You are on page 1of 6

GE-1208 Open Channel Ultrasonic Flow Meter

User Manual

A.YITE

TECHNOLOGY GROUP

HTTP://WWW.AYITE.NET
tech@ayite.net

A.YITE TECHNOLOGY

http://www.ayite.net

1. Function:
This flowmeter need used with Parshall flume, the sensor will not contact with the liquid, so it
will be much more safety and stability

2. Principle

GE-1208 Meter measure the liquid level directly, the


Parshall flume transfer the flow rate to the liquid level.
This meter measure the liquid level, then calculte the
flow rate, show the result on the screen.
2.1 the flume measure the flow
If we use the Parshall flume to measure the flow, there
is relativity between the flow and the level, it mainly
depend on the physical dimension.
When we use the GE-1208 Flowmeter, we must know
the relation between the flow rate and the liquid level.
We could get this relation from the supplier of parshall
flume, or check the standard data from the attached
file.

2.2 The principle of meter


The flowmeter sent and receive the
ultrasonic, transfer it to liquid level.
there is the relative data in the meter,
it could measure the flow by the level.
It have 4-20mA, reply, RS232 output.

A.YITE TECHNOLOGY

http://www.ayite.net

3. Parameter Setup
Press MENU Button, then you will go to setup the parameter
Press MENU Button, it will turn page on the screen
Press 4 Button, it will move the Changeable digit position
Press Button, it will change the value of the changeable digit
Press RUN button, it will finish setup, start to work
1. Display screen

0700 mm Wale
000L/S Flow
00000000m3/h
Wale: the lquid level, measured by the sensor
Flow: It is the flow velocity
m3/h: it is cumulation for flow
Press MENU Button, setup the parameter

Parameter SET
20mA 0500.00
CleAcc 0 ADDE 001
Bad mold 0000mm
20mA 100L/s, means when 100L.s, the output is 20mA
ADDER 0000, it is RS485 address
Bad mold 0000, after install the sensor on the rack, connect with the meter, when there is no
water in parshall flume, at this time, the GE-1208 meter show the value of liquid level; input this
value as Bad Mold value by 4 Button and Button, then the value of liquid level
change to zero. then, when liquid flow into the flume, the GE-1208 will show the actual value of
liquid level.
Alarm setup 1
Press MENU Button, setup the parameter

Parameter SET
I-Corre 0000%
AON 0000 mm
AOFF 0000 mm
I-Corre 0000%
A
A

The adjustmant of the 4-20mA current output

ON 0000mm, Relay A, L<H switch ouput, L=0000mm


OFF 0000mm, Relay A, L<H switch ouput, H=0000mm

A.YITE TECHNOLOGY

http://www.ayite.net

Alarm setup 2
Press MENU Button, setup the parameter

Parameter SET
B: ON 0000 mm
BOFF
0000 mm
Slot Mod 0000
B ON 0000mm, Relay B, L<H switch ouput, L=0000mm
B OFF 0300mm, Relay B, L<H switch ouput, H=0300mm
Slot Mod, please check the attached data about parshall flume, if 0002, it relate to No.2 data
sheet, b=0.051, flow is 50m/h.
After finish setup the parameter, press 4andat the same time, it will save the setup
parameter.
4. Parshall flume
if the flow is more than 40L/s, we advise the parshall flume for you. Actually, in most condition,
the flow is more than 40L/s.

The above drawing is for parshall flume, there is standard method to produce the
parshall flume, so you just need check the value for

A.YITE TECHNOLOGY

http://www.ayite.net

Throat sizebcould be 0.0510.0760.1520.2280.3m, the parshall flume have


standard technology data for the relation between the liquid level and the flow.
0.051m Throat size:
Level
Flow
Level
Flow
Level
Flow
Level
Flow

0.000
0.0000
0.100
3.4018
0.200
9.9610
0.300
13.214

0.010
0.0959
0.110
3.9434
0.210
10.743
0.310
13.214

0.076 m Throat size:


Level
Flow
Level
Flow
Level
Flow
Level
Flow

0.000
0.0000
0.100
4.9914
0.200
14.616
0.300
27.400

0.010
0.1407
0.110
5.7860
0.210
15.764
0.310
28.829

Level: meter; Flow: L/s


0.020
0.2807
0.120
4.5127
0.220
11.547
0.320
13.214

0.030
0.5263
0.130
5.1089
0.230
12.370
0.330
13.214

Level: meter;
0.020
0.4119
0.120
6.6214
0.220
16.942
0.320
30.283

0.030
0.7722
0.130
7.4960
0.230
18.151
0.330
31.763

0.152 m Throat size: Level: meter;


Level
Flow
Level
Flow
Level
Flow

0.000
0.0000
0.200
32.488
0.400
93.821

0.020
0.9588
0.220
37.589
0.420
101.09

0.040
2.7689
0.240
42.941
0.440
108.55

0.060
5.1490
0.260
48.536
0.460
116.19

0.228 m Throat size: Level: meter;


Level
Flow
Level
Flow
Level
Flow
Level
Flow

0.000
0.0000
0.200
45.630
0.400
131.77
0.600
245.05

0.020
1.3466
0.220
52.794
0.420
141.99
0.620
257.64

0.040
3.8889
0.240
60.312
0.440
152.46
0.640
257.64

0.060
7.2319
0.260
68.169
0.460
163.19
0.660
257.64

0.300 m Throat size: Level: meter;


Level
Flow
Level
Flow
Level
Flow
Level
Flow

0.000
0.0000
0.200
58.713
0.400
168.50
0.600
312.20

0.020
1.7690
0.220
67.873
0.420
181.48
0.620
328.17

0.040
5.0760
0.240
77.477
0.440
194.79
0.640
344.41

0.060
9.4067
0.260
87.507
0.460
208.41
0.660
360.91

0.040
0.8221
0.140
5.7307
0.240
13.214
0.340
13.214

0.050
1.1617
0.150
6.3775
0.250
13.214
0.350
13.214

0.060
1.5411
0.160
7.0484
0.260
13.214
0.360
13.214

0.070
1.9571
0.170
7.7429
0.270
13.214
0.370
13.214

0.080
2.4071
0.180
8.4602
0.280
13.214
0.380
13.214

0.090
2.8892
0.190
9.1997
0.290
13.214
0.390
13.214

0.050
1.7046
0.150
9.3575
0.250
20.655
0.350
31.763

0.060
2.2613
0.160
10.342
0.260
21.950
0.360
31.763

0.070
2.8716
0.170
11.361
0.270
23.272
0.370
31.763

0.080
3.5319
0.180
12.413
0.280
24.621
0.380
31.763

0.090
4.2393
0.190
13.499
0.290
25.998
0.390
31.763

0.120
14.870
0.320
66.586
0.520
116.19

0.140
18.825
0.340
73.167
0.540
116.19

0.160
23.092
0.360
79.854
0.560
116.19

0.180
27.652
0.380
86.740
0.580
116.19

0.120
20.885
0.320
93.661
0.520
196.86
0.720
257.64

0.140
26.440
0.340
102.76
0.540
208.56
0.740
257.64

0.160
32.433
0.360
112.16
0.560
220.50
0.760
257.64

0.180
38.837
0.380
121.83
0.580
232.66
0.780
257.64

0.120
26.996
0.320
120.01
0.520
251.14
0.720
411.98

0.140
34.130
0.340
131.60
0.540
265.97
0.740
429.51

0.160
41.815
0.360
143.55
0.560
281.10
0.760
447.29

0.180
50.019
0.380
155.85
0.580
296.51
0.780
447.29

Flow: L/s
0.040
1.2062
0.140
8.4085
0.240
19.389
0.340
31.763

Flow: L/s
0.080
7.9961
0.280
54.363
0.480
116.19

0.100
11.250
0.300
60.416
0.500
116.19

Flow: L/s
0.080
11.231
0.280
76.354
0.480
174.17
0.680
257.64

0.100
15.801
0.300
84.854
0.500
185.40
0.700
257.64

Flow: L/s
0.080
14.570
0.280
97.948
0.480
222.35
0.680
377.67

0.100
20.458
0.300
108.79
0.500
236.59
0.700
394.70

If the user have special need about the parshall flume, we could supply drawing
picture, direct to build the flume

A.YITE TECHNOLOGY

http://www.ayite.net

Wire Diagram

Output with other meter


1. Connect with PC
Power

Meter

DC 12V or 24V

DC +
Out A
Out B
DC -

485232

A
B

PC
SERIAL
PORT

2relay output
Vcc
R1
J1
Vcc
D1

C
MHz
E
GND

GND

You might also like