You are on page 1of 3

JC International Limited

RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

100243 Identification Number Qty

08/02/2013

ANTHONY OBINNA

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment BOW CRANE HOOK

080883

Bow Crane Hook SWL: 24.6tonnes

Date of next Examination: 07/08/2013

SPECIFICATION: ASTME 1444 MPI METHOD: Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: TRANSOCEAN SUPPORT SERVICES

Address of premises where Test / Examination was held:

BALTIC 1

We hereby certify that on 08/02/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: ANTHONY OBINNA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

100244 Identification Number Qty

08/02/2013

ANTHONY OBINNA

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment STARBOARD CRANE HOOK

STHB001

Starboard Crane Hook SWL: 18.75tonnes

Date of next Examination: 07/08/2013

SPECIFICATION: ASTME 1444 MPI METHOD: Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: TRANSOCEAN SUPPORT SERVICES

Address of premises where Test / Examination was held:

BALTIC 1

We hereby certify that on 08/02/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: ANTHONY OBINNA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

100245 Identification Number Qty

08/02/2013

ANTHONY OBINNA

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment PORTSIDE CRANE HOOK

PTHB002

Portside Crane Hook SWL: 24.6tonnes

Date of next Examination: 07/08/2013

SPECIFICATION: ASTME 1444 MPI METHOD: Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: TRANSOCEAN SUPPORT SERVICES

Address of premises where Test / Examination was held:

BALTIC 1

We hereby certify that on 08/02/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: ANTHONY OBINNA Conducting: Examination only

Revision No: 01