You are on page 1of 10

Post Summer Summary

P.Butti
Nikhef, FOM

October 22, 2013

P.Butti (Nikhef, FOM)

October 22, 2013

1 / 10

Summary

ID Alignment
Closure on Z Alignment validation 2012 ID Alignment performance public note Multiple scattering studies on residual width 2012 ID Alignment performance public note Talk on ID Workshop Innsbruck () 28Oct - 1 Nov Insertable B-Layer Studies
Link

P.Butti (Nikhef, FOM)

October 22, 2013

2 / 10

Expected eect of MCS

In a detector particles undergo Multiple Coulomb Scattering This eect aect more the low pT particles eect on track parameters i.e. (from TDR) pT 1.30% = 0.036% pT pT sin Courtesy of Vicente L. Miquel - IFIC Eorts made to include the MCS in alignment algorithm 2 mi ( ) hi ( ) 2 scat 2 = + i 2 scat
hits

Where: = 13.6MeV Z cp x X0 1 + 0.038 ln x X0

P.Butti (Nikhef, FOM)

October 22, 2013

3 / 10

Eect on Residuals - Silicon


Eect on Silicon Detectors - pT > 10 GeV tracks Degradation of the Residual width with decreasing pT Expected Behaviour For high pT tracks approaching to the intrinsic resolution of the modules

P.Butti (Nikhef, FOM)

October 22, 2013

4 / 10

Eect on Residual - Silicon

MCS has a considerable impact on the RMS of residual distributions As expected no displacement is observed in the mean of the distributions

P.Butti (Nikhef, FOM)

October 22, 2013

5 / 10

Talk to Innsbruck Workshop

Monitoring problems - What we should see. What to improve for next run. DQMonitoring Performance monitoring - Does it worth? Present plots to shifters in a more compact way. Avoid duplications of information Shifter Page Include IBL monitoring plots useful for b-tagging performance

P.Butti (Nikhef, FOM)

October 22, 2013

6 / 10

IBL Z TrackSelection

Track pT > 10GeV d 0 < 500 mm |z0 sin()| < 500 mm nHitPix 1 nHitPixPhysical 1 nHitBLayer 0 nHitTRT 0 nHitSi 9

nHitPixBLayerPlusPix 0

nHitSiPhysical 7 nHitTRT 0

P.Butti (Nikhef, FOM)

October 22, 2013

7 / 10

PIX X Residuals - Comparison with other modules

P.Butti (Nikhef, FOM)

October 22, 2013

8 / 10

PIX X Pulls - Comparison with other modules

P.Butti (Nikhef, FOM)

October 22, 2013

9 / 10

Issues

The ModEta = 0 is lled even if in the PixMgr the module is properly skipped. Need to investigate the histo lling for PIX in detail. ModEta =8 is empty. Same study has to be performed on Cosmic samples but we encountered problems during the reconstruction step after the digitization of the reconstructed samples. In contact with the experts.

Expected symmetric around 0

P.Butti (Nikhef, FOM)

October 22, 2013

10 / 10

You might also like