Interpretation: VIlI-1-86-36
Thickness
Question: Are full welded heattransferplates of plate-typeheat UG-l6(b)(2) from the ' / 6 in. minimum wall thickness requirements? Reply:Yes.
Interpretation: Vlll-1-86-37
March 5, 1986
Question: During the fabrication of a nonimpact tested pressure vessel made from SA-5 1 6 Grade 70 that is 5 in. thick, normalization of the material is conducted by the fabricator as a part of a hot forming process. In order to satisfy the requirements UCS-85: of (a) are mill test specimens required to have the heat treatment associated with the hot forming simulated? (b) is it required that the manufacturer define for the mill the anticipated cooling rate from the critical temperature during the hot forming operation? Reply: (a)Yes. (b) Yes.
Interpretation: VIlI-1-86-38
Question: Is it a requirementof Section VIII, Division 1, that the manufacturer of Code items shall examine the material test report or certificate of compliance (when these documents are required) and shall determine that it represents the material and meets the requirements of the material specification? Reply: Yes.
233
COPYRIGHT American Society of Mechanical Engineers Licensed by Information Handling Services
Section VIII-1
- Interpretations No. 32
Vlll-1-83-77R. Vlll-1-86-27R
Revisions to Interpretations Published in Previous Volumes The following revised interpretations supercede issued interpretations VIII-1-83-77, VIII-1-86-27, MII-1-89-86, and VIII-1-92-77, which originally publishedin Interpretations Volumes 12,18, were 25, and 31, respectively, but are now no longer valid.
Interpretation: Vlll-1-83-77R
3, 1992
C82-679*
Question: May electric resistance welded (ERW) pipe be usedfor the shell of a pressurevessel designed for lethal service under UW-2(a) in Section VIII, Division 1whether or not radiographic examination is performed on the ERW welded seam? Reply: No. See UW-2(a). The provisions of UW-2(a)(2) and (3) do not apply.
Interpretation: VIII-1-86-27R
Subject: Section
ment
Treat-
C85-140*
Question: For vessels built to rules of UCS-85(b) in Section VIII, Division 1, doesthe term the heat treatment include heating for the sole purpose of hot forming? Reply: Yes.
549
Errata
Errata
Volume 19 Interpretation VIII-1-86-36 Volume 29 Interpretation VIII1-89-264
In rhe third line of Question (5), correct 3:lO taper fa read 3:l taper
633