Is-limiter The world's fastest switching device
Reduces substation cost Solves short-circuit problems in new substations and substation extensions Optimum solution for interconnection of switchgears and substations In most cases the only technical solution Reliability and function proofed in thousands of installations Worldwide in service The peak short-circuit current will never be reached The short-circuit current is limited at the very first current rise
Customers:
Industry
Paper mills Refineries Chemical industries Car industries Power stations Steel-, Aluminium mills On-Off-shore platforms Ships / Vessels
T0
T1
T2
T3
250 kA i
50 kA
50kA x x 2
125 kA
i1
50 kA
50 kA
50kA x x 2
125 kA
50 kA
i1
50 kA
50 kA
50kA x x 2
125 kA
50 kA
i1
50 kA
50 kA
50kA x x 2
125 kA
i = i1 + i2 with Is-limiter
i1 i2
50 kA
IAC: A FLR
Self monitoring Redundancy (for each phase one independent system) Protection against EMI
EMC tested according to IEC 61000 Special current transformers (low impedance shield between primary and secondary winding) Filters for incoming / outgoing wires Special tripping and measuring wires (each pair tightly twisted and protected by steel conduit)
Test equipment
i 1
i 1
ilimit
i 1
ilimit ^ (di/dt)
^ = logical and
1 Short-circuit current without IS-limiter 2 Short-circuit current - IS-limiter tripped -
(di )2 dt
ilimit
i 1
ilimit ^ (di/dt)
^ = logical and
1 Short-circuit current without IS-limiter 2 Short-circuit current - IS-limiter tripped -
(di )2 dt
ilimit
(di )3 dt
i
iC
iB iA
T0
T1T2 T3
T4
Advantages:
Improving power quality Increasing the reliability of the system Reduction of the network-impedance Optimal load flow Existing busbar system and cabling have not to be changed
Advantages:
Generator can be connected independent on the shortcircuit capability of the system Existing busbar and cable systems have not to be changed No need of expensive generator breaker
Advantages:
Avoid copper losses of the reactor Avoid voltage drop of the reactor No electromagnetical field of the reactor Greenhouse aspects (CO2 and heating)
Private / industrial generator feeder can be connected to the fully loaded grid Selective tripping of the IS-limiter (IS-limiter will operate only for short-circuit faults in the grid 1 ; will not operate in the grid 2 )
Advantages:
Only IS-limiters close to fault location trip Existing busbar and cable systems have not to be changed Reduction of the network-impedance Optimal load flow Greenhouse aspects (CO2 and heating)