You are on page 1of 2

Import Text File Format Description

The import file must be in text file format. The cel file is a tab-delimited text file which contains following information: 1st row - Cel file header. This row is optional 2nd row - Field titles separated by tab character 3rd row onward [Field values separated by tab character The title row must contain the following fields in any order:
Field Names CELL UARFCN SC ARFCN BSIC LAT LON ANT_ORIENTATION or ANT_DIRECTION ANT_BEAM_WIDTH Description Cell Name. UARFCN (WCDMA only). Scrambling Code (WCDMA only) BCCH (GSM only). BSIC (GSM only) Latitude in decimal format e.g. 30.1232422 Longitude in decimal format e.g. 101.23242 Antenna direction in degree (Range 0 to 360) Antenna beam-width in degree (Range 1 to 360). If empty or zero, default value 60 will be used. This field value is used to set the angle of the sector [3]. For an omni cell, set this field to 360 to draw a circle object. Antenna height in meters. If empty or zero, default value 100m will be used. This field value is used to set the sector altitude from the ground [4]

Aexio GE Converter Quick Reference Guide

Object Label 1. Site Label

2. Cell Label

Description The site label is made of the cell name without the last character. Each cell record will have on Site label however if the preceding cell record belongs to the same site, no site label will be created. Cell label consists of two parts [Cell suffix] : [Carrier Info] - Cell suffix is the last character of the cell name - Carrier Info is SC (for WCDMA cell) or BCCH [BSIC] (for GSM cell)

The mandatory fields are used to draw the cell object in the GE map layer. Any additional fields will be shown in the pop-up balloon when the cell is selected.

ANT_HEIGHT

1 3 2 4

Note: Please find the sample cel files in the installation folder C:\Program Files\aexio\aexio GEConverter\Sample
For updates and help, please join the user community at http:\\www.aexiocommunity.com

2006-2007 Copyright Aexio Technologies Sdn. Bhd.

Applying Themes
GE Converter allows user to specify themes for a specified field in the import file. For example, the cel file has a field/column name SITE_STATUS where each cell can either has On Air or Planned value. You can set different color and sector radius for each of the site status. Follow the steps below to the apply themes in the GE Converter. 1. At the GE Converter Dialog, click the Themes.. button in the settings section. 2. In the ThemeSetting dialog, enter the FieldName of the columns where you want to apply the theme

Aexio GE Converter Quick Reference Guide

5. Enter the properties of the theme

4. Click Add to insert a new individual theme

6. Repeat step 4 & 5 for the Planned theme


2. Enter Field Name

3. Click the collection button to enter individual theme

Planned Cell

On Air Cell

3. Click on the Collection button to enter individual theme. 4. Click the Add button to insert a new individual theme 5. At the properties list box, enter the value of the theme e.g. On Air and set the Theme Color and sector radious for the theme.

2006-2007 Copyright Aexio Technologies Sdn. Bhd.

For updates and help, please join the user community at http:\\www.aexiocommunity.com