EMUA Installation Instruction:

EMUA is installed at the bottom of BTS3900L cabinet. For the reason of heat dissipation, gap need to be kept between BBU and EMUA and between EMUA and the Bottom of Rack.

3|Page

EMUA Quick Installation Manual for BTS3900L

EMUA Power and Signal Cable Connection Instruction:

The transmission cable and power cable are connected according to this graph. For the transmission cable, the two ends are with different type. One end is RS485 which connects to RS485 port on EMUA and the other end is RJ45 which connects to UPEN (MON1).

1. Transmission cable connection: from RS485 on EMUA to MON1 on UPEU. 2. Power cable connection: from PWR1 on EMUA to SPARE PORT on DCDU.

*If there are two BBUs in one cabinet, connect EMUA to the BBU which connects to U2100. If there is no U2100, connect to the BBU which connects to U900.

4|Page

EMUA Quick Installation Manual for BTS3900L

EMUA Alarm Cable Connection Instruction:

Alarm Cables are connected from EMUA to DDF (new), and cascaded the new DDF to the existing DDF which connected to Sensors. In the above graph, the new DDF are shown in red colour, and the existing DDF are shown in blue colour.

The details of the cable pairs need to be done according to the following Tables.

Normally one site doesnt have all the sensors installed currently. So only the Sensor whose name can be found from the existing DDF labels need to be connected.