You are on page 1of 60

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7858

25/07/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCP5113-10

1pc

10mm X 4 X Single leg sling c/w soft eyes at both ends

1.2 tonnes

LOCATION: SUBSEA 2ND BOP WORKSHOP


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Broken wires & kink

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 25/07/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7859

25/07/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCP5115-6

1pc

12mm X 4 X Single leg sling c/w soft eyes at both ends

2 tonnes

LOCATION: SUBSEA 2ND BOP WORKSHOP


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Permanent bend & exposed core


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 25/07/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7860

28/07/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: F1-6136/4

1pc

16mm X 3.03mtrs X Single leg sling c/w hard eyes at both ends

3.3 tonnes

LOCATION: DRILL FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Permanent bend & exposed core


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/07/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7861

28/07/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: 963902-0-1-6

1pc

16mm X 20ft X Single leg sling c/w soft eyes at both ends

3.9 tonnes

LOCATION: DRILL FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Permanent bend & exposed core


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/07/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7862

28/07/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCP 5134-4

1set

12mm X 4ft X 2 legged sling c/w master link assembly

2.8 tonnes

LOCATION: DRILL FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Master link does not conform to the Minimum dimension 270mm X 140mm
(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/07/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7863

Date of Examination

Examiner

Qualifications

28/07/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCP 5142-1

1set

20mm X 4ft X 2 legged sling c/w master link assembly

10.5 tonnes

LOCATION: DRILL FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Master link does not conform to the Minimum dimension 270mm X 140mm
(No t fit for Use) Name and address of equipment owner: Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/07/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7864

28/07/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: 963902-0-8-36

1pc

13mm X 20ft X single leg sling c/w soft eye at both ends

3.9 tonnes

LOCATION: DRILL FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Permanent Bend and & Exposed core


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/07/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7865

Date of Examination

Examiner

Qualifications

01/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCP 5141-1

1set

12mm X 4ft X 4 legged sling c/w quad master link assembly with ferrule secured thimble eyes at all ends

4.2 tonnes @ 0-90o

LOCATION: RISER DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Master link does not conform to the Minimum dimension 270mm X 140mm, Sling diameter is less than 13mm
(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7866

Date of Examination

Examiner

Qualifications

02/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: 963902-0-8-17

1pc

1/2 X 12ft X single leg sling c/w soft eye at both ends

2.5 tonnes

LOCATION: MECHANIC WORKSHOP


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Corroded & Exposed core

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 02/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7867

Date of Examination

Examiner

Qualifications

02/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCP 5113-9

1pc

10mm X 4ft X single leg sling c/w soft eye at both ends

1.4 tonnes

LOCATION: MECHANIC WORKSHOP


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Permanent Bend and & Exposed core


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 02/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7868

10/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: 963902-0-8-1

1pc

1/2" X 12ft X single leg sling c/w soft eye at both ends

2.5 tonnes

LOCATION: MUD PUMP ROOM


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Corroded and Badly Kinked

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 10/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7869

Date of Examination

Examiner

Qualifications

12/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCP 5134-1

1set

12mm X 4ft X 2 legged sling c/w master link assembly with ferrule secured thimble eyes at all ends

2.8 tonnes

LOCATION: RIGGING LOFT PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Master link does not conform to the Minimum dimension 270mm X 140mm, Sling diameter is less than 13mm
(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 12/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7870

12/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCP 5134-2

1set

12mm X 4ft X 2 legged sling c/w master link assembly with ferrule secured thimble eyes at all ends

2.8 tonnes

LOCATION: RIGGING LOFT PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Master link does not conform to the Minimum dimension 270mm X 140mm, Sling diameter is less than 13mm
(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 12/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7871

12/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCP 5134-3

1set

12mm X 4ft X 2 legged sling c/w master link assembly with ferrule secured thimble eyes at all ends

2.8 tonnes

LOCATION: RIGGING LOFT PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Master link does not conform to the Minimum dimension 270mm X 140mm, Sling diameter is less than 13mm
(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 12/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7872

Date of Examination

Examiner

Qualifications

12/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCP 5134-5

1set

12mm X 4ft X 2 legged sling c/w master link assembly with ferrule secured thimble eyes at all ends

2.8 tonnes

LOCATION: RIGGING LOFT PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Master link does not conform to the Minimum dimension 270mm X 140mm, Sling diameter is less than 13mm
(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 12/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7873

12/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCP 5140-3

1set

10mm X 4ft X 4 legged sling c/w quad master link assembly with ferrule secured thimble eyes at all ends

2.8 tonnes

LOCATION: RIGGING LOFT PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Master link does not conform to the Minimum dimension 270mm X 140mm, Sling diameter is less than 13mm
(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 12/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7874

13/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: SL 1

1pc

20mm X 9.2mtrs X Single leg sling c/w soft eyes at both ends

5.1 tonnes

LOCATION: RIGGING LOFT PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Broken wires found on eyes

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 13/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7875

13/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: SL 2

1pc

20mm X 9.2mtrs X Single leg sling c/w soft eyes at both ends

5.1 tonnes

LOCATION: RIGGING LOFT PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Broken wires found on eyes

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 13/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7876

13/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCP 1393-41

1pc

16mm X 9.16mtrs X Single leg sling c/w soft eyes at both ends

3 tonnes

LOCATION: RIGGING LOFT PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Permanent Bend and Exposed core


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 13/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7877

Date of Examination

Examiner

Qualifications

13/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCP 1393-42

1pc

16mm X 9.16mtrs X Single leg sling c/w soft eyes at both ends

3 tonnes

LOCATION: RIGGING LOFT PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Permanent Bend and Exposed core


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 13/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7878

Date of Examination

Examiner

Qualifications

13/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: OSL/PD 241

1pc

28mm X 10ft X Single leg sling c/w soft eyes at both ends

10.1 tonnes

LOCATION: RIGGING LOFT PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Badly corroded

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 13/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7879

Date of Examination

Examiner

Qualifications

13/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: OSL/PD 238

1pc

28mm X 10ft X Single leg sling c/w soft eyes at both ends

10.1 tonnes

LOCATION: RIGGING LOFT PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Badly corroded

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 13/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7880

13/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: OSL/PD 235

1pc

28mm X 10ft X Single leg sling c/w soft eyes at both ends

10.1 tonnes

LOCATION: RIGGING LOFT PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Badly corroded

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 13/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7881

12/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCP 5140-4

1set

10mm X 4ft X 4 legged sling c/w quad master link assembly

2.5 tonnes

LOCATION: RIGGING LOFT PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Master link does not conform to the Minimum dimension 270mm X 140mm, Sling Diameter is less than 13mm
(No t fit for Use) Name and address of equipment owner: Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 12/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7882

12/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCP 5141-4

1set

10mm X 4ft X 4 legged sling c/w quad master link assembly

2.5 tonnes

LOCATION: RIGGING LOFT PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Master link does not conform to the Minimum dimension 270mm X 140mm, Sling Diameter is less than 13mm
(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 12/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7883

Date of Examination

Examiner

Qualifications

12/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCP 5141-3

1set

12mm X 4ft X 4 legged sling c/w quad master link assembly

2.5 tonnes

LOCATION: RIGGING LOFT PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Master link does not conform to the Minimum dimension 270mm X 140mm, Sling Diameter is less than 13mm
(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 12/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7884

12/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCP 5141-2

1set

12mm X 4ft X 4 legged sling c/w quad master link assembly

2.5 tonnes

LOCATION: RIGGING LOFT PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Master link does not conform to the Minimum dimension 270mm X 140mm, Sling Diameter is less than 13mm
(No t fit for Use) Name and address of equipment owner: Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 12/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7885

12/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCP 5140-2

1set

10mm X 4ft X 4 legged sling c/w quad master link assembly

2.5 tonnes

LOCATION: RIGGING LOFT PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Master link does not conform to the Minimum dimension 270mm X 140mm, Sling Diameter is less than 13mm
(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 12/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7886

Date of Examination

Examiner

Qualifications

15/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCQ 1393-17

1pc

16mm X 9.16mtrs X single leg sling c/w soft eye at both ends

3 tonnes

LOCATION: RISER DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Kink & Exposed core

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 15/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7887

15/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCQ 1393-17A

1pc

16mm X 9.16mtrs X single leg sling c/w soft eye at both ends

3 tonnes

LOCATION: RISER DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Kink & Exposed core

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 15/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7888

Date of Examination

Examiner

Qualifications

15/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: BTCQ 1393-21

1pc

16mm X 9.16mtrs X single leg sling c/w soft eye at both ends

3 tonnes

LOCATION: RISER DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Kink & Exposed core

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 15/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7889

Date of Examination

Examiner

Qualifications

15/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: PB/SL/05

20mm X 1.67mtrs X 2 pt in Basket Hitch c/w hard eye both ends

6.7 tonnes

LOCATION: RISER DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Loose thimble

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 15/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7890

Date of Examination

Examiner

Qualifications

27/07/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment SHACKLE

SWL

Shackle #:
S1

1pc

Safety Pin Bow Shackle

3.25 tonnes

LOCATION: MONKEY BOARD


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No Manufacturers name or logo


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 27/07/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7891

27/07/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment SHACKLE

SWL

Shackle #:
S2

1pc

Safety Pin Bow Shackle

3.25 tonnes

LOCATION: MONKEY BOARD


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No Manufacturers name or logo


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 27/07/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7892

Date of Examination

Examiner

Qualifications

27/07/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment SHACKLE

SWL

Shackle #:
S3

1pc

Safety Pin Bow Shackle

3.25 tonnes

LOCATION: MONKEY BOARD


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No Manufacturers name or logo


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 27/07/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7893

Date of Examination

Examiner

Qualifications

27/07/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment SHACKLE

SWL

Shackle #:
S4

1pc

Safety Pin Bow Shackle

3.25 tonnes

LOCATION: MONKEY BOARD


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No Manufacturers name or logo


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 27/07/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7894

28/07/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment SHACKLE

SWL

Shackle #:
P4

1pc

Safety Pin Bow Shackle

8.5 tonnes

LOCATION: MONKEY BOARD


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No Manufacturers name or logo


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/07/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7895

Date of Examination

Examiner

Qualifications

28/07/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment SHACKLE

SWL

Shackle #:
P7

1pc

Safety Pin Bow Shackle

17 tonnes

LOCATION: MONKEY BOARD


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Wrong pin used

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 28/07/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7896

Date of Examination

Examiner

Qualifications

01/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment SHACKLE

SWL

Shackle #:
P17

1pc

Safety Pin Bow Shackle

12 tonnes

LOCATION: RISER DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No Manufacturers name or logo on shackle pin


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7897

02/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment SHACKLE

SWL

Shackle #:
P19

1pc

Safety Pin Bow Shackle

3.25 tonnes

LOCATION: MECHANIC WORKSOP


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No Manufacturers name or logo on shackle pin


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 02/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7898

Date of Examination

Examiner

Qualifications

02/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment SHACKLE

SWL

Shackle #:
P 20

1pc

Safety Pin Bow Shackle

3.25 tonnes

LOCATION: MECHANIC WORKSOP


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No Manufacturers name or logo on shackle pin


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 02/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7899

06/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment SHACKLE

SWL

Shackle #:
BS 1

1pc

Safety Pin Bow Shackle

9.5 tonnes

LOCATION: BOSUN STORE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No Manufacturers name or logo on shackle pin


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7900

Date of Examination

Examiner

Qualifications

06/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment SHACKLE

SWL

Shackle #:
BS 2

1pc

Safety Pin Bow Shackle

9.5 tonnes

LOCATION: BOSUN STORE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No Manufacturers name or logo on shackle pin


(No t fit for Use) Name and address of equipment owner: Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7901

19/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment SHACKLE

SWL

Shackle #:
A8

1pc

Safety Pin Bow Shackle

3.25 tonnes

LOCATION: SACK STORE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No Manufacturers name or logo on shackle


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 19/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7902

19/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment SHACKLE

SWL

Shackle #:
A6

1pc

Safety Pin Bow Shackle

3.25 tonnes

LOCATION: SACK STORE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No Manufacturers name or logo on shackle


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 19/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7903

19/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment SHACKLE

SWL

Shackle #:
A5

1pc

Safety Pin Bow Shackle

3.25 tonnes

LOCATION: SACK STORE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No Manufacturers name or logo on shackle


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 19/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7904

Date of Examination

Examiner

Qualifications

19/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment SHACKLE

SWL

Shackle #:
A3

1pc

Safety Pin Bow Shackle

3.25 tonnes

LOCATION: SACK STORE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No Manufacturers name or logo on shackle


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 19/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7905

19/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment SHACKLE

SWL

Shackle #:
A1

1pc

Safety Pin Bow Shackle

3.25 tonnes

LOCATION: SACK STORE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No Manufacturers name or logo on shackle


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 19/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7906

Date of Examination

Examiner

Qualifications

19/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment SHACKLE

SWL

Shackle #:
A4

1pc

Safety Pin Bow Shackle

3.25 tonnes

LOCATION: SACK STORE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No Manufacturers name or logo on shackle


(No t fit for Use) Name and address of equipment owner : Pacific Drilling

Remove from service

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 19/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7907

Date of Examination

Examiner

Qualifications

28/07/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment SWIVEL HOIST RING

SWL

BTCP 8628-8

Swivel Hoist Ring

1.13 tonnes

LOCATION: DRILL FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Bent Load Pin due to overload

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 28/07/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7908

04/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment EYE BOLT

SWL

PBE 4

Eye Bolt

0.34 tonne

LOCATION: MECHANIC WORKSHOP


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Worn Thread

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 04/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7909

02/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment BEAM TROLLEY

SWL

S1809/07

Beam Trolley

1 tonne

LOCATION: STBD SIDE ENGINE ROOM


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Deformed Lifting Point

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 02/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7910

28/07/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment CHAIN HOIST

SWL

BTCP 5557-2

6mm X 9.3mtrs Manual Chain Hoist, single Fall

1 tonne

LOCATION: DRILL FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Throat Opening

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 28/07/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7911

06/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment CHAIN HOIST

SWL

BTCP 5558-6

8mm X 30ft Manual Chain Hoist, single Fall

2 tonnes

LOCATION: BOSUN STORE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Faulty Latch

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 06/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7912

06/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment CHAIN HOIST

SWL

BTCP 5558-4

8mm X 30ft Manual Chain Hoist, single Fall

2 tonnes

LOCATION: BOSUN STORE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Faulty Latch

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 06/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7913

12/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment CHAIN HOIST

SWL

BTCP 5553-1

9mm X 21.8ft Manual Chain Hoist, four Fall

10 tonnes

LOCATION: RIGGING LOFT PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Broken dead end

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner: Pacific Drilling

We hereby certify that on 12/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7914

14/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment CHAIN HOIST

SWL

BTCP 5559-5

7mm X Manual Chain Hoist, double Fall

3 tonnes

LOCATION: RIGGING STORE RISER DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Bottom hook drive chain gear is faulty


(No t fit for Use) Name and address of equipment owner: Pacific Drilling

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 14/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7915

Date of Examination

Examiner

Qualifications

05/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment FALL ARRESTOR

SWL

01839

5mm X 15ft Fall Arrestor

310 lbs

LOCATION: BOSUN STORE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Faulty Gear

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 05/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 7916

Date of Examination

Examiner

Qualifications

24/07/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment
WEBBING SLING

SWL

BTCP 5567-12

1 pc

1mtr Flat Woven Webbing Sling

2 tonnes

LOCATION:SUBSEA WORKSHOP
Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Burst Stitches

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 24/07/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only

JC International Limited

RC. 413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7917

16/08/2012

OLATUNJI AKINLADE

LEEA, SNT LEVEL II MT, PT & UT

Identification Number

Qty

Description of Equipment
WEBBING SLING

SWL

9.7901E+10

1 pc

6.3mtrs Flat Woven Webbing Sling

3 tonnes

LOCATION:RIGGING LOFT RISER DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Burst Stitches

Remove from service


Address of premises where Test / Examination was held: Pacific Bora

(No t fit for Use) Name and address of equipment owner : Pacific Drilling

We hereby certify that on 16/08/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only