SITRAIN

ST-BWINCCS /Alarm Logging Page 1 Siemens AG 2007


Message Display and Message Archiving 1/2
SITRAIN
ST-BWINCCS /Alarm Logging Page 2 Siemens AG 2007
Binary tag
Prepare message
Ring buffer main memory
old/
new
Message
frame
Inter-
pre-
tation
Process
Message system API
Message sequence
report
- Shift reporting
- Daily reporting
- Monthly reporting
Selection in archive
New page
Internal tag
Limit values
Central WinCC
Archive Server
(CAS)
Integrated backup function
User
applications
e. g. diagnostics
- Connectivity Pack
- DataMonitor (Web-Client
for historian display and
analysis)
Options
Add-On ODK
Message list
Long-term Archive-
Server LAS
(Backup Server)
SICOMP IPC RI 20
SIEMENS
WinCC Alarm Control
Long-term archive FAQ
23730649
Message System 1/3

SITRAIN
ST-BWINCCS /Alarm Logging Page 3 Siemens AG 2007
RT Database (cyclic archive)
ALG Master
Database
RT Master database
Swap in/Swap out
Depends on the
requirements -> Backup
Archives (*.mdf,*.ldf)
Analysis / Evaluation
WinCC Standard Tool (Control)
Protocols (Report Designer)
Options
DataMonitor + Excel
Connectivity Pack + External Appl.
IndustrialDataBridge + Ext. Appl.
Data acquistion
WinCC Datenmanager
OPC Server
WinCC Server-Server
Communication
Long-term archiving
High performance archiving
Swap data in - swap data out
Note: ES=Single segment
Message System 2/3
SITRAIN
ST-BWINCCS /Alarm Logging Page 4 Siemens AG 2007
Datenerfassung
+WinCC Datenmanager
+OPC Server
+WinCC Server-Server
Communication (max.11)
Runtime-Data Alarm Logging Segment:
COMPUTER_PROJECT_ALG_<period_from>_<period_to>.LDF
COMPUTER_PROJECT_ALG_<period_from>_<period_to>.MDF
COMPUTER_PROJECT_ALG_YYYYMMDDHHMM.LDF
Example: HMI_Generator_ALG_200904300901.mdf
Long-term archive
Short-term archive
Message list
Message System 3/3

SITRAIN
ST-BWINCCS /Alarm Logging Page 5 Siemens AG 2007
Message line
System blocks
Time
Date
Number
User blocks
Cause of fault
Fault location
max. 10
Process value blocks
Process value 2
Prozess value 1
max. 10
Message Blocks and Message Line
SITRAIN
ST-BWINCCS /Alarm Logging Page 6 Siemens AG 2007
1. Double-click on the Alarm Logging icon or via
shortcut menu, click on the mouse to select Open.
Result: Alarm Logging starts.
2. Maximize the window and set up the interface
as you want it.
Message System Call-Up

SITRAIN
ST-BWINCCS /Alarm Logging Page 7 Siemens AG 2007
Editing window
Table window
Navigation window
Limit value monitoring
M > Tools, O >Expansions ...
Select Wizard
Message System Configuration Interface
SITRAIN
ST-BWINCCS /Alarm Logging Page 8 Siemens AG 2007
Export/Import Interface (*.CSV)
Create WinCC System Messages
M>File, O>Select Wizard
Wizard Overview
Engineering
dialogs
Wizards

SITRAIN
ST-BWINCCS /Alarm Logging Page 9 Siemens AG 2007
Context menu
Editing Message Blocks and Defining Properties
Context menu
SITRAIN
ST-BWINCCS /Alarm Logging Page 10 Siemens AG 2007
Structure of Messages with Message Classes and
Message Types
1) Technological classification
Message Classes
2) Priority classification
Message Classes
1... 16
1...
16
Types
1... 16
1...
Types
1... 16

SITRAIN
ST-BWINCCS /Alarm Logging Page 11 Siemens AG 2007
Integration of WinCC system
messages
Editing and Configuring Message Classes
- Status Texts
for messages
- Acknowledgement theory
- Acknowledgement of central
signaling devices
Max. 16 types
SITRAIN
ST-BWINCCS /Alarm Logging Page 12 Siemens AG 2007
Editing the Message Types

SITRAIN
ST-BWINCCS /Alarm Logging Page 13 Siemens AG 2007
Context menu
or
or
Revolving archive
Setting Up a Message Archive
SITRAIN
ST-BWINCCS /Alarm Logging Page 14 Siemens AG 2007
RT Data
Context menu
Backup Configuration

SITRAIN
ST-BWINCCS /Alarm Logging Page 15 Siemens AG 2007
WinCC in RT mode
Link:
Necessary when old archive files
are to be evaluated
Disconnect:
"Opposite" of Link
WinCC in CS mode
Reset:
All Database files in the
long-term archive are deleted
after check back.
In the first RT mode, DB files
are automatically recreated.
Context menu
Connect backup Disconnect backup
RT
Resetting the Archive and Evaluating Backup Files
SITRAIN
ST-BWINCCS /Alarm Logging Page 16 Siemens AG 2007
- Info text
- Text for
user blocks
- Tags for
process value
blocks
- Loop in Alarm
picture
Context menu
Properties
Message tag, open selection dialog
Reset entry
Editing a Single Message for Bit Message Procedure

SITRAIN
ST-BWINCCS /Alarm Logging Page 17 Siemens AG 2007
WinCC Alarm Control in Graphics Designer
SITRAIN
ST-BWINCCS /Alarm Logging Page 18 Siemens AG 2007
Can be reopened
by double click
Toolbar
-Edit message
line
- Edit message
blocks
...
- Toolbar on/off
- Key function
- Authorization
- Hotkeys, Tooltip
- Status line on/off
- Enable elements of
Status line
Message line
Preview
Status line
- Statistical
information

- Column header
- Sort
- Line titles
- Table contents
- Color attributes
of Alarm Control
- CSV file
- Range
- Select trigger event
for operator
input message
Window Properties for WinCC Alarm Control

SITRAIN
ST-BWINCCS /Alarm Logging Page 19 Siemens AG 2007
Double click
Preview
1. Select
2. Accept
1. Select
2.Message block
Move up or down
Message List for WinCC Alarm Control
SITRAIN
ST-BWINCCS /Alarm Logging Page 20 Siemens AG 2007
1) From message classes:
Message class A Message class B ..... ... Message class P
Message type 1 .... Message type 16 ...... ... ..... Message type 1 ... Message type 16
2) From user-defined messages:
Message number x to (x+2n) ........... Message number y to (y+2m)
Messages .... .... Messages Messages .... .... Messages
x to x+n .... .... x to x+2n y to y+m .... .... y to y+2m
Group Messages

SITRAIN
ST-BWINCCS /Alarm Logging Page 21 Siemens AG 2007
Creating the Tag for a Group Message
SITRAIN
ST-BWINCCS /Alarm Logging Page 22 Siemens AG 2007
in Alarm - Logging
Connect Status Tag with the Group Message (Message Class)

SITRAIN
ST-BWINCCS /Alarm Logging Page 23 Siemens AG 2007
00000001 00000001
00000000 00000001
00000001 00000000
00000000 00000000
Incoming not ackn.
Incoming ackn.
Outgoing not ackn.
Outgoing ackn.
(finished)
15... ..8
Bit 0: 0-there is no malfunction
1-there is a malfunction
Bit 8: 0-message is acknowledged
1-message is not acknowledged
Representation of the Status Tag for a Text Object