Ceramic Insulators Livorno S.r.l.

Via F.Filzi n 31 57122 Livorno Italy e-mail cil@ceramicinsulators.it tel +39 0586420330 fax 0586 411014

UNI EN ISO 9001

CERTIFICATE OF TEST
AQ002 Rev 0 del 17/01/2008 Pagina 1 di 1

Certificate of test n: Customer: Order n: Insulator mod. 31087 + 31376 Test purpose:

77 date: 19 / 02 / 2010 AK-AY ELEKTRIK DIS TICARET KOLLEKTIF 76-CIL-K-09 date: 23 / 12 / 2009 Customers ref. IEC ref. C8 1300 n pieces 41

Inspection of the insulator to verify the conformity with the requirements I.E.C. 168 2001-04

Test in accordance with:

Description of the tests: - mechanical routine test - temperature cycle test - visual examination

galvanizing test dimension control porosity test

mechanical test

Mechanical routine test (cantilever) The test has been carried out at 60% of the guaranteed breaking load in 4 directions at 90 using an extension piece (H=600 mm.) fixed on the top Insulator mod. test load (daN) time (min.) number of units tested failed passed 31087 + 31376 + ext. 400 1 41 0 41 Thermal test Insulator mod.

n of cycles

period (min.)

31087 + 31376 3 30 The test has been carried out on insulators of the same batch Mechanical failing load (cantilever) Insulator mod. guaranteed bending strength (daN) 31087 + 31376 800

temperature (C) dif. hot cold 50 65 15

number of units tested failed passed 1 0 1

mechanical strength remarks (daN) 1 1085 porcelain failure The test has been carried out on insulators of the same batch

pieces (n)

Porosity test Carried out on freshly broken fragments of insulators under a pressure of 20Mpa for 15 hr Result: no dye penetration observed. Galvanizing test The determination of the mass of zinc has been carried out by the magnetic test method Result: thickness of the zinc coating 110 150 micron. Dimension control Conforming to the drawing and relevant tolerances. (Total creepage distance 11230 mm.) Visual examination Satisfactory Ceramic Insulators Livorno S.r.l.