The EVI7 S9 system by AMISCO includes a wide range of solenoids, coils and operators, designed for pneumatic valves. All solenoids of this system have the guide tube with a diameter of 9 mm and the plunger with a diameter of 8 mm. The system is designed for use with air.
Please contact Amisco for use with other media. All given information are subjected to changes without notice.
Solenoid System
THREAD VERSION
COIL
The coil is available in different sizes and with different electrical terminations. Types, power and other characteristics are described in the following pages. All coils feature: heat resistant bobbin moulded with 30% glass filled thermoplastic polyester material class H wire 200C according to IEC 60317-13 built-in magnetic yoke made by low carbon iron encapsulation with high quality specially designed glass filled nylon (thermoset material on demand for 22 mm coil). The use of other materials is possible upon special agreements. All coils are rated to class F and to IP 65 (with connector). The coil is designed and constructed in accordance to EN 60204.1 and VDE 0580 and it is suitable for industrial ambient conditions. For use in special ambients with high humidity, we suggest the sealed or thermoset version; at any case, please, take contact with Amisco. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex nA II 3 GD T4 or T5). GAS: Ex nA IIC Tx Gc DUST: Ex tc IIIC Tx Dc For further information about Atex versions, see the ATEX Products catalogue.
OPERATOR
Plunger and core are made by a magnetic stainless steel specially designed for solenoid applications. The guide tube is made with brass (stainless steel is possible upon special agreement). The plunger is normally equipped with NBR rubber seals. Other sealing materials like FKM are available upon demand. The armature assembly is designed for more than 50x106 cycles.
SOLENOID SYSTEM
for 2/2 and 3/2 way Normally Closed and Normally Open valves
Characteristics Rated power DC Inrush power AC Rated power AC Coil temperature rise W VA VA C 35 40 3
DC 4,2 6,5
AC (50 Hz)
AC (60 Hz)
7,5 5 45 50 70 80 45 55
12,5 8,5 85 95
6,5 4,2 35 45
10,5 7 70 80
Operator S9
Code 3/2 way NC Flange 3/2 way NC Thread 2/2 way NC Flange 2/2 way NC Thread 3/2 way NO Flange (Top inlet) 3/2 way NO Thread (Top inlet) 3/2 way NO Thread (Bottom inlet) 09L... 09F... 09L... 09F... 09L... 09F... 09F... Characteristics Inlet orifice Exhaust orifice Working pressure Inlet orifice Working pressure Inlet orifice Working pressure Inlet orifice Working pressure mm mm bar mm bar mm bar mm bar 1,2 1,4 1,5 1,2 1,5 1,2 1,5
010 010 010 010 010 010 010 1,2 1,4 1,5 1,2 1,5 1,2 1,5
010 010 010 010 010 010 010 1,45 1,45 1,45 1,45 07 1,2 010 1,45 1,45 1,45
Note:
Voltage tolerance: Temperature range: Duty cycle: 10% 20C +50C 100% Other voltages on request
2
Standard voltages:
CODE 0709S...
8.15 +0.05 0
1.5
M3
14
8.5
29.5+0.3 -0.1
7.370.3
6.30.1 (X3)
CODE 0709D...
3.5
29.5
28
0.8
5.5
10.6 17.5 11
0,8
9.1 +0.05 -0
6.30.1
15
CODE 0709C...
29.5+0.3 -0.1
21
CODE 0709G...
M3
15
8.5
30.5+0.3 -0.1
28
6.30.1 (X3)
CODE 0709E...
16
+0.05 8.15 0
1.5
M3
15
8.5
28
6.30.1 (X3)
CODE 0709F...
16
+0.05 8.15 0
1.5
M3
15
8.5
28
6.30.1 (X3)
CODE 3009D...
21.5
16
14.5
8.15 +0.05 -0
1.3
M3
37.5
15
26.3
18 28 29.5
28
CODE 3009C...
16
1.3 5005
8.15 +0.05 -0
16
26.3
30
20
R1
.5
28 29.5 +0.3 -0
28
C O I L
C O D I N G
S P E C I F I C AT I O N S
CODE:
TYPE 07 = EVI 7 30 = EVI 30 COIL BORING 09 = 9 mm ELECTRICAL CONNECTION for EVI 7 for EVI 30 C = Flying Leads D = DIN 43650 A D = DIN 43650 B C = Flying Leads E = AMP 6.3x0.8mm Epoxy Sealed Version F = AMP 6.3x0.8mm UL Version G = AMP 6.3x0.8mm Sealed Version S = AMP 6.3x0.8mm SUPPLY CURRENT A = Alternating current (A.C.) D = Direct current (D.C.) R = Rectified alternating current (R.A.C.)
NOMINAL VOLTAGE Example: 024 = 24V 220 = 220 V EVI 30 S9 WINDING CODE Nominal Voltage Power Winding Code 12VDC 24VDC 24VAC 110VAC 230VAC 2W 4,5W 2W 4,5W 3VA 5VA 3VA 5VA 3VA 5VA 01 05 01 06 08 02 07 02 04 01
EVI 7 S9 WINDING CODE Nominal Voltage Power Winding Code 12VDC 3W 4,2W 6,5W 3W 4,2W 6,5W 5VA 8,5VA 5VA 8,5VA 5VA 8,5VA 03 06 04 03 06 04 01 02 01 02 03 01
24VDC
CUSTOMER LOGO
6.9
M8X0.75 M5
5 9.04 MAX 9.04 MAX 38.9 CORSA 0.45 0.65 4 4 8 10.8 M12X0.5 M8X0.75 5 5 CORSA 0.45 0.65 9.04 MAX 38.9 2.8 OR 10X1 CORSA 0.45 0.65 4 2.8 4 8 10.8 M12X0.5 5.3 36.5 CH 13 5.3 36.5 CH 13
1
5.3 4 8 10.4 12 f9 OR 10X1
3/2 NC
6.9
9.04 MAX
2/2 NC
1.3
4 8 10.4 12 f9
2/2 NC OPERATOR
2.7 h11
1.3
9.04 MAX
CORSA 0.30.7
M8x0.5 9 h8
2.7 h11
1.3
2.8 8 10.8
OR 10X1
25 M8X0.75 5 4
8 10.4 12 f9
OR 10X1
M12X0.5
2.7 h11
1.3
8 10.4 12 f9
8 10.8 M12X0.5
2.8
C O I L
Type
C O D I N G
Function
S P E C I F I C AT I O N S
Inlet orifice
1,2 mm
Seals
NBR FKM
Operator Code
09L02401A3CNN 09L02401A3CVN 09L07170A3CNN 09L07171A3CVN 09L02402A3CNN 09L02402A3CVN 09L02600A2CNN 09L02600A2CVN 09L02600A2CNN 09L02600A2CVN 09L02600A2CNN 09L02600A2CVN 09L02403A3ONN 09L02403A3OVN 09F07350A3CNN 09F07350A3CVN 09F07210A3CNN 09F07212A3CVN 09F07360A3CNN 09F07360A3CVN 09F07370A2CNN 09F07370A2CVN 09F07370A2CNN 09F07370A2CVN 09F07370A2CNN 09F07370A2CVN 09F07401A3ONN 09F07403A3OVN 09F11100A3ONN 09F11101A3OVN
3/2 NC
1,4 mm
NBR FKM
1,5 mm
NBR FKM
FLANGE
1,2 mm
NBR FKM
2/2 NC
1,4 mm
NBR FKM
1,5 mm
NBR FKM
3/2 NO
(Top Inlet)
1,45 mm
NBR FKM
1,2 mm
NBR FKM
3/2 NC
1,4 mm
NBR FKM
1,5 mm
NBR FKM
1,2 mm
NBR FKM
THREAD
2/2 NC 1,4 mm
NBR FKM
1,5 mm
NBR FKM
3/2 NO
(Top Inlet)
1,45 mm
NBR FKM
3/2 NO
(Bottom Inlet)
1,2 mm
NBR FKM
Contact Amisco for operator S9 large orifice (< 6 mm), or for special version. FASTENING NUTS (Note: tightening torque max 0.6 Nm) Plastic knurled nut Cod. 540238
Cod. 540270
Certificates
10
w w w. a m i s c o . i t
AMISCO S.p.A. Via Piaggio, 70 20037 Paderno Dugnano (Mi) Italy Tel. +39 02.99.00.181 Fax +39 02.99.00.18.60 amisco@amisco.it
Rev. 3/2013