You are on page 1of 3

JC International Limited

RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

343 Identification Number Qty

24/01/12

ONOBREDEFE ENI Description of Equipment

SNT LEVEL II MT, PT & UT

SWL

WIRE ROPE SLING


GLN/1874/04 1set

13mm X 4mtrs X 4 legged sling c/w quad master sling with ferrule secured thimble eye at all ends

4.5t @ o 0-45

LOCATION: PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

One leg of the wire rope sling is bad (cut from the center to separate part)

Remove from service

(Not Fit for Use)


Name and address of equipment owner:
CAMERON PACIFIC SCIROCCO

Address of premises where Test / Examination was held:

We hereby certify that on 24/01/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: ONOBREDEFE ENI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

344 Identification Number Qty

24/01/12

ONOBREDEFE ENI Description of Equipment

SNT LEVEL II MT, PT & UT

SWL

WIRE ROPE SLING


2ADZG 1set

13mm X 1.03mtrs X 2 legged sling c/w quad master sling with ferrule secured thimble eye at all ends

2.8t @ o 0-45

LOCATION: PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Broken wires were found on one leg of the wire rope sling

Remove from service

(Not Fit for Use)


Name and address of equipment owner:
CAMERON PACIFIC SCIROCCO

Address of premises where Test / Examination was held:

We hereby certify that on 24/01/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: ONOBREDEFE ENI Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

345 Identification Number Qty

24/01/12

ONOBREDEFE ENI Description of Equipment

SNT LEVEL II MT, PT & UT

SWL

WIRE ROPE SLING


1ADZG 1set

13mm X 1.03mtrs X 2 legged sling c/w quad master sling with ferrule secured thimble eye at all ends

2.8t @ o 0-45

LOCATION: PIPE DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Mechanical damage on one of the ferrule

Remove from service

(Not Fit for Use)


Name and address of equipment owner:
CAMERON PACIFIC SCIROCCO

Address of premises where Test / Examination was held:

We hereby certify that on 24/01/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: ONOBREDEFE ENI Conducting: Examination only

You might also like