene sheathed flexible power cable (1.5mm2 to 300mm2) ..........................................................................49
EPR insulated braided screen flexible mains and control cable (1.0mm2 to 16mm2)......................................................................50
EPR insulated flexible coil lead (0.5mm2 to 400mm2)....................................................................................................................................51
EPR insulated flexible welding cable type 0361TQ (16mm2 to 185mm2) ............................................................................................52
Rubber insulated flat cable (1.5mm2 to 70mm2) and PVC insulated flat cable (1.5mm2 to 95mm2) ......................................53
Silicone insulated flexible cable (0.75mm2 to 2.5mm2) ................................................................................................................................54

CONTENTS

Page

CONTENTS

SECTION THREE - INSTRUMENTATION, CONTROL & COMMUNICATION CABLES


Control and instrumentation cable non-armoured with collective screen (0.5mm2 to 1.5mm2) ..............................................56
Control and instrumentation cable non-armoured with individual and collective screens (0.5mm2 to 1.5mm2)..............57
Control and instrumentation cable armoured with collective screen (0.5mm2 to 2.5mm2) ........................................................58
Control and instrumentation cable armoured with individual and collective screens (0.5mm2 to 1.5mm2)........................59
Control and instrumentation cable lead sheathed armoured with collective screen (0.75mm2 to 1.5mm2) ......................60
Control and instrumentation cable lead sheathed armoured with individual and collective screens (0.75mm2 to 1.5mm2) ..........61
BS5308 part 1 core identification ..........................................................................................................................................................................62
BS5308 part 2 core identification ..........................................................................................................................................................................63
Instrumentation cable to British Steel specification CES20 type 134 (0.75mm2) ............................................................................64
Instrumentation cable to British Steel specification CES20 type 143 (0.75mm2) ............................................................................65
Internal telephone cable type CW1308 ..............................................................................................................................................................66
PVC insulated multipair armoured cable to ESI standard ................................................................................................................67 & 68
ESI 09-6 section 3.6 core identification ................................................................................................................................................................69
ESI 09-6 section 4.5 core identification ................................................................................................................................................................70
Petroleum jelly filled telemetry cable to BS3573 and CW1128/1198 ....................................................................................................71
Defence screened multicore cable C type..........................................................................................................................................................72
Defence standard 61-12 parts 4 &5 core identification ..............................................................................................................................73
PVC insulated collective screened thermocouple extension and compensating cable (0.75mm2)............................................74
PVC insulated armoured traffic signal cable, loop feeder cable and loop detector cable ..................................................75 & 76
Colour coding of thermocouple extension and compensating cable ....................................................................................................77
SECTION FOUR - RAILWAY CABLES
Signalling cables types A1, A2, A3, B1 and B2 (0.75mm2 to 95mm2) ......................................................................................................80
Signalling cables types C1, C2, C3, D1, D2, D3, E1, E2 & E3 (0.75mm2 to 35mm2) ..........................................................................81
Power cables and Trackfeeder cables (16mm2 to 1000mm2)......................................................................................................................82
SECTION FIVE - MARINE & OFFSHORE CABLES
EPR insulated non-armoured shipwiring cable (1.5mm2 to 6mm2) ........................................................................................................84
EPR insulated non-armoured shipwiring cable (10mm2 to 630mm2) ....................................................................................................85
EPR insulated braided armour shipwiring cable (1.5mm2 to 4mm2) ......................................................................................................86
EPR insulated braided armoured shipwiring cable (6mm2 to 300mm2)................................................................................................87
EPR insulated single core braided shipwiring cable (6mm2 to 630mm2) ..............................................................................................88
SECTION SIX - FIREPROOF CABLES
Mineral insulated cable ..............................................................................................................................................................................................90
Fire resistant security cable (1.0mm2 to 4mm2) ..............................................................................................................................................91
Fire resistant power and control cable (1.5mm2 to 16mm2) ......................................................................................................................92
Fire resistant power cable (25mm2 to 400mm2) ..............................................................................................................................................93
SECTION SEVEN - INSTALLATION ACCESSORIES ................................................................................................................................................95
SECTION EIGHT - CURRENT RATINGS ................................................................................................................................................................109

Cleveland Cable Company, established in 1978, is


undoubtedly the foremost distributor of electrical
cables in Great Britain and possibly Europe.
The Head Office and principal
stocking location is located at
Middlesbrough in the North East of
England. This site covers an area of
twelve acres and includes over
160,000 square feet of warehousing.
Additionally there are regional depots
at Bristol, Glasgow, London, Milton
Keynes, Newcastle and Warrington.
Each location holds comprehensive
stocks and is equipped with the most
modern handling and measuring
equipment. Deliveries
are made by our own fleet of
purpose-designed vehicles, all of
which are fitted with hydraulic
lifting equipment for safe offloading
onsite and also efficient collection of
empty drums.

CLEVELAND CABLE COMPANY

Cleveland Cable Company

CLEVELAND CABLE COMPANY

As is illustrated within our catalogue, we stock an


extremely large range of cables for every
conceivable application. All types shown are
considered as standard items to our range and are
always available for immediate delivery. Our stocks
are extremely large and unrivalled in the industry.
We are fortunate to have a very
experienced and dedicated team of
people who are able to assist and
advise. Additionally our policy of
continuing investment in the best
available technology, warehousing,
handling and measuring equipment
and delivery vehicles enables us to
guarantee all our customers an
extremely high quality service.
Enquiries are welcome from
customers worldwide. Our export
service is efficient and reliable with
the ability to ship by air or sea freight
to any destination.

Please feel free to contact the depot of your


choice for an immediate, professional
and trouble free service.

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND


MAINS CABLES

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES


Stranded plain annealed compacted circular copper conductor, PVC outer sheath.
Ref 6491X. Harmonised code HO7V-R. 450 volts grade to BS6004.
Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE

CONDUCTOR
SIZE (MM2)

STRANDING
(MM)

WEIGHT
KG/KM

6491X1/5
6491X2/5
6491X4
6491X6
6491X10
6491X16
6491X25
6491X35
6491X50
6491X70
6491X95
6491X120
6491X150
6491X185
6491X240
6491X300
6491X400
6491X500
6491X630

1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0

7/0.53
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
61/3.20
127/2.50

21
35
50
71
120
180
280
380
510
720
990
1200
1500
1900
2500
3000
3950
4950
6250

OVERALL
DIAMETER
(MM)
3.5
4.2
4.8
5.4
6.8
8.0
9.8
11.0
13.0
15.0
17.0
19.0
21.0
23.5
26.5
29.5
33.5
37.0
41.0

Temperature limits:
-15 to +70C.

4mm2-630mm2 - Brown, Black, Grey,


Blue, Green/Yellow.

Bending radius:
up to 10mm2 - 3 x overall diameter.
above 25mm2 - 6 x overall diameter.

Should not be installed at


temperatures below 0C.
Current ratings see page 110

Standard colours available:


1.5mm2 & 2.5mm2 - Brown, Black,
Grey, Blue, Green/Yellow, White,
Orange, Turquoise, Violet, Pink.

PVC INSULATED WIRING


CABLE 6491X
(1.5MM2 TO 630MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

Plain annealed stranded circular copper conductor, single core, PVC insulated,
PVC sheathed, Ref 6181 Y. 300/500 volts grade to BS6004. Brown/Grey or
Blue/Grey. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
6181Y1
6181Y1/5
6181Y2/5
6181Y4
6181Y6
6181Y10
6181Y16
6181Y25
6181Y35
6181Y50
6181Y70
6181Y95
6181Y120

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.0
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0

1/1.13
1/1.38
1/1.78
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78
19/2.14
19.2.52
37/2.03

NO. OF
CORES
1
1
1
1
1
1
1
1
1
1
1
1
1

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
28
4.5
36
5.1
51
6.0
75
6.8
98
7.4
150
8.8
220
10.5
340
12.5
440
13.5
540
14.38
750
15.3
1010
17.7
1250
19.3

GLAND
SIZE
(MM)
20/16
20/16
20/16
20/16
20/16
20S
20S
20
25
25A2
25A2
25A2
32A2

SINGLE
CLEAT

0.5
0.5
0.6

Temperature limits:
-15 to +70C.
Bending radius:
up to 10mm2 - 3 x overall diameter.
over 10mm2 - 4 x overall diameter.
Should not be installed at
temperatures below 0C.

Plain annealed stranded circular copper conductor, single core, XLPE insulated,
(LSOH) sheathed, Ref 6181B. 300/500 volts grade to BS7889. Brown/Grey or
Blue/Grey. Flame propagation to BS4066 PT1 and IEC332 PT1.
CCC
CODE
6181B1
6181B1/5
6181B2/5
6181B4
6181B6
6181B10
6181B16
6181B25
6181B35

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.0
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0

1/1.13
1/1.38
1/1.78
7/0.85
7/1.04
7/1.35
7/1.04
7/2.14
19/1.53

NO. OF
CORES

WEIGHT
KG/KM

OVERALL
DIAMETER

1
1
1
1
1
1
1
1
1

28
34
49
75
99
155
225
340
440

4.5
5.1
6.0
6.8
7.4
8.8
10.5
12.5
13.5

GLAND
REF
(MM)
20/16
20/16
20/16
20/16
20/16
20s
20s
20
25

PVC INSULATED
PVC SHEATHED SURFACE
WIRING CABLE
TYPE 6181Y
1MM2 TO 120MM2

XLPE INSULATED
LSOH SHEATHED SURFACE
WIRING CABLE
TYPE 6181B
1MM2 TO 35MM2
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

10

FIXED WIRING AND MAINS CABLES


Stranded plain annealed copper conductors, XLPE insulated, PVC bedding,
galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to
BS5467. Flame propagation to IEC 332 PT1 and BS4066 PT1.
CCC
CODE
XLPE2X1/5
XLPE3X1/5
XLPE4X1/5
XLPE5X1/5
XLPE7X1/5
XLPE8X1/5
XLPE10X1/5
XLPE12X1/5
XLPE19X1/5
XLPE27X1/5
XLPE37X1/5
XLPE48X1/5
XLPE2X2/5
XLPE3X2/5
XLPE4X2/5
XLPE5X2/5
XLPE7X2/5
XLPE10X2/5
XLPE12X2/5
XLPE19X2/5
XLPE27X2/5
XLPE37X2/5
XLPE48X2/5
XLPE2X4
XLPE3X4
XLPE4X4
XLPE5X4
XLPE7X4
XLPE12X4
XLPE19X4
XLPE27X4
XLPE2X6
XLPE3X6
XLPE4X6
XLPE5X6
XLPE7X6
XLPE2X10
XLPE3X10
XLPE4X10
XLPE5X10
XLPE7X10
XLPE2X16
XLPE3X16
XLPE4X16
XLPE5X16
XLPE7X16

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0
6.0
10.0
10.0
10.0
10.0
10.0
16.0
16.0
16.0
16.0
16.0

7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/1.04
7/1.04
7/1.04
7/1.04
7/1.04
7/1.35
7/1.35
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/1.70
7/1.70
7/1.70

Temperature limits:
-15 to +90C.
Bending radius:
6 x overall diameter.

XLPE INSULATED
MAINS AND
CONTROL CABLE
(1.5MM2 TO 16MM2)

Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
5 core and above - up to 6mm2 White with Black numbers.

NO. OF
CORES
2
3
4
5
7
8
10
12
19
27
37
48
2
3
4
5
7
10
12
19
27
37
48
2
3
4
5
7
12
19
27
2
3
4
5
7
2
3
4
5
7
2
3
4
5
7

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
305
12.4
338
12.9
381
13.7
426
14.2
488
15.6
501
16.7
777
18.7
817
20.1
1225
24.0
1553
27.7
1859
30.3
2236
32.3
352
13.2
397
13.8
452
14.7
549
16.3
685
17.6
1000
21.4
910
21.8
1500
26.1
1928
30.3
2360
33.4
3888
38.8
419
14.3
481
14.9
563
16.2
810
18.9
912
19.7
1400
25.0
1852
28.1
2630
35.2
498
15.4
639
17.4
795
18.3
970
20.5
1180
21.9
764
17.9
908
18.9
1064
20.3
1150
22.0
1560
25.0
900
21.9
1220
24.4
26.3
1410
1800
26.0
2237
28.1

GLAND
SIZE
(MM)
20/16
20/16
20S
20S
20S
20
20
20
25
32
32
32
20S
20S
20S
20S
20
25
25
25
32
32
40
20S
20S
20
20
20
25
32
40
20S
20
20
25
25
20
25
25
25
25
25
25
25
25
32

SINGLE
CLEAT
0.5
0.6
0.6
0.6
0.7
0.7
0.8
0.8
1.0
1.1
1.2
1.4
0.6
0.6
0.6
0.6
0.7
0.9
0.9
1.1
1.2
1.4
1.6
0.6
0.6
0.7
0.8
0.8
1.0
1.2
1.4
0.7
0.7
0.8
0.8
0.9
0.8
0.8
0.8
0.9
1.0
0.9
1.0
1.1
1.1
1.2

5 core and above - 10mm2 and


16mm2 - Brown, Black, Grey, Blue,
Green/Yellow
1.5 & 2.5 - 2,3,4 core also available in
white numbered cores to ESI 09-6
Should not be installed at
temperatures below 0C.
Current ratings, see page 112.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

11

Stranded plain annealed copper conductors, XLPE insulated, PVC bedding,


galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to
BS5467. Flame propagation to IEC 332 PT1 and BS4066 PT1.
CCC
CODE
6942X25
6943X25
6944X25
6945X25
6942X35
6943X35
6944X35
6945X35
6942X50
6943X50
6944X50
6945X50
6942X70
6943X70
6944X70
6945X70
6942X95
6943X95
6944X95
6945X95
6942X120
6943X120
6944X120
6942X150
6943X150
6944X150
6942X185
6943X185
6944X185
6942X240
6943X240
6944X240
6942X300
6943X300
6944X300
6942X400
6943X400
6944X400

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
25
25
25
25
35
35
35
35
50
50
50
50
70
70
70
70
95
95
95
95
120
120
120
150
150
150
185
185
185
240
240
240
300
300
300
400
400
400

7/2.14
7/2.14
7/2.14
7/2.14
7/2.52
7/2.52
7/2.52
7/2.52
19/1.78
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
19/2.14
19/2.52
19/2.52
19/2.52
19/2.52
37/2.03
37/2.03
37/2.03
37/2.25
37/2.25
37/2.25
37/2.52
37/2.52
37/2.52
61/2.25
61/2.25
61/2.25
61/2.52
61/2.52
61/2.52
61/2.85
61/2.85
61/2.85

NO. OF
CORES
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
1000
20.4
1500
23.6
1950
26.1
2370
31.0
1490
27.9
1940
29.6
2350
32.1
3150
35.0
1750
25.8
2225
28.5
2875
32.0
4260
40.0
2300
29.0
3025
32.2
4250
37.7
5685
43.0
3100
33.1
4275
37.0
5475
41.7
7700
52.0
3700
36.1
5250
40.4
7175
47.1
4400
39.3
6650
45.5
8475
51.4
5700
44.7
8000
49.8
10350
56.6
7100
49.0
10150
55.1
13000
63.0
8500
53.5
12400
60.2
15750
68.8
10650
58.0
14770
65.8
19950
75.4

GLAND
SIZE
(MM)
25
32
32
32
32
32
32
40
32
32
32
50S
32
32
40
50S
40
40
50S
50
40
50S
50
40
50S
50
50S
50
63S
50
63S
63
63S
63
75S
63S
75S
90

Temperature limits:
-15 to +90C.

Should not be installed at


temperatures below 0C.

Bending radius:
8 x overall diameter.

Current ratings, see page 112.

SINGLE
CLEAT

Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
5 core - Brown, Black, Grey, Blue,
Green/Yellow.

XLPE INSULATED
MAINS CABLE
(25MM2 TO 400MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

0.9
1.0
1.2
1.2
1.2
1.2
1.4
1.4
1.2
1.2
1.4
1.6
1.2
1.4
1.6
1.8
1.6
1.6
1.8
R9
1.6
1.8
2.0
1.8
2.0
R9
2.0
2.0
R10
2.0
R9
R10
R9
R10
R11
R10
R11
R12

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

12

FIXED WIRING AND MAINS CABLES


Stranded plain annealed copper conductors, XLPE insulated, PVC bedding,
galvanised steel wire armour, PVC outer sheath. Black. 1900/3300 volts grade
to BS5467. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
XLPE3X16/3
XLPE3X25/3
XLPE3X35/3
XLPE3X50/3
XLPE3X70/3
XLPE3X95/3
XLPE3X120/3
XLPE3X150/3
XLPE3X185/3
XLPE3X240/3
XLPE3X300/3
XLPE3X400/3

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
16
25
35
50
70
95
120
150
185
240
300
400

7/1.70
7/2.14
7/2.52
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85

NO. OF
CORES
3
3
3
3
3
3
3
3
3
3
3
3

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
1600
29.5
2060
32.3
2330
35.0
3040
34.9
3800
38.0
4730
41.4
6070
45.6
7010
48.3
8270
51.6
10310
56.5
12300
60.7
14780
65.8

GLAND
SIZE
(MM)
32
32
40
40
40
50S
50S
50
50
63S
63
75S

Temperature limits:
-15 to +90C.

Should not be installed at


temperatures below 0C.

Bending radius:
8 x overall diameter.

Current ratings, see page 116.

SINGLE
CLEAT

Core identification:
Brown, Black, Grey.

XLPE INSULATED
MAINS CABLE
3300 VOLT
(16MM2 TO 400MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

1.2
1.4
1.4
1.4
1.6
1.8
1.8
2.0
R9
R9
R10
R11

13

Solid plain aluminium sectoral conductors, XLPE insulated, PVC bedding,


galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to
BS5467. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE

CONDUCTOR
SIZE (MM2)

NO. OF
CORES

WEIGHT
KG/KM

SAC4X25
SAC4X35
SAC4X50
SAC4X70
SAC4X95
SAC4X120
SAC4X150
SAC4X185
SAC4X240
SAC4X300

25
35
50
70
95
120
150
185
240
300

4
4
4
4
4
4
4
4
4
4

1235
1515
1686
2401
2905
3705
4550
5076
6104
7212

OVERALL
DIAMETER
(MM)
25.4
28.9
29.5
34.7
38.3
42.2
46.0
51.1
56.4
61.4

GLAND
SIZE
(MM)
25
32
32
40
40
50S
50
50
63S
63

SINGLE
CLEAT

Temperature limits:
-15 to +90C.

Should not be installed at


temperatures below 0C.

Bending radius:
8 x overall diameter.

Current ratings, see page 114.

Core identification:
Brown, Black, Grey, Blue.

XLPE INSULATED
MAINS CABLE
WITH ALUMINIUM
CONDUCTORS
(25MM2 TO 300MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

1.0
1.2
1.2
1.4
1.6
1.8
2.0
9
9
10

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

14

FIXED WIRING AND MAINS CABLES


Plain annealed stranded compacted circular copper conductor, single core,
XLPE insulated, PVC outer sheath Black. 600/1000 volts grade to BS7889/97.
Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
6181X50
6181X70
6181X95
6181X120
6181X150
6181X185
6181X240
6181X300
6181X400
6181X500
6181X630
6181X800
6181X1000

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
50
70
95
120
150
185
240
300
400
500
630
800
1000

19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
61/3.20
127/2.52
127/2.85
127/3.20

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
540
13.6
750
15.6
1010
17.5
1250
19.2
1530
21.3
1900
23.4
2470
26.3
3080
29.0
3890
32.7
4970
36.6
6370
41.3
8150
46.3
9860
53.0

GLAND
SIZE
(MM)
25
25
25
32
32
32
40
40
50S
50S
50
63S
63

SINGLE
CLEAT

TREFOIL
CLEAT

0.6
0.7
0.7
0.8
0.9
1.0
1.1
1.2
1.4
1.6
1.8
2.0
R9

207
502
504
506
509
511
515
519

Temperature limits:
-15 to +90C.

Should not be installed at


temperatures below 0C.

Bending radius:
8 x overall diameter.

Current ratings, see page 116.

Core identification:
Brown inner / Black outer.

XLPE INSULATED
SINGLE CORE
NON-ARMOURED
MAINS CABLE
(50MM2 TO 1000MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

15

Stranded plain annealed compacted circular copper conductor, XLPE insulated,


PVC bedding, aluminium wire armour, PVC outer sheath. Black. 600/1000 volts
grade to BS5467. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
6941AX50
6941AX70
6941AX95
6941AX120
6941AX150
6941AX185
6941AX240
6941AX300
6941AX400
6941AX500
6941AX630
6941AX800
6941AX1000

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOIL


SIZE (MM2)
(MM)
CORES KG/KM DIAMETER SIZE
CLEAT CLEAT
(MM)
(MM)
50
19/1.78
1
800
17.7
20
0.8
70
19/2.14
1
940
19.6
25
0.9
95
19/2.52
1
1220
21.5
25
1.0
120
37/2.03
1
1490
23.2
25
1.2
150
37/2.25
1
1870
26.3
32
1.2
502
185
37/2.52
1
2290
28.7
32
1.4
504
240
61/2.25
1
2880
31.4
40
1.4
505
300
61/2.52
1
3520
34.1
40
1.8
507
400
61/2.85
1
4520
38.9
50S
1.8
510
500
61/3.20
1
5680
42.8
50S
1.8
512
630
127/2.52
1
7120
47.3
50
2.0
515
800
127/2.85
1
9220
53.9
63S
R9
519
1000
127/3.20
1
11270
58.8
63S
R10
523

Temperature limits:
-15 to +90C.

Should not be installed at


temperatures below 0C.

Bending radius:
6 x overall diameter.

Current ratings, see page 111.

Core identification:
Brown inner / Black outer.

XLPE INSULATED
SINGLE CORE ARMOURED
MAINS CABLE
(50MM2 TO 1000MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

16

FIXED WIRING AND MAINS CABLES


Plain annealed compacted circular copper conductor, XLPE insulated, PVC
outer sheath, 600/1000 volts grade generally to BS5467 & IEC 502/1. Colours
Black/Black or Red/Red.
CCC
CODE

CONDUCTOR
SIZE (MM2)

STRANDING
(MM)

WEIGHT
KG/KM

6181X6
6181X10
6181X16
6181X25
6181X35
6181X50
6181X70
6181X95
6181X120
6181X150
6181X185

6
10
16
25
35
50
70
95
120
150
185

7/1.04
7/1.35
7/1.70
7/2.14
7/2.52
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52

105
150
210
305
395
515
725
1230
1355
1695
2110

Bending radius:
4 x overall diameter.

XLPE INSULATED NONARMOURED AND


ARMOURED SINGLE CORE
CABLE FOR CATHODIC
PROTECTION
(6MM2 TO 185MM2)

OVERALL
DIAMETER
(MM)
7.2
8.1
9.0
10.6
11.6
13.0
14.9
17.5
19.2
21.3
23.4

GLAND
SIZE
(MM)
20/16
20/16
20S
20S
20
20
25
25
32
32
32

Should not be installed at


temperatures below 0C.

Plain annealed compacted circular copper conductor, XLPE insulated, PVC


bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000
volts grade generally to IEC 502/1 & BS5467.
CCC
CODE

CONDUCTOR
SIZE (MM2)

STRANDING
(MM)

WEIGHT
KG/KM

6941X6
6941X10
6941X16
6941X25
6941X35
6941X50
6941X70
6941X95
6941X120
6941X150
6941X185

6
10
16
25
35
50
70
95
120
150
185

7/1.04
7/1.35
7/1.70
7/2.14
7/2.52
19/1.17
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52

285
355
435
585
685
835
1080
1375
1685
2120
2505

Bending radius:
4 x overall diameter.

OVERALL
DIAMETER
(MM)
11.5
12.5
13.5
15.0
16.0
17.5
19.5
21.6
23.4
26.4
28.9

GLAND
SIZE
(MM)
20/16
20/16
20S
20S
20
20
20
25
25
25
32

Should not be installed at


temperatures below 0C.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

17

Stranded plain annealed compacted circular copper conductor, low smoke and
zero halogen (LSOH) outer sheath. 450/750 volts grade to BS7211. Flame
propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE

CONDUCTOR
SIZE (MM2)

STRANDING
(MM)

WEIGHT
KG/KM

6491B1/5
6491B2/5
6491B4
6491B6
6491B10
6491B16
6491B25
6491B35
6491B50
6491B70
6491B95
6491B120
6491B150
6491B185
6491B240
6491B300
6491B400
6491B500
6491B630

1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0

7/0.53
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
61/3.20
127/2.50

22
33
49
69
116
175
273
367
510
715
990
1230
1510
1900
2490
3050
3842
4900
6334

OVERALL
DIAMETER
(MM)
3.5
4.2
4.8
5.4
6.8
8.0
9.8
11.0
11.8
13.6
15.9
17.5
19.4
21.7
24.5
27.5
28.5
32.0
38.2

Temperature limits:
-15 to +70C.

Should not be installed at


temperatures below 0C.

Bending radius:
up to 10mm2 - 3 x overall diameter
above 25mm2 - 6 x overall diameter

Current ratings, see page 110.


Brass A2 gland size only.

Standard colours available:


1.5mm2 & 2.5mm2 - Brown, Black,
Grey, Blue, Green/Yellow, White,
Orange, Turquoise, Violet, Pink.

LOW SMOKE ZERO


HALOGEN INSULATED
WIRING CABLE 6491B
(1.5MM2 TO 630MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

18

FIXED WIRING AND MAINS CABLES


Plain annealed stranded copper conductors, XLPE insulated, low smoke and
zero halogen (LSOH) bedding, galvanised steel wire armour, low smoke and
zero halogen (LSOH) outer sheath. Black. 600/1000 volts grade to BS6724.
Flame propagation to BS4066 PT1 and IEC 332 PT1.
(Bunched cables to BS4066 PT3 and IEC 332 PT3).
CCC
CODE
LSF2X1/5
LSF3X1/5
LSF4X1/5
LSF5X1/5
LSF7X1/5
LSF12X1/5
LSF19X1/5
LSF27X1/5
LSF37X1/5
LSF48X1/5
LSF2X2/5
LSF3X2/5
LSF4X2/5
LSF5X2/5
LSF7X2/5
LSF12X2/5
LSF19X2/5
LSF27X2/5
LSF37X2/5
LSF48X2/5
LSF2X4
LSF3X4
LSF4X4
LSF5X4
LSF7X4
LSF12X4
LSF27X4
LSF2X6
LSF3X6
LSF4X6
LSF5X6
LSF7X6
LSF2X10
LSF3X10
LSF4X10
LSF5X10
LSF7X10
LSF2X16
LSF3X16
LSF4X16
LSF5X16
LSF7X16

XLPE INSULATED
LOW SMOKE ZERO
HALOGEN MAINS AND
CONTROL CABLE
(1.5MM2 TO 16MM2)

CONDUCTOR STRANDING
(MM)
SIZE (MM2)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0
6.0
10.0
10.0
10.0
10.0
10.0
16.0
16.0
16.0
16.0
16.0

7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/1.04
7/1.04
7/1.04
7/1.04
7/1.04
7/1.35
7/1.35
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/1.70
7/1.70
7/1.70

NO. OF
CORES
2
3
4
5
7
12
19
27
37
48
2
3
4
5
7
12
19
27
37
48
2
3
4
5
7
12
27
2
3
4
5
7
2
3
4
5
7
2
3
4
5
7

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
310
12.5
340
13.0
390
14.0
426
14.2
490
15.9
830
20.2
1070
23.2
1580
27.9
1880
30.6
2236
32.2
360
13.6
410
14.1
470
15.0
549
16.3
600
17.1
1020
22.4
1530
26.6
1960
30.7
2370
33.8
3888
38.8
430
14.7
500
15.3
580
16.4
810
18.9
950
20.4
1400
25.0
2630
35.2
500
15.9
770
16.6
820
18.7
970
20.5
1180
21.9
800
18.0
900
19.5
1060
21.1
1131
22.0
1560
25.0
940
20.0
1180
21.2
1410
22.9
1880
26.2
2237
28.1

GLAND
SIZE
(MM)
20/16
20S
20S
20
20
20
25
32
32
32
20S
20S
20S
20
20
25
25
32
40
40
20S
20S
20
20
20
25
40
20
20
20
25
25
20
25
25
25
25
20
25
25
25
32

SINGLE
CLEAT
0.5
0.6
0.6
0.6
0.7
0.8
1.0
1.2
1.4
1.4
0.6
0.6
0.6
0.7
0.7
0.9
1.1
1.4
1.4
1.6
0.6
0.7
0.7
0.8
0.9
1.0
1.4
0.7
0.7
0.8
0.9
0.9
0.8
0.8
0.9
0.9
1.0
0.8
0.9
1.0
1.1
1.2

Temperature limits:
to +90C.

1.5 & 2.5 - 2,3,4 core also available in


white numbered cores to ESI 09-6

Bending radius:
6 x overall diameter.

Should not be installed at


temperatures below 0C.

Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
5 core and above - Up to 6mm2 White with Black numbers.
5 core and above - 10mm2 and
16mm2 - Brown, Black, Grey, Blue,
Green/Yellow.

Current ratings, see page 112.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

19

Stranded plain annealed copper conductors, XLPE insulated, low smoke and
zero halogen (LSOH) extruded bedding, galvanised steel wire armour, low
smoke and zero halogen (LSOH) outer sheath. Black. 600/1000 volts grade to
BS6724. Flame propagation to BS4066 PT1 and IEC 332 PT1.
(Bunched cables to BS4066 PT3 and IEC 332 PT3).

CCC
CODE
LSF2X25
LSF3X25
LSF4X25
LSF5X25
LSF2X35
LSF3X35
LSF4X35
LSF5X35
LSF2X50
LSF3X50
LSF4X50
LSF5X50
LSF2X70
LSF3X70
LSF4X70
LSF5X70
LSF2X95
LSF3X95
LSF4X95
LSF5X95
LSF2X120
LSF3X120
LSF4X120
LSF5X120
LSF2X150
LSF3X150
LSF4X150
LSF2X185
LSF3X185
LSF4X185
LSF2X240
LSF3X240
LSF4X240
LSF2X300
LSF3X300
LSF4X300
LSF3X400
LSF4X400

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
25
25
25
25
35
35
35
35
50
50
50
50
70
70
70
70
95
95
95
95
120
120
120
120
150
150
150
185
185
185
240
240
240
300
300
300
400
400

7/2.14
7/2.14
7/2.14
7/2.14
7/2.52
7/2.52
7/2.52
7/2.52
19/1.78
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
19/2.14
19/2.52
19/2.52
19/2.52
19/2.52
37/2.03
37/2.03
37/2.03
37/2.03
37/2.25
37/2.25
37/2.25
37/2.52
37/2.52
37/2.52
61/2.25
61/2.25
61/2.25
61/2.52
61/2.52
61/2.52
61/2.85
61/2.85

NO. OF
CORES
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
2
3
4
2
3
4
2
3
4
3
4

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
1250
24.3
1720
26.9
2090
29.1
2370
31.0
1720
27.9
2130
29.6
2590
32.1
3150
35.0
1800
25.3
2380
28.4
2960
31.3
4260
40.0
2330
28.1
3150
32.0
4240
36.8
5685
43.0
3170
31.9
4320
36.7
5410
40.6
7700
52.0
3810
35.1
5200
40.0
6980
45.8
9030
56.7
4530
38.2
6630
45.1
8320
49.9
5860
43.3
7980
49.3
10080
54.9
7300
48.3
9960
54.5
61.0
12690
8790
52.5
12060
59.5
15420
66.5
15330
68.0
20215
77.5

GLAND
SIZE
(MM)
25
32
32
32
32
32
32
40
32
32
32
50S
40
32
40
50S
32
40
50S
50
40
50S
50
63S
40
50S
50
50S
50
63S
50
63S
63
63S
63
75S
75S
75

Temperature limits:
-25 to +90C.

Should not be installed at


temperatures below 0C.

Bending radius:
8 x overall diameter.

Current ratings, see page 112.

SINGLE
CLEAT

Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
5 core - Brown, Black, Grey, Blue,
Green/Yellow.

XLPE INSULATED
LOW SMOKE ZERO
HALOGEN MAINS CABLE
(25MM2 TO 400MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

1.2
1.2
1.2
1.4
1.2
1.2
1.4
1.4
1.2
1.2
1.4
1.6
1.2
1.4
1.6
1.8
1.6
1.6
1.8
R9
1.6
1.8
2.0
R9
1.8
2.0
R9
2.0
2.0
R9
2.0
R9
R10
R9
R10
R11
R11
R12M

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

20

FIXED WIRING AND MAINS CABLES


Plain annealed stranded compacted circular copper conductor, single core,
XLPE insulated, low smoke and zero halogen (LSOH) outer sheath. Black.
600/1000 volts grade to BS6724.
Flame propagation to BS4066 PT1 and IEC 332 PT1.
(Bunched cables to BS4066 PT3 and IEC PT3).
CCC
CODE
6181B50
6181B70
6181B95
6181B120
6181B150
6181B185
6181B240
6181B300
6181B400
6181B500
6181B630
6181B800
6181B1000

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
50
70
95
120
150
185
240
300
400
500
630
800
1000

19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.52
61/3.20
127/2.52
127/2.85
127/3.20

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
540
13.6
750
15.6
1010
17.5
1250
19.2
1530
21.3
1900
23.4
2470
26.3
3080
29.0
3890
32.7
4970
36.6
6370
41.3
8150
46.3
9860
53.00

GLAND
SIZE
(MM)
25
25
25
32
32
32
40
40
50S
50S
50
63S
63

SINGLE
CLEAT

TREFOIL
CLEAT

0.6
0.7
0.7
0.8
0.9
1.0
1.1
1.2
1.4
1.6
1.8
2.0
R9

207
502
504
506
509
511
515
519

Temperature limits:
-25 to +90C.

Should not be installed at


temperatures below 0C.

Bending radius:
6 x overall diameter.

Current ratings, see page 116.

Core identification:
Brown inner/Black outer.

XLPE INSULATED
LOW SMOKE ZERO
HALOGEN SINGLE CORE
NON-ARMOURED
MAINS CABLE
1000 VOLT
(50MM2 TO 1000MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

21

Stranded plain annealed compacted circular copper conductor, XLPE insulated,


low smoke and zero halogen (LSOH) extruded bedding, aluminium wire
armour, low smoke and zero halogen (LSOH) outer sheath. Black. 600/1000
volts grade to BS6724. Flame propagation to BS4066 PT1 and IEC 332 PT1.
(Bunched cables to BS4066 PT3 and IEC 332 PT3).
CCC
CODE
6941AB50
6941AB70
6941AB95
6941AB120
6941AB150
6941AB185
6941AB240
6941AB300
6941AB400
6941AB500
6941AB630
6941AB800
6941AB1000

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOIL


(MM)
CORES KG/KM DIAMETER SIZE
CLEAT CLEAT
SIZE (MM2)
(MM)
(MM)
50
19/1.78
1
800
17.7
20
0.8
70
19/2.14
1
940
19.6
25
0.9
95
19/2.52
1
1220
21.5
25
1.0
120
37/2.03
1
1490
23.2
25
1.2
150
37/2.25
1
1870
26.3
32
1.2
502
185
37/2.52
1
2290
28.7
32
1.4
504
240
61/2.25
1
2880
31.4
40
1.4
505
300
61/2.52
1
3520
34.1
40
1.8
507
400
61/2.85
1
4520
38.9
50S
1.8
510
500
61/3.20
1
5680
42.8
50S
1.8
512
630
127/2.52
1
7120
47.3
50
2.0
515
800
127/2.85
1
9220
53.9
63S
R9
519
1000
127/3.20
1
11270
58.8
635
R10
523

Temperature limits:
-25 to +90C.

Should not be installed at


temperatures below 0C.

Bending radius:
6 x overall diameter.

Current ratings, see page 111.

Core identification:
Brown inner/Black outer.

XLPE INSULATED
LOW SMOKE ZERO
HALOGEN SINGLE CORE
ARMOURED MAINS CABLE
(50MM2 TO 1000MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

22

SCREENED FIXED WIRING AND MAINS CABLES TO BS 8436


Plain annealed stranded copper, XLPE insulated, tinned annealed stranded
copper earth wire, bonded aluminium tube applied longitudinally low smoke
and zero halogen (LSOH) outer sheath, to BS EN 50267-1:1998 and BS EN
50268-2:2000, UV Stable. 300/500v to BS8436, White.
CCC
CODE
FSX2X1WH
FSX3X1WH
FSX4X1WH
FSX2X1/5WH
FSX3X1/5WH
FSX4X1/5WH
FSX2X2/5WH
FSX3X2/5WH
FSX4X2/5WH
FSX2X4WH
FSX3X4WH
FSX4X4WH
FSX2X6WH
FSX3X6WH
FSX4X6WH

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND 1 HOLE GLAND


SIZE (MM2)
(MM)
CORES KG/KM DIAMETER SIZE
CLIP
REF
(MM)
(MM)
REF
1.0
7/0.44
2
85
8.60
20S
RCHL20 20SA2
1.0
7/0.44
3
105
9.40
20S
RCHL20 20SA2
1.0
7/0.44
4
130
10.00
20
RCHL20 20A2
1.5
7/0.53
2
106
9.80
20
RCHL20 20A2
1.5
7/0.53
3
140
10.40
20
RCHL20 20A2
1.5
7/0.53
4
158
11.30
20
RCHL20 20A2
2.5
7/0.67
2
135
10.80
20
RCHL20 20A2
2.5
7/0.67
3
182
11.10
20
RCHL20 20A2
2.5
7/0.67
4
259
12.60
20
RCHL20 20A2
4
7/0.85
2
206
11.50
20
RCHL20 20A2
4
7/0.85
3
265
13.10
25
RCHL25 25A2
4
7/0.85
4
320
13.90
25
RCHL25 25A2
6
7/1.04
2
258
13.10
25
RCHL25 25A2
6
7/1.04
3
328
14.20
25
RCHL25 25A2
6
7/1.04
4
450
14.90
25
RCHL25 25A2

Minimum installation temperature:


-10C.
Maximum continuous conductors
operating temperature:
+90C.

*Solid cores available on request.


Different sheath and core colours
available on request.
10mm2 and 16mm2 available
on request

Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.

MECHANICALLY
PROTECTED
WIRING CABLE
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

23

Stranded plain annealed circular compacted copper conductors, XLPE


insulated, semi-conducting tape insulated, each core copper tape screened,
PVC bedding, galvanised steel wire armour, PVC outer sheath - Red.
6350/11000 volts grade to BS6622 and IEC 502/1. Flame retardant to BS 4066
PT1 and IEC 332 PT1.
CCC
CODE

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE RAYCHEM


(MM)
CORES KG/KM DIAMETER SIZE CLEAT TERMINATION
SIZE (MM2)
(MM)
(MM)
REFERENCE
11KV XLPE3X25RD
25
7/2/14
3
4400
48.8
50
2.0 EPKT 17A3XIH2
11KV XLPE3X35RD
35
19/1/53
3
4900
51.6
50
R9 EPKT 17B3XIH2
11KV XLPE3X50RD
50
19/1/78
3
5600
54.6
63S
R9 EPKT 17B3XIH2
11KV XLPE3X70RD
70
19/2/14
3
6500
58.5
63S
R10 EPKT 17B3XIH2
11KV XLPE3X95RD
95
19/2/52
3
7800
62.6
63
R10 EPKT 17C3XIH2
11KV XLPE3X120RD
120
37/2/03
3
8900
66.6
75S
R11 EPKT 17C3XIH2
11KV XLPE3X150RD
150
37/2/25
3
10000
68.8
75S
R11 EPKT 17C3XIH2
11KV XLPE3X185RD
185
37/2/52
3
11600
74.1
75
R12 EPKT 17C3XIH2
11KV XLPE3X240RD
240
61/2/25
3
14800
81.2
90
R14 EPKT 17C3XIH2
11KV XLPE3X300RD
300
61/2/52
3
17300
86.8
90
R15 EPKT 1D3XIH2
11KV XLPE3X400RD
400
61/2/85
3
19300
93.0
R15 EPKT 17D3XIH2

Temperature limits:
up to 90C.

Should not be installed at


temperatures below 0C.

Bending radius:
12 x overall diameter.

Current ratings, see page 119.

Core identification:
Brown, Black, Grey tapes.

3 CORE
XLPE INSULATED
MEDIUM VOLTAGE
MAINS CABLE 11000 VOLT
(25MM2 TO 400MM2)
AND SINGLE CORE
(50MM2 TO 630MM2)

Stranded plain annealed circular compacted copper conductors, XLPE


insulated, semi-conducting tape insulated, copper tape screen, PVC bedding,
aluminium wire armour, PVC outer sheath - Red. 6350/11000 volts grade to
BS6622 and IEC 502/1.
Flame retardant to BS4066 PT1 and IEC 332 PT1.
CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOIL RAYCHEM
CODE SIZE (MM2) (MM)
CORES KG/KM DIAMETER SIZE CLEAT CLEAT TERMINATION
(MM)
(MM)
REFERENCE
10001
50
19/1.78
1
1200
28.0
32
1.2 503/504 EPKT 17B1XI
10002
70
19/2.14
1
1500
29.9
32
1.2
504
EPKT 17B1XI
10003
95
19/2.52
1
1600
31.7
32
1.4
506 EPKT 17C1XI
10004
120
37/2.03
1
2100
33.3
40
1.4
506 EPKT 17C1XI
37/2.25
1
2500
35.7
40
1.6 508/509 EPKT 17C1XI
150
10005
10006
185
37/2.52
1
2900
37.5
40
1.6 508/509 EPKT 17C1XI
10007
240
61/2.25
1
3600
40.1
50S
1.6 510/511 EPKT 17C1XI
50S
1.8 512/513 EPKT 17D1XI
42.4
4300
1
61/2.52
300
10008
10009
400
61/2.85
1
5200
45.8
50S
2.0
514 EPKT 17D1XI
10010
500
61/3.20
1
6500
50.5
50
2.0 516/517 EPKT 17E1XI
10011
630
127/2.52
1
8000
54.7
63S
R9 519/521 EPKT 17E1XI

Temperature limits:
up to 90C.

Should not be installed at


temperatures below 0C.

Bending radius:
12 x overall diameter.

Current ratings, see page 118.

Core identification:
Brown.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

24

FIXED WIRING AND MAINS CABLES


Plain stranded aluminium conductors, XLPE insulated, semi-conducting tape
insulated, each core copper tape screened, PVC bedding (extruded), galvanised
steel wire armour, PVC outer sheath.
Red. 6350/11000 volts grade to BS6622 and IEC 502/1. Flame propagation to
BS4066 PT1 and IEC 332 PT1
CCC
CODE
10115RD
10116RD
10117RD
10118RD
10119RD
10120RD

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE


(MM)
CORES KG/KM DIAMETER SIZE CLEAT
SIZE (MM2)
(MM)
(MM)
95
19/2.52
3
5800
62.6
63
R10
120
37/2.03
3
6400
66.6
75S
R11
150
37/2.25
3
7000
68.6
75S
R11
185
37/2.52
3
7800
74.1
75
R12
240
61/2.25
3
9800
81.2
90
R14
300
61/2.52
3
11000
86.8
90
R15

RAYCHEM
TERMINATION
REFERENCE
EPKT 17C3XIH2
EPKT 17C3XIH2
EPKT 17C3XIH2
EPKT 17C3XIH2
EPKT 17C3XIH2
EPKT 17D3XIH2

Temperature limits:
up to 90C.

Should not be installed at


temperatures below 0C.

Bending radius:
13 x overall diameter.

Current ratings see page 120.

Core identification:
Brown, Black, Grey tapes.

XLPE INSULATED
MEDIUM VOLTAGE
MAINS CABLE
11000 VOLT
(95MM2 TO 300MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

25

Stranded plain annealed compacted circular copper conductors, XLPE


insulated, semi-conducting tape insulated, each core copper tape screened,
low smoke and zero halogen (LSOH) bedding, galvanised steel wire armour,
low smoke and zero halogen (LSOH) outer sheath - Red. 6350/11000 volts
grade to BS7835. Flame retardant to BS4066 PT1 and IEC 332 PT1.
(Bunched cables to BS4066 PT3 and IEC 332 PT3).
CCC
CODE
10302RD
10304RD
10306RD
10308RD
10310RD
10312RD
10314RD
10316RD
10318RD

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE


SIZE (MM2)
(MM)
CORES KG/KM DIAMETER SIZE CLEAT
(MM)
(MM)
35
19/1.53
3
4900
51.6
50
R9
50
19/1.78
3
5600
54.6
63S
R9
70
19/2.14
3
6500
58.5
63S
R10
95
19/2.52
3
7800
62.6
63
R10
120
37/2.03
3
8900
66.6
75S
R11
150
37/2.25
3
10000
68.8
75
R11
185
37/2.52
3
11600
74.1
75
R12
240
61/2.25
3
14800
81.2
90
R14
300
61/2.52
3
17300
86.8
90
R15

RAYCHEM
TERMINATION
REFERENCE
EPKT 17B3XIH2
EPKT 17B3XIH2
EPKT 17B3XIH2
EPKT 17C3XIH2
EPKT 17C3XIH2
EPKT 17C3XIH2
EPKT 17C3XIH2
EPKT 17C3XIH2
EPKT 17D3XIH2

Temperature limits:
up to 90C.

Should not be installed at


temperatures below 0C.

Bending radius:
12 x overall diameter.

Current ratings, see page 119.

Core identification:
Brown, Black, Grey tapes.

3 CORE
XLPE INSULATED LOW
SMOKE ZERO HALOGEN
MEDIUM VOLTAGE
MAINS CABLE 11000 VOLT
(35MM2 TO 300MM2)
AND SINGLE CORE
(50MM2 TO 630MM2)

Stranded plain annealed compacted circular copper conductor, XLPE insulated,


semi-conducting tape insulated, copper tape screen, low smoke and zero
halogen (LSOH) bedding, aluminium wire armour, low smoke and zero
halogen (LSOH) outer sheath - Red. 6350/11000 volts grade to BS7835. Flame
retardant to BS4066 PT1 and IEC 332 PT1.
(Bunched cables to BS4066 PT3 and IEC 332 PT3).
CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOIL RAYCHEM
CODE SIZE (MM2) (MM)
CORES KG/KM DIAMETER SIZE CLEAT CLEAT TERMINATION
(MM)
(MM)
REFERENCE
10050
50
19/1.78
1
1200
28.8
32
1.2
504
EPKT 17B1XI
10051
70
19/2.14
1
1500
29.9
32
1.2
504
EPKT 17B1XI
19/2.52
1
1600
31.7
32
1.4
505 EPKT 17C1XI
95
10052
10053
120
37/2.03
1
2100
33.3
40
1.4
506 EPKT 17C1XI
10054
150
37/2.25
1
2500
35.7
40
1.6
508 EPKT 17C1XI
40
1.6
509 EPKT 17C1XI
37.5
2900
1
37/2.52
185
10055
10056
240
61/2.25
1
3600
40.1
50S
1.6
511 EPKT 17C1XI
10057
300
61/2.52
1
4300
42.4
50S
1.8
512 EPKT 17D1XI
10058
400
61/2.85
1
5200
45.8
50S
2.0
514 EPKT 17D1XI
10059
500
61X3.20
1
6500
50.5
50
2.0
517
EPKT 17E1XI
10060
630
127X2.52
1
8000
54.7
63S
R9
520
EPKT 17E1XI

Temperature limits:
up to 90C.

Should not be installed at


temperatures below 0C.

Bending radius:
15 x overall diameter.

Current ratings, see page 118.

Core identification:
Brown.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

26

FIXED WIRING AND MAINS CABLES


Plain annealed copper conductors, paper insulated, paper belted, semiconducting carbon paper tape bedding, lead sheathed, textile compound
bedding, galvanised steel wire armour, PVC outer sheath - Red. 6350/11000
volts grade to BS6480/88. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
PILC3X25RD
PILC3X35RD
PILC3X50RD
PILC3X70RD
PILC3X95RD
PILC3X120RD
PILC3X150RD
PILC3X185RD
PILC3X240RD
PILC3X300RD
PILC3X400RD

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
25
35
50
70
95
120
150
185
240
300
400

7/2.14
19/1.53
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85

No. OF
CORES
3
3
3
3
3
3
3
3
3
3
3

Temperature limits:
up to 65C.

WEIGHT OVERALL SINGLE RAYCHEM


KG/KM DIAMETER CLEAT TERMINATION
(MM)
REFERENCE
5230
43.6
1.8 EPKT 17A3MIH2
5890
42.3
2.0 EPKT 17B3MIH2
6620
45.6
2.0 EPKT 17B3MIH2
7820
49.7
2.0 EPKT 17B3MIH2
9240
53.3
R9 EPKT 17C3MIH2
10400
56.2
R9 EPKT 17C3MIH2
11770
59.2
R10 EPKT 17C3MIH2
13550
62.8
R10 EPKT 17C3MIH2
16390
67.8
R11 EPKT 17C3MIH2
19870
73.6
R12 EPKT 17D3MIH2
23700
79.4
R14 EPKT 17D3MIH2

Should not be installed at


temperatures below 0C.

Bending radius:
13 x overall diameter.

PAPER INSULATED
MEDIUM VOLTAGE
MAINS CABLE
11000 VOLT
(25MM2 TO 400MM2)

Core identification:
White printed numbers on
insulating papers.
Plain aluminium stranded conductors, paper insulated, paper belted, semiconducting carbon paper tape bedding, lead sheathed, textile compound
bedding, galvanised steel wire armour, PVC outer sheath - Red. 6350/11000
volts grade to BS6480/88. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
10100RD
10103RD
10105RD

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
95
185
300

Temperature limits:
up to 65C.
Bending radius:
13 x overall diameter.

19/2.52
37/2.52
61/2.52

No. OF
CORES
3
3
3

WEIGHT OVERALL SINGLE RAYCHEM


KG/KM DIAMETER CLEAT TERMINATION
(MM)
REFERENCE
7115
53.2
R9 EPKT 17C3MIH2
9521
63.5
R11 EPKT 17C3MIH2
13403
71.5
R12 EPKT 17D3MIH2

Core identification:
White printed numbers on
insulating papers.
Should not be installed at
temperatures below 0C.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

27

Stranded aluminium conductors, paper insulated, (mass impregnated, nondraining type), carbon paper tape belted, corrugated aluminium sheathed, PVC
outer sheath. Red. 6350/11000 volts grade to ESI 09-12.
CCC
CODE
PICAS3X95
PICAS3X120
PICAS3X150
PICAS3X185
PICAS3X240
PICAS3X300

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
95
120
150
185
240
300

Temperature limits:
up to 65C.
Bending radius:
13 x overall diameter.

19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52

No. OF
CORES
3
3
3
3
3
3

WEIGHT OVERALL SINGLE RAYCHEM


KG/KM DIAMETER CLEAT TERMINATION
(MM)
REFERENCE
3400
49.0
2.0 EPKT 17C3MIH2
4000
53.2
R9 EPKT 17C3MIH2
4500
56.6
R9 EPKT 17C3MIH2
5200
60.7
R10 EPKT 17C3MIH2
6400
66.8
R11 EPKT 17D3MIH2
7500
72.5
R12 EPKT 17D3MIH2

Core identification:
White numbers printed on
insulating papers.
Should not be installed at
temperatures below 0C.

PAPER INSULATED
CORRUGATED
ALUMINIUM SHEATHED
MEDIUM VOLTAGE
MAINS CABLE
11000 VOLT
(95MM2 TO 300MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

28

FIXED WIRING AND MAINS CABLES


Plain annealed stranded copper conductors, XLPE insulated, PVC extruded
bedding, galvanised steel wire armour incorporating tinned copper wires to
provide 60% conductivity of any one phase, PVC outer sheath. Black. 600/1000
volts grade generally to BS5467 and BC295.
Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
NCB3X10/1
NCB4X10/1
NCB3X16/1
NCB4X16/1
NCB3X25
NCB4X25
NCB3X35
NCB4X35
NCB3X50
NCB4X50
NCB3X70
NCB4X70
NCB3X95
NCB4X95
NCB3X120
NCB4X120
NCB3X150
NCB4X150
NCB3X185
NCB4X185
NCB3X240
NCB4X240
NCB3X300
NCB4X300

CONDUCTOR STRANDING
(MM)
SIZE (MM2)
10
10
16
16
25
25
35
35
50
50
70
70
95
95
120
120
150
150
185
185
240
240
300
300

7/1.04
7/1.04
7/1.70
7/1.70
7/2.14
7/2.14
7/2.52
7/2.52
19/1.78
19/1.78
19/2.14
19/2.14
19/2.52
19/2.52
37/2.03
37/2.03
37/2.25
37/2.25
37/2.52
37/2.52
61/2.25
61/2.25
61/2.52
61/2.52

NO. OF
CORES
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4

Temperature limits:
-15 to +70C.

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
896
18.9
1038
20.3
1205
23.1
1675
26.3
1550
26.9
1880
29.1
1940
29.6
2350
32.1
2360
28.4
2950
31.3
3120
32.0
4230
36.8
4310
36.7
5390
40.6
5160
40.0
6980
45.8
6610
45.1
8300
49.9
7920
49.3
10070
54.9
9930
54.5
12680
61.0
11970
59.5
15380
66.5

GLAND
SIZE
(MM)
20
20
25
25
25
32
32
32
32
32
32
40
40
50S
50S
50S
50S
50
50
63S
63S
63
63
75S

SINGLE
CLEAT
0.8
0.8
1.0
1.1
1.1
1.2
1.2
1.4
1.2
1.4
1.4
1.6
1.6
1.6
1.6
2.0
1.8
2.0
2.0
R9
R9
R10
R10
R11

Core identification:
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.

Bending radius:
up to 16mm2 - 6 x overall diameter.
over 16mm2 - 8 x overall diameter.

Should not be installed at


temperatures below 0C.
Current ratings, see page 112.

Plain annealed stranded copper conductors, XLPE insulated, PVC extruded


bedding, galvanised steel wire armour incorporating tinned copper wires to
provide 60% conductivity of any one phase, PVC outer sheath. Black.
1900/3300 volts grade generally to BS5467 and BC295.
Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE

XLPE INSULATED MAINS


CABLE WITH 60%
CONDUCTIVITY
IN ARMOUR.
(MINES & QUARRIES &
BRITISH COAL)
(10MM2 TO 300MM2)

NCB3X16/3
NCB3X25/3
NCB3X35/3
NCB3X50/3
NCB3X70/3
NCB3X95/3
NCB3X120/3
NCB3X150/3
NCB3X185/3
NCB3X240/3
NCB3X300/3

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
16
25
35
50
70
95
120
150
185
240
300

7/1.70
19/1.35
19/1.53
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.25

NO. OF
CORES
3
3
3
3
3
3
3
3
3
3
3

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
1600
29.5
2060
32.3
2330
35.0
3040
34.9
3800
38.0
4730
41.4
45.6
6070
7010
48.3
8270
51.6
10310
56.5
12300
60.7

GLAND
SIZE
(MM)
32
32
40
40
40
50S
50S
50
50
63S
63

Temperature limits:
-15 to +90C.

Core identification:
Brown, Black, Grey.

Bending radius:
up to 16mm2 - 6 x overall diameter.
over 25mm2 - 8 x overall diameter.

Should not be installed at


temperatures below 0C.

SINGLE
CLEAT

Current ratings, see page 112.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

1.2
1.4
1.4
1.4
1.6
1.8
1.8
2.0
R9
R9
R10

29

Plain annealed stranded copper conductors, XLPE insulated, lead sheathed,


PVC bedding, galvanised steel wire armour, PVC outer sheath. Cores White
with Black numbers. 600/1000 volts grade to BS5467 and EEMUA 133.
Flame propogation to BS 4066 PT1 and IEC 332 PT1.
CCC
CODE
EEMUA2X1/5 ESI
EEMUA3X1/5 ESI
EEMUA4X1/5 ESI
EEMUA5X1/5
EEMUA7X1/5
EEMUA12X1/5
EEMUA19X1/5
EEMUA27X1/5
EEMUA37X1/5
EEMUA2X2/5ESI
EEMUA3X2/5ESI
EEMUA4X2/5ESI
EEMUA5X2/5
EEMUA7X2/5
EEMUA12X2/5
EEMUA19X2/5
EEMUA27X2/5
EEMUA37X2/5
EEMUA5X4
EEMUA7X4

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0

7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85

NO. OF
CORES
2
3
4
5
7
12
19
27
37
2
3
4
5
7
12
19
27
37
5
7

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
566
15.3
593
15.8
813
16.64
695
16.8
1072
17.7
1387
22.3
1686
24.8
2418
30.0
2850
32.7
772
16.68
842
17.21
934
18.28
1038
18.4
1324
20.02
1750
25.19
2489
29.9
3248
34.17
3840
42.81
1014
20.6
1110
21.5

GLAND
SIZE
(MM)
20S
20
20
20
20
25
25
32
40
20
20
25
20
25
32
32
40
50S
25
25

SINGLE
CLEAT

Temperature limits:
-15 to +90C.
Bending radius:
12 x overall diameter.
Core identification:
White with Black numbers.

XLPE INSULATED LEAD


SHEATHED CONTROL
CABLE FOR
PETRO-CHEMICAL
INDUSTRIES
(1.5MM2 TO 4MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

0.6
0.6
0.7
0.7
0.8
0.9
1.0
1.2
1.4
0.7
0.7
0.7
0.8
0.9
1.0
1.2
1.4
1.6
0.9
0.9

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

30

FIXED WIRING AND MAINS CABLES


Plain annealed stranded copper conductors, XLPE insulated, lead sheathed,
PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000
volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flame
propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
EEMUA2X25
EEMUA3X25
EEMUA4X25
EEMUA2X35
EEMUA3X35
EEMUA4X35
EEMUA2X50
EEMUA3X50
EEMUA4X50
EEMUA2X70
EEMUA3X70
EEMUA4X70
EEMUA2X95
EEMUA3X95
EEMUA4X95
EEMUA2X120
EEMUA3X120
EEMUA4X120
EEMUA2X150
EEMUA3X150
EEMUA4X150
EEMUA2X185
EEMUA3X185
EEMUA4X185
EEMUA2X240
EEMUA3X240
EEMUA4X240
EEMUA2X300
EEMUA3X300
EEMUA4X300

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
25
25
25
35
35
35
50
50
50
70
70
70
95
95
95
120
120
120
150
150
150
185
185
185
240
240
240
300
300
300

7/2.14
7/2.14
7/2.14
19/1.53
19/1.53
19/1.53
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
19/2.52
19/2.52
19/2.52
37/2.03
37/2.03
37/2.03
37/2.25
37/2.25
37/2.25
37/2.52
37/2.52
37/2.52
61/2.25
61/2.25
61/2.25
61/2.52
61/2.52
61/2.52

NO. OF
CORES
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
2094
27.5
2673
30.5
3204
32.5
2868
27.5
3338
31.0
4043
33.5
2783
28.1
3572
34
4456
37.5
3566
31.1
4639
37.5
6160
43.5
4678
35.1
6023
43
7592
47.5
5641
38.5
7392
46.5
9802
53
6660
41.8
9242
52.5
11757
58
8457
47.1
11054
56.5
14117
63
10286
52.3
13792
55.9
17700
65.8
12245
56.7
16519
64.1
21173
71.5

GLAND
SIZE
(MM)
32
32
40
32
32
40
32
40
40
32
40
50S
40
50S
50
50S
50S
63S
50S
50
63S
50
63S
63
63S
63S
75S
63S
63
75S

SINGLE
CLEAT

Temperature limits:
-15 to +90C.
Bending radius:
12 x overall diameter.
Core identification:
2 core - Brown, Blue
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
Should not be installed at
temperatures below 0C.

XLPE INSULATED
LEAD SHEATHED MAINS
CABLE FOR
PETRO-CHEMICAL
INDUSTRIES
(25MM2 TO 300MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

1.1
1.2
1.4
1.4
1.4
1.4
1.2
1.4
1.4
1.4
1.4
1.6
1.4
1.6
1.8
1.6
1.8
2.0
1.8
2.0
R9
2.0
R9
R10
R9
R9
R11
R9
R11
R12

31

Plain annealed stranded copper conductors, XLPE insulated, lead sheathed,


PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000
volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flame
propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
EEMUA2X1/5
EEMUA3X1/5
EEMUA4X1/5
EEMUA2X2/5
EEMUA3X2/5
EEMUA4X2/5
EEMUA2X4
EEMUA3X4
EEMUA4X4
EEMUA2X6
EEMUA3X6
EEMUA4X6
EEMUA2X10
EEMUA3X10
EEMUA4X10
EEMUA2X16
EEMUA3X16
EEMUA4X16

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
1.5
2.5
2.5
2.5
4.0
4.0
4.0
6.0
6.0
6.0
10.0
10.0
10.0
16.0
16.0
16.0

7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/1.04
7/1.04
7/1.04
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/1.70

NO. OF
CORES
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
690
15.32
744
15.76
813
16.64
772
16.68
842
17.21
934
18.28
883
17.66
1190
18.27
1310
19.5
1001
18.66
1122
19.35
1402
21.64
1227
20.66
1493
22.2
1710
24.07
1565
23.30
1813
24.69
2191
26.68

GLAND
SIZE
(MM)
20S
20
20
20
20
25
20
20
25
25
25
25
25
25
25
25
32
32

SINGLE
CLEAT

Temperature limits:
-15 to +90C.
Bending radius:
12 x overall diameter.
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
Should not be installed at
temperatures below 0C.

XLPE INSULATED LEAD


SHEATHED MAINS CABLE
FOR PETRO-CHEMICAL
INDUSTRIES
(1.5MM2 TO 16MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.8
0.9
1.0
1.0
1.0
1.1

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

32

FIXED WIRING AND MAINS CABLES


Plain annealed stranded copper conductors, XLPE insulated, lead sheathed,
PVC bedding, galvanised steel wire armour, PVC outer sheath. Black.
1900/3300 volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B).
Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
EEMUA3X25/3
EEMUA3X35/3
EEMUA3X50/3
EEMUA3X70/3
EEMUA3X95/3
EEMUA3X120/3
EEMUA3X150/3
EEMUA3X185/3
EEMUA3X240/3
EEMUA3X300/3

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
25
35
50
70
95
120
150
185
240
300

7/2.14
19/1.53
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52

NO. OF
CORES
3
3
3
3
3
3
3
3
3
3

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
3400
32.5
3560
38.4
4520
38.1
5550
41.4
6770
45.0
8390
49.4
9630
52.3
11270
55.8
13720
60.9
16380
65.3

GLAND
SIZE
(MM)
32
40
40
50s
50s
50
50
63s
63
75s

Temperature limits:
-15 to +90C.

Core identification:
Brown, Black, Grey.

Bending radius:
12 x overall diameter.

Should not be installed at


temperatures below 0C.

SINGLE
CLEAT

XLPE INSULATED
LEAD SHEATHED MAINS
CABLE FOR
PETRO-CHEMICAL
INDUSTRIES
3300 VOLT
(25MM2 TO 300MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

1.4
1.6
1.6
1.8
2.0
2.0
R9
R9
R10
R11

33

SPLIT CONCENTRIC
Plain annealed stranded copper phase conductor, XLPE insulated surrounded
by a concentric layer of plain annealed solid copper neutral conductors. XLPE
insulated and plain annealed solid strand bare copper earth conductors, PVC
outer sheath. Black. 600/1000 volts grade to BS 4553/88.
CCC
CODE

CONDUCTOR
SIZE (MM2)

STRANDING
(MM)

WEIGHT
KG/KM

4 SPLITCON
6 SPLITCON
10 SPLITCON
16 SPLITCON
25 SPLITCON
35 SPLITCON

4
6
10
16
25
35

7/0.85
7/1.04
7/1.35
7/1.70
*7/2.14
7/2.52

206
281
394
583
843
1300

* Stranding of neutral is the same as


phase conductor except 25 sq mm
which has 11 x 1.70mm.
Conductor identification:
Brown Live/Blue Neutral.

OVERALL
DIAMETER
(MM)
9.6
11.4
12.7
14.6
18.7
23.0

GLAND
SIZE
(MM)
20S
20
20
25
32
40

Should not be installed at


temperatures below 0C.
Also available in Violet outer sheath
in 6mm, 10mm, 16mm & 25mm.

Straight CONCENTRIC (CNE)


Plain annealed stranded copper phase conductor, PVC insulated surrounded by
a concentric layer of plain annealed solid copper neutral/earth conductors in
concentric layer, PVC outer sheath. Black. 600/1000 volts grade to BS 4553/88
& ESI 09-7.
CCC
CODE

CONDUCTOR
SIZE (MM2)

STRANDING
(MM)

WEIGHT
KG/KM

4 STRCON
6 STRCON
16 STRCON
25 STRCON
35 STRCON

4
6
16
25
35

7/0.85
7/1.04
7/1.70
7/2.14
7/2.25

180
230
440
600
850

Temperature limits:
-15 to +70C.

OVERALL
DIAMETER
(MM)
9.0
10.0
12.0
15.0
16.0

GLAND
SIZE
(MM)
20S
20S
20
25
25

Should not be installed at


temperatures below 0C.

Bending radius:
10 x overall diameter.

XLPE INSULATED SINGLE


PHASE SPLIT AND
STRAIGHT CONCENTRIC
SERVICE CABLE
(4MM2 TO 35MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND MAINS CABLES

34

35

FLEXIBLE CABLES

FLEXIBLE CABLES

FLEXIBLE CABLES

36

FLEXIBLE CABLES
PVC INSULATED FLEXIBLE CORDS TYPE 318*Y
Plain annealed flexible copper conductors, PVC insulated, PVC outer sheath.
Black or White. 300/500 volts grade to BS6500. (Harmonized code HO5VV-F).
Flame propagation to BS4066 PT1 and IEC 332 PT1. (*HO3VV-F)
CCC
CODE
2182Y/5
2182Y/75
2183Y/5
2183Y/75
3182Y/5
3183Y/5
3182Y/75
3183Y/75
3184Y/75
3185Y/75
3182Y1
3183Y1
3184Y1
3185Y1
3182Y1/5
3183Y1/5
3184Y1/5
3185Y1/5
3182Y2/5
3183Y2/5
3184Y2/5
3185Y2/5

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.5
0.75
0.5
0.75
0.5
0.5
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5

16/0.2
24/0.2
16/0.2
24/0.2
16/0.2
16/0.2
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25

Temperature limits:
Fixed - -5 to +60C.
Flexing - +5 to +60C.
Bending radius:
Fixed 2 x overall diameter.
Flexing 6 x overall diameter.
Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.

NO. OF
CORES

WEIGHT
KG/KM

2
2
3
3
2
3
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5

36
45
44
55
52
5
59
70
85
110
69
82
105
130
95
120
150
180
145
180
220
265

OVERALL
DIAMETER
(MM)
5.4
5.8
5.6
6.1
6.3
6.3
6.8
7.2
7.7
8.5
7.2
7.6
8.5
9.1
8.2
8.9
10.0
11.0
9.9
10.8
11.3
12.8

GLAND
SIZE
(MM)
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20S
20/16
20/16
20S
20S
20/16
20S
20S
20
20S
20S
20
20

4 core - Blue, Brown, Black,


Green/Yellow.
5 core - Blue, Brown, Black, Black,
Green/Yellow.
Should not be installed at
temperatures below 0C.
Current ratings, see page 115.

PVC INSULATED
FLEXIBLE CORDS
TYPE 318*Y & 218*Y
(0.5MM2 TO 2.5MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

37

PVC INSULATED HEAT RESISTING FLEXIBLE CORDS TYPE 309*Y


Plain annealed flexible copper conductors heat resisting PVC outer sheath. White
300/500 volts grade to BS6141. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
3092Y/5
3093Y/5
3094Y/5
3092Y/75
3093Y/75
3094Y/75
3092Y1
3095Y/75
3093Y1
3094Y1
3092Y1/5
3093Y1/5
3094Y1/5
3092Y2/5
3093Y2/5
3094Y2/5

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.5
0.5
0.5
0.75
0.75
0.75
1.0
0.75
1.0
1.0
1.5
1.5
1.5
2.5
2.5
2.5

16/0.20
16/0.20
16/0.20
24/0.20
24/0.20
24/0.20
32/0.20
24/0.2
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
2
3
4
2
5
3
4
2
3
4
2
3
4

46
66
70
56
68
85
65
104
77
100
80
100
130
135
150
195

OVERALL
DIAMETER
(MM)
6.3
6.5
7.2
6.8
7.2
7.7
7.2
8.5
7.6
8.5
8.2
8.9
10.0
10.0
10.8
11.8

GLAND
SIZE
(MM)
20/16
20/16
20/16
20S
20S
20S
20S
20S
20S
20S
20S
20S
20
20S
20
20

Temperature limits:
Fixed - -5 to +90C.
Flexing - +5 to +90C.

Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.

Bending radius:
Fixed - 2 x overall diameter.
Flexing - 6 x overall diameter.

4 core - Blue, Brown, Black,


Green/Yellow.

Current ratings, see page 115.

Should not be installed at


temperatures below 0C.

PVC INSULATED
FLEXIBLE CORDS
TYPE 309*Y
(0.5MM2 TO 2.5MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

FLEXIBLE CABLES

FLEXIBLE CABLES

FLEXIBLE CABLES

38

FLEXIBLE CABLES
Plain annealed copper conductors, Low smoke and zero halogen (LS0H) insulated,
low smoke and zero halogen (LS0H) outer sheath. Black or white. 300/500 volts
grade (Generally to BS6500) flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
3182B/75
3183B/75
3184B/75
3185B/75
3182B1
3183B1
3184B1
3185B1
3182B1/5
3183B1/5
3184B1/5
3185B1/5
3182B2/5
3183B2/5
3184B2/5
3185B2/5

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
1.00
1.00
1.00
1.0
1.5
1.5
1.5
1.5
2.5
2.5
1.5
2.5

24/0.2
24/0.2
24/0.2
24/0.2
32/0.2
32/0.2
32/0.2
32/0.2
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25

Temperature limits:
-15 to +70c
Bending radius:
Fixed 4x overall diameter
Flexing 6x overall diameter

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5

6.8
7.2
7.7
8.5
7.2
7.6
8.5
130
8.2
8.9
10
11
9.9
10.8
11.3
265

OVERALL
DIAMETER
(MM)
59
70
85
110
69
82
105
9.1
95
120
150
180
145
180
220
12.8

GLAND
SIZE
(MM)
20/16
20/16
20/16
20S
20/16
20/16
20S
20S
20/16
20S
20S
20
20S
20S
20
20

Core identification:
2 core - Brown, Blue.
3 core - Blue, Brown, Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow.
5core - Blue, Brown, Black, Black,
Green/Yellow.

LOW SMOKE
ZERO HALOGEN FLEXIBLE
CORDS TYPE 318*B
(0.75MM2 TO 2.5MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

39

Plain annealed flexible copper conductors, PVC insulated, PVC sheathed. Grey.
300/500 volts grade, generally to BS6500 and VDE 0250.
CCC
CODE
YY2X/75
YY3X/75
YY4X/75
YY5X/75
YY7X/75
YY12X/75
YY18X/75
YY25X/75
YY34X/75
YY50X/75
YY65X/75
YY2X1
YY3X1
YY4X1
YY5X1
YY7X1
YY12X1
YY18X1
YY25X1
YY34X1
YY41X1
YY50X1
YY65X1
YY2X1/5
YY3X1/5
YY4X1/5
YY5X1/5
YY7X1/5
YY8X1/5
YY10X1/5
YY12X1/5
YY18X1/5
YY25X1/5
YY34X1/5
YY50X1/5
YY65X1/5

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25

Temperature limits:
-5 to +70C.
Bending radius:
Static - 6 x overall diameter.
Flexing - 15 x overall diameter.

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
5
7
12
18
25
34
50
65
2
3
4
5
7
12
18
25
34
41
50
65
2
3
4
5
7
8
10
12
18
25
34
50
65

53
63
76
93
116
194
278
379
516
734
912
60
73
89
109
137
229
331
452
615
770
879
1171
77
95
117
144
183
232
265
307
461
627
850
1212
1602

OVERALL
DIAMETER
(MM)
6.0
6.3
6.9
7.5
8.2
11.1
13.0
15.9
18.2
21.7
24.3
6.2
6.5
7.1
7.8
8.5
11.5
13.5
16.5
18.9
21.0
22.5
26.5
6.8
7.2
7.8
8.6
9.4
12.5
12.4
12.8
15.4
18.8
21.4
25.4
29.5

GLAND
SIZE
(MM)
20/16
20/16
20/16
20/16
20/16
20S
20
25
25
32
32
20/16
20/16
20/16
20/16
20S
20
25
25
25
32
32
40
20/16
20/16
20/16
20S
20S
20
20
20
25
25
32
40
40

Core identification:
2 core - Black with White numbers.
3 core and above - Black with White
numbers plus Green/Yellow.
Should not be installed at
temperatures below -5C.

PVC INSULATED FLEXIBLE


POWER AND CONTROL
CABLE TYPE YY
(0.75MM2 TO 1.5MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

FLEXIBLE CABLES

FLEXIBLE CABLES

FLEXIBLE CABLES

40

FLEXIBLE CABLES
CCC
CODE
YY2X2/5
YY3X2/5
YY4X2/5
YY5X2/5
YY7X2/5
YY8X2/5
YY12X2/5
YY18X2/5
YY25X2/5
YY34X2/5
YY3X4
YY4X4
YY5X4
YY7X4
YY3X6
YY4X6
YY5X6
YY7X6
YY3X10
YY4X10
YY5X10
YY3X16
YY4X16
YY5X16
YY4X25
YY5X25
YY4X35
YY5X35
YY4X50

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0
10.0
10.0
10.0
16.0
16.0
16.0
25.0
25.0
35.0
35.0
50.0

50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
56/0.30
56/0.30
56/0.30
56/0.30
84/0.30
84/0.30
84/0.30
84/0.30
80/0.40
80/0.40
80/0.40
126/0.40
126/0.40
126/0.40
196/0.40
196/0.40
276/0.40
276/0.40
396/0.40

Temperature limits:
-5 to +70C.

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
5
7
8
12
18
25
34
3
4
5
7
3
4
5
7
3
4
5
3
4
5
4
5
4
5
4

114
143
177
229
293
333
488
729
989
1338
230
289
357
457
326
480
583
782
610
737
914
812
1087
1370
960
1200
1344
1680
1920

OVERALL
DIAMETER
(MM)
8.0
8.5
9.3
10.6
11.6
13.5
15.7
18.8
22.9
26.0
11.6
12.0
13.2
14.4
13.2
14.4
16.6
18.6
16.7
18.8
20.9
18.5
22.2
25.0
25.8
29.3
28.9
33.1
34.5

GLAND
SIZE
(MM)
20/16
20S
20S
20S
20
25
25
25
32
40
20
20
20
25
20
25
25
25
25
25
32
25
32
32
32
40
40
50S
50S

Should not be installed at


temperatures below -5C.

Bending radius:
Static - 6 x overall diameter.
Flexing - 15 x overall diameter.
Core identification:
2 core - Black with White numbers.
3 core and above - Black with White
numbers plus Green/Yellow.

PVC INSULATED FLEXIBLE


POWER AND CONTROL
CABLE TYPE YY
(2.5MM2 TO 50MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

41

Plain annealed flexible copper conductors, low smoke and zero halogen (LSOH)
insulated, low smoke and zero halogen (LSOH) sheathed. Grey. 300/500 volts
grade, generally to BS6500 and VDE 0250.
CCC
CODE
YY2X1/5LSF
YY3X1/5LSF
YY4X1/5LSF
YY5X1/5LSF
YY7X1/5LSF
YY12X1/5LSF
YY18X1/5LSF
YY25X1/5LSF
YY34X1/5LSF
YY2X2/5LSF
YY3X2/5LSF
YY4X2/5LSF
YY5X2/5LSF
YY3X4LSF

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
4.0

30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
56/0.30

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
5
7
12
18
25
34
2
3
4
5
3

77
95
117
144
183
307
461
627
850
114
143
177
229
230

Temperature limits:
-5 to +70C

OVERALL
DIAMETER
(MM)
6.80
7.20
7.80
8.60
9.40
12.80
15.40
18.80
21.40
8.00
8.50
9.30
10.60
11.60

GLAND
SIZE
(MM)
20/16
20/16
20/16
20S
20S
20
25
25
32
20/16
20S
20S
20S
20

Core identification:
2 Core - Black with white numbers
3 Core and above
Black with white numbers plus
Green/Yellow

Bending radius:
Static
6 x Overall Diameter

Should not be installed at


temperatures below -5C.

Flexing:
15 x Overall Diameter

Plain annealed flexible copper conductors, low smoke and zero halogen (LSOH)
insulated, mylar taped, tinned copper wire braid, low smoke and zero halogen (LSOH)
outer sheath. Grey. 300/500 volts grade, generally to BS6500 and VDE 0250.
CCC
CODE
CY2X/75LSF
CY3X/75LSF
CY4X/75LSF
CY2X1/5LSF
CY3X1/5LSF
CY4X1/5LSF
CY5X1/5LSF

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
1.5
1.5
1.5
1.5

Temperature limits:
-5 to 70C
Bending radius:
Static
6 x Overall Diameter
Flexible:
15 x Overall Diameter

24/0.20
24/0.20
24/0.20
30/0.25
30/0.25
30/0.25
30/0.25

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
2
3
4
5

55
77
92
86
118
142
171

OVERALL
DIAMETER
(MM)
6.50
7.00
7.60
7.50
8.30
8.90
9.70

GLAND
SIZE
(MM)
20S
20S
20S
20S
20S
20S
20S

Core identification:
2 Core - Black with White numbers
3 Core and above
Black with White numbers plus
Green/Yellow
Should not be installed at
temperatures below -5C.

LSOH SHEATHED
FLEXIBLE POWER AND
CONTROL CABLE
TYPE YY
(1.5MM2 TO 4.0MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

FLEXIBLE CABLES

FLEXIBLE CABLES

FLEXIBLE CABLES

42

FLEXIBLE CABLES
Plain annealed flexible copper conductors, PVC insulated, extruded PVC
bedding, galvanised steel wire braid armour, transparent PVC outer sheath.
300/500 volts grade generally to BS6500 and VDE 0250 class 5.
CCC
CODE
SY2X/75
SY3X/75
SY4X/75
SY5X/75
SY7X/75
SY12X/75
SY18X/75
SY25X/75
SY34X/75
SY2X1
SY3X1
SY4X1
SY5X1
SY7X1
SY12X1
SY18X1
SY25X1
SY34X1
SY50X1
SY2X1/5
SY3X1/5
SY4X1/5
SY5X1/5
SY7X1/5
SY12X1/5
SY18X1/5
SY25X1/5
SY34X1/5
SY50X1/5
SY2X2/5
SY3X2/5
SY4X2/5
SY5X2/5
SY7X2/5
SY12X2/5
SY18X2/5
SY25X2/5
SY34X2/5

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25

Temperature limits:
-5 to +70C.
Bending radius:
Static - 10 x overall diameter.
Flexing - 20 x overall diameter.

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
5
7
12
18
25
34
2
3
4
5
7
12
18
25
34
50
2
3
4
5
7
12
18
25
34
50
2
3
4
5
7
12
18
25
34

87
121
138
164
190
302
433
569
684
101
133
152
181
213
361
490
647
810
1112
114
159
189
220
273
460
633
882
1108
1583
143
218
267
334
425
738
1100
1450
1870

OVERALL
DIAMETER
(MM)
9.0
9.1
9.7
10.3
11.0
14.3
16.8
19.7
21.8
9.2
9.3
9.9
10.6
11.3
14.7
17.3
20.3
21.8
23.9
9.8
10.0
10.6
11.4
12.6
16.6
19.2
23.2
26.2
32.8
11.0
11.3
12.5
13.8
15.0
22.1
26.5
31.5
33.7

GLAND
SIZE
(MM)
20/16
20/16
20/16
20/16
20/16
20S
20
20
25
20/16
20/16
20/16
20/16
20/16
20S
20
20
25
25
20/16
20/16
20/16
20/16
20/16
20
20
25
25
32
20/16
20/16
20/16
20S
20S
25
25
32
32

Core identification:
2 core - Black with White numbers.
3 core and above - Black with White
numbers plus Green/Yellow.
Should not be installed at
temperatures below -5C.

PVC INSULATED BRAIDED


FLEXIBLE CONTROL CABLE
TYPE SY
(0.75MM2 TO 2.5MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

43

CCC
CODE
SY3X4
SY4X4
SY5X4
SY7X4
SY3X6
SY4X6
SY5X6
SY7X6
SY3X10
SY4X10
SY5X10
SY3X16
SY4X16
SY5X16
SY4X25
SY5X25
SY4X35
SY5X35
SY4X50
SY4X70
SY4X95

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0
10.0
10.0
10.0
16.0
16.0
16.0
25.0
25.0
35.0
35.0
50.0
70.0
95.0

56/0.30
56/0.30
56/0.30
56/0.30
84/0.30
84/0.30
84/0.30
84/0.30
80/0.40
80/0.40
80/0.40
126/0.40
126/0.40
126/0.40
196/0.40
196/0.40
276/0.40
276/0.40
396/0.40
356/0.50
485/0.5

Temperature limits:
-5 to +70C.
Bending radius:
Static - 10 x overall diameter.
Flexing - 20 x overall diameter.

NO. OF
CORES

WEIGHT
KG/KM

3
4
5
7
3
4
5
7
3
4
5
3
4
5
4
5
4
5
4
4
4

312
384
556
685
407
508
663
789
621
779
1157
857
1384
1567
2021
2464
2500
3185
3518
4810
6360

OVERALL
DIAMETER
(MM)
14.8
15.8
18.1
19.6
16.2
17.9
19.3
21.4
17.2
21.9
25.6
20.6
27.5
28.3
33.8
37.4
34.5
36.7
40.3
44.2
50.2

GLAND
SIZE
(MM)
20S
20
20
20
20
20
20
25
20CX
25
25
25CX
32
32
40
40
40
40
505
50SCX
50CX

Core identification:
2 core - Black with White numbers.
3 core and above - Black with White
numbers plus Green/Yellow.
Should not be installed at
temperatures below -5C.

PVC INSULATED BRAIDED


FLEXIBLE CONTROL CABLE
TYPE SY
(4MM2 TO 95MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

FLEXIBLE CABLES

FLEXIBLE CABLES

FLEXIBLE CABLES

44

FLEXIBLE CABLES
Plain annealed flexible copper conductors, PVC insulated, mylar taped, tinned
copper wire braid screen, PVC outer sheath. Grey. 300/500 volts grade
generally to BS6500 and VDE 0250.
CCC
CODE
CY2X/75
CY3X/75
CY4X/75
CY5X/75
CY7X/75
CY12X/75
CY18X/75
CY25X/75
CY34X1
CY2X1
CY3X1
CY4X1
CY5X1
CY7X1
CY12X1
CY18X1
CY25X1
CY34X1
CY2X1/5
CY3X1/5
CY4X1/5
CY5X1/5
CY7X1/5
CY12X1/5
CY18X1/5
CY25X1/5
CY34X1/5
CY42X1/5
CY2X2/5
CY3X2/5
CY4X2/5
CY5X2/5
CY7X2/5
CY12X2/5
CY2X4
CY3X4
CY4X4
CY5X4
CY4X6
CY4X10

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
6.0
10.0

24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
56/0.30
56/0.30
56/0.30
56/0.30
84/0.30
80/0.40

Temperature limits:
Static - -20 to +80C.
Flexing - -5 to +70C.
Bending radius:
Static - 6 x overall diameter.
Flexing - 15 x overall diameter.

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
5
7
12
18
25
34
2
3
4
5
7
12
18
25
34
2
3
4
5
7
12
18
25
34
42
2
3
4
5
7
12
2
3
4
5
4
4

55
77
92
121
145
225
328
430
860
78
87
115
136
166
271
381
532
735
86
118
142
171
217
354
534
704
896
1133
140
164
206
252
327
557
206
269
305
396
411
783

OVERALL
DIAMETER
(MM)
6.5
7.0
7.6
8.6
9.3
11.8
14.1
16.8
17.1
7.1
7.2
8.2
8.9
9.6
12.6
14.6
17.8
21.1
7.5
8.3
8.9
9.7
10.5
13.9
16.7
19.7
22.4
23.9
8.1
9.6
10.4
11.3
12.7
17.0
11.7
12.4
12.7
14.9
14.4
16.2

GLAND
SIZE
(MM)
20S
20S
20S
20S
20S
20
25
25
25
20S
20S
20S
20S
20S
20
25
25
32
20S
20S
20S
20S
20
25
25
32
32
32
20/16
20S
20S
20
20
25
20
20
20
25
25
25

Core identification:
2 core - Black with White numbers.
3 core and above - Black with White
numbers plus Green/Yellow.
Should not be installed at
temperatures below -5C.

PVC INSULATED BRAID


SCREENED FLEXIBLE
POWER AND CONTROL
CABLETYPE CY
(0.75MM2 TO 10MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

45

Plain annealed stranded circular copper conductors, circular high temperature


PVC outer sheath. UL & CSA approved also to BS6231. 600/1000 volts grade.
CCC
CODE

CONDUCTOR
SIZE (MM2)

STRANDING
(MM)

WEIGHT
KG/KM

TRI0/5
TRI/75
TRI1
TRI1/5
TRI2/5
TRI4
TRI6
TRI10
TRI16
TRI25
TRI35
TRI50
TRI70
TRI95
TRI120
BI150
BI185
BI240
BI300
BI400

0.5
0.75
1.0
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150
185
240
300
400

16/0.20
24/0.20
32/0.20
30/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525.0.50
2013/0.50

12
15
18
23
34
50
71
123
207
303
412
607
837
1079
1280
1619
1948
2518
3112
4051

OVERALL
DIAMETER
(MM)
2.7
2.9
3.1
3.3
3.7
4.3
4.9
6.3
9.0
10.4
11.9
14.7
16.8
18.8
19.9
22.9
24.1
28.6
32.2
36

GLAND
SIZE
(MM)
20/16
20/16
20/16
20/16
20/16
20S
20S
20
25
25
25
32
32
32
40
505
50

Temperature limits:
-30 to +105C.

4.0mm2 - 16mm2 - Brown, Black, Grey,


Blue, Green/Yellow, Red, Yellow, White.

Should not be installed at


temperatures below 0C.

25.0mm2 - 120mm2 - Brown, Black,


Grey, Blue, Green/Yellow, Red, Yellow.

Standard colours available:


0.5mm2 - 2.5mm2 - Brown, Black,
Grey, Blue, Green/Yellow, Red, Yellow,
White, Orange, Pink, Violet.

150-400 - Black.
Current ratings on page 124

TRI-RATED SWITCHGEAR
AND CONTROL
PANEL WIRE
(0.5MM2 TO 400MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

FLEXIBLE CABLES

FLEXIBLE CABLES

FLEXIBLE CABLES

46

FLEXIBLE CABLES
Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR)
insulated, chlorosulphonated polyethylene (CSP) outer sheath. 300/500 volts
grade to BS6500.
Black or White. Flame propagation to BS4066 PT1 and IEC 332 PT1. Heat and
oil resistant and flame retardant (HOFR).
CCC
CODE
3182TQ/75
3183TQ/75
3184TQ/75
3182TQ1
3183TQ1
3184TQ1
3181TQ1/5
3182TQ1/5
3183TQ1/5
3184TQ1/5
3185TQ1/5
3186TQ1/5
3187TQ1/5
3180/12TQ1/5
3180/16TQ1/5
3180/20TQ1/5
3180/27TQ1/5
3180/37TQ1/5
3181TQ2/5
3182TQ2/5
3183TQ2/5
3184TQ2/5
3185TQ2/5
3187TQ2/5
3180/12TQ2/5
3180/16TQ2/5
3180/20TQ2/5
3180/27TQ2/5
3180/37TQ2/5

CONDUCTOR STRANDING
(MM)
SIZE (MM2)
0.75
0.75
0.75
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
2
3
4
1
2
3
4
5
6
7
12
16
20
27
37
1
2
3
4
5
7
12
16
20
27
37

58
72
86
80
90
110
38
115
135
170
200
335
366
410
570
710
920
1260
41
160
195
245
300
424
600
780
1050
1390
1720

OVERALL
DIAMETER
(MM)
6.3
6.8
7.4
8.8
9.2
10.0
4.9
10.5
11.0
12.5
13.5
12.2
13.6
17.1
19.3
21.8
28.2
28.9
5.5
12.5
13.0
14.0
15.5
15.8
20.0
22.5
25.4
29.1
36.8

GLAND
SIZE
(MM)
20/16
20/16
20/16
20S
20S
20S
20/16
20S
20S
20
25
20
25
25
25
32
40
40
20/16
20
20
20
25
25
32
32
32
40
50S

Temperature limits:
-25 to +90C.

Should not be installed at


temperatures below -25C.

Bending radius:
Fixed - 6 x overall diameter.
Flexing - 15 x overall diameter.

Current ratings, see page 115.

Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.
4 core - Grey, Black, Brown,
Green/Yellow.
5 core - Grey, Black, Brown, Blue,
Green/Yellow.
6 core and above - Black with White
numbers plus Green/Yellow.

EPR INSULATED HOFR


SHEATHED FLEXIBLE
POWER AND
CONTROL CABLE
(0.75MM2 TO 2.5MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

47

Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR)


insulated, chlorosulphonated polyethylene (CSP) outer sheath. Black. 450/750
volts grade to BS6007.
Heat and oil resistant and flame retardant (HOFR). Flame propagation to
BS4066 PT1 and IEC 322 PT1.
CCC
CODE
6381TQ4
6382TQ4
6383TQ4
6384TQ4
6385TQ4
6387TQ4
6380/12TQ4

CONDUCTOR STRANDING
(MM)
SIZE (MM2)
4.0
4.0
4.0
4.0
4.0
4.0
4.0

56/0.30
56/0.30
56/0.30
56/0.30
56/0.30
56/0.30
56/0.30

Temperature limits:
-25 to +90C.
Bending radius:
Fixed - 6 x overall diameter.
Flexing - 7 x overall diameter.

NO. OF
CORES

WEIGHT
KG/KM

1
2
3
4
5
7
12

105
275
335
420
515
773
1183

OVERALL
DIAMETER
(MM)
9.0
15.0
16.0
18.0
19.5
21.6
26.2

GLAND
SIZE
(MM)
20S
25
25
25
32
32
40

Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.
4 core - Grey, Black, Brown,
Green/Yellow.
5 core - Grey, Black, Brown, Blue,
Green/Yellow.
6 core and above - Black with White
numbers plus Green/Yellow.
Current ratings, see page 123.

EPR INSULATED
HEAVY DUTY
HOFR SHEATHED FLEXIBLE
MAINS CABLE (4MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

FLEXIBLE CABLES

FLEXIBLE CABLES

FLEXIBLE CABLES

48

FLEXIBLE CABLES
Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR)
insulated, chlorosulphonated polyethylene (CSP) outer sheath. Black. 450/750
volts grade to BS6007.
Heat and oil resistant and flame retardant (HOFR). Flame propagation to
BS4066 PT1 and IEC 322 PT1.
CCC
CODE

EPR INSULATED
HOFR SHEATHED
POWER AND
CONTROL CABLE
(6MM2 TO 630MM2)

6381TQ6
6382TQ6
6383TQ6
6384TQ6
6385TQ6
6387TQ6
6388TQ6
6381TQ10
6382TQ10
6383TQ10
6384TQ10
6385TQ10
6381TQ16
6382TQ16
6383TQ16
6384TQ16
6385TQ16
6381TQ25
6382TQ25
6383TQ25
6384TQ25
6385TQ25
6381TQ35
6382TQ35
6383TQ35
6384TQ35
6385TQ35
6381TQ50
6383TQ50
6384TQ50
6385TQ50
6381TQ70
6383TQ70
6384TQ70
6385TQ70
6381TQ95
6383TQ95
6384TQ95
6385TQ95
6381TQ120
6383TQ120
6384TQ120
6381TQ150
6383TQ150
6384TQ150
6381TQ185
6383TQ185
6384TQ185
6381TQ240
6383TQ240
6384TQ240
6381TQ300
6383TQ300
6384TQ300
6381TQ400
6381TQ500
6381TQ630

CONDUCTOR STRANDING
(MM)
SIZE (MM2)
6
6
6
6
6
6
6
10
10
10
10
10
16
16
16
16
16
25
25
25
25
25
35
35
35
35
35
50
50
50
50
70
70
70
70
95
95
95
95
120
120
120
150
150
150
185
185
185
240
240
240
300
300
300
400
500
630

84/0.30
84/0.30
84/0.30
84/0.30
84/0.30
84/0.30
84/0.30
80/0.40
80/0.40
80/0.40
80/0.40
80/0.40
126/0.40
126/0.40
126/0.40
126/0.40
126/0.40
196/0.40
196/0.40
196/0.40
196/0.40
196/0.40
276/0.40
276/0.40
276/0.40
276/0.40
276/0.40
396/0.40
396/0.40
396/0.40
396/0.40
360/0.50
360/0.50
360/0.50
360/0.50
475/0.50
475/0.50
475/0.50
475/0.50
608/0.50
608/0.50
608/0.50
756/0.50
756/0.50
756/0.50
925/0.50
925/0.50
925/0.50
1221/0.50
1221/0.50
1221/0.50
1525/0.50
1525/0.50
1525/0.50
2013/0.50
1769/0.60
2257/0.60

Temperature limits:
-25 to +90C.
Bending radius:
Fixed - 5 x overall diameter.
Flexing - 7 x overall diameter.
Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.

NO. OF
CORES

WEIGHT
KG/KM

1
2
3
4
5
7
8
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
3
4
5
1
3
4
5
1
3
4
5
1
3
4
1
3
4
1
3
4
1
3
4
1
3
4
1
1
1

130
370
450
565
690
904
1040
200
690
835
1020
1240
275
910
1120
1380
1695
400
1290
1600
2140
2470
520
1308
2080
2610
3187
730
2890
3650
4450
980
3850
4880
5938
1270
4970
6390
7924
1570
6350
7750
1960
7700
9780
2380
9350
11900
3100
12000
15330
3790
14910
19030
4880
6070
7460

OVERALL
DIAMETER
(MM)
11.0
15.6
16.6
18.5
20.5
25.7
27.2
12.5
20.6
22.1
24.1
26.5
14.5
23.2
24.8
27.1
30.1
16.5
27.4
29.3
32.5
36.1
18.5
30.4
32.9
36.5
40.5
21.0
38.5
42.6
47.3
23.5
43.6
48.6
54.0
26.0
50.0
56.0
62.0
28.5
56.8
59.9
31.5
59.9
66.8
34.5
65.9
73.5
38.0
74.7
83.2
41.5
83.2
92.8
46.5
51.5
56.5

GLAND
SIZE
(MM)
20S
25
25
25
32
40
40
20
32
32
32
40
25
32
32
40
40
25
40
40
50S
50S
25
40
50S
50S
50
32
50
50
63S
32
63S
63S
63
40
63
75S
75
40
75S
75S
40
75S
75
50S
75
90
50
90
50
63S
63
75S

4 core - Grey, Black, Brown,


Green/Yellow.
5 core - Grey, Black, Brown, Blue,
Green/Yellow.
6 core and above - Black with White
numbers plus Green/Yellow.
Should not be installed at
temperatures below -25C.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

49

Plain annealed flexible copper conductors, rubber insulated, heavy duty


polychloroprene (PCP) outer sheath 450/750 volts grade. Black. Harmonized
code type HO7RN-F.
CCC
CODE
3182P1/5
3183P1/5
3184P1/5
3185P1/5
3187P1/5
3180/12P1/5
3182P2/5
3183P2/5
3184P2/5
3185P2/5
3187P2/5
3180/12P2/5
3182P4
3183P4
3184P4
3185P4
6382P6
6383P6
6384P6
6385P6
6381P10
6382P10
6383P10
6384P10
6385P10
6381P16
6382P16
6383P16
6384P16
6385P16
6381P25
6382P25
6383P25
6384P25
6385P25
6381P35
6383P35
6384P35
6385P35
6381P50
6384P50
6381P70
6384P70
6381P95
6384P95
6381P120
6381P150
6381P185
6381P240
6381P300

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0
10
10
10
10
10
16
16
16
16
16
25
25
25
25
25
35
35
35
35
50
50
70
70
95
95
120
150
185
240
300

30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
56/0.30
56/0.30
56/0.30
56/0.30
84/0.30
84/0.30
84/0.30
84/0.30
80/0.40
80/0.40
80/0.40
80/0.40
80/0.40
126/0.40
126/0.40
126/0.40
126/0.40
126/0.40
196/0.40
196/0.40
196/0.40
196/0.40
196/0.40
276/0.40
276/0.40
276/0.40
276/0.40
396/0.40
396/0.40
360/0.50
360/0.50
475/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525/0.50

Temperature limits:
-25 to +85C.

RUBBER INSULATED
NEOPRENE SHEATHED
FLEXIBLE
POWER CABLE
(1.5MM2 TO 300MM2)

Bending radius:
Static - 6 x overall diameter.
Flexing - 15 x overall diameter.
Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
5
7
12
2
3
4
5
7
12
2
3
4
5
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
3
4
5
1
4
1
4
1
4
1
1
1
1
1

132
165
200
240
385
520
193
235
290
345
520
810
275
320
395
485
350
495
610
760
230
640
880
1060
1300
320
850
1090
1345
1680
450
1210
1394
1995
2470
605
1850
2645
2930
825
3635
1090
4830
1405
6320
1745
1824
2202
2847
3495

OVERALL
DIAMETER
(MM)
9.3
10.3
11.2
12.3
14.6
20.3
12.0
11.8
12.6
14.3
16.6
22.0
15.0
13.7
15.1
16.9
18.5
15.2
16.9
18.8
10.7
24.0
21.9
24.0
25.5
12.0
27.5
24.7
27.0
30.0
14.1
31.5
29.4
32.6
36.1
15.8
32.8
36.3
39.8
18.3
41.9
20.7
48.2
23.4
55.0
25.6
28.3
31.0
34.5
37.7

GLAND
SIZE
(MM)
20
20S
20S
20
25
32
20
20
20
25
25
32
25
25
25
25
25
25
25
25
20S
32
32
32
32
20
40
32
40
40
25
40
40
50S
50S
25
50S
50S
50
25
50
32
63S
32
75S
40
40
40
50S
50

4 core - Grey, Black, Brown,


Green/Yellow.
5 core - Grey, Black, Brown, Blue,
Green/Yellow.
6 core and above - Black with White
numbers plus Green/Yellow.
Should not be installed at
temperatures below 0C.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

FLEXIBLE CABLES

FLEXIBLE CABLES

FLEXIBLE CABLES

50

FLEXIBLE CABLES
Flexible tinned annealed copper conductors, ethylene propylene rubber
insulated, chlorosulphonated polyethylene bedding (CSP), tinned copper wire
braid screen, chlorosulphonated polyethylene (CSP) outer sheath. 300/500
volts grade to BS6500/75 and 450/750 Volts grade to BS6007/75 (where
applicable). Black. Flame propogation to BS 4066 PT1 and IEC 332 PT1.
Heat and oil resistant and flame retardant (HOFR).
CCC
CODE
3802TQ1
3803TQ1
3804TQ1
3802TQ1/5
3803TQ1/5
3804TQ1/5
3802TQ2/5
3803TQ2/5
3804TQ2/5
3803TQ4
3804TQ4
6803TQ6
6804TQ6
6803TQ10
6804TQ10
6803TQ16
6804TQ16

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.0
1.0
1.0
1.5
1.5
1.5
2.5
2.5
2.5
4.0
4.0
6.0
6.0
10.0
10.0
16.0
16.0

32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
56/0.30
56/0.30
84/0.30
84/0.30
90/0.40
90/0.40
126/0.40
126/0.40

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
2
3
4
2
3
4
3
4
3
4
3
4
3
4

170
200
230
225
270
320
300
350
420
715
865
973
1166
1592
1878
1992
2452

OVERALL
DIAMETER
(MM)
11.1
11.4
12.1
12.3
13.1
14.2
14.8
15.6
17.0
21.3
23.6
24.8
27.1
30.7
33.3
33.8
37.2

GLAND
SIZE
(MM)
20/16
20/16
20/16
20/16
20S
20S
20S
20
20
25
25
25
32
32
40
40
40

Temperature limits:
-25 to +90C.

Should not be installed at


temperatures below 0C.

Bending radius:
8 x overall diameter.

Current ratings, see page 122&123.

Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.
4 core - Grey, Black, Brown, Blue,
Green/Yellow.

EPR INSULATED BRAIDED


SCREEN FLEXIBLE MAINS
AND CONTROL CABLE
(1.0MM2 TO 16MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

51

Flexible tinned annealed copper conductors composite ethylene propylene rubber


chlorosulphonated polyethylene (EPR-CSP) insulation to BS6195/69 Type 4.
A. 300/500 volts grade
C. 600/1000 volts grade
D. 1900/3300 volts grade

E. 3800/6600 volts grade


F. 6350/11000 volts grade

CONDUCTOR

CCC CODE

SIZE
(MM2)

STRANDING
(MM2)

TYPE 4 1/5
TYPE 4 2/5
TYPE 4 4
TYPE 4 6
TYPE 4 10
TYPE 4 16
TYPE 4 25
TYPE 4 35
TYPE 4 50
TYPE 4 70
TYPE 4 95
TYPE 4 120
TYPE 4 150
TYPE 4 185
TYPE 4 240
TYPE 4 300
TYPE 4 400

0.5
0.75
1.0
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400

16/0.20
24/0.20
32/0.20
30/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525/0.50
2013/0.50

CCC CODE

TYPE 4 1/5
TYPE 4 2/5
TYPE 4 4
TYPE 4 6
TYPE 4 10
TYPE 4 16
TYPE 4 25
TYPE 4 35
TYPE 4 50
TYPE 4 70
TYPE 4 95
TYPE 4 120
TYPE 4 150
TYPE 4 185
TYPE 4 240
TYPE 4 300
TYPE 4 400

MINIMUM OVERALL DIAMETER


WEIGHT
VOLTAGE CATEGORY
VOLTAGE CATEGORY
A
C
D
E
F
A
C
D
E
(MM) (MM) (MM) (MM) (MM) KG/KM KG/KM KG/KM KG/KM
3.3
4.5
12
17
3.5
4.7
16
21
19
24
4.9
3.7
4.0
5.2
25
30
4.6
5.6
8.5
37
41
76
57
66
6.3
5.4
7.5
80
93
6.5
7.9
8.5
130
136
9.6
12.4
17.2
22.9
206
255
384
11.4
13.8
18.6
24.1
300
351
495
12.8
15.2
20.0
25.5
406
458
613
14.8
17.1
21.1
27.3
573
616
796
17.2
19.2
24.2
29.4
793
820
1020
19.7
22.0
26.3
31.5
1028 1097 1287
27.8
33.3
1285 1340 1542
23.5
21.9
24.1
25.5
29.8
35.3
1562 1635 1853
26.3
27.5
32.1
37.3
1914 1973 2225
2431 2504 2782
40.3
35.1
30.5
29.3
33.0
33.8
3024 3098
37.4
37.8
3948 4045
-

Temperature limits:
-20 to +90C.

EPR INSULATED FLEXIBLE


COIL LEAD
(0.5MM2 TO 400MM2)

RADIAL THICKNESS OF INSULATION


VOLTAGE CATEGORY
A
C
D
E
F
MAX APPROX.
DIA. OF DIA. OF (MM) (MM) (MM) (MM) (MM)
WIRES COND.
(MM) (MM)
0.21
0.93
0.8
1.4
0.21
1.14
0.8
1.4
0.21
1.32
0.8
1.4
0.26
1.60
0.8
1.4
0.26
2.00
0.9
1.4
2.8
0.31
2.6
1.0
1.4
0.31
3.6
1.0
1.5
0.41
4.6
1.2
1.5
0.41
5.7
1.5
2.8
5.0
7.6
0.41
7.1
1.6
2.8
5.0
7.6
0.41
8.5
1.6
2.8
5.0
7.6
0.41
10.3
1.7
2.8
5.0
7.6
0.51
12.4
1.8
2.8
5.0
7.6
0.51
14.5
2.0
3.0
5.0
7.6
0.51
16.0
2.2
3.0
5.0
7.6
0.51
18.0
2.3
3.0
5.0
7.6
0.51
20.0
2.4
3.0
5.0
7.6
0.51
23.0
2.4
3.0
5.0
7.6
0.51
26.0
2.6
3.0
0.51
30.0
2.8
3.0
-

Should not be installed at


temperatures below -25C.

Bending radius:
6 x overall diameter.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

F
KG/KM
566
680
810
997
1237
1520
1804
2131
2503
3081
-

FLEXIBLE CABLES

FLEXIBLE CABLES

FLEXIBLE CABLES

52

FLEXIBLE CABLES
Tinned annealed flexible circular copper conductors, ethylene propylene
rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath.
Orange. Ref 0361TQ.
To BS638 Part 4.
CCC
CODE

CONDUCTOR
SIZE (MM2)

STRANDING
(MM)

WEIGHT
KG/KM

0361TQ16OR
0361TQ25OR
0361TQ35OR
0361TQ50OR
0361TQ70OR
0361TQ95OR
0361TQ120OR
0361TQ185OR

16
25
35
50
70
95
120
185

513/0.20
783/0.20
1107/0.20
1566/0.20
2214/0.20
2997/0.20
608/0.50
925/0.50

235
330
440
610
840
1120
1410
2100

Temperature limits:
-20 to +85C.

OUTSIDE
DIAMETER
(MM)
11.5
13.0
14.5
17.0
19.5
22.0
24.0
29.0

GLAND
SIZE
(MM)
20S
20
25
25
32
32
32
40

Bending radius:
6 x overall diameter.

EPR INSULATED FLEXIBLE


WELDING CABLE
TYPE 0361TQ
(16MM2 TO 185MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

53

RUBBER INSULATED FLAT CABLE


Flexible plain copper conductors, thermoplastic rubber insulated (TPR)
thermoplastic outer sheath (TPR). Black. 600/1000 volts grade.
CCC
CODE
FLAT4X1/5R
FLAT12X1/5R
FLAT4X2/5R
FLAT7X2/5R
FLAT12X2/5R
FLAT4X4R
FLAT4X6R
FLAT4X10R
FLAT4X16R
FLAT4X25R
FLAT4X35R
FLAT4X50R
FLAT4X70R

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
2.5
2.5
2.5
4
6
10
16
25
35
50
70

30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50

Temperature limits:
-35 to +85C.

NO. OF
CORES

WEIGHT
KG/KM

4
12
4
7
12
4
4
4
4
4
4
4
4

110
320
170
300
490
250
330
550
800
1350
1800
2400
3250

OVERALL MAX CURRENT


DIMENSIONS RATINGS
(MM)
(AMPS)
16X5
22
29X5
12
19X6
30
33X7
20
51X6
20
21X7
40
24X7
52
29X9
70
35X10
95
46X14
127
51X15
157
56X17
190
63X18
242

7 and 12 core - Black cores with


White numbers and one
Green/Yellow.

Bending radius:
10 x overall diameter.
Core identification:
4 core - Black, Grey, Brown,
Green/Yellow.

Should not be installed at


temperatures below 0C.

PVC INSULATED FLAT CABLE


Flexible plain copper conductors, PVC insulated, special PVC outer sheath. Black.
450/750 volts grade type H07VVH6-F. CENELEC HD 359 S2 IEC 227 part 6.
CCC
CODE
FLAT4X1/5V
FLAT12X1/5V
FLAT4X2/5V
FLAT12X2/5V
FLAT4X4V
FLAT4X6V
FLAT4X10V
FLAT4X16V
FLAT4X25V
FLAT4X35V
FLAT4X50V
FLAT4X70V
FLAT4X95V

RUBBER INSULATED
FLAT CABLE
(1.5MM2 TO 70MM2)
AND PVC INSULATED
FLAT CABLE
(1.5MM2 TO 95MM2)

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
2.5
2.5
4
6
10
16
25
35
50
70
95

30/0.25
30/0.25
50/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50

NO. OF
CORES

WEIGHT
KG/KM

4
12
4
12
4
4
4
4
4
4
4
4
4

150
420
210
620
300
385
620
990
1550
2030
2650
3650
4550

OVERALL MAX CURRENT


DIMENSIONS RATINGS
(MM)
(AMPS)
15X5
20
41X5
11
19X6
27
51X6
16
21X7
36
23X7
48
29X9
63
37X11
85
46X14
112
51X15
138
56X17
168
63X18
213
73X21
258

Temperature limits:
-25 to +70C.

12 core - Black cores with white


numbers and one Green/Yellow.

Bending radius:
10 x overall diameter.

Should not be installed at


temperatures below 0C.

Core identification:
4 core - Black, Grey, Brown,
Green/Yellow.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

FLEXIBLE CABLES

FLEXIBLE CABLES

FLEXIBLE CABLES

54

FLEXIBLE CABLES
Flexible tinned annealed copper conductors, silicone insulated, silicone outer
sheath. 300/500 volts grade to VDE 0250 PT816.
CCC
CODE
BIHF2X/75
BIHF3X/75
BIHF4X/75
BIHF5X/75
BIHF7X/75
BIHF2X1
BIHF3X1
BIHF4X1
BIHF5X1
BIHF7X1
BIHF2X1/5
BIHF3X1/5
BIHF4X1/5
BIHF5X1/5
BIHF7X1/5
BIHF2X2/5
BIHF3X2/5
BIHF4X2/5
BIHF5X2/5
BIHF7X2/5

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5

24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25

Temperature limits:
-60 to +180C.
Bending radius:
Fixed - 5 x overall diameter.
Flexing - 15 x overall diameter.

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
5
7
2
3
4
5
7
2
3
4
5
7
2
3
4
5
7

53.4
63.7
83.6
101.2
124.9
59.9
78.3
94.6
116.1
144.3
82.0
98.0
122.0
148.0
187.0
135.0
152.0
188.0
230.0
293.0

OVERALL
DIAMETER
(MM)
6.5
6.9
7.9
8.6
9.3
6.7
7.5
8.1
8.9
9.6
7.6
8.0
8.8
9.6
10.4
8.9
9.1
10.1
10.9
13.1

GLAND
SIZE
(MM)
20/16
20/16
20/16
20S
20S
20/16
20/16
20S
20S
20S
20/16
20/16
20S
20S
20S
20S
20S
20S
20S
20

Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.
4 core - Grey, Black, Brown,
Green/Yellow.
5 core and above - Grey, Black, Brown,
Blue, Green/Yellow
6 core and above - Black with White
numbers plus Green/Yellow.
Should not be installed at
temperatures below 0C.

SILICONE INSULATED
FLEXIBLE CABLE
(0.75MM2 TO 2.5MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

55

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

INSTRUMENTATION,
CONTROL AND
COMMUNICATION
CABLES

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

56

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES
PART 1 CONSTRUCTION
Plain annealed flexible copper conductors, polyethylene insulated, laid up to
form pairs, collective aluminium/mylar tape screen complete with 0.5mm2
drain wire, PVC outer sheath reduced propagation, Blue or Black to BS5308
Part 1 Type 1. Flame propagation to BS4066 PT1 and IEC 332 PT1. (Bunched
cables to BS4066 PT3 and IEC 332 PT3).
PART 2 CONSTRUCTION
Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs,
collective aluminium/mylar tape screen complete with 0.5mm2 drain wire,
PVC outer sheath reduced propagation. Blue or Black to BS5308 Part 2 Type1.
Flame propagation to BS4066 PT3 and IEC 332 PT3.
CCC CODE
PT1

PT2

7100
7101
7102
7103
7104
7105
7106
7107
7136
7137
7138
7139
7140
7141
7142
7143
7173
7174
7175
7176
7177
N/A
N/A
7178

7300
7301
7302
7303
7304
7305
7306
7307
7336
7337
7338
7339
7340
7341
7342
7343
7373
7374
7375
7376
7377
N/A
N/A
7378

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53

NO. OF
PAIRS
1
2
5
10
20
30
50
1 TRIPLE
1
2
5
10
20
30
50
1 TRIPLE
1
2
5
10
20
30
50
1 TRIPLE

WEIGHT OUTSIDE
KG/KM DIAMETER
(MM)
60
6.4
80
7.3
200
12.5
340
16.6
570
21.7
790
26.3
1270
33.3
69
6.6
75
6.7
100
7.7
250
13.7
450
18.1
800
23.9
1130
28.9
1840
36.8
88
6.9
100
7.7
150
9.1
360
15.8
670
21.0
1230
27.9
1720
33.7
2750
43.6
128
8.1

GLAND
SIZE
(MM)
20/16
20/16
20
25
32
40
50S
20/16
20/16
20/16
25
25
32
40
50S
20/16
20/16
20S
25
32
40
50S
63S
20/16

BS5308 PART 1, LSF


Plain annealed flexible copper conductors, polyethylene insulated, laid up to form
pairs, collective aluminium/mylar tape screen complete with 0.5mm2 drain wire,
low smoke and fume (LSF) sheath, Blue or Black, to BS5308 Part 1, Type 1 LSF.
CCC
CODE
7246
7247
7248
7249
7250

CONTROL AND
INSTRUMENTATION CABLE
NON-ARMOURED WITH
COLLECTIVE SCREEN
(0.5MM2 TO 1.5MM2)

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
0.75

Temperature limits:
-20 to +65C.
Bending radius:
5 x overall diameter.

24/0.20
24/0.20
24/0.20
24/0.20
24/0.20

NO. OF
CORES

WEIGHT
KG/KM

1
2
5
10
20

75
100
250
450
800

OVERALL
DIAMETER
(MM)
6.7
7.7
13.7
18.1
23.9

GLAND
SIZE
(MM)
20/16
20/16
25
25
32

Core identification:
Part 1 colour code chart on page 62
Part 2 colour code chart on page 63
Should not be installed at
temperatures below 0C.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

57

BS5308 PART 1, TYPE 1


Plain annealed flexible copper conductors, polyethylene insulated, laid up to
form pairs, each pair individually aluminium/mylar foil tape screened,
complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen
complete with 0.5mm2 drain wire, PVC outer sheath reduced propagation.
Blue or Black. Flame propagation to BS4066 PT1 and IEC 332 PT1. (Bunched
cables to BS4066 PT3 and IEC 332 PT3).
BS5308 PART 2, TYPE 1
Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs,
each pair individually aluminium/mylar foil tape screened complete with
0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete with
0.5mm2 drain wire, PVC outer sheath reduced propagation. Blue or Black.
Flame propagation to BS4066 PT1 and IEC 332 PT1. (Bunched cables to BS4066
PT3 and IEC 332 PT3).

CCC CODE
PT1

PT2

7112
7113
7114
7115
7116
7117
7149
7150
7151
7152
7153
7154
7185
7186
7187
7188

7312
7313
7314
7315
7316
7317
7349
7350
7351
7352
7353
7354
7385
7386
7387
7388

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.5
0.5
0.5
0.5
0.5
0.5
0.75
0.75
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5
1.5
1.5

16/0/20
16/0/20
16/0/20
16/0/20
16/0/20
16/0/20
24/0/20
24/0/20
24/0/20
24/0/20
24/0/20
24/0/20
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53

NO. OF
PAIRS
2
5
10
20
30
50
2
5
10
20
30
50
2
5
10
20
30
50

WEIGHT OUTSIDE
KG/KM DIAMETER
(MM)
160
11.4
250
14.6
480
20.5
780
26.7
1100
31.7
1590
41.1
190
12.2
270
15.7
550
21.8
960
28.5
1320
33.7
2120
44.0
250
13.7
400
17.8
800
25.2
1400
33.8
2040
40.4
3260
52.2

GLAND
SIZE
(MM)
20S
25
32
40
40
50
20
25
32
40
50S
63S
25
25
32
50S
50
63

BS5308 PART 1, TYPE 1 LS0H


Plain annealed flexible copper conductors, polyethylene insulated, laid up to
form pairs, each pair individually aluminium/mylar tape screened. Complete
with 0.5mm2 drain wire, collective aluminium/mylar tape screen complete
with 0.5mm2 drain wire, low smoke zero halogen (LS0H) outer sheath, Black or
Blue, generally to BS5308 Part 1, Type 1 LS0H.
CCC
CODE
71149
71150
71151
71152

CONTROL AND
INSTRUMENTATION CABLE
NON-ARMOURED WITH
INDIVIDUAL AND
COLLECTIVE SCREENS
(0.5MM2 TO 1.5MM2)

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75

Temperature limits:
-20 to +65C.
Bending radius:
5 x overall diameter.

24/0.20
24/0.20
24/0.20
24/0.20

NO. OF
CORES

WEIGHT
KG/KM

2
5
10
20

190
270
550
960

OVERALL
DIAMETER
(MM)
12.2
15.7
21.8
28.5

GLAND
SIZE
(MM)
20
25
32
40

Core identification:
Part 1 colour code chart on page 62.
Part 2 colour code chart on page 63.
Should not be installed at
temperatures below 0C.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

58

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES
BS5308 PART 1, TYPE 2
Plain annealed flexible copper conductors, polyethylene insulated, laid up to
form pairs, collective aluminium/mylar foil tape screen, complete with
0.5mm2 drain wire, Polytheylene bedding, galvanised steel wire armour, PVC
outer sheath reduced propagation. Blue or Black. Flame propagation to
BS4066 PT1 and IEC 332 PT1. (Bunched cables to BS4066 PT3 and IEC 332 PT3).
BS5308 PART 2, TYPE 2
Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs,
collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire,
Polytheylenebedding, galvanised steel wire armour, PVC outer sheath reduced
propagation. Blue or Black. Flame propagation to BS4066 PT1 and IEC 332 PT1.
(Bunched cables to BS4066 PT3 and IEC 332 PT3).
PT1

CCC CODE

7118
7119
7120
7121
7122
7123
7124
7125
7155
7156
7157
7158
7159
7160
7161
7162
7189
7190
7191
7192
7193
7194
7195
7196
7208
7209
7210
7211
7212
7213

PT2

7318
7319
7320
7321
7322
7323
7324
7325
7355
7356
7357
7358
7359
7360
7361
7362
7389
7390
7391
7392
7393
7394
7395
7396
7408
7409
7410
7411
7412
7413

CONDUCTOR STRANDING No. OF WEIGHT OVERALL


SIZE (MM2)
(MM)
PAIRS KG/KM DIAMETER
(MM)
(MM)
0.5
16/0/20
1
250
10.8
0.5
16/0/20
2
300
11.7
0.5
16/0/20
5
560
17.3
0.5
16/0/20
10
970
22.3
0.5
16/0/20
20
1640
28.5
0.5
16/0/20
30
2110
33.3
0.5
16/0/20
50
3270
41.5
0.5
16/0/20 1 TRIPLE 276
11.0
0.75
24/0/20
1
280
11.1
0.75
24/0/20
2
330
12.3
0.75
24/0/20
5
750
19.2
0.75
24/0/20
10
1260
24.7
0.75
24/0/20
20
1890
30.7
0.75
24/0/20
30
2440
36.9
0.75
24/0/20
50
3890
46.4
0.75
24/0/20 1 TRIPLE 307
11.4
1.5
7/0/53
1
330
12.3
1.5
7/0/53
2
420
13.7
1.5
7/0/53
5
940
21.5
1.5
7/0/53
10
1050
27.8
1.5
7/0/53
20
2400
35.1
1.5
7/0/53
30
3120
41.9
1.5
7/0/53
50
5310
53.4
1.5
7/0/53 1 TRIPLE 376
12.6
2.5
7/0/67
1
395
13.1
2.5
7/0/67
2
490
15.9
2.5
7/0/67
5
1430
26.5
2.5
7/0/67
10
2235
35.1
2.5
7/0/67
20
3935
46.7
13.7
7/0/67 1 TRIPLE 407
2.5

GLAND
SIZE
(MM)
20/16
20/16
20
25
32
40
50S
20/16
20/16
20/16
20
25
32
40
50
20/16
20/16
20S
25
32
40
50S
63S
20/16
20S
20
20
40
50
20S

CLEAT
SIZE
0.5
0.5
0.7
0.9
1.2
1.4
1.8
0.5
0.5
0.5
0.8
1.0
1.4
1.6
2.0
0.5
0.5
0.6
0.9
1.2
1.4
1.8
R9
0.5
0.6
0.6
1.1
1.4
2.0
0.6

BS5308 PART 1, TYPE 2 LS0H


Plain annealed flexible copper conductors, polyethylene insulated, laid up to form
pairs, collective aluminium/mylar foil tape screen, complete with 0.5mm2 drain wire,
low smoke zero halogen bedding (LS0H), galvanised steel wire armour, low smoke
zero halogen (LS0H) sheath, Black or Blue, generally to BS5308 Part 1, Type 2 LS0H.
CCC
CODE
7255
7256
7257
7258
7259
7289
7290
7291
7292
7293

CONTROL AND
INSTRUMENTATION CABLE
ARMOURED WITH
COLLECTIVE SCREEN
(0.5MM2 TO 2.5MM2)

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5
1.5

Temperature limits:
-20 to +65C.
Bending radius:
6 x overall diameter..

24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53

NO. OF
PAIRS
1
2
5
10
20
1
2
5
10
20

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
280
11.1
330
12.3
750
19.2
1260
24.7
1890
30.7
330
12.3
420
13.7
940
21.5
1050
27.8
2400
35.1

GLAND
SIZE
(MM)
20/16
20/16
20
25
32
20/16
205
25
32
40

CLEAT
SIZE
(MM)
0.5
0.5
0.8
1.0
1.4
0.5
0.6
0.9
1.2
1.4

Core identification:
Part 1 colour code chart on page 62.
Part 2 colour code chart on page 63.
Should not be installed at
temperatures below 0C.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

59

BS5308 PART 1, TYPE 2


Plain annealed flexible copper conductors, polyethylene insulated, laid up to
form pairs, each pair individually aluminium/mylar foil tape screened, complete
with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen, complete
with 0.5mm2 drain wire, polyethylene bedding, galvanised steel wire armour,
PVC outer sheath reduced propagation. Blue or Black. Flame propagation to
BS4066 PT1 and IEC 332 PT1. (Bunched cables to BS4066 PT3 and IEC 332 PT3).
BS5308 PART 2, TYPE 2
Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs,
each pair individually aluminium/mylar foil tape screened, complete with
0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete with
0.5mm2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer
sheath reduced propagation. Blue or Black. Flame propagation to BS4066 PT1
and IEC 332 PT1. (Bunched cables to BS4066 PT3 and IEC 332 PT3).
CCC CODE
PT1

PT2

7130
7131
7132
7133
7134
7135
7167
7168
7169
7170
7171
7172
7201
7202
7203
7204
7205
7206

7330
7331
7332
7333
7334
7335
7367
7368
7369
7370
7371
7372
7401
7402
7403
7404
7405
7406

CONDUCTOR STRANDING No. OF WEIGHT OVERALL GLAND


SIZE (MM2)
(MM)
PAIRS KG/KM DIAMETER SIZE
(MM)
(MM)
(MM)
0.5
16/0/20
2
460
16.8
20
0.5
16/0/20
5
760
20.9
25
0.5
16/0/20
10
1300
27.9
32
0.5
16/0/20
20
1870
34.3
40
0.5
16/0/20
30
2620
40.5
50S
0.5
16/0/20
50
4180
51.5
50
0.75
24/0/20
2
500
17.6
20
0.75
24/0/20
5
920
22.0
25
0.75
24/0/20
10
1610
29.5
32
0.75
24/0/20
20
2420
37.8
40
0.75
24/0/20
30
3120
43.9
50S
0.75
24/0/20
50
4910
55.0
63S
1.5
7/0/53
2
730
20.4
20
1.5
7/0/53
5
1180
25.4
25
1.5
7/0/53
10
1820
33.5
40
1.5
7/0/53
20
3030
42.6
50S
1.5
7/0/53
30
3650
50.8
50
1.5
7/0/53
50
5640
62.6
63

CLEAT
SIZE
0.7
0.9
1.2
1.4
1.6
R9
0.7
0.9
1.2
1.6
1.8
R9
0.9
1.0
1.4
1.8
R9
R10

BS5308 PART 1, TYPE 2 LS0H


Plain annealed flexible copper conductors, polyethylene insulated, laid up to form
pairs, each pair individually aluminium/mylar foil tape screened, complete with
0.5mm2 drain wire, collective aluminium/mylar foil tape screen, complete with
0.5mm2 drain wire, low smoke zero halogen (LS0H) bedding, galvanised steel wire
armour, low smoke zero halogen (LS0H) sheath, Blue or Black, generally to BS5308.
CCC CODE

CONTROL AND
INSTRUMENTATION CABLE
ARMOURED WITH
INDIVIDUAL AND
COLLECTIVE SCREEN
(0.5MM2 TO 1.5MM2)

7267
7268
7269
7270
7298
7299
7297
7296

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5

Temperature limits:
-20 to +65C.
Bending radius:
6 x overall diameter.

24/0.20
24/0.20
24/0.20
24/0.20
7/0.53
7/0.53
7/0.53
7/0.53

NO. OF
PAIRS
2
5
10
20
2
5
10
20

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
500
17.6
920
22.0
1610
29.5
2420
37.8
730
20.4
1180
25.4
1820
33.5
3030
42.6

GLAND
SIZE
(MM)
20
25
32
40
20
25
40
505

CLEAT
SIZE
(MM)
0.7
0.9
1.2
1.6
0.9
1.0
1.4
1.8

Core identification:
Part 1 colour code chart on page 62.
Part 2 colour code chart on page 63.
Should not be installed at
temperatures below 0C.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

60

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES
BS5308 PART 1, TYPE 3
Plain annealed copper conductors, polyethylene insulated, laid up to form
pairs, each pair individually aluminium/mylar foil tape screened complete
with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete
with 0.5mm2 drain wire, polyethylene bedding, lead sheathed, galvanised steel
wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame
propagation to BS4066 PT1 and IEC 332 PT1. (Bunched cables to BS4066 PT3
and IEC 332 PT3).
BS5308 PART 2, TYPE 3
Plain annealed flexible copper conductors, PVC insulated laid up to form pairs,
each pair individually aluminium/mylar foil tape screened complete with
0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete with
0.5mm2 drain wire, PVC bedding, lead sheathed, galvanised steel wire armour,
PVC outer sheath reduced propagation. Blue or Black. Flame propagation to
BS4066 PT1 and IEC 332 PT1. (Bunched cables to BS4066 PT3 and IEC 332 PT3.

CCC CODE
PT1

PT2

7821
7822
7823
7824
7825
7826
7827
7971
7972
7973
7974
7975
7976
7977
7851
7852
7853
7854
7855
7856
7857

7921
7922
7923
7924
7925
7926
7927
7951
7952
7953
7954
7955
7956
7957

Temperature limits:
-20 to +63C.
Bending radius:
5 x overall diameter.

CONDUCTOR STRANDING No. OF WEIGHT OVERALL GLAND


(MM)
PAIRS KG/KM DIAMETER SIZE
SIZE (MM2)
(MM)
(MM)
(MM)
0.75
24/0.20
1
700
15.7
20
0.75
24/0.20
2
795
16.8
20
0.75
24/0.20
5
1598
25.1
25
0.75
24/0.20
10
2280
29.4
32
0.75
24/0.20
20
3630
37.3
40
0.75
24/0.20
30
4385
43.1
50S
0.75
24/0.20
50
6895
53.1
63S
1.0
1/1.13
1
710
15.8
20
1.0
1/1.13
2
828
17.0
20
1.0
1/1.13
5
1627
25.0
25
1.0
1/1.13
10
2275
29.6
32
1.0
1/1.13
20
3149
37.6
40
1.0
1/1.13
30
4420
42.6
50S
1.0
1/1.13
50
6964
53.5
63S
1.5
7/0.53
1
940
16.9
20
1.5
7/0.53
2
1051
19.0
20
1.5
7/0.53
5
1973
27.4
32
32
33.2
2823
10
7/0.53
1.5
1.5
7/0.53
20
4498
42.1
50S
1.5
7/0.53
30
6207
50.1
50
1.5
7/0.53
50
8961
61.0
63

CLEAT
SIZE
0.7
0.7
1.0
1.2
1.6
1.8
R9
0.7
0.7
1.0
1.2
1.6
1.8
R9
0.7
0.8
1.1
1.4
1.8
2.0
R10

Core identification:
Part 1 colour code chart on page 62.
Part 2 colour code chart on page 63.
Should not be installed at
temperatures below 0C.

CONTROL AND
INSTRUMENTATION CABLE
LEAD SHEATHED
ARMOURED WITH
COLLECTIVE SCREEN
(0.75MM2 TO 1.5MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

61

BS5308 PART 1, TYPE 3


Plain annealed flexible copper conductors, polyethylene insulated, laid up to
form pairs, collective aluminium/mylar tape screen, complete with 0.5mm2
drain wire, polyethylene bedding, lead sheathed, galvanised steel wire armour,
PVC outer sheath reduced propagation. Blue or Black. Flame propagation to
BS4066 PT1 and IEC 332 PT1. (Bunched cables to BS4066 PT3 and IEC 332 PT3).
BS5308 PART 2, TYPE 3
Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs,
collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire,
PVC bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath
reduced propagation. Blue or Black. Flame propagation to BS4066 PT1 and IEC
332 PT1. (Bunched cables to BS4066 PT3 and IEC 332 PT3).
CCC CODE

CONTROL AND
INSTRUMENTATION CABLE
LEAD SHEATHED
ARMOURED WITH
INDIVIDUAL AND
COLLECTIVE SCREENS
(0.75MM2 TO 1.5MM2)

PT1

PT2

7830
7831
7832
7833
7834
7835
N/A
N/A
N/A
N/A
N/A
N/A
7870
7871
7872
7873
7874
7875

7930
7931
7932
7933
7934
7935
N/A
N/A
N/A
N/A
N/A
N/A
7970
7971
7972
7973
7974
7975

Temperature limits:
-20 to +65C.
Bending radius:
15 x overall diameter.

CONDUCTOR STRANDING No. OF WEIGHT OVERALL GLAND


SIZE (MM2)
(MM)
PAIRS KG/KM DIAMETER SIZE
(MM)
(MM)
(MM)
0.75
24/0.20
2
1280
21.5
25
0.75
24/0.20
5
1810
26.0
25
0.75
24/0.20
10
2720
32.7
32
0.75
24/0.20
20
4270
40.9
50S
0.75
24/0.20
30
6000
46.3
50S
0.75
24/0.20
50
8330
58.5
63S
1.0
1/1.13
2
1280
22.3
25
1.0
1/1.13
5
1820
27.2
25
1.0
1/1.13
10
2750
34.2
40
1.0
1/1.13
20
4350
43.8
50S
1.0
1/1.13
30
6110
51.4
50
1.0
1/1.13
50
8350
62.5
63
1.5
7/0.53
2
1680
25.5
25
1.5
7/0.53
5
2300
30.0
32
1.5
7/0.53
10
4000
40.1
50S
1.5
7/0.53
20
6300
50.2
50
1.5
7/0.53
30
8110
57.6
63S
1.5
7/0.53
50
11160
70.6
75S

CLEAT
SIZE
0.9
1.1
1.4
1.8
2.0
R10
0.9
1.1
1.4
1.8
R9
R10
1.1
1.2
1.6
2.0
R10
R12

Core identification:
Part 1 colour code chart on page 62.
Part 2 colour code chart on page 63.
Should not be installed at
temperatures below 0C.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

62

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES
BS5308 PART 1
PAIR
NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

A
WIRE
BLACK
BLACK
BLUE
BLACK
BLUE
GREEN
BLACK
BLUE
GREEN
BROWN
BLACK
BLUE
GREEN
BROWN
WHITE
BLACK
BLUE
GREEN
BROWN
WHITE
RED
BLACK
BLUE
GREEN
BROWN

B
WIRE
BLUE
GREEN
GREEN
BROWN
BROWN
BROWN
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED
ORANGE
ORANGE
ORANGE
ORANGE
ORANGE
ORANGE
YELLOW
YELLOW
YELLOW
YELLOW

PAIR
NUMBER
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50

A
WIRE
WHITE
RED
ORANGE
BLACK
BLUE
GREEN
BROWN
WHITE
RED
ORANGE
YELLOW
BLACK
BLUE
GREEN
BROWN
WHITE
RED
ORANGE
YELLOW
GREY
BLACK
BLUE
GREEN
BROWN
WHITE

B
WIRE
YELLOW
YELLOW
YELLOW
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
VIOLET
VIOLET
VIOLET
VIOLET
VIOLET
VIOLET
VIOLET
VIOLET
VIOLET
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE

For individual screened pairs, identification will be Black/Blue numbered pairs.


Two pair collectively screened cables are in quad formation colour coded in
rotation, Black, Blue, Green, Brown.
Single triple will be Black, Blue, Turquoise.

BS5308 PART 1 CORE


IDENTIFICATION
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

63

BS5308 PART 2
PAIR
NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

A
WIRE
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED
BLACK
BLACK
BLACK
BLACK
BLACK
YELLOW
YELLOW
YELLOW
YELLOW
YELLOW
WHITE/BLUE
WHITE/BLUE
WHITE/BLUE
WHITE/BLUE
WHITE/BLUE

B
WIRE
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY

PAIR
NUMBER
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50

A
WIRE
RED/BLUE
RED/BLUE
RED/BLUE
RED/BLUE
RED/BLUE
BLUE/BLACK
BLUE/BLACK
BLUE/BLACK
BLUE/BLACK
BLUE/BLACK
YELLOW/BLUE
YELLOW/BLUE
YELLOW/BLUE
YELLOW/BLUE
YELLOW/BLUE
WHITE/ORANGE
WHITE/ORANGE
WHITE/ORANGE
WHITE/ORANGE
WHITE/ORANGE
ORANGE/RED
ORANGE/RED
ORANGE/RED
ORANGE/RED
ORANGE/RED

B
WIRE
BLUE
ORANGE
GREEN
WHITE
BROWN
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY

For individual screened pairs, identification will be White/Blue numbered pairs.


Two pair collectively screened cables are in quad formation colour coded in
rotation, Blue, Green, Orange, Brown.
Single triple will be Blue, White, Green.

BS5308 PART 2 CORE


IDENTIFICATION
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

64

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES
Plain annealed flexible copper conductors, PVC bedding, tinned annealed
copper wire braid screen, PVC bedding, galvanised steel wire armour, PVC
outer sheath. Grey. 300/500 volts grade to British Steel specification CES 20
part 4, Type 134. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE

CONDUCTOR STRANDING
(MM)
SIZE (MM2)

BSC1342C
BSC1343C
BSC1344C
BSC1347C
BSC13412C
BSC13419C
BSC13427C
BSC13437C

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75

Temperature limits:
-20 to +70C.

24/0/2
24/0/2
24/0/2
24/0/2
24/0/2
24/0/2
24/0/2
24/0/2

NO. OF
CORES

2
3
4
7
12
19
27
37

WEIGHT OUTSIDE
KG/KM DIAMETER
(MM)
420
452
490
579
906
1091
1562
1872

13.4
13.8
14.4
15.9
19.5
21.5
25.5
28.1

GLAND
SIZE
(MM)

SINGLE
CLEAT

20S
20S
20S
20S
20
20
25
32

0.6
0.6
0.6
0.7
0.8
0.9
1.1
1.2

Should not be installed at


temperatures below 0C.

Bending radius:
6 x overall diameter.
CORE IDENTIFICATION:
NO. OF
CORES
2
3
4
7
12
19

27

37

COLOUR
BROWN
BLUE
BROWN
BLUE
GREEN/YLW
BROWN
GREY
GREEN/YLW
BLACK
RED
BLUE
GREEN
YELLOW
WHITE
BLACK
BROWN
RED
BLUE
GREEN
YELLOW
WHITE
BLACK
BROWN
ORANGE
PINK
TURQUOISE
GREY
VIOLET
RED
BLUE
GREEN
YELLOW
WHITE
BLACK
BROWN
VIOLET
ORANGE
PINK
TURQUOISE
GREY
RED/BLUE RED/GREEN RED/YELLOW RED/WHITE RED/BLACK RED/BROWN BLUE/YELLOW
GREEN
YELLOW
WHITE
BLACK
BROWN
BLUE
RED
PINK
TURQUOISE
GREY
RED/BLUE RED/GREEN
ORANGE
VIOLET
RED/YELLOW RED/WHITE RED/BLACK RED/BROWN BLUE/YELLOW BLUE/WHITE BLUE/BLACK
BLUE/ORANGE BLUE/GREEN BLUE./GREY GREEN/YLW GREEN/WHITE GREEN/BLACK
RED
BLUE
GREEN
YELLOW
WHITE
BLACK
BROWN
VIOLET
ORANGE
PINK
TURQUOISE
GREY
RED/BLUE RED/GREEN
RED/YELLOW RED/WHITE RED/BLACK RED/BROWN BLUE/YELLOW BLUE/WHITE BLUE/BLACK
BLUE/ORANGE BLUE/GREEN BLUE./GREY GREEN/YLW GREEN/WHITE GREEN/BLACK GRN/ORANGE
GREEN/GREY BROWN/YLW BRN/WHITE BRN/BLACK BROWN/GREY VIOLET/YLW VIOLET/BLACK
VIOLET/WHT RED/GREY

INSTRUMENTATION CABLE
TO BRITISH STEEL
SPECIFICATION
CES20 TYPE 134
(0.75MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

65

Tinned annealed flexible copper conductors, PVC insulated and laid up to form
pairs, collective aluminium/mylar foil tape screen, complete with 0.5mm2
drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath.
Orange. 300/500 volts grade.
Type 143. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
BSC1431P
BSC1432P
BSC1435P
BSC14310P
BSC14320P
BSC14330P
BSC14350P

CONDUCTOR STRANDING
(MM)
SIZE (MM2)
0.75
0.75
0.75
0.75
0.75
0.75
0.75

NO. OF
PAIRS

24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20

Temperature limits:
-20 to +70C.

1
2
5
10
20
30
50

WEIGHT OUTSIDE
KG/KM DIAMETER
(MM)
280
11.4
400
14.1
630
18.0
950
22.2
1550
28.2
2000
32.3
3200
40.6

GLAND
SIZE
(MM)
20/16
20S
20
25
32
32
50S

SINGLE
CLEAT
0.5
0.6
0.8
0.9
1.2
1.4
1.6

Should not be installed at


temperatures below 0C.

Bending radius:
6 x overall diameter.
CORE IDENTIFICATION:
PAIR
NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

A
WIRE
BLACK
BLACK
BLACK
BLACK
BLACK
BLUE
BLUE
BLUE
BLUE
BLUE
ORANGE
ORANGE
ORANGE
ORANGE
GREEN
GREEN
GREEN
BROWN
BROWN
GREY
BLACK
BLACK
BLACK
BLACK
WHITE

B
WIRE
BLUE
ORANGE
GREEN
BROWN
GREY
WHITE
ORANGE
GREEN
BROWN
GREY
WHITE
GREEN
BROWN
GREY
WHITE
BROWN
GREY
WHITE
GREY
WHITE
WHITE
RED
YELLOW
VIOLET
RED

PAIR
NUMBER
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50

A
WIRE
WHITE
WHITE
BLUE
BLUE
BLUE
GREEN
GREEN
GREEN
RED
RED
RED
RED
RED
GREY
GREY
ORANGE
ORANGE
YELLOW
YELLOW
BROWN
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE

B
WIRE
YELLOW
VIOLET
RED
YELLOW
VIOLET
RED
YELLOW
VIOLET
GREY
ORANGE
YELLOW
BROWN
VIOLET
YELLOW
VIOLET
YELLOW
VIOLET
BROWN
VIOLET
VIOLET
BLACK
BLUE
RED
ORANGE
YELLOW

INSTRUMENTATION CABLE
TO BRITISH STEEL
SPECIFICATION
CES20 TYPE 143
(0.75MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

66

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES
Solid tinned annealed copper conductors, PVC insulated, polyester taped, PVC
sheathed. To BPO CW(M) 1308. Sheath colour: White. Flame propagation to
BS4066 PT1 and IEC 332 PT1.
CCC
CODE

STRANDING
(MM2)

No. OF
PAIRS

WEIGHT
KGS/KM

13000
13001
13002
13003
13004
13005
13006
13007
13008
13009
13010
13012
13014
13016
13018
13020
13022
13023

1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50

2
3
4
6
10
10+E
12
15
20+E
25+E
30+E
40+E
50+E
60+E
80+E
100+E
160+E
320+E

18
24
35
46
70
90
80
95
146
163
200
297
356
412
552
697
1135
2306

OVERALL
DIAMETER
(MM)
4.1
4.8
5.8
6.8
8.3
8.6
9.1
9.8
12.0
11.4
12.2
15.0
17.8
20.9
22.5
24.1
30.5
39.5

GLAND
SIZE
(MM)
20/16
20/16
20/16
20/16
20/16
20S
20S
20S
20
20
20
25
25
32
32
32
40
50

Bending radius:
5 x overall diameter.

E. denotes earth core.


Temperature limits:
-20 to +70C.

Should not be installed at


temperatures below 0C.

CORE IDENTIFICATION:
PAIR
NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

A
B
WIRE
WIRE
WHITE/BLUE BLUE/WHITE
WHITE/ORANGE ORANGE/WHITE
WHITE/GREEN GREEN/WHITE
WHITE/BROWN BROWN/WHITE
GREY/WHITE
WHITE/GREY
RED/BLUE
BLUE/RED
RED/ORANGE ORANGE/RED
GREEN/RED
RED/GREEN
RED/BROWN BROWN/RED
RED/GREY
GREY/RED
BLACK/BLUE
BLUE/BLACK
BLACK/ORANGE ORANGE/BLACK
BLACK/GREEN GREEN/BLACK
BLACK/BROWN BROWN/BLACK
BLACK/GREY
GREY/BLACK

PAIR
NUMBER
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

A
B
WIRE
WIRE
YELLOW/BLUE BLUE/YELLOW
YELLOW/ORANGE ORANGE/YELLOW
YELLOW/GREEN GREEN/YELLOW
YELLOW/BROWN BROWN/YELLOW
YELLOW/GREY GREY/YELLOW
VIOLET/BLUE BLUE/VIOLET
VIOLET/ORANGE ORANGE/VIOLET
VIOLET/GREEN GREEN/VIOLET
VIOLET/BROWN BROWN/VIOLET
VIOLET/GREY GREY/VIOLET
PINK/BLUE
BLUE/PINK
PINK/ORANGE ORANGE/PINK
PINK/GREEN
GREEN/PINK
PINK/BROWN BROWN/PINK
PINK/GREY
GREY/PINK

Solid plain annealed copper conductors, cellular polyethylene insulated,


Petroleum jelly filled, PE outer sheath. Black. To CW1128A. Flame propagation
to BS4066 PT1 and IEC 332 PT1.

INTERNAL TELEPHONE
CABLE TYPE CW1308

CCC
CODE

STRANDING
(MM)

No. OF
PAIRS

WEIGHT
KG/KM

OUTSIDE
DIAMETER

13030
13031
13032
13034
13035

1/0.50
1/0.50
1/0.50
1/0.50
1/0.50

5
10
20
50
100

76
113
154
381
710

7.8
9.1
11.3
15.5
20.7

GLAND
SIZE
(MM)
20/16
20S
20
25
32

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

67

Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs,
PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ESI 09-6:
Issue 5 Section 3.6. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
13050
13051
13052
13053
13054
13055
13056

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.28
0.28
0.28
0.28
0.28
0.28
0.28

NO. OF
PAIRS

1/0.6
1/0.6
1/0.6
1/0.6
1/0.6
1/0.6
1/0.6

*2
5
10
20
30
50
100

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
145
8.0
221
10.0
314
12.3
463
15.0
697
18.0
977
21.8
1793
29.9

GLAND
SIZE
(MM)
20/16
20/16
20/16
20S
20
25
32

CLEAT
SIZE
SINGLE
0.4
0.4
0.6
0.6
0.8
0.9
1.2

Core identification:
See colour chart on page 69.

* 2 pair laid up in quad formation.


Temperature limits:
-20 to +70C.

Should not be installed at


temperatures below 0C.

Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, PVC bedding,
galvanised steel wire armour, PVC outer sheath. Black. To ESI 09-6: Issue 5 Section 3.6.
Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
13081
13083
13084
13085
13086
13087
13088
13089
13090
13091

CONDUCTOR STRANDING
(MM)
SIZE (MM2)
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63

NO. OF
PAIRS

1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9

*2
5
10
15
20
25
30
40
50
60
75
100

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
250
10.1
350
14.1
650
18.6
800
21.0
1000
22.7
1250
25.4
1400
26.7
1700
29.3
2000
32.6
2690
36.6
2900
38.4
3650
44.1

GLAND
SIZE
(MM)
20/16
20S
20
25
25
25
25
32
32
40
40
50S

CLEAT
SIZE
SINGLE
0.5
0.6
0.8
0.9
0.9
1.0
1.1
1.2
1.4
1.6
1.6
1.8

Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs,
collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire,
PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ESI 09-6:
Issue 5 Section 3.6. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
13101
13103
13104
13105
13106
13107
13108
13109
13110
-

PVC INSULATED
MULTIPAIR ARMOURED
CABLE TO ESI
STANDARD

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63

NO. OF
PAIRS

1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9

* 2 pair laid up in quad formation.


Temperature limits:
-20 to +70C.
Bending radius: 6 x overall diameter.

*2
5
10
15
20
25
30
40
50
100

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
258
11.0
445
15.3
735
19.2
908
21.4
1046
23.1
1750
25.8
1512
27.1
1804
30.2
2166
33.6
3870
45.4

GLAND
SIZE
(MM)
20/16
20S
20
25
25
25
32
32
40
50S

CLEAT
SIZE
SINGLE
0.5
0.6
0.8
0.9
1.2
1.2
1.2
1.2
1.4
2.0

Core identification:
See colour chart on page 69.
Should not be installed at
temperatures below 0C.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

68

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES
Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs,
PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ESI 096: Issue 6 Section 4.5. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
13381
13383
13384
13385
13386
13387
13388
13389
13390
13391

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5

NO. OF
PAIRS

1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8

*2
5
10
15
20
25
30
40
50
100

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
200
9.5
290
13.1
450
17.0
630
18.9
770
20.5
1159
23.2
1110
26.2
1450
31.8
1770
33.4
3000
43.4

GLAND
SIZE
(MM)
20/16
20S
20
20
20
25
25
32
40
50S

CLEAT
SIZE
SINGLE
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.4
1.4
1.8

Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs,
collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire,
PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ESI 096: Section 4.5. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE

PVC INSULATED
MULTIPAIR ARMOURED
CABLE TO ESI
STANDARD

13401
13403
13404
13405
13406
13407
13408
13409
13410
13411

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5

NO. OF
PAIRS

1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8

*2
5
10
15
20
25
30
40
50
100

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
260
10.9
380
14.1
660
17.8
795
19.4
900
21.1
1159
23.5
1380
27.1
1800
33.0
2220
34.9
3041
44.7

GLAND
SIZE
(MM)
20/16
20S
20
20
25
25
32
32
40
50S

CLEAT
SIZE
SINGLE
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.4
1.4
1.8

Solid tinned annealed copper, polyethylene insulated, low smoke and zero
halogen (LS0H) bedding, galvanised steel wire armour, low smoke and zero
halogen (LS0H) sheath. Black. Generally to ESI 09-6: Issue 6 Section 4.5.
CCC
CODE
13501
13503
13504
13506

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.5
0.5
0.5
0.5

NO. OF
PAIRS

1/0.8
1/0.8
1/0.8
1/0.8

*2
5
10
20

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
200
9.5
290
13.1
450
17.0
770
20.5

GLAND
SIZE
(MM)
20/16
20S
20
20

CLEAT
SIZE
SINGLE
0.5
0.6
0.7
0.9

Solid tinned, annealed copper conductors, polyethylene insulated, twisted to form


pairs, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain, wire,
low smoke zero halogen (LS0H) bedding, galvanised steel wire armour, low smoke
and zero halogen (LS0H) sheath. Black. Generally to ESI 09-6: Issue 6 Section 4.5.
CCC
CODE
13601
13603
13604
13606

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.5
0.5
0.5
0.5

NO. OF
PAIRS

1/0.8
1/0.8
1/0.8
1/0.8

* 2 pair laid up in quad formation.


Temperature limits:
-20 to +70C.
Bending radius: 8 x overall diameter.

*2
5
10
20

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
260
10.9
380
14.1
660
17.8
900
21.1

GLAND
SIZE
(MM)
20/16
20S
20
25

CLEAT
SIZE
SINGLE
0.5
0.6
0.7
0.9

Core identification:
See colour chart on page 70.
Should not be installed at
temperatures below 0C.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

69

ESI 09-6 SECTION 3


PAIR
NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

A
WIRE
BLACK
BLACK
BLACK
BLACK
BLACK
BLUE
BLUE
BLUE
BLUE
BLUE
ORANGE
ORANGE
ORANGE
ORANGE
GREEN
GREEN
GREEN
BROWN
BROWN
GREY
BLACK
BLACK
BLACK
BLACK
WHITE

B
WIRE
BLUE
ORANGE
GREEN
BROWN
GREY
WHITE
ORANGE
GREEN
BROWN
GREY
WHITE
GREEN
BROWN
GREY
WHITE
BROWN
GREY
WHITE
GREY
WHITE
WHITE
RED
YELLOW
VIOLET
RED

PAIR
NUMBER
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50

A
WIRE
WHITE
WHITE
BLUE
BLUE
BLUE
GREEN
GREEN
GREEN
RED
RED
RED
RED
RED
GREY
GREY
ORANGE
ORANGE
YELLOW
YELLOW
BROWN
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE

B
WIRE
YELLOW
VIOLET
RED
YELLOW
VIOLET
RED
YELLOW
VIOLET
GREY
ORANGE
YELLOW
BROWN
VIOLET
YELLOW
VIOLET
YELLOW
VIOLET
BROWN
VIOLET
VIOLET
BLACK
BLUE
RED
ORANGE
YELLOW

All two pair cables are in quad formation and colour coded in rotation - Blue,
Orange, Green, Brown.

PAIR
NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

COLOUR
WIRE A
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED
BLACK
BLACK
BLACK
BLACK
BLACK
YELLOW
YELLOW
YELLOW
YELLOW
YELLOW

WIRE B
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY

2 pair (quad) cables - white, red, blue


and orange
(in order of rotation)

ESI 09-6
SECTION 3.6
CORE IDENTIFICATION
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

70

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES
ESI 09-6 SECTION 4
PAIR
NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

A
WIRE
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED
BLACK
BLACK
BLACK
BLACK
BLACK
YELLOW
YELLOW
YELLOW
YELLOW
YELLOW

B
WIRE
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY

All two pair cables are in quad


formation and colour coded in
rotation - White, Red, Blue, Orange.

ESI 09-6
SECTION 4.5
CORE IDENTIFICATION

For 30 pair cables the formation will


be 3 X 10 pair units numbered - 1, 2
and 3.

For 40 pair cables the formation will be


2 X 20 pair units numbered - 1 and 2.
For 50 pair cables the formation will
be 5 X 10 pair units numbered - 1, 2
3, 4 and 5.

Each unit is lapped with coloured tape for identification as follows

UNIT 1
UNIT 2
UNIT 3
UNIT 4
UNIT 5

BLUE
ORANGE
GREEN
BROWN
GREY

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

71

Solid plain annealed copper conductors, cellular polyethylene insulated, petroleum


jelly filled, collective aluminium/mylar tape screen plus 0.5mm2 drain wire,
polyethylene bedding, galvanised steel wire armour, PVC outer sheath. Black. To
BS3573 and CW1128/1198. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
13150
13151
13153
13154

CONDUCTOR STRANDING
(MM)
SIZE (MM2)
0.63
0.63
0.63
0.63

NO. OF
PAIRS

1/0.9
1/0.9
1/0.9
1/0.9

5
10
20
50

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
(MM)
392
16.7
620
19.9
1078
24.8
2155
34.5

GLAND
SIZE
SINGLE
20
20
25
40

CLEAT
SIZE
0.7
0.8
1.0
1.6

Solid plain annealed copper conductors, cellular polyethylene insulated,


petroleum jelly filled solid polyethylene bedding, galvanised steel wire armour,
PE outer sheath. Black.
To BPO CW 1128A/1198A. (Concentric construction). Flame propagation to
BS4066 PT1 and IEC 332 PT1.
CCC
CODE
13040
13041
13042
13043
13044

CONDUCTOR STRANDING
(MM)
SIZE (MM2)
0.196
0.196
0.196
0.196
0.196

NO. OF
PAIRS

1/0.5
1/0.5
1/0.5
1/0.5
1/0.5

5
10
20
50
100

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
(MM)
470
11.78
721
12.30
1204
14.78
2347
22.78
3660
29.77

GLAND
SIZE
SINGLE
20/16
20S
20S
25
32

CLEAT
SIZE
0.5
0.5
0.6
0.9
1.2

COLOUR SCHEME FOR BS3573 - UNIT CONSTRUCTION


PAIR
NUMBER
1
2
3
4
5
6
7
8
9
10

A
WIRE
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED

B
WIRE
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY

UNIT 1
UNIT 2
UNIT 3
UNIT 4
UNIT 5

BLUE
ORANGE
GREEN
BROWN
GREY

If sub-units are used binders for


corresponding sub-units shall be the
same colour.

Cables may be manufactured using 5pair sub-units coloured as 1-5 and 6-10

PETROLEUM
JELLY FILLED TELEMETRY
CABLE TO BS3573 AND
CW1128/1198
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

72

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES
Tinned annealed flexible copper conductors, PVC insulated, non-hygroscopic binder
tape, tinned annealed copper wire braid screen, PVC outer sheath. Black. 440 volts
grade. To Ministry of Defence Standard DEF 61-12 (Part 4 for 7/0.2 conductors, Part
5 for 16/0.2 conductors). Flame propogation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
722C
723C
724C
726C
728C
7212C
7218C
7225C
7236C
7250C
7260C
1622C
1623C
1624C
1626C
1628C
16210C
16212C
16218C
16225C
16236C
16250C
16260C

CONDUCTOR STRANDING
(MM2)
SIZE (MM2)
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50

7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
6
8
12
18
25
36
50
60
2
3
4
6
8
*10
12
18
25
36
50
60

23
27
32
55
69
83
110
150
200
270
310
69
79
92
120
146
190
198
250
320
450
564
670

OVERALL
DIAMETER
(MM)
4.1
4.3
4.6
5.9
6.0
7.2
8.5
9.8
11.2
13.0
13.8
6.9
7.2
7.7
8.7
8.9
11.8
11.0
12.5
14.6
16.7
18.5
20.3

GLAND
SIZE
(MM)
16
16
16
16
16
16
20
20
20
25
25
16
16
16
20
20
20
20
20
25
25
32
32

Tinned annealed flexible copper conductors, low smoke and zero halogen
(LS0H) insulation, non-hygroscopic binder tape, tinned annealed copper wire
braid screen, low smoke and zero halogen (LS0H) outer sheath. Black. 440 volt
grade. Generally to ministry of Defence Standard DEF61-12 Part 5 LSF.
CCC
CODE
LSF1622C
LSF1623C
LSF1624C
LSF1626C
LSF16212C
LSF16218C
LSF16225C

CONDUCTOR STRANDING
SIZE (MM2)
(MM2)
0.50
0.5
0.5
0.5
0.5
0.5
0.5

16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20

* Laid up in a pair configuration.


Temperature limits:
-55 to +70C.
Bending radius:
6 x overall diameter.

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
6
12
18
25

69
79
92
120
198
250
320

OVERALL
DIAMETER
(MM)
6.9
7.2
7.7
8.7
11.0
12.5
14.6

GLAND
SIZE
(MM)
16
16
16
20
20
20
25

Core identification:
See colour chart on page 73.
Should not be installed at
temperatures below 0C.

DEFENCE
STANDARD SCREENED
MULTICORE
CABLE C TYPE
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

73

COLOUR CODES
CORE
NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
35
36

COLOUR
RED
BLUE
GREEN
YELLOW
WHITE
BLACK
BROWN
VIOLET
ORANGE
PINK
TURQUOISE
GREY
RED/BLUE
GREEN/RED
YELLOW/RED
WHITE/RED
RED/BLACK
YELLOW/BLUE
YELLOW/BLUE
WHITE/BLUE
BLUE/BLACK
ORANGE/BLUE
GREEN/BLUE
GREY/BLUE
YELLOW/GREEN
WHITE/GREEN
GREEN/BLACK
ORANGE/GREEN
GREY/GREEN
YELLOW/BROWN
WHITE/BROWN
BROWN/BLACK
GREY/BROWN
YELLOW/VIOLET
VIOLET/BLACK
VIOLET/BLACK
WHITE/VIOLET

Where 2 colours are shown the core


is striped e.g. Red/Blue - the core is
striped Red with Blue.

DEFENCE
STANDARD 61-12
PARTS 4 & 5 CORE
IDENTIFICATION
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

74

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES
NON-ARMOURED
Plain annealed flexible conductors, PVC insulated, laid up to form pairs,
collective aluminium mylar foil tape screen, complete with 0.5mm2 drain
wire, PVC outer sheath.
Thermocouple wires calibrated to BS4937, ANSI 96.1 and IEC 584.3.
Flame propagation to BS4066 PT1 and IEC 332 PT1.
NO OF
PAIRS

SIZE
(MM2)

1
2
5
10
20

0.75
0.75
0.75
0.75
0.75

STRANDING OVERALL
(MM)
DIAMETER
(MM)
24/0.20
6.7
24/0.20
7.7
24/0.20
13.7
24/0.20
18.1
24/0.20
23.9

GLAND
SIZE
(MM)
20/16
20/16
25
25
32

JX CCC KCB CCC


CODE
CODE
(WAS VX)
7500
7530
7501
7531
7503
7533
7505
7537
7507
7539

KX CCC TX CCC
CODE
CODE
7570
7571
7573
7575
7577

Temperature limits:
-30 to +105C.

Core identification:
See colour chart on page 77.

Bending radius:
5 x overall diameter.

Should not be installed at


temperatures below 0C.

7550
7551
7553
7557
7559

ARMOURED
Plain annealed flexible conductors, PVC insulated, laid up to form pairs,
collective aluminium mylar foil tape screen, complete with 0.5mm2 drain
wire, PVC bedding, galvanised steel wire armour, PVC outer sheath.
Thermocouple wires calibrated to BS4937, ANSI 96.1 and IEC 584.3.
Flame propagation to BS4066 PT1 and IEC 332 PT1.
NO OF
PAIRS

SIZE
(MM2)

1
2
5
10
20

0.75
0.75
0.75
0.75
0.75

STRANDING OVERALL
(MM)
DIAMETER
(MM)
24/0.20
11.1
24/0.20
12.3
24/0.20
19.2
24/0.20
24.7
30.7
24/0.20

GLAND
SIZE
(MM)
20/16
20/16
20
25
32

JX CCC KCB CCC


CODE
CODE
(WAS VX)
7600
7640
7601
7641
7603
7643
7605
7645
7607
7647

KX CCC TX CCC
CODE
CODE
7700
7701
7703
7705
7707

Temperature limits:
-30 to +105C.

Core identification:
See colour chart on page 77.

Bending radius:
6 x overall diameter.

Should not be installed at


temperatures below 0C.

PVC INSULATED
COLLECTIVE SCREENED
THERMOCOUPLE
EXTENSION AND
COMPENSATING CABLE
(0.75MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

7660
7661
7663
7665
7667

75

TRAFFIC CONTROL CABLE


Plain annealed solid conductors, PVC insulated, PVC bedding, galvanised steel
wire armour, PVC outer sheath, colour orange, generally to BS6346/87
CCC
CODE
TRAF4X1
TRAF8X1
TRAF12X1
TRAF16X1
TRAF20X1
TRAF4X1/5
TRAF8X1/5
TRAF12X1/5
TRAF16X1/5
TRAF20X1/5
TRAF8X1E

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.0

NO. OF
CORES

WEIGHT
KG/KM

4
8
12
16
20
4
8
12
16
20
8

325
413
567
774
905
363
534
704
836
1040
533

1/1.13
1/1.13
1/1.13
1/1.13
1/1.13
1/1.38
1/1.38
1/1.38
1/1.38
1/1.38
1/1.13

Temperature limits:
-15 to +70C.

PVC INSULATED
ARMOURED
TRAFFIC SIGNAL CABLE,
LOOP FEEDER CABLE
AND LOOP
DETECTOR CABLE

Core identification:
4 core - Red, White, Blue, Black.
8 core - Red, White, Blue, Black, Green,
Yellow, Brown, Orange.
12 core - Red, White, Blue, Black,
Green, Yellow, Brown, Orange, Grey,
Violet, White/Red, Blue/Red.
16 core - Red, White, Blue, Black,
Green, Yellow, Brown, Orange, Grey,

OVERALL
DIAMETER
(MM)
13.3
15.6
17.9
19.9
22.0
12.5
15.8
18.5
20.0
21.5
16.3

GLAND
SIZE
(MM)
20S
20S
20
20
25
20S
20
20
20
25
20

Violet, White/Red, Blue/Red,


Black/Red, Grey/Red, Yellow/Red,
Brown/Red.
20 core - Red, White, Blue, Black,
Green, Yellow, Brown, Orange, Grey,
Violet, White/Red, Blue/Red,
Black/Red, Grey/Red, Yellow/Red,
Brown/Red, Green/Red, Orange/Red,
Violet/Red, Blue/White.
Should not be installed at
temperatures below 0C.

TRAFFIC CONTROL CABLE UNARMOURED


Plain annealed solid conductors, PVC insulated, PVC sheathed, colour orange,
generally to BS6346/87, 600/1000v grade.
CCC
CODE
TRAF8X1NA
TRAF12X1NA

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.0
1.0

1/1.13
1/1.13

NO. OF
CORES

WEIGHT
KG/KM

8
12

218
305

OVERALL
DIAMETER
(MM)
12.6
13.5

GLAND
SIZE
(MM)
20
25

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

76

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES
LOOP FEEDER ARMOURED CABLE
Plain annealed solid conductors, polythene insulated, polythene bedding,
galvanised steel wire armour, polythene outer sheath. Generally to BS6346/87.
Outer sheath colour: Orange. 600/1000 volts grade.
CCC
CODE
LOOP2X1/5SWA
LOOP4X1/5SWA
LOOP2X2/5SWA
LOOP4X2/5SWA

CONDUCTOR STRANDING
(MM)
SIZE (MM2)
1.5
1.5
2.5
2.5

1/1.38
1/1.38
1/1.78
1/1.78

NO. OF
CORES

WEIGHT
KG/KM

2 (1pr)
4 (2pr)
2 (1pr)
4 (2pr)

235
300
279
383

Temperature limits:
-15 to +70C.

OVERALL
DIAMETER
(MM)
11.8
12.7
12.5
15.0

GLAND
SIZE
(MM)
20S
20S
20S
20

Core identification:
2 core - Brown, Blue
4 core - Brown, Black, Grey, Blue.

Bending radius:
6 x overall diameter.

Should not be installed at


temperatures below 0C.

LOOP FEEDER CABLE


Plain annealed solid conductors, polyethylene insulated, polyethylene outer
sheath, colour orange, 600/1000v grade.
CCC
CODE
LOOP2X2/5
LOOP4X2/5

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
2.5
2.5

1/1.78
1/1.78

NO. OF
CORES

WEIGHT
KG/KM

2 (1pr)
4 (2pr)

10.4
16.0

Temperature limits:
-15 to +70C.

OVERALL
DIAMETER
(MM)
9.3
10.7

GLAND
SIZE
(MM)
20S
20S

Core identification:
2 core - Brown, Blue
4 core - Brown, Black, Grey, Blue.

Bending radius:
6 x overall diameter.

Should not be installed at


temperatures below 0C.

LOOP DETECTOR CABLE


Tinned flexible copper conductor, ethylene propylene rubber insulated (EPR),
polychloroprene sheathed (PCP), 600/100v generally to BS6500 + BS6195,
sheath colour black.
CCC
CODE
LOOP1/5
LOOP2/5

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
2.5

30/.025
50/0.25

Temperature limits:
-30 to +85C.

NO. OF
CORES

WEIGHT
KG/KM

1
1

53.8
64.0

OVERALL
DIAMETER
(MM)
7.0
7.9

GLAND
SIZE
(MM)
20S
20S

Should not be installed at


temperatures below -25C.

Bending radius: 6 x overall diameter.

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

77

EX

JX

KX

NX

TX

UX

VX

+-

+-

+-

+-

+-

+-

+-

CODE

BRITISH
BS1843: 1952

+-

+-

+-

+-

+-

+-

+-

AMERICAN
ANSI

+-

+-

+-

+-

+-

GERMAN
DIN

+-

+-

+-

+-

RC/SC

KCB

+-

+-

IEC 584-3

+-

COLOUR CODING OF
THERMOCOUPLE
EXTENSION AND
COMPENSATING CABLE

+-

+-

+-

+-

+-

IEC 584-3
INTRINSICALLY
SAFE
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

INSTRUMENTATION, CONTROL AND


COMMUNICATION CABLES

78

79

RAILWAY CABLES

RAILWAY CABLES

RAILWAY CABLES

80

RAILWAY CABLES
SIGNALLING CABLES
Stranded or flexible tinned copper conductors to BS6360, EPR insulated to BS7655 for
types B1, LSZH insulated for types A1, A2, A3. PCP sheath for types A1 & B1, LSZH
sheath for types A2 & A3. Manufactured to Railtrack specification RT/E/PS/00005.
CCC
CODE

RAIL
CODE

A11X/75BR
A11X/75RD
A11X/75OR
A11X/75GY
A11X/75VIR
A11X/75BK
A11X115BK
A21X/75
A21X115
A32X/75
A34X/75
A36X/75
A310X/75
A314X/75
A336X/75
A348X/75
B11X2/5
B11X10
B11X35
B22X1/5
B22X2/5
B22X10
B22X16
B22X35
B22X70
B22X95
B24X/75
B24X1/5
B24X2/5
B27X/75
B27X1/5
B27X2/5
B210X/75
B210X1/5
B210X2/5
B212X/75
B26PX/75
B212X1/5
B212X2/5
B219X/75
B219X1/5
B219X2/5
B227X/75
B227X1/5
B227X2/5
B237X/75
B237X1/5
B237X2/5
B248X/75
B248X1/5
B248X2/5

6/120002
6/120003
6/120004
6/120005
6/120006
6/120007
6/120008
6/120020
6/120024
6/120040
6/120041
6/120042
6/120043
6/120044
6/120045
6/120046
6/120061
6/120062
6/120063
6/120081
6/120082
6/120083
6/120113
6/120084
6/120085
6/120086
6/120087
6/120088
6/120089
6/120090
6/120091
6/120092
6/120093
6/120094
6/120095
6/120096
6/120111
6/120097
6/120098
6/120099
6/120100
6/120101
6/120102
6/120103
6/120104
6/120105
6/120106
6/120107
6/120108
6/120109
6/120110

RAIL
TYPE

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND


SIZE
CORES (KG/KM) DIAMETER SIZE
(MM2)
A1 Brown
0.75
7/0.37
1
16
2.95
N/A
A1 Red
0.75
7/0.37
1
16
2.95
N/A
A1 Orange
0.75
7/0.37
1
16
2.95
N/A
A1 Grey
0.75
7/0.37
1
16
2.95
N/A
A1 Violet
0.75
7/0.37
1
16
2.95
N/A
A1 Black
0.75
7/0.37
1
16
2.95
N/A
A1 Black
1.15 16/0.30
1
20
3.25
N/A
A2
0.75
7/0.37
1
30
4.50
N/A
A2
1.15 16/0.30
1
35
4.80
20/16
A3
0.75
7/0.37
2
67
7.75
20/16
A3
0.75
7/0.37
4
108
9.20
20S
A3
0.75
7/0.37
6
160
11.10
20S
A3
0.75
7/0.37
10
259
14.35
25
A3
0.75
7/0.37
14
495
15.75
25
A3
0.75
7/0.37
36
752
24.20
32
A3
0.75
7/0.37
48
963
27.50
40
B1
2.5
7/0.67
1
34
8.05
20/16
B1
10
7/1.35
1
205
10.60
20S
B1
35
19/1.53
1
495
14.50
25
B2
1.5
7/0.53
2
135
10.75
20S
B2
2.5
7/0.67
2
17
11.80
20
B2
10
7/1.35
2
443
16.85
25
B2
16
7/1.70
2
625
18.80
25
B2
35
19/1.53
2
1232
25.05
32
B2
70
19/2.14
2
2043
64.80
75
B2
95
19/2.52
2
2945
74.70
90
B2
0.75
7/0.37
4
150
11.50
20S
B2
1.5
7/0.53
4
220
12.30
20
B2
2.5
7/0.67
4
295
13.35
20
B2
0.75
7/0.37
7
225
13.25
20
B2
1.5
7/0.53
7
370
14.20
25
B2
2.5
7/0.67
7
500
15.50
25
B2
0.75
7/0.37
10
280
16.20
25
B2
1.5
7/0.53
10
401
17.50
25
B2
2.5
7/0.67
10
680
19.20
25
B2
0.75
7/0.37
12
321
16.65
25
B2
0.75
7/0.37
6pr
469
22.15
32
B2
1.5
7/0.53
12
410
18.00
25
2.5
7/0.67
12
730
19.80
25
B2
B2
0.75
7/0.37
19
425
19.15
25
B2
1.5
7/0.53
19
615
20.80
32
22.95
32
815
19
7/0.67
2.5
B2
B2
0.75
7/0.37
27
606
22.60
32
B2
1.5
7/0.53
27
897
25.00
32
B2
2.5
7/0.67
27
1200
27.65
40
B2
0.75
7/0.37
37
786
22.60
32
B2
1.5
7/0.53
37
1126
28.25
40
B2
2.5
7/0.67
37
1600
31.25
40
B2
0.75
7/0.37
48
972
28.95
40
B2
1.5
7/0.53
48
1280
31.60
40
1960
35.10
50S
48
7/0.67
2.5
B2

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

81

SIGNALLING CABLES
CCC
CODE

RAIL
CODE

RAIL
TYPE

C1X2/5
C22X2/5
C24X2/5
C27X2/5
C210X2/5
C212X2/5
C216X2/5
C3TPWS
D11X/75
D11X1/5
D11X2/5
D11X10
D11X35
D22X1/5
D22X2/5
D22X10
D22X35
D227X/75
D227X1/5
D227X2/5
D237X/75
D237X1/5
D237X2/5
D248X/75
D248X1/5
D248X2/5
E11X2/5
E22X2/5
E24X2/5
E27X2/5
E210X2/5
E212X2/5
E3TPWS

6/120130
6/120140
6/120141
6/120142
6/120143
6/120144
6/160145
6/160086
6/120211
6/120212
6/120213
6/120214
6/120215
6/120216
6/120217
6/120218
6/120219
6/120238
6/120239

C1
C2
C2
C2
C2
C2
C2
C3TPWS
D1
D1
D1
D1
D1
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
E1
E2
E2
E2
E2
E2
E3TPWS

6/120241
6/120242
6/120244
6/120245
6/120246
6/120172
6/120170
6/120171
6/120173
6/120174
6/120175
6/160090

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND


SIZE
CORES (KG/KM) DIAMETER SIZE
(MM2)
2.5
50/0.25
1
174
12.60
25
2.5
50/0.25
2
342
16.85
25
2.5
50/0.25
4
445
18.65
25
2.5
50/0.25
7
590
42.40
50
2.5
50/0.25
10
784
25.55
40
2.5
50/0.25
12
868
26.25
40
2.5
50/0.25
16
980
28.65
40
2.5
50/0.25
1pr
250
17.50
25
0.75
7/0.37
1
25
7.30
20/16
1.5
7/0.53
1
30
7.65
20/16
2.5
7/0.67
1
34
8.05
20/16
10
7/1.35
1
205
10.60
20S
35
19/1.53
1
495
14.50
25
1.5
7/0.53
2
135
10.75
20S
2.5
7/0.67
2
170
11.80
20
10
7/1.35
2
443
16.85
25
35
19/1.53
2
1232
25.05
40
0.75
7/0.37
27
606
22.60
32
1.5
7/0.53
27
897
25.00
32
2.5
7/0.67
27
1200
27.65
40
0.75
7/0.37
37
786
25.55
32
1.5
7/0.53
37
1126
28.25
40
2.5
7/0.67
37
1600
31.25
40
0.75
7/0.37
48
972
28.95
40
1.5
7/0.53
48
1280
31.60
40
2.5
7/0.67
48
1960
35.10
50S
2.5
50/0.25
1
174
12.60
20
2.5
50/0.25
2
342
16.85
25
2.5
50/0.25
4
445
18.65
25
2.5
50/0.25
7
590
21.20
32
2.5
50/0.25
10
784
25.55
32
2.5
50/0.25
12
868
26.25
40
2.5
50/0.25
1pr
250
17.50
25

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

RAILWAY CABLES

RAILWAY CABLES

RAILWAY CABLES

82

RAILWAY CABLES
POWER CABLES
Solid plain aluminium sectoral conductors XLPE insulated, PVC outer sheath,
Black to BR800 06/142639. 600/1000 volts grade to BS 5467.
CCC
CODE

RAIL
CODE

SAC2X16NA
SAC2X25NA
SAC2X35NA
SAC2X50NA
SAC2X70NA
SAC2X95NA
SAC4X70NA

6/142419
6/142519
6/142609
6/142629
6/142639
6/142644
6/151469

CONDUCTOR STRANDING
SIZE
(MM2)
16
25
35
50
70
95
70

NO. OF
CORES
2
2
2
2
2
2
4

WEIGHT OVERALL
(KG/KM) DIAMETER
420
455
525
620
840
1020
1750

GLAND
SIZE

14.30
16.60
18.00
20.40
22.80
26.20
30.60

25
25
25
32
32
40
40

TRACK FEEDER CABLES


Uncompacted circular stranded aluminium to BS6360 or uncompacted circular
stranded tinned copper to BS6360. CSP sheathed type RS4 to BS6899, black.
CCC
CODE

RAIL
CODE

POLARITY

TRACK150
TRACK161
TRACK240
TRACK500
TRACK500CU
TRACK630CU
TRACK800
TRACK1000

6/116601
6/132340
6/132990
6/132840
6/132992
6/116612
6/132991
6/116610

NEGATIVE
NEGATIVE
NEGATIVE
POSITIVE
NEGATIVE
POSITIVE
NEGATIVE
POSITIVE

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND


SIZE
CORES (KG/KM) DIAMETER SIZE
(MM2)
150 AL 37/2.25
1
540
19.40
25
161 CU 91/1.53
1
1887
24.80
32
240 AL 61/2.25
1
1076
28.30
40
500 AL 61/3.20
1
2245
40.20
50
500 CU 91/2.65
1
5291
40.60
50
630 CU 127/2.52
1
6692
44.20
63S
800 AL 127/2.85
1
3255
48.50
63S
1000 AL 127/3.20
1
3943
53.00
63

Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

83

MARINE AND OFFSHORE CABLES

MARINE AND
OFFSHORE CABLES

MARINE AND OFFSHORE CABLES

84

MARINE AND OFFSHORE CABLES


Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR)
insulated, low smoke, zero halogen (LSOH) outer sheath. Black. 600/1000 volts
grade to BS6883 and IEC 92-3.
CCC
CODE
6571TQ1/5
6572TQ1/5
6573TQ1/5
6574TQ1/5
6575TQ1/5
6576TQ1/5
6577TQ1/5
6578TQ1/5
6570/10TQ1/5
6570/12TQ1/5
6570/19TQ1/5
6570/27TQ1/5
6570/30TQ1/5
6570/37TQ1/5
6571TQ2/5
6572TQ2/5
6573TQ2/5
6574TQ2/5
6575TQ2/5
6576TQ2/5
6577TQ2/5
6578TQ2/5
6570/10TQ2/5
6570/12TQ2/5
6570/19TQ2/5
6570/27TQ2/5
6570/30TQ2/5
6570/37TQ2/5
6571TQ4
6572TQ4
6573TQ4
6574TQ4
6575TQ4
6577TQ4
6571TQ6
6572TQ6
6573TQ6
6574TQ6

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0

7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/1.04
7/1.04
7/1.04
7/1.04

Core identification:
White with Black numbers.

NO. OF
CORES

WEIGHT
KG/KM

1
2
3
4
5
6
7
8
10
12
19
27
30
37
1
2
3
4
5
6
7
8
10
12
19
27
30
37
1
2
3
4
5
7
1
2
3
4

49
125
150
180
190
240
275
295
360
440
740
970
1015
1220
63
160
190
240
280
470
355
398
519
650
860
1220
1270
1610
90
240
280
360
425
530
115
305
370
475

OVERALL
DIAMETER
(MM)
5.5
8.9
9.4
10.3
11.0
12.2
12.5
13.3
16.2
16.4
19.3
23.5
24.3
26.0
6.0
9.8
10.4
11.4
12.6
16.9
13.7
15.3
17.7
18.3
21.7
26.3
27.1
29.5
6.9
12.0
12.7
13.9
15.3
17.7
7.5
13.1
13.9
15.4

GLAND
SIZE
(MM)
20/16
20S
20S
20S
20S
20
20
25
25
25
32
32
32
40
20/16
20S
20S
20
20
25
25
25
25
25
32
40
40
40
20/16
20
20
25
25
25
20/16
20
25
25

Should not be installed at


temperatures below -15C.

Single cores available in either Black


or Green/Yellow outer sheath.

EPR INSULATED
NON-ARMOURED
SHIPWIRING CABLE
(1.5MM2 TO 6MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

85

Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR)


insulated, low smoke, zero halogen (LSOH) outer sheath. Black. 600/1000 volts
grade to BS6883 type SW4 and IEC 92-3.
CCC
CODE
6571TQ10
6572TQ10
6573TQ10
6574TQ10
6571TQ16
6572TQ16
6573TQ16
6574TQ16
6571TQ25
6572TQ25
6573TQ25
6574TQ25
6571TQ35
6572TQ35
6573TQ35
6574TQ35
6571TQ50
6572TQ50
6573TQ50
6574TQ50
6571TQ70
6573TQ70
6574TQ70
6571TQ95
6573TQ95
6574TQ95
6571TQ120
6573TQ120
6571TQ150
6571TQ185
6571TQ240
6571TQ300
6571TQ400
6571TQ500
6571TQ630

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
10
10
10
10
16
16
16
16
25
25
25
25
35
35
35
35
50
50
50
50
70
70
70
95
95
95
120
120
150
185
240
300
400
500
630

7/1.35
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/1.70
7/1.70
19/1.35
19/1.35
19/1.35
19/1.35
19/1.53
19/1.53
19/1.53
19/1.53
19/1.78
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
37/1.78
37/1.78
37/1.78
37/2.03
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
91/2.36
91/2.65
127/2.52

NO. OF
CORES

WEIGHT
KG/KM

1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
3
4
1
3
4
1
3
1
1
1
1
1
1
1

165
470
595
745
230
655
830
1045
380
1090
1340
1680
490
1310
1630
2130
640
1720
2210
2840
870
3080
3950
1150
4060
5170
1440
5130
1770
2200
2780
3450
4400
5600
6910

OVERALL
DIAMETER
(MM)
9.0
16.0
17.2
18.9
10.1
18.3
19.5
21.7
12.4
22.9
24.4
27.1
13.6
25.3
27.1
30.1
15.5
29.0
30.9
34.6
17.5
35.3
39.2
19.6
40.3
45.1
21.4
44.4
23.8
26.3
29.5
32.6
36.7
40.5
44.4

Single core cables are available in


Black or Green/Yellow outer sheath.

Core identification:
White with Black numbers.

Temperature limits:
-30 to +85C.

Should not be installed at


temperatures below -15C.

GLAND
SIZE
(MM)
20S
25
25
25
20S
25
32
32
20
32
32
40
25
32
40
40
25
40
40
50S
25
50S
50
32
50
63S
32
63S
32
40
40
50S
50S
50
63S

Bending radius:
up to 25mm - 4 x overall diameter.
above 25mm - 6 x overall diameter.

EPR INSULATED
NON-ARMOURED
SHIPWIRING CABLE
(10MM2 TO 630MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

MARINE AND OFFSHORE CABLES

MARINE AND OFFSHORE CABLES

MARINE AND OFFSHORE CABLES

86

MARINE AND OFFSHORE CABLES


Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR)
insulated, low smoke, zero halogen (LSOH) bedding, galvanised steel wire
braid armour, low smoke, zero halogen (LSOH) SW4 outer sheath. Black.
600/1000 volts grade to BS6883 IEE 92-3.
CCC
CODE
6582TQ1/5
6583TQ1/5
6584TQ1/5
6585TQ1/5
6586TQ1/5
6587TQ1/5
6580/12TQ1/5
6580/19TQ1/5
6580/27TQ1/5
6580/37TQ1/5
6582TQ2/5
6583TQ2/5
6584TQ2/5
6585TQ2/5
6586TQ2/5
6587TQ2/5
6580/12TQ2/5
6580/19TQ2/5
6580/27TQ2/5
6580/37TQ2/5
6582TQ4
6583TQ4
6584TQ4
6585TQ4
6587TQ4

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
4.0

7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
5
6
7
12
19
27
37
2
3
4
5
6
7
12
19
27
37
2
3
4
5
7

300
325
395
407
425
525
790
1090
1515
1870
350
400
470
485
550
635
990
1390
1990
2500
480
530
585
700
897

OVERALL
DIAMETER
(MM)
13.3
13.8
15.0
15.2
16.5
17.2
21.7
24.7
29.3
33.2
14.2
15.0
16.1
16.9
18.2
18.5
23.9
27.6
33.2
36.7
16.6
17.3
18.4
20.2
22.7

Temperature limits:
-30 to +85C.

Core identification:
White with Black numbers.

Bending radius:
6 x overall diameter.

Should not be installed at


temperatures below -15C.

GLAND
SIZE
(MM)
20S
20S
20S
20S
20
20
25
25
32
32
20S
20S
20
20
20
20
25
32
32
40
20
20
20
20
25

EPR INSULATED
BRAIDED ARMOUR
SHIPWIRING CABLE
(1.5MM2 TO 4MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

87

Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR)


insulated, low smoke, zero halogen (LSOH) bedding, galvanised steel wire
braid armour, low smoke, zero halogen (LSOH) outer sheath. Black. 600/1000
volts grade to BS6883 & IEE92-3 .
CCC
CODE
6582TQ6
6583TQ6
6584TQ6
6582TQ10
6583TQ10
6584TQ10
6582TQ16
6583TQ16
6584TQ16
6582TQ25
6583TQ25
6584TQ25
6582TQ35
6583TQ35
6584TQ35
6582TQ50
6583TQ50
6584TQ50
6582TQ70
6583TQ70
6584TQ70
6582TQ95
6583TQ95
6584TQ95
6582TQ120
6583TQ120
6584TQ120
6582TQ150
6583TQ150
6584TQ150
6582TQ185
6583TQ185
6584TQ240
6582TQ240
6583TQ300
6584TQ300

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
6
6
6
10
10
10
16
16
16
25
25
25
35
35
35
50
50
50
70
70
70
95
95
95
120
120
120
150
150
150
185
185
240
240
300
300

7/1.04
7/1.04
7/1.04
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/1.70
19/1.35
19/1.35
19/1.35
19/1.53
19/1.53
19/1.53
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
37/1.78
37/1.78
37/1.78
37/2.03
37/2.03
37/2.03
37/2.25
37/2.25
37/2.25
37/2.52
37/2.52
61/2.25
61/2.25
61/2.52
61/2.52

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
3
4
3
4
3
4

570
635
760
750
930
1080
1020
1190
1450
1500
1800
2500
1810
2400
2880
2510
3000
3670
2940
3980
4840
3813
5290
6310
4692
6480
7770
5634
7700
9400
9550
11520
12300
14840
14850
17938

OVERALL
DIAMETER
(MM)
17.9
18.7
20.1
21.0
22.4
24.0
23.7
24.9
26.9
29.0
30.7
33.6
31.0
34.0
36.2
36.0
38.1
41.0
36.0
42.8
46.1
40.9
48.5
52.6
44.9
52.9
57.4
48.9
57.9
63.1
63.8
69.6
71.5
78.3
78.8
84.9

Temperature limits:
-30 TO +85C.

Core identification:
White with Black numbers.

Bending radius:
6 x overall diameter

Should not be installed at


temperatures below -15C.

GLAND
SIZE
(MM)
20
20
20
25
25
25
25
25
25
32
32
40
32
40
40
40
40
50S
40
50S
50
50S
50
63S
50S
63S
63S
50
63S
63
63
75S
75
90
90
90

EPR INSULATED
BRAIDED ARMOURED
SHIPWIRING CABLE
(6MM2 TO 300MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

MARINE AND OFFSHORE CABLES

MARINE AND OFFSHORE CABLES

MARINE AND OFFSHORE CABLES

88

MARINE AND OFFSHORE CABLES


Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR)
insulated, low smoke, zero halogen (LSOH) bedding tinned phosphor bronze
braid armour, low smoke, zero halogen (LSOH) outer sheath. Black. 600/1000
volts grade to BS6883 & IEE92-3 .
CCC
CODE
6591TQ6
6591TQ10
6591TQ16
6591TQ25
6591TQ35
6591TQ50
6591TQ70
6591TQ95
6591TQ120
6591TQ150
6591TQ185
6591TQ240
6591TQ300
6591TQ400
6591TQ500
6591TQ630

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

7/1.04
7/1.35
7/1.70
19/1.35
19/1.53
19/1.78
19/2.14
37/1.78
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
91/2.36
91/2.65
127/2.52

NO. OF
CORES

WEIGHT
KG/KM

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

245
320
395
565
740
940
1270
1600
1930
2330
3000
3710
4480
5340
6540
8000

OVERALL
DIAMETER
(MM)
11.7
13.4
14.5
17.3
18.4
20.3
22.7
25.0
27.2
29.5
33.1
36.6
40.0
43.9
48.1
52.3

Temperature limits:
-30 to +85C.

Core identification:
White.

Bending radius:
6 x overall diameter.

Should not be installed at


temperatures below -15C.

GLAND
SIZE
(MM)
20/16
20S
20S
20
20
20
25
25
32
32
32
40
50S
50S
50
50

EPR INSULATED SINGLE


CORE BRAIDED
SHIPWIRING CABLE
(6MM2 TO 630MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

89

FIREPROOF CABLES

FIREPROOF CABLES

FIREPROOF CABLES

90

FIREPROOF CABLES
Solid plain annealed copper conductors, magnesium oxide insulated, solid copper
sheath to BS6207, IEC 331 and BS 6387 CWZ. Available in the following options:
(a) Light Duty = 500 volts grade
Heavy Duty = 1000 volts grade

(b) Outer sheath finishes, bare copper,


PVC or LSF
(c) Outer sheath colours. Orange, Red
or White.

SIZE
REF.
2L1.0
2L1.5
2L2.5
2L4.0
3L1.0
3L1.5
3L2.5
4L1.0
4L1.5
4L2.5
7L1.5
7L2.5
1H6.0
1H10
1H16
1H25
1H35
1H50
1H70
1H95
1H120
1H150
1H240

BARE SHEATHED OVERALL OVERALL GLAND


KG/KM
KG/KM DIAMETER DIAMETER FOR USE
BARE SHEATHED WITH RPS
(MM)
(MM)
SEALS
105
126
5.1
6.4
20
131
154
5.7
7.0
20
180
206
6.6
7.9
20
262
322
7.7
9.2
20
136
159
5.8
7.1
20
168
194
6.4
7.7
20
222
272
7.3
8.8
20
162
187
6.3
7.6
20
203
231
7.0
8.3
20
286
336
8.1
9.6
20
310
351
8.4
9.9
25
433
475
9.7
11.2
25
173
213
6.4
7.7
20
233
273
7.3
8.8
20
321
361
8.3
9.8
20
456
506
9.6
11.1
20
600
650
10.7
12.2
20
782
842
12.1
13.6
25
1087
1147
13.7
15.2
25
1450
1520
15.4
17.4
25
1790
1870
16.8
18.8
32
2130
2230
18.4
20.4
32
3146
3312
23.3
26.1
40

Temperature limits:
PVC sheath -20 to +70C.
LSF sheath -20 to +80C.
SIZE
REF.
2H1.5
2H2.5
2H4.0
2H6.0
2H10
2H16
2H25
3H1.5
3H2.5
3H4.0
3H6.0
3H10
3H16
3H25
4H1.5
4H2.5
4H4.0
4H6.0
4H10
4H16
4H25
7H1.5
7H2.5
12H2.5
19H1.5

MINERAL
INSULATED CABLE

SINGLE HOLE CLIP NOMINAL


REFERENCE
STD DRUM
BARE SHEATHED LTHS (MTS)
20
20
26
30
22
24
28
24
28
32
32
37
24
28
32
37
40
47
54
59
63
71
88

26
28
32
37
28
30
34
30
34
37
40
43
34
34
37
43
47
54
59
67
75
79
101

500
500
500
500
500
500
500
500
500
500
380
285
650
510
400
275
222
170
190
155
135
110
67

Bending radius: 6 x overall diameter.


Should not be installed at
temperatures below 0C.

BARE SHEATHED OVERALL OVERALL GLAND


KG/KM
KG/KM DIAMETER DIAMETER FOR USE
BARE SHEATHED WITH RPS
(MM)
(MM)
SEALS
224
259
7.9
9.4
20
275
314
8.7
10.2
20
355
398
9.8
11.3
20
433
483
10.9
12.4
20
637
697
12.7
14.2
25
888
968
14.7
16.2
25
1175
1275
17.1
19.1
32
253
290
8.3
9.8
20
324
365
9.3
10.8
20
416
461
10.4
11.9
20
530
590
11.5
13.0
25
783
853
13.6
15.1
25
1000
1080
15.6
17.1
25
1442
1548
18.2
20.2
40
303
344
9.1
10.6
20
385
430
10.1
11.6
20
517
577
11.4
12.9
25
658
718
12.7
14.2
25
980
1050
14.8
16.3
25
1300
1390
17.3
19.3
32
1800
1943
20.1
22.3
40
431
478
10.8
12.3
25
561
614
12.1
13.6
25
875
970
15.6
17.9
32
989
1086
16.6
18.9
40

SINGLE HOLE CLIP NOMINAL


REFERENCE
STD DRUM
BARE SHEATHED LTHS (MTS)
30
34
37
43
47
54
67
32
37
40
43
54
59
71
34
40
43
47
54
67
79
43
47
59
63

37
40
43
47
54
63
75
37
43
47
51
59
71
79
43
47
54
54
63
75
88
47
54
71
71

Should not be installed at


temperatures below 0C.
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

500
500
500
500
500
112
80
500
500
500
184
130
100
70
500
500
195
144
110
89
60
245
195
148
112

91

Plain annealed copper conductor, silicon rubber insulated aluminium/polyester


tape screen, tinned annealed copper earth wire, low smoke halogen free (LSOH)
outer sheath. Red, White, Orange or Black. Fire resistant to IEC 331 and BS6387.
Flame retardant to BS5839-1:2003 and IEC 332 PT3 CAT CWZ.
CCC
CODE
FP2X1
FP3X1
FP4X1
FP7X1
FP12X1
FP2X1/ 5
FP3X1/ 5
FP4X1/5
FP7X1/5
FP12X1/5
FP19X1/5
FP2X2/5
FP3X2/5
FP4X2/5
FP7X2/5
FP12X2/5
FP19X2/5
FP2X4
FP3X4
FP4X4

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND 1 HOLE GLAND


SIZE (MM2)
(MM)
CORES KG/KM DIAMETER SIZE CLIP REF REF
(MM)
(MM)
1.0
1/1.13
2+E
90
7.5
20
32
251
1.0
1/1.13
3+E
110
8.0
20
34
251
1.0
1/1.13
4+E
135
8.8
20
40
251
1.0
1/1.13
7+E
170
10.5
20
47
252
1.0
1/1.13
12+E
270
13.7
25
59
254
1.5
1/1.38
2+E
110
8.0
20
34
251
1.5
1/1.38
3+E
130
8.4
20
40
251
1.5
1/1.38
4+E
160
9.5
20
43
251
1.5
1/1.38
7+E
230
11.3
20
51
252
1.5
1/1.38
12+E
365
15.2
25
67
254
1.5
1/1.38
19+E
540
17.8
25
79
254
2.5
7/0.67
2+E
160
9.0
20
40
252
2.5
7/0.67
3+E
200
10.5
20
47
252
2.5
7/0.67
4+E
250
11.7
20
47
252
2.5
7/0.67
7+E
285
13.7
20
54
252
2.5
7/0.67
12+E
470
17.9
25
75
254
2.5
7/0.67
19+E
720
21.4
32
88
255
4.0
7/0.85
2+E
260
11.3
20
43
252
4.0
7/0.85
3+E
315
12.1
25
54
254
4.0
7/0.85
4+E
380
13.3
25
54
254

E= Earth conductor.
Temperature limits:
-10 to +80C.
Bending radius:
6 x overall diameter.

Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
7 core and above - White with Black
numbers.
Should not be installed at
temperatures below 0C.

FIRE RESISTANT
SECURITY CABLE
(1.0MM2 TO 4MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

FIREPROOF CABLES

FIREPROOF CABLES

FIREPROOF CABLES

92

FIREPROOF CABLES
Plain annealed stranded copper conductor, mica fire resistant tape, XLPE
insulated, low smoke halogen free (LSOH) bedding, galvanised steel wire
armour, low smoke halogen free (LSOH) outer sheath. Black. 600/1000 volts.
Fire resistant to IEC 331 & BS7846 / BS6387 & CWZ.
Flame propagation to BS4066 PT1 and IEC 332 PT1 (PT3 for bunched cables).
CCC
CODE
6942F1/5
6943F1/5
6944F1/5
6947F1/5
6940/12F1/5
6940/19F1/5
6940/27F1/5
6940/37F1/5
6942F2/5
6943F2/5
6944F2/5
6947F2/5
6940/12F2/5
6940/19F2/5
6940/27F2/5
6940/37F2/5
6942F4
6943F4
6944F4
6947F4
6942F6
6943F6
6944F6
6942F10
6943F10
6944F10
6942F16
6943F16
6944F16

CONDUCTOR STRANDING
(MM)
SIZE (MM2)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
6
6
6
10
10
10
16
16
16

Temperature limits:
-25 to +90C.
Bending radius:
8 x overall diameter.

7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/0.85
7/1.04
7/1.04
7/1.04
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/1.70

NO. OF
CORES
2
3
4
7
12
19
27
37
2
3
4
7
12
19
27
37
2
3
4
7
2
3
4
2
3
4
2
3
4

WEIGHT OUTSIDE
KG/KM DIAMETER
(MM)
340
13.6
380
14.2
420
15.1
500
17.3
820
22.1
1080
25.8
1550
30.4
1850
33.4
390
15.1
430
15.7
500
16.8
730
19.8
1020
24.9
1530
29.5
1950
34.4
2440
37.8
460
16.1
530
16.9
700
18.1
840
21.6
640
17.3
730
18.1
850
20.3
820
20.0
940
21.0
1090
22.6
1025
22.1
1370
23.5
1560
26.0

GLAND
SIZE
(MM)
20S
20S
20S
20
25
25
32
32
20S
20S
20
20
25
32
40
40
20
20
20
25
20
20
20
20
25
25
25
25
25

SINGLE
CLEAT

Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
7 core and above - White with
Black numbers.
Should not be installed at
temperatures below 0C.

FIRE RESISTANT POWER


AND CONTROL CABLE
(1.5MM2 TO 16MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

0.6
0.6
0.6
0.7
0.9
1.1
1.2
1.4
0.6
0.7
0.7
0.8
1.0
1.2
1.4
1.6
0.7
0.7
0.8
0.9
0.7
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.1

93

Plain annealed stranded copper conductor, mica fire resistant tape, XLPE
insulated, low smoke, zero halogen (LSOH) bedding, galvanised steel wire
armour, low smoke, zero halogen (LSOH) outer sheath. Black. 600/1000 volts
grade. Fire resistant to BS6387/7846 & CWZ.
Flame propagation to BS4066 PT1 and IEC 332 PT1 (PT3 for bunched cables).
CCC
CODE
FP 2X25
FP 3X25
FP 4X25
FP 2X35
FP 3X35
FP 4X35
FP 2X50
FP 3X50
FP 4X50
FP 2X70
FP 3X70
FP 4X70
FP 2X95
FP 3X95
FP 4X95
FP 2X120
FP 3X120
FP 4X120
FP 2X150
FP 3X150
FP 4X150
FP 2X185
FP 3X185
FP 4X185
FP 2X240
FP 3X240
FP 4X240
FP 2X300
FP 3X300
FP 4X300
FP 3X400
FP 4X400

CONDUCTOR STRANDING
(MM)
SIZE (MM2)
25
25
25
35
35
35
50
50
50
70
70
70
95
95
95
120
120
120
150
150
150
185
185
185
240
240
240
300
300
300
400
400

Temperature limits:
-25 to +90C.
Bending radius:
8 x overall diameter.

7/2.14
7/2.14
7/2.14
7/2.52
7/2.52
7/2.52
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
19/2.52
19/2.52
19/2.52
37/2.03
37/2.03
37/2.03
37/2.25
37/2.25
37/2.25
37/2.52
37/2.52
37/2.52
61/2.25
61/2.25
61/2.25
61/2.52
61/2.52
61/2.52
61/2.85
61/2.85

NO. OF
CORES
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
3
4

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
1200
22.0
1800
27.4
2100
29.1
1600
24.8
2100
29.2
2500
32.2
2000
28.0
2600
33.0
3200
35.0
2400
30.7
3400
37.0
4500
40.2
3300
35.3
4500
40.6
5600
44.0
3800
36.6
5500
43.8
7200
48.4
4400
39.3
6900
48.0
8500
52.5
5700
44.2
8200
52.0
10300
57.1
7200
48.0
10200
57.1
12800
62.7
8300
51.8
12200
63.0
15600
69.6
15000
69.5
20400
78.0

GLAND
SIZE
(MM)
25
25
32
25
32
32
32
32
40
40
40
50S
40
50S
50S
40
50S
50
40
50
50
50S
50
63S
50
63S
63
63S
63
75S
75S
75

SINGLE
CLEAT

Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
Should not be installed at
temperatures below 0C.

FIRE RESISTANT
POWER CABLE
(25MM2 TO 400MM2)
Please note that cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

0.9
1.1
1.2
1.0
1.2
1.4
1.2
1.4
1.4
1.4
1.6
1.6
1.4
2.0
1.8
1.6
1.8
2.0
1.6
2.0
R9
1.8
R9
R10
2.0
R10
R10
R9
R10
R11
R11
R12

FIREPROOF CABLES

FIREPROOF CABLES

94

95

INSTALLATION ACCESSORIES

INSTALLATION
ACCESSORIES

97

LML

LML Products Limited


Since its inception in 1968, LML has designed, manufactured and supplied a
comprehensive range of copper tube terminals including bespoke specials.
With in-house tooling and electroplating facilities, LML will always provide a
solution for its quality focused customers in compliance with BS EN ISO
9001:2000
Copper Tube Terminals
LML terminals are manufactured from seamless copper tube to BS EN 12449
and feature bell mouth entry up to 400mm2 and chamfered entry from
500mm2 to 1000mm2. All terminals and splices (other than parallel splices)
are provided with an inspection hole to ensure the conductor is fully inserted
before crimping. Internal barrel diameters suit standard cables as defined in
BS EN 6360.
Standard finish is bright electro tin plating to BS EN 1872. Other finishes can
be provided, e.g. nickel or silver. Terminals are independently tested to comply
with BS EN 61238-1, and are also approved for military use and by London
Underground.
Crimp Tooling
LML Products also supply a large range of manual hydraulic tools for crimping
terminals from 1.5mm2 to 1000mm2. LML also supplies a range of hydraulic
crimping tools with rechargeable battery.
Med/High Voltage Crimp Terminals
LML Products manufactures a range of copper tube terminals to suit 11kv and
33kv. We also manufacture water blocked splices and terminals.

101

RAXTON LIMITED

Raxton products are designed to solve the fundamental difficulties which


exist due to the variety of thread forms currently in use within the electrical
industry. These thread forms are predominantly Isometric, Imperial, N.P.T., BSP
and PG.
Problems caused by dissimilar threads can occur in many environments
including industrial, EExd, EExe and mining. Raxton conversions are fully
approved to meet these requirements, being certified by leading test
authorities including BASEEFA, SIRA, ISSEP, KEMA, DET NORSKE VERITAS and
Standards Association of Australia. They are marked accordingly.
Standard material is brass and readily available alternatives include mild
steel, stainless steel and aluminium. Our EExe range is also available in glass
filled nylon.
ADAPTORS
REDUCERS
HEXAGON HEAD PLUGS
RIGHT ANGLE ADAPTORS
MALE TO MALE ADAPTORS
UNIONS
STOPPING PLUGS
EARTH LEAD ADAPTORS
THREADED EARTH PLATES

NYLON GLANDS
SCREWED NIPPLING
COUPLERS
BUSHES
SHROUDS
LOCKNUTS/LOCKRINGS
EARTH TAGS
WASHERS

104

W. J. FURSE & COMPANY LIMITED

E-Klips is a division of W J Furse & Co Ltd, a multi-disciplined engineering and


marketing company employing nearly 200 people worldwide.
We are the largest UK manufacturer of a comprehensive range of industrial
fasteners, which are made available to the electrical/mechanical industry.
They provide a quick, efficient method of fixing without drilling or bracket making.
Our commitment to quality has set industry standards while our new designs
bring you all the benefits of E-Klips continuous product development philosophy.
Wholly manufactured in the UK, E-Klips fasteners can be found throughout
Europe and in many other countries in the world where our unequalled
combination of speed and quality is properly appreciated.
This combination can give you savings of up to 60% over a complete
installation a very significant competitive advantage!
E-Klips are available for every type of installation through our established
distributor network who are fully supported by our stocks and service.
So, if you would like to use the faster fastener, simply specify E-Klips and put
your opposition in the shade.

105

W. J. FURSE & COMPANY LIMITED

As a recognised world leader in the Earthing and Lightning Protection Industry,


W J Furse has a proven track record spanning over one hundred years.
The range complies with the requirements of relevant British and World
standards, and our design and manufacturing quality control systems are
independently assessed and approved to ISO9001. W J Furse can also offer a
level of competitiveness, service and technical support that is the envy of
competitors both in the UK and overseas.
Our extensive range includes the following:
Earth Rods
Copperbond, solid copper and stainless steel.
Earth Pits
Lightweight, high performance plastic and regular duty concrete pits.
Fittings
Clamps, bonds, clips and accessories in copper and aluminium alloys and
plastics suitable for flat tape and solid circular conductor systems.
Conductors
An extensive range of copper and aluminium conductors available bare and
PVC covered.
Specialist Products
Including weldable and adhesive conductor clips and earth rod seals.
Furseweld Process
An exothermic welding process with a simple self contained method of
forming high quality electrical connections which do not require external
power or heat source, making the process completely portable.

106

FRAMING AND SUPPORT SYSTEMS

CF1
CF28

CF2

CF14
CF9

CF21

CF29

CF3
CF22
CF15

CF34
CF4

CF10/1

CF16

CF23

CF5

CF35

CF11

CF17

CF24
CF36

CF6

CF18
CF37
CF25
CF7

CF12

CF38/1
CF38/2

CF19

CF26

CF8
CF27

CF13

CF20

CF39

107

Long Spring Channel Nuts

CF40

M6
M8
M10
M12

ZL6
ZL8
ZL10
ZL12

CF47
Short Spring Channel Nuts
M6
M8
M10
M12

PL1 PVC
GL1 Galv
CF41*

CCC1 41x21x2.5
Available in Both Plain and Slotted

ZS6
ZS8
ZS10
ZS12

Plain Channel Nuts


M6
M8
M10
M12

ZN6
ZN8
ZN10
ZN12

CCC2 41x21x2.5 Double

M10 x 40
Cone Pointed
Set Screws

CF42*
CA1
Available in 150, 300,
450, 600, 750mm

M6 x 12, 16, 20, 25,


30, 35 40 and 50mm
Roofing Nuts
CCC3 41x41x2.5
and Bolts
Available in Both Plain and Slotted
M6 x 8, M10 and
M12 x 20, 25, 30,
35, 40 and 50mm
Hex Head
Set Screws

CF44

CA2
Available in 150, 300,
450, 600, 750mm

M6, M8, M10 and


M12
Hex Nuts, Flat
and Spring
Washers

CF45*

CA3
Available in 150, 300,
450, 600, 750mm

CF46
FA1

Pvc 2

Pvc 1

CCC4 41x41x2.5 Double


Available Finishes
Pre Galvanised to BS 2989
HDG TO BS 729
Stainless Steel 316

M6, M8, M10


M12 x 3MTR Lengths
of Threaded Rod

108

109

CURRENT RATINGS

CURRENT RATINGS

CURRENT RATINGS

110

PVC AND LSF CONDUIT WIRING CABLES


PVC INSULATED ONLY, SINGLE CORE GENERAL PURPOSE WIRING CABLES TO BS6004
XL-LSF INSULATED ONLY, SINGLE CORE WIRING CABLES TO BS7211
Current Carrying Capacity (Amperes)
CONDUCTOR REFERENCE METHOD 4 REFERENCE METHOD 3 REFERENCE METHOD 1 REFERENCE METHOD 11 REFERENCE METHOD 12 (FREE AIR)
CROSS (ENCLOSED IN CONDUIT (ENCLOSED IN CONDUIT
(CLIPPED DIRECT)
(ON A PERFORATED
SECTIONAL
IN THERMALLY
ON A WALL OR IN
CABLE TRAY
HORIZONTAL VERTICAL
TREFOIL
AREA
INSULATING WALL ETC.)
TRUNKING ETC.)
HORIZONTAL OR
FLAT SPACED FLAT SPACED
VERTICAL)
2 CABLES
3 OR 4
2 CABLES
3 OR 4
2 CABLES
3 OR 4
2 CABLES
3 OR 4
2 CABLES 2 CABLES 3 CABLES
SINGLE
CABLES 3
SINGLE
CABLES
SINGLE
CABLES
SINGLE
CABLES
SINGLE
SINGLE
TREFOIL
PHASE
PHASE A. C
PHASE
3 PHASE
PHASE
3 PHASE
PHASE
3 PHASE
PHASE
PHASE
3 PHASE
A.C. or D.C
A.C. OR D.C.
A.C.
A.C. OR D.C. A.C FLAT & A.C or D.C. A.C. FLAT & A.C. OR D.C. A.C. OR D.C.
A.C.
FLAT & TOUCHING FLAT & TOUCHING OR 3 CABLES OR 3 CABLES
TOUCHING OR TREFOIL TOUCHING OR TREFOIL 3 PHASE
3 PHASE
1
2
3
4
5
6
7
8
9
10
11
12
MM2
AMP
AMP
AMP
AMP
AMP
AMP
AMP
AMP
AMP
AMP
AMP
1
14
13
17
15
19
17.5
1.5
18
17
22
19
25
23
2.5
24
23
30
26
34
31
4
33
30
40
35
46
41
6
43
39
51
45
59
54
10
58
53
71
63
81
74
16
76
70
95
85
109
99
25
100
91
126
111
143
130
158
140
183
163
138
35
124
111
156
138
176
161
195
176
226
203
171
50
149
135
189
168
228
209
293
215
274
246
209
70
189
170
240
214
293
268
308
279
351
318
270
95
228
205
290
259
355
326
375
341
426
389
330
120
263
235
336
299
413
379
436
398
495
453
385
150
300
270
375
328
476
436
505
461
570
524
445
185
341
306
426
370
545
500
579
530
651
600
511
240
400
358
500
433
644
590
686
630
769
711
606
300
459
410
513
493
743
681
794
730
886
824
701
400
683
584
868
793
915
849
1065
984
820
500
783
666
990
904
1044
973
1228
1150
936
630
900
764
1130
1033
1191
1115
1423
1338
1069
800
1288
1179
1358
1275
1581
1485
1214
1000
1443
1323
1520
1436
1775
1671
1349

Note: Where the conductor is to be protected by a semi-enclosed fuse to BS3036, see item 6.2 of the preface to
appendix 4 of BS7671, the 16th Edition of the IEE Wiring Regulations.
The current-carrying capacities in columns 2 to 5 are also applicable to flexible cables to BS 7211 Table 3(b) where the
cables are used in fixed installations.
For cable in rigid PVC conduit the values stated in Table 4D1 of BS 7671, the 16th Edition of the IEE Wiring Regulations
are applicable (See Regulations 521-05).
Where a conductor operates at a temperature exceeding 70C it shall be ascertained that the equipment connected
to the conductor is suitable for the conductor operating temperature (See Regulation 512-02 of BS 7671, the 16th
Edition of the IEE Wiring Regulations).
Table derived from IEE copyright information.
BS 7671 - 16th Edition, IEE Wiring Regulations.
Ambient temperature: 30C.
Conductor operating temperature: 90C.

111

(NON-MAGNETIC ARMOUR), COPPER CONDUCTORS BS5467 BS6724.


Current Carrying Capacity (Amperes)
CONDUCTOR REFERENCE METHOD 1
CROSS
(CLIPPED DIRECT)
SECTIONAL
AREA
2 CABLES
3 OR 4
SINGLE
CABLES 3
PHASE
PHASE A.C.
A.C. OR D.C FLAT &
FLAT & TOUCHING
TOUCHING
2
3
MM2
AMP
AMP
50
237
220
70
303
277
95
367
333
120
425
383
150
488
437
185
557
496
240
656
579
300
755
662
400
853
717
500
962
791
630
1082
861
800
1170
904
1000
1261
961

REFERENCE METHOD 2
(ON A PERFORATED
CABLE TRAY)

REFERENCE METHOD 12 (FREE AIR)

2 CABLES
2 CABLES D.C.
3 OR 4 CABLES, 3 PHASE A.C.
SINGLE PHASE A.C.
2 CABLES
3 OR 4 HORIZONTAL VERTICAL HORIZONTAL VERTICAL HORIZONTAL VERTICAL 3 CABLES
SINGLE
CABLES 3
FLAT
FLAT
SPACED
SPACED
FLAT
FLAT
TREFOIL
PHASE
PHASE
SPACED
SPACED
SPACED
SPACED
A.C. FLAT & A.C. FLAT &
TOUCHING TOUCHING
4
AMP
253
322
389
449
516
587
689
792
899
1016
1146
1246
1345

5
AMP
232
293
352
405
462
524
612
700
767
851
935
987
1055

6
AMP
282
357
436
504
566
643
749
842
929
1032
1139
1204
1289

7
AMP
266
337
412
477
539
614
714
805
889
989
1092
1155
1238

8
AMP
284
356
446
519
600
688
815
943
1137
1314
1528
1809
2100

9
AMP
270
349
426
497
575
660
782
906
1094
1266
1474
1744
2026

10
AMP
288
358
425
485
549
618
715
810
848
923
992
1042
1110

11
AMP
266
331
393
449
510
574
666
755
797
871
940
978
1041

12
AMP
222
285
346
402
463
529
625
720
815
918
1027
1119
1214

Voltage Drop per Ampere per metre (mV)


CONDUCTOR
CROSS
SECTIONAL
AREA

2
CABLES
D.C.

1
MM2

2
MV

50
70
95
120
150
185
240
300
400
500
630
800
1000

0.98
0.67
0.49
0.39
0.31
0.25
0.195
0.155
0.115
0.093
0.073
0.056
0.045

2 CABLES - SINGLE PHASE A.C.

3 OR 4 CABLES - 3 PHASE A.C.

REFERENCE METHODS
1 & 11 (TOUCHING)

REFERENCE METHOD
12 (SPACED)

3
MV
x
0.21
0.200
0.195
0.190
0.185
0.185
0.180
0.175
0.170
0.170
0.165
0.160
0.155

4
MV
x
0.29
0.29
0.28
0.27
0.27
0.26
0.26
0.25
0.24
0.24
0.23
0.23
0.21

r
0.99
0.68
0.51
0.41
0.33
0.27
0.21
0.170
0.145
0.125
0.105
0.090
0.092

z
1.00
0.71
0.55
0.45
0.38
0.33
0.28
0.25
0.22
0.21
0.195
0.190
0.180

r
0.98
0.69
0.53
0.43
0.36
0.30
0.24
0.195
0.180
0.165
0.150
0.145
0.140

z
1.00
0.75
0.60
0.51
0.45
0.40
0.35
0.32
0.30
0.29
0.27
0.27
0.25

REFERENCE METHODS
1, 11 & 12
(IN TREFOIL TOUCHING)
5
MV
r
x
z
0.86 0.180 0.87
0.59 0.170 0.62
0.44 0.170 0.47
0.35 0.165 0.39
0.29 0.160 0.33
0.23 0.160 0.28
0.180 0.155 0.24
0.145 0.150 0.21
0.125 0.150 0.195
0.105 0.145 0.180
0.092 0.145 0.170
0.086 0.140 0.165
0.080 0.135 0.155

REFERENCE METHODS
1 & 11
FLAT & TOUCHING)
6
MV
r
x
z
0.84
0.25
0.88
0.60
0.25
0.65
0.46
0.24
0.52
0.38
0.24
0.44
0.31
0.23
0.39
0.26
0.23
0.34
0.21
0.22
0.30
0.170 0.22
0.28
0.160 0.21
0.27
0.145 0.20
0.25
0.135 0.195 0.24
0.130 0.180 0.23
0.125 0.170 0.21

REFERENCE METHOD
12
(FLAT SPACED)
7
MV
r
x
z
0.84
0.33
0.90
0.62
0.32
0.70
0.49
0.31
0.58
0.41
0.30
0.51
0.34
0.29
0.45
0.29
0.29
0.41
0.24
0.28
0.37
0.20
0.27
0.34
0.20
0.27
0.33
0.190 0.24
0.31
0.175 0.23
0.29
0.175 0.195 0.26
0.165 0.180 0.24

Note: Spacings larger than those specified in Method 12 (see Table 4A, BS7671 - 16th Edition, IEE Wiring Regulations)
will result in larger voltage drop.
Table derived from IEE copyright information.
Conductor operating temperature: 90C.

CURRENT RATINGS

SINGLE CORE CABLES HAVING THERMOSETTING INSULATION

CURRENT RATINGS

112

MULTICORE ARMOURED CABLES HAVING THERMOSETTING INSULATION


COPPER CONDUCTORS BS5467 BS6724.
Current Carrying Capacity (Amperes)
CONDUCTOR
CROSS SECTIONAL

REFERENCE METHOD 1
(CLIPPED DIRECT)
AREA
2 CORE CABLE
3 OR 4
SINGLE PHASE
CORE CABLE,
A.C. or D.C.
3 PHASE A.C.
2
3
AMP
AMP
27
23
36
31
49
42
62
53
85
73
110
94
146
124
180
154
219
187
279
238
338
289
392
335
451
386
515
441
607
520
698
599
787
673

1
MM2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400

Note: 1. Where the conductor is to be protected by a


semi-enclosed fuse to BS3036, see item 6.2 of the
preface to appendix 4 of BS7671, the IEE Wiring
Regulations, 16th Edition.
2. Where a conductor operates at a temperature
exceeding 70C it shall be ascertained that the

REFERENCE METHOD 11
(ON A PERFORATED HORIZONTAL OR VERTICAL TRAY)
OR REFERENCE METHOD 13 (FREE AIR)
2 CORE CABLE
3 OR 4
SINGLE PHASE
CORE CABLE,
A.C. OR D.C.
3 PHASE A.C.
4
5
AMP
AMP
29
25
39
33
52
44
66
56
90
78
115
99
152
131
188
162
228
197
291
251
354
304
410
353
472
406
539
463
636
546
732
628
847
728

equipment connected to the conductor is suitable


for the conductor operating temperature (see
Regulation 512-02 of BS 7671, the IEE Wiring
Regulations, 16th Edition).
Ambient temperature: 30C.
Conductor operating temperature: 70C.

VoLtage Drop per Ampere per Metre (mV)


CONDUCTOR
CROSS SECTIONAL
AREA
1
MM2
1.5
2.5
4
6
10
16

2 CORE
CABLE D.C

2 CORE CABLE
SINGLE PHASE A.C.

3 OR 4 CABLE
3 PHASE A.C

2
MV
31
19
12
7.9
4.7
2.9

3
MV
31
19
12
7.9
4.7
2.9

4
MV
27
16
10
6.8
4.0
2.5

25
35
50
70
95
120
150
185
240
300
400

1.85
1.35
0.98
0.67
0.49
0.39
0.31
0.25
0.195
0.155
0.120

r
1.85
1.35
0.99
0.67
0.50
0.40
0.32
0.26
0.20
0.16
0.13

Tables derived from IEE copyright information.


Conductor operating temperature: 90C.

x
0.160
0.155
0.155
0.150
0.150
0.145
0.145
0.145
0.140
0.140
0.145

z
1.90
1.35
1.00
0.69
0.52
0.42
0.35
0.29
0.24
0.21
0.195

r
1.60
1.15
0.86
0.59
0.43
0.34
0.28
0.22
0.175
0.140
0.115

x
0.140
0.135
0.135
0.130
0.130
0.130
0.125
0.125
0.125
0.120
0.125

z
1.65
1.15
0.87
0.60
0.45
0.37
0.30
0.26
0.21
0.185
0.170

113

COPPER CONDUCTORS BS5467 BS6724.


Current RATINGS (ac)
NOMINAL
AREA OF
CONDUCTOR
MM2
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

DIRECT IN GROUND
TREFOIL GROUP
FLAT SPACED=
UNARMD ARMD UNARMD ARMD
AMP
AMP
AMP
AMP
220
220
230
230
270
270
280
280
320
320
335
335
360
360
380
380
410
410
430
430
460
455
485
485
530
520
560
560
600
580
640
640
680
650
730
730
750
710
830
830
830
760
940
940
920
810
1070
1060
1000
860
1180
1170

SINGLE CORE
IN SINGLE-WAY DUCTS
TREFOIL GROUP
FLAT TOUCHING
UNARMD ARMD UNARMD ARMD
AMP
AMP
AMP
AMP
225
220
220
220
270
260
270
270
320
305
325
325
360
340
370
370
400
375
415
410
440
410
465
460
505
470
540
540
560
500
610
610
610
530
690
690
680
570
790
780
750
620
890
890
830
660
1010
990
910
690
1100
1090

=Adjacent cable surfaces separated by one cable diameter.

IN FREE AIR
TREFOIL GROUP
FLAT SPACED=
UNARMD ARMD UNARMD ARMD
AMP
AMP
AMP
AMP
235
250
295
300
285
310
370
370
360
375
455
460
415
430
520
530
470
490
600
600
540
550
690
690
640
650
820
820
740
740
940
940
840
840
1100
1100
990
930
1280
1280
1110
1040
1500
1480
1270
1140
1720
1690
1400
1230
1950
1900

CURRENT RATINGS

SINGLE CORE CABLES HAVING THERMOSETTING INSULATION

CURRENT RATINGS

114

MULTICORE ARMOURED CABLES HAVING THERMOSETTING INSULATION,


ALUMINIUM CONDUCTORS BS5467 BS6724.
Current Carrying Capacity (Amperes)
CONDUCTOR
CROSS SECTIONAL
AREA

REFERENCE METHOD 1
(CLIPPED DIRECT)
2 CORE CABLE
SINGLE PHASE
A.C. or D.C.
2
AMP
82
108
132
159
201
242
-

1
MM2
16
25
35
50
70
95
120
150
185
240
300

REFERENCE METHOD 2 (ON A PERFORATED CABLE TRAY)OR


REFERENCE METHOD 13 (FREE AIR)

3 OR FOUR
CORE CABLE,
3 PHASE A.C.
3
AMP
71
92
113
137
174
214
249
284
328
386
441

Note: 1. Where the conductor is to be protected by a


semi-enclosed fuse to BS3036, see item 6.2 of the
preface to appendix 4 of BS7671, the IEE Wiring
Regulations, 16th Edition.
2. Where a conductor operates at a temperature
exceeding 70C it shall be ascertained that the
equipment connected to the conductor is suitable

2 CORE CABLE
SINGLE PHASE
A.C. OR D.C.
4
AMP
85
112
138
166
211
254
-

3 OR 4
CORE CABLE,
3 PHASE A.C.
5
AMP
74
98
120
145
185
224
264
305
350
418
488

for the conductor operating temperature (see


Regulation 512-02 of BS 7671, the IEE Wiring
Regulations, 16th Edition).
Ambient temperature: 30C.
Conductor operating temperature: 90C.

Voltage Drop per Ampere per Metre (mV)


ONDUCTOR
CROSS SECTIONAL
AREA
MM2
16

2 CORE
CABLE D.C.
2
MV
4.8

25
35
50
70
95
120
150
185
240
300

3.1
2.2
1.60
1.10
0.82
-

r
3.1
2.2
1.65
1.10
0.82

2 CORE CABLE
SINGLE PHASE A.C.
3
MV
4.8
x
0.165
0.160
0.160
0.155
0.150
-

Tables derived from IEE copyright information.


Conductor operating temperature: 90C.

z
3.1
2.2
1.65
1.15
0.84

r
2.7
1.90
1.40
0.96
0.71
0.56
0.45
0.37
0.28
0.23

3 OR 4 CABLE
3 PHASE A.C.
4
MV
4.2
x
0.140
0.140
0.135
0.135
0.130
0.130
0.130
0.130
0.125
0.125

z
2.7
1.95
1.45
0.97
0.72
0.58
0.47
0.39
0.31
0.26

115

RATING FACTORS, MAXIMUM AMBIENT AND OPERATING TEMPERATURES FOR CABLES AND CORDS. COPPER CONDUCTORS
NOMINAL
CROSS SECTIONAL
AREA OF CONDUCTOR
1
MM2
0.5
0.75
1.0
1.25
1.5
2.5
4.0

CURRENT CARRYING CAPACITY (AMPERES)


D.C. OR
3 PHASE
SINGLE PHASE A.C.
A.C.
2
AMP
3
6
10
13
16
25
32

VOLT DROP PER AMPERE PER METRE


D.C. OR
3 PHASE
SINGLE PHASE A.C.
A.C.

3
AMP
3
6
10
16
20
25

Note: The tabulated voltage drop values above are for


60C PVC insulated flexible cords. For 85C PVC
insulated flexible cords they are to be multiplied
by a factor of 1.09.

4
MV
93
62
46
37
32
19
12

5
MV
80
54
40
27
16
10

MAXIMUM MASS
SUPPORTABLE BY TWIN
FLEXIBLE CORD (SEE
REGULATION 522-8-06)
6
KG
2
3
5
5
5
5
5

Table derived from IEE copyright information.


BS 7671 - 16th Edition, IEE Wiring Regulations.
Conductor operating temperature: 60C.

Correction factor for ambient temperature


AMBIENT TEMPERATURE
CORRECTION FACTOR

35C
0.91

40C
0.82

45C
0.71

50C
0.58

55C
0.41

Maximum ambient and operating temperature for cables and cords


TYPE OF
INSULATION
OR SHEATH

GENERAL
PURPOSE PVC
HEAT RESISTING
PVC

MAXIMUM AMBIENT TEMPERATURE


OF SURROUNDINGS
NON FLEXIBLE CABLES
LEXIBLE CABLES
AND FLEXIBLE CORDS

C
65

F
179

C
65

F
149

80

179

75

167

MAXIMUM NORMAL OPERATING TEMPERATURE


OF CABLE INSULATION OR SHEATH
ALL FIXED OR FLEXIBLE CABLES
PARTS OF FLEXIBLE CORDS
AND FLEXIBLE CORDS EXCEPT CONTAINED WITHIN A LIGHTING
FITTING, APPLIANCE OR
AS PROVIDED IN
ACCESSORY, AND NOT SUBJECT
COLUMNS MARKED*
TO FLEXING OR OTHER
MECHANICAL STRESS
C
F
C
F
70
58
75
167
85

185

100

212

CURRENT RATINGS

CURRENT RATINGS FOR FLEXIBLE CORDS;

CURRENT RATINGS

116

XLPE INSULATED 600/1000 AND 1900/3300 VOLTS CABLES WITH COPPER


CONDUCTORS SUSTAINED CURRENT RATING (AMP)(50HZ) ERA PARAMETERS
NOMINAL
CONDUCTOR
AREA
MM2
50
70
95
120
150
185
240
300
400
500
630
800
1000

NOMINAL
CONDUCTOR
AREA
MM2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400

600/1000 VOLTS 3 SINGLE CORE CABLES


IN TREFOIL ARRANGEMENT
DIRECT
DUCT
AIR
AIR
ARMOURED
ARMOURED
UNARMOURED
ARMOURED
231
231
223
231
284
278
284
295
340
327
352
362
386
366
412
420
431
396
475
483
485
437
551
555
558
489
658
654
623
534
761
745
691
567
887
851
765
615
1027
963
841
664
1186
1084
888
692
1347
1178
942
735
1503
1278

600/1000 VOLTS TWIN CORE


ARMOURED CABLE
DIRECT
DUCT
AIR
38
49
65
81
109
141
183
219
259
317
381
433
485
547
632
708
799

31
41
53
67
89
115
148
178
211
260
313
357
401
455
527
592
669

31
41
55
70
95
126
164
202
244
306
378
437
499
576
680
775
892

1900/3300 VOLTS 3 SINGLE CORE CABLES


IN TREFOIL ARRANGEMENT
DIRECT
DUCT
AIR
ARMOURED
ARMOURED
ARMOURED
222
219
240
271
264
300
324
310
368
366
342
428
409
376
487
460
414
556
528
464
656
589
506
747
651
535
851
720
579
963
789
624
1084
831
650
1178
880
689
1278

600/1000 VOLTS 3 OR 4 CORE


ARMOURED CABLE
DIRECT
DUCT
AIR
32
42
55
69
92
119
152
182
217
266
319
363
406
458
529
592
667

Cables shall only be continuously operated at their


tabulated rating if the minimum current at which circuit
protection is designed to operate does not exceed 1.45
times (in the case of cables in air or in ducts) or 1.3 times
(in the case of cables laid direct in the ground) the values
given above.

26
34
45
56
75
96
124
149
177
218
263
300
338
382
442
496
570

1900/3300 VOLTS 3 CORE


ARMOURED CABLE
DIRECT
DUCT
AIR

26
35
47
59
82
107
140
172
209
263
324
376
430
495
584
666
766

114
147
175
207
254
304
345
387
436
502
563
633

96
124
147
174
214
257
293
328
371
428
480
549

112
149
177
213
268
328
380
432
496
583
667
765

Standard depth of laying:

0.5m for 600/1000 volts


cables.
0.8m for 1900/3300
volts cables.

Thermal resistivity of soil:

1.2K.m/W.

Standard ground temperature: 15C.


Ambient air temperature:

25C.

117

Minimum bending radius for fixed wiring


INSULATION

FINISH

OVERALL DIAMETER

PVC

NON-ARMOURED

NOT EXCEEDING 10mm


EXCEEDING 10mm BUT NOT EXCEEDING 25mm
EXCEEDING 25mm
ANY

ARMOURED

FACTOR APPLIED TO O.D. OF CABLE TO


DETERMINE MINIMUM INTERNAL RADIUS OF BEND
3
4*
6*
6*

*For circular conductors only. For shaped conductor cables, the minimum bending radius factor is 8.
Suggested minimum bending radius for flexible cables and cords
DESCRIPTION

OVERALL DIAMETER

FIXED BENDS AND SETS


FLEXIBLE CORDS AND CABLES

MM
UP TO 10
10 TO 25
ABOVE 25

2
3
4

UP TO 25
ABOVE 25

6
8

UP TO
ABOVE 25

8
10

SUBJECT TO FLEXING
FLEXIBLE CORDS AND CABLES

WIRE ARMOURED, SCREENED


OR TEXTILE REINFORCED FLEXIBLE
CABLES AND CORDS

FACTOR APPLIED TO O.D. OF CABLE TO


DETERMINE MINIMUM INTERNAL RADIUS OF BEND

Maximum spacing of supports for fixed wiring


OVERALL DIAMETER OF CABLES*

1
MM
NOT EXCEEDING 9
EXCEEDING 9 AND NOT EXCEEDING 15
EXCEEDING 15 AND NOT EXCEEDING 20
EXCEEDING 20 AND NOT EXCEEDING 40

MAXIMUM SPACING OF CLIPS


NON-ARMOURED PVC SHEATHED CABLES
ARMOURED CABLES AND CORRUGATED
ALUMINIUM SHEATHED CABLES
HORIZONTAL ++
VERTICAL ++
HORIZONTAL ++
VERTICAL ++
2
3
4
5
MM
MM
MM
MM
250
400
300
400
350
450
350
450
400
550
400
550
450
600

*Taken as the measurement of the major axis, in the case of flat cables.
++The spacings stated for horizontal runs may be applied also to run at an angle of more than 30 from the vertical.
For runs at an angle of 30 or less from the vertical, the vertical spacings are applicable.
Suggested minimum bending radius for power distribution cables
CABLE TYPE
XLPE & PVC INSULATED CABLES TO:
BS 6724 (INCLUDING FIRETUF POWER OHLS), BS 5467 & BS 6346.
PAPER INSULATED CABLES TO BS 6480:
Up to and including 8700/11000 volts
Above 8700/11000 volts up to and including 12700/22000 volts
19000/33000 volts
XLPE INSULATED CABLES TO BS 6622
Unarmoured
Armoured

*This also applies to individual cores of SL cables.

FACTOR APPLIED TO O.D. OF CABLE TO


DETERMINE MINIMUM INTERNAL RADIUS OF BEND
8
SINGLE CORE
MULTICORE
12
16
15
18

18*
21*

15
12

20
15

CURRENT RATINGS

REQUIREMENTS FOR INSTALLATION AND USE OF CABLES, FLEXIBLE


CABLES AND CORDS

CURRENT RATINGS

118

SINGLE CORE XLPE INSULATED 6350/11000 VOLT ARMOURED CABLES TO


BS6622 STRANDED COPPER CONDUCTORS
NOMINAL INSULATION ARMOUR
CONDUCTOR THICKNESS
WIRE
AREA
DIAMETER
MM2
50
70
95
120
150
185
240
300
400
500
630

MM
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

MM
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.5
2.5

APPROX. THICKNESS APPROX.


DIAMETER
OF
OVERALL
OVER
OVERSHEATH DIAMETER
ARMOUR
MM
MM
MM
24.9
1.8
28.5
26.6
1.9
30.4
28.3
1.9
32.1
29.9
2.0
33.9
32.1
2.1
36.3
33.9
2.1
38.1
36.3
2.2
40.7
38.6
2.2
43.0
41.7
2.4
46.5
45.9
2.5
50.9
49.8
2.6
55.0

APPROX.
CABLE
WEIGHT
KG/KM
1400
1500
1900
2100
2500
3000
3700
4300
5300
6500
8000

MINIMUM MAXIMUM MAXIMUM RESISTANCE


BENDING
ARMOUR
OF CONDUCTOR
RADIUS
RESISTANCE DC AT 20C DC AT 20C
AT 20C
MM
OHMS/KM OHMS/KM OHMS/KM
450
0.38
0.387
0.494
500
0.35
0.268
0.341
500
0.33
0.193
0.247
550
0.32
0.153
0.196
550
0.24
0.124
0.160
600
0.22
0.0991
0.128
650
0.21
0.0754
0.098
650
0.20
0.0601
0.079
700
0.19
0.0470
0.063
800
0.14
0.0355
0.051
850
0.13
0.0283
0.041

NOMINAL INDUCTANCE REACTANCE IMPEDANCE MAXIMUM MAXIMUM SUSTAINED CURRENT RATING MAXIMUM SYMMETRICAL SHORT MAXIMUM EARTH-FAULT
CONDUCTOR
+
AT 50HZ AT 90C CAPACITANCECHARGING

CIRCUIT CURRENT RATING


SHORT CURRENT RATING
AREA
+
+
CURRENT AT
NORMAL
VOLTAGE & LAID IN SINGLE IN AIR
FOR
FOR
FOR
FOR
FOR
FOR
FREQUENCY DIRECT WAY DUCTS
0.2 SECS 1.0 SECS 3.0 SECS 0.2 SECS 1.0 SECS 3.0 SECS
MM2 MH/KM OHMS/KM OHMS/KM F/KM AMP/KM AMP
AMP
AMP
KA
KA
KA
KA
KA
KA
50
0.430
0.134
0.512
0.24
0.49
221
220
251
15.2
6.8
3.9
15.2
6.8
3.9
70
0.400
0.127
0.364
0.28
0.56
270
261
310
21.9
9.8
5.6
17.2
7.7
4.4
95
0.380
0.120
0.274
0.32
0.64
321
306
376
30.4
13.6
7.8
18.3
8.2
4.7
120
0.370
0.115
0.227
0.36
0.71
363
341
431
38.5
17.2
9.9
19.5
8.7
5.0
150
0.360
0.113
0.195
0.39
0.77
410
375
490
47.3
21.1
12.2
25.7
11.5
6.6
185
0.350
0.108
0.167
0.43
0.85
455
410
562
59.3
26.5
15.3
27.3
12.2
7.0
240
0.330
0.104
0.143
0.48
0.96
520
460
650
78.1
34.9
20.1
29.3
13.1
7.6
300
0.320
0.100
0.128
0.53
1.06
580
500
740
98.0
43.7
25.2
31.5
14.1
8.7
400
0.310
0.097
0.116
0.59
1.18
650
531
840
>100
55.9
32.3
33.8
15.1
8.7
0.66
1.31
710
570
931
>100
70.6
40.7
46.5
20.8
12.0
0.108
0.096
0.310
500
0.290
0.092
0.101
0.74
1.47
761
620
1040
>100
90.8
52.6
50.3
22.5
13.0
630

+ Cables in touching trefoil arrangement.


Cables in touching trefoil or trefoil ducts.
Standard depth of laying:
0.8m.
Thermal resistivity of soil (g):
1.2K.m/W.
Standard ground temperature:
15C.
Ambient air temperature:
25C.
Maximum conductor temperature:
90C.
Short circuit ratings have been calculated on the following:Symmetrical fault, conductor temperature rise of 90C - 250C.
Earth fault, armour temperature rise of 80C - 200C.

119

NOMINAL INSULATION THICKNESS THICKNESS ARMOUR THICKNESS APPROX.


CONDUCTOR THICKNESS OF COPPER
OF
WIRE
OF
OVERALL
AREA
SCREEN EXTRUDED DIAMETER OVERSHEATH DIAMETER
TAPE
BEDDING
MM
MM
MM
MM
MM
MM
MM
25
3.4
0.075
1.9
2.5
2.4
50.1
35
3.4
0.075
1.9
2.5
2.5
52.9
50
3.4
0.075
2.1
2.5
2.6
56.0
70
3.4
0.075
2.1
2.5
2.7
59.9
95
3.4
0.075
2.2
2.5
2.8
64.1
120
3.4
0.075
2.4
2.5
3.0
68.2
150
3.4
0.075
2.4
2.5
3.1
71.4
185
3.4
0.075
2.5
2.5
3.2
75.7
240
3.4
0.075
2.5
3.15
3.4
82.6
300
3.4
0.075
2.5
3.15
3.6
88.0
400
3.4
0.075
2.5
3.15
3.8
95.1

APPROX.
CABLE
WEIGHT
KG/KM
4400
4900
5600
6500
7800
8900
10000
11600
14800
17300
20500

MINIMUM MAXIMUM MAXIMUM RESISTANCE


BENDING ARMOUR
OF CONDUCTOR
RADIUS RESISTANCE
AT 20C DC AT 20C AC AT 20C
MM
OHMS/KM OHMS/KM OHMS/KM
650
0.64
0.727
0.926
650
0.58
0.524
0.668
700
0.56
0.387
0.494
750
0.52
0.268
0.341
800
0.48
0.193
0.247
850
0.46
0.153
0.196
900
0.44
0.124
0.160
950
0.41
0.0991
0.128
1000
0.30
0.0754
0.099
1100
0.28
0.0601
0.080
1150
0.26
0.0470
0.065

NOMINAL INDUCTANCE REACTANCEIMPEDANCEMAXIMUMMAXIMUM ARMOUR SUSTAINED CURRENT RATING MAXIMUM SYMMETRICAL SHORT MAXIMUM EARTH-FAULT
CONDUCTOR
AT 50HZ AT 90C CAPACITANCE CHARGING LOSS AT 50HZ
CIRCUIT CURRENT RATING SHORT CURRENT RATING
AREA
CURRENTAT AND AT MAX.
NORMAL CURRENT
VOLTAGE & RATING LAID IN SINGLE IN AIR
FOR
FOR
FOR
FOR
FOR
FOR
FREQUENCY LAID DIRECT DIRECT WAY DUCTS
0.2 SECS 1.0 SECS 3.0 SECS 0.2 SECS 1.0 SECS 3.0 SECS
MM2 MH/KM OHMS/KM OHMS/KM F/KM AMP/KM KW/KM AMP
AMP
AMP
KA
KA
KA
KA
KA
KA
25
0.36
0.114
0.93
0.19
0.38
0.22
152
131
163
8.1
3.6
2.0
8.1
3.6
2.0
35
0.34
0.106
0.68
0.22
0.44
0.34
181
156
197
11.2
5.0
2.9
11.2
5.0
2.9
50
0.32
0.101
0.51
0.24
0.49
0.50
213
182
236
15.2
6.8
3.9
15.2
6.8
3.9
70
0.31
0.096
0.35
0.28
0.56
0.82
260
224
291
21.9
9.8
5.6
21.9
9.8
5.6
95
0.29
0.092
0.26
0.32
0.64
1.3
309
263
353
30.4
13.6
7.8
30.4
13.6
7.8
120
0.28
0.088
0.22
0.36
0.71
1.8
349
306
402
38.5
17.2
9.9
35.3
15.8
9.1
150
0.27
0.086
0.18
0.39
0.77
2.3
390
342
454
47.3
21.1
12.2
37.6
16.8
9.7
185
0.27
0.084
0.15
0.43
0.85
3.1
436
379
515
59.3
26.5
15.3
40.0
17.9
10.3
240
0.26
0.081
0.13
0.48
0.96
5.4
499
438
600
78.1
34.9
20.1
54.8
24.5
14.1
0.53
1.06
7.0
553
481
676
98.0
43.7
25.2
58.8
26.3
15.2
0.11
0.080
0.25
300
0.25
0.078
0.10
0.59
1.18
10.0
619
552
768
>100
55.9
32.3
63.7
28.5
16.5
400

Standard depth of laying:


Thermal resistivity of soil (g):
Standard ground temperature:
Ambient air temperature:
Maximum conductor temperature:

0.8m.
1.2K.m/W.
15C.
25C.
90C.

Short circuit ratings have been calculated on the following:Symmetrical fault, conductor temperature rise of 90C - 250C.
Earth fault, armour temperature rise of 80C - 200C.

CURRENT RATINGS

THREE CORE XLPE INSULATED 6350/11000 VOLTS ARMOURED CABLES TO


BS6622 STRANDED COPPER CONDUCTORS

CURRENT RATINGS

120

THREE CORE XLPE INSULATED 6350/11000 VOLTS ARMOURED CABLES TO


BS6622 STRANDED ALUMINIUM CONDUCTORS
NOMINAL INSULATION THICKNESS THICKNESS ARMOUR THICKNESS APPROX.
CONDUCTOR THICKNESS OF COPPER
OF
WIRE
OF
OVERALL
AREA
SCREEN EXTRUDED DIAMETER OVERSHEATH DIAMETER
TAPE
BEDDING
MM
MM
MM
MM
MM
MM
MM
25
3.4
0.075
1.9
2.5
2.4
50.1
35
3.4
0.075
1.9
2.5
2.5
52.9
50
3.4
0.075
2.1
2.5
2.6
56.0
70
3.4
0.075
2.1
2.5
2.7
59.9
95
3.4
0.075
2.2
2.5
2.8
64.1
120
3.4
0.075
2.4
2.5
3.0
68.2
150
3.4
0.075
2.4
2.5
3.1
71.4
185
3.4
0.075
2.5
2.5
3.2
75.7
240
3.4
0.075
2.5
3.15
3.4
82.6
300
3.4
0.075
2.5
3.15
3.6
88.0
400
3.4
0.075
2.5
3.15
3.8
95.1

APPROX.
CABLE
WEIGHT
KG/KM
3800
4100
4500
5300
5800
6400
7000
7800
9800
11000
13400

MINIMUM MAXIMUM MAXIMUM RESISTANCE


BENDING ARMOUR
OF CONDUCTOR
RADIUS RESISTANCE
AT 20C DC AT 20C AC AT 20C
MM
OHMS/KM OHMS/KM OHMS/KM
650
0.64
1.20
1.540
650
0.58
0.868
1.110
700
0.56
0.641
0.822
750
0.52
0.443
0.570
800
0.48
0.320
0.410
850
0.46
0.253
0.325
900
0.44
0.206
0.265
950
0.41
0.164
0.212
1000
0.30
0.125
0.161
1100
0.28
0.100
0.130
1150
0.26
0.0778
0.103

NOMINAL INDUCTANCE REACTANCEIMPEDANCEMAXIMUMMAXIMUM ARMOUR SUSTAINED CURRENT RATING MAXIMUM SYMMETRICAL SHORT MAXIMUM EARTH-FAULT
CONDUCTOR
AT 50HZ AT 90C CAPACITANCE CHARGING LOSS AT 50HZ
CIRCUIT CURRENT RATING SHORT CURRENT RATING
AREA
CURRENTAT AND AT MAX.
NORMAL CURRENT
VOLTAGE & RATING LAID IN SINGLE IN AIR
FOR
FOR
FOR
FOR
FOR
FOR
FREQUENCY LAID DIRECT DIRECT WAY DUCTS
0.2 SECS 1.0 SECS 3.0 SECS 0.2 SECS 1.0 SECS 3.0 SECS
MM2 MH/KM OHMS/KM OHMS/KM F/KM AMP/KM KW/KM AMP
AMP
AMP
KA
KA
KA
KA
KA
KA
25
0.36
0.114
1.54
0.19
0.38
0.14
118
101
127
5.2
2.3
1.3
5.2
2.3
1.3
35
0.34
0.106
1.12
0.22
0.44
0.21
141
121
153
7.2
3.2
1.8
7.2
3.2
1.8
50
0.32
0.101
0.83
0.24
0.49
0.31
166
141
183
9.7
4.3
2.5
9.7
4.6
2.5
70
0.31
0.096
0.58
0.28
0.56
0.50
202
174
226
14.1
6.3
3.6
14.1
6.3
3.6
95
0.29
0.092
0.42
0.32
0.64
0.77
241
205
274
19.5
8.7
5.0
19.5
8.1
5.0
120
0.28
0.088
0.34
0.36
0.71
1.1
272
239
314
24.7
11.0
6.3
24.7
11.0
6.3
150
0.27
0.086
0.28
0.39
0.77
1.4
304
267
354
30.3
13.5
7.8
30.3
13.5
7.8
185
0.27
0.084
0.23
0.43
0.85
1.9
343
297
404
38.1
17.0
9.8
38.1
17.0
9.8
240
0.26
0.081
0.18
0.48
0.96
3.3
395
347
473
50.1
22.4
12.9
50.1
22.4
12.9
0.53
1.06
4.4
440
383
536
62.8
28.1
16.2
58.8
26.3
15.2
0.15
0.080
0.25
300
0.25
0.078
0.13
0.59
1.18
6.5
500
446
618
80.1
35.9
20.7
63.7
28.5
16.5
400

Standard depth of laying:


Thermal resistivity of soil (g):
Standard ground temperature:
Ambient air temperature:
Maximum conductor temperature:

0.8m.
1.2K.m/W.
15C.
25C.
90C.

Short circuit ratings have been calculated on the following:Symmetrical fault, conductor temperature rise of 90C - 250C.
Earth fault, armour temperature rise of 80C - 200C.

121

Single core, EPR insulated, HOFR sheathed. BS6007 - 6381TQ


AMBIENT TEMPERATURE
RATING FACTOR

25
1.02

30
1.0

35
0.95

40
0.90

45
0.85

50
0.80

55
0.74

60
0.67

65
0.60

70
0.52

75
0.43

80
0.30

Ratings do not apply if the cable is protected by a semi-enclosed fuse to BS3036.


For further guidance refer to the 16th Edition IEE Wiring Regulations.
For ambient air temperatures other than 30C, the above factors should be applied.
Ambient temperature: 30C.
Conductor operating temperature: 85C.
Current Carrying Capacity (Amperes)
CONDUCTOR
CROSS SECTIONAL
AREA

1
MM2
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
600

REFERENCE METHOD 3
REFERENCE METHOD 1
REFERENCE METHOD 11
(ENCLOSED IN CONDUIT ETC.
(CLIPPED DIRECT)
(ON A PERFORATED CABLE TRAY)
IN OR ON A WALL)
HORIZONTAL OR VERTICAL
2 CABLES
3 OR 4 CABLES
2 CABLES
3 OR 4 CABLES
2 CABLES
3 OR 4 CABLES
SINGLE PHASE 3 PHASE A.C. SINGLE PHASE 3 PHASE A.C. SINGLE PHASE 3 PHASE A.C.
A.C. OR D.C.
A.C. OR D.C.
FLAT &
A.C. OR D.C.
FLAT &
FLAT &
TOUCHING OR
FLAT &
TOUCHING
TOUCHING
TREFOIL
TOUCHING
OR TREFOIL

2
AMP
40
52
72
96
127
157
190
242
293
339
372
428
510
593
719
835
975

3
AMP
36
46
63
85
112
138
167
213
258
298
334
379
443
506
602
689
791

4
AMP
45
59
81
108
143
177
215
274
332
384
442
519
607
695
827
946
1088

5
AMP
42
54
75
100
133
164
199
254
308
357
411
469
553
636
755
865
996

6
AMP
153
189
229
293
356
412
475
542
639
735
860
989
1143

7
AMP
140
174
211
269
327
379
437
499
589
679
798
918
162

REFERENCE METHOD 12
(FREE AIR)
SINGLE PHASE
A.C. OR D.C. OR
3 OR 4 CABLES
3 PHASE A.C.
FLAT SPACED
HORIZONTAL
OR VERTICAL
8
AMP
154
192
235
303
370
431
499
573
679
786
929
1081
1263

3 CABLES
TREFOIL
3 PHASE A.C.

9
AMP
134
167
204
262
320
373
432
495
587
680
799
919
1060

CURRENT RATINGS

TECHNICAL SPECIFICATIONS FOR 6381TQ

CURRENT RATINGS

122

FLEXIBLE CABLES AND CORDS TECHNICAL SPECIFICATIONS FOR 638*TQ


CURRENT CARRYING CAPACITY (Amperes)
AMBIENT TEMPERATURE
RATING FACTOR

25
1.02

30
1.02

35
0.95

40
0.90

45
0.85

50
0.80

55
0.74

60
0.67

65
0.60

70
0.52

75
0.43

80
0.30

Ratings do not apply if the cable is protected by a semi-enclosed fuse to BS3036.


For further guidance refer to the 16th Edition IEE Wiring Regulations.
For ambient air temperatures other than 30C, the above factors should be applied.
Current Carrying Capacity (Amperes)
CONDUCTOR CROSS
SECTIONAL AREA
MM2
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

D.C. OR SINGLE PHASE A.C.


(2 CORE CABLE, WITH OR WITHOUT
PROTECTIVE CONDUCTOR)
AMP
41
53
73
99
131
-

3 PHASE A.C.
(3 CORE, 4 CORE OR
5 CORE CABLE)
AMP
36
47
64
86
114
140
170
216
262
303
348
397
467
537
-

SINGLE PHASE A.C. OR D.C.


2 SINGLE CORE CABLES TOUCHING
AMP
192
240
297
354
414
476
540
645
741
885
1017
1190

Ambient temperature: 30C.


Conductor operating temperature: 85C.
Note: The current ratings tabulated are for cables in free air but may also be used for cables resting on a surface.

123

Applicable to: 318*Y, 218*Y, 2491YX, 309*Y, 318*P/TQ, 398*P, 380*Y, 380*P, 380*TQ, 219*Y.
Correction Factor for Ambient Temperature 60C rubber and PVC cords
AMBIENT TEMPERATURE
RATING FACTOR

35
0.91

40
0.82

45
0.71

50
0.58

55
0.41

85C rubber cords having a HOFR sheath or heat-resisting PVC sheath and for 90C heat resisting and PVC cords
AMBIENT TEMPERATURE
RATING FACTOR

35-50
1.0

55
0.96

60
0.83

65
0.67

70
0.47

180C rubber cords


AMBIENT TEMPERATURE
RATING FACTOR

35-150
1.0

155
0.92

160
0.82

165
0.71

170
0.57

175
0.40

BS6141 BS6500 Current Carrying Capacity (Amperes)


CONDUCTOR CROSS SECTIONAL AREA
1
MM2
0.5
0.75
1
1.25
1.5
2.5
4

CURRENT CARRYING CAPACITY (Amperes)


SINGLE PHASE A.C.
3 PHASE A.C.
2
3
AMP
AMP
3
3
6
6
10
10
13
16
16
25
20
32
25

Voltage Drop (per ampere per metre)


CONDUCTOR CROSS SECTIONAL AREA
1
MM2
0.5
0.75
1
1.25
1.5
2.5
4

D.C. SINGLE PHASE A.C.


2
MV
93
62
46
37
32
19
12

3 PHASE A.C.
3
MV
80
54
40
27
16
10

Note: The tabulated values above are for 60C rubber insulated and PVC insulated flexible cords and for other types
of flexible cords they are to be multiplied by the following factors:
For 85C rubber or PVC insulated: 1.09
180C rubber insulated: 1.31

CURRENT RATINGS

TECHNICAL SPECIFICATIONS FOR FLEXIBLE CORDS

CURRENT RATINGS

124

TRI-RATED - SWITCHGEAR WIRING CABLE


NO. OF CORES
& NOMINAL
CROSS SECTIONAL
AREA OF CONDUCTOR
NO X MM2
1 x 0.50
1 x 0.75
1 x 1.00
1 x 1.50
1 x 2.50
1 x 4.00
1 x 6.00
1 x 10.00
1 x 16.00
1 x 25.00
1 x 35.00
1 x 50.00
1 x 70.00
1 x 95.00
1 x 120.00
1 x 150.00
1 x 185.00
1 x 240.00
1 x 300.00

SINGLE CABLE

CURRENT RATING
2 CABLES BUNCHED

3 CABLES BUNCHED

AMP
11.50
16.00
19.00
24.00
32.00
43.00
56.00
79.00
105.00
141.00
178.00
217.00
276.00
337.00
400.00
457.00
526.00
634.00
730.00

AMP
10.00
14.00
16.50
20.00
28.00
37.00
49.00
69.00
91.00
123.00
154.00
188.00
239.00
292.00
347.00
396.00
454.00
546.00
610.00

AMP
7.00
10.50
12.50
16.00
22.00
29.00
39.00
57.00
76.00
104.00
131.00
162.00
208.00
257.00
305.00
350.00
405.00
489.00
560.00

MIXIMUM DC
CONDUCTOR
RESISTANCE@
20C
KM
39.00
26.00
19.50
13.30
7.98
4.95
3.30
1.91
1.12
0.780
0.554
0.386
0.272
0.206
0.161
0.129
0.106
0.0801
0.0641

NOTES

NOTES

You might also like