TRAINING

WIN-S

ENGINE PROTECTION
ENGINE PROTECTION DEPENDING UPON THE IMPORTANCE OF THE OPERATING & SAFETY REQUIREMENTS IS CLASSIFIED TO DIFFERENT LEVELS. ALARM TRIP (BREAKER OPEN, AVR OFF, ENGINE STOPS AFTER 30 SECONDS) SHUTDOWN (BREAKER OPEN ENGINE STOP SIMULTANEOUSLY) START BLOCKING
1 TS-E/TRG/2000

TRAINING

WIN-S

LUB. OIL SYSTEM


LOW PRELUB SUMP LEVEL HIGH LUB OIL PRESSURE LUB OIL OIL DIFF. PRESSURE FILTER PRESSURE TEMPERATURE
0.5 BAR 1.5 800 2.5 3.5 C SET LEVEL START BLOCKING SHUTDOWN ALARM

2 TS-E/TRG/2000

TRAINING

WIN-S

COOLING WATER SYSTEM

LOW HT WATER PRESSURE HIGH LT WATER PRESSURE LEVEL HT/LT EXPANSION VESSEL HT WATER TEMPERATURE TEMPERATURE 2.0 BAR LEVEL 500 105 C 1000 C SET ALARMBLOCKING START SHUTDOWN

3 TS-E/TRG/2000

TRAINING

WIN-S

OVERSPEED TEMPERATURE TURNING OIL PRESSURE FUELNTC GEAR AIR PRESSURE HIGH FUELOIL TEMPERATURE LOW STARTINGDIFF.PRESSURE NTC OIL ENGAGED FUEL OIL PRESSURE CHARGE AIR HOT BOX LEAKAGE IN TEMPERATURE
INLET 95 145 DESPEMES LIMIT LEVEL 1.5 C 4 BAR 2.0 80 BAR BAR 70 0 CSWITCH (OR) 860 RPM 180BARSET (ELECT)OUTLET 0.5 BAR LIMIT SWITCH START SHUTDOWN (MECH) 885 RPM ALARMBLOCKING ELECTRONIC GOVERNOR SHUTDOWN

4 TS-E/TRG/2000

TRAINING

WIN-S

ENGINE BEARING TEMPERATURE 1000 C ALARM 1200 C SHUTDOWN

EXHAUST GAS TEMPERATURE 5500 C ALARM 5800 C SHUTDOWN DEVIATION ALARM

5 TS-E/TRG/2000

TRAINING

WIN-S

ELECTRICAL FAULTS
SHUTDOWN - DIFFERENTIAL - EARTH FAULT - ALT. BRG. HIGH TEMP. TRIP

- ALL OTHER FAULTS (INCLUDING ALT. WDG. HIGH TEMP)

6 TS-E/TRG/2000