TOSHIBA

Ozone Measurement Data


Model: Toshiba Copier, DP-4500
An appliance was installed in the center of a closed room of approximately 1,000 cubic feet and was operated continuously. The ozone concentration was measured in accordance with the UL Standard 114, Sep., 1982, Safety for Office Appliances and Business Equipment by using type DY-1500 Dylec meter. The ozone concentration, temperature and relative humidity of test room are as follows; Hours of Operation 0 1/4 1/2 3/4 1 1-1/2 2 2-1/2 3 3-1/2 4 4-1/2 5 5-1/2 6 6-1/2 7 7-1/2 8 Concentration TemperatureHumidity of Ozone(ppm) (C) (% RH) 0.000 0.020 0.024 0.026 0.025 0.026 0.030 0.026 0.026 0.036 0.029 0.034 0.029 0.030 0.030 0.035 0.035 0.036 0.035 23 23 24 24 25 26 26 27 27 27 27 27 27 27 27 27 27 27 27 82 83 83 83 83 84 84 76 76 76 76 76 76 76 70 70 76 77 77

Condition of Test Test conducted with paper. Probe located approximately 5cm from top of ADU unit cover

Test Conducted :

On : Oct. 6, 2000 At : Toshiba Tec Corp., Yanagicho Works