Submitter: Company:
Laboratory Number
Submitter Label
Material
Method of Analysis
Biobased Result
Beta-322253
SAMPLE #1
Biobased Liquid
Method-B
76 %
sample container
* ASTM-D6866 cites precision on The Mean Biobased Result as +/- 3% (absolute). This is the most conservative estimate of error in the measurement of complex biobased containing solids and liquids based on empirical results. Real precision for readily combustible and homogenous materials (e.g. gasoline) and especially samples recieved as CO2 (e.g. flue gas or CEMS exhaust) can be as low as +/- 0.5-2%. The result only applies to the analyzed material. Fluctuations in carbon content within a batch of product, gasoline or flue gas must be determined separately (e.g. averaged measurements of multiple solids or liquids, and single measurement of the combination of gas aliquots collected over time). The accuracy of the result as it applies to the analyzed product, fuel, or flue gas relies upon all the carbon in the analyzed material originating from either recently respired atmospheric carbon dioxide (within the last decade) or fossil carbon (more than 50,000 years old). "Percent biobased" specifically relates % renewable (or fossil) carbon to total carbon, not to total mass or molecular weight. Mean Biobased estimates greater than 100% are assigned a value of 100% for simplification.
Page 1 of 4
Submitter label
Material
Laboratory Number
SAMPLE #1
Biobased Liquid
Beta-322253
x 0.95
* ASTM-D6866 cites precision on The Mean Biobased Result as +/- 3% (absolute). This is the most conservative estimate of error in the measurement of complex biobased containing solids and liquids based on empirical results. Real precision for readily combustible and homogenous materials (e.g. gasoline) and especially samples recieved as CO2 (e.g. flue gas or CEMS exhaust) can be as low as +/- 0.5-2%. The result only applies to the analyzed material. Fluctuations in carbon content within a batch of product, gasoline or flue gas must be determined separately (e.g. averaged measurements of multiple solids or liquids, and single measurement of the combination of gas aliquots collected over time). The accuracy of the result as it applies to the analyzed product, fuel, or flue gas relies upon all the carbon in the analyzed material originating from either recently respired atmospheric carbon dioxide (within the last decade) or fossil carbon (more than 50,000 years old). "Percent biobased" specifically relates % renewable (or fossil) carbon to total carbon, not to total mass or molecular weight. Mean Biobased estimates greater than 100% are assigned a value of 100% for simplification.
Page 2 of 4
SAMPLE #1 Beta-322253 Biobased Liquid May 18, 2012 May 22, 2012
BioBased 76%
* ASTM-D6866 cites precision on The Mean Biobased Result as +/- 3% (absolute). This is the most conservative estimate of error in the measurement of complex biobased containing solids and liquids based on empirical results. Real precision for readily combustible and homogenous materials (e.g. gasoline) and especially samples recieved as CO2 (e.g. flue gas or CEMS exhaust) can be as low as +/- 0.5-2%. The result only applies to the analyzed material. Fluctuations in carbon content within a batch of product, gasoline or flue gas must be determined separately (e.g. averaged measurements of multiple solids or liquids, and single measurement of the combination of gas aliquots collected over time). The accuracy of the result as it applies to the analyzed product, fuel, or flue gas relies upon all the carbon in the analyzed material originating from either recently respired atmospheric carbon dioxide (within the last decade) or fossil carbon (more than 50,000 years old). "Percent biobased" specifically relates % renewable (or fossil) carbon to total carbon, not to total mass or molecular weight. Mean Biobased estimates greater than 100% are assigned a value of 100% for simplification.
Page 3 of 4
Explanation of Results
Biobased Analysis using ASTM-D6866-11, April 2011
The application of ASTM-D6866 to derive a "Biobased content" is built on the same concepts as radiocarbon dating, but without use of the age equations. It is done by deriving a ratio of the amount of radiocarbon (14C) in an unknown sample to that of a modern reference standard. This ratio is calculated as a percentage with the units "pMC" (percent modern carbon). If the material being analyzed is a mixture of present day radiocarbon and fossil carbon (containing no radiocarbon), then the pMC value obtained correlates directly to the amount of biomass derived carbon in the sample. The modern reference standard used in radiocarbon dating is a NIST (National Institute of Standards and Technology) standard with a known radiocarbon content equivalent approximately to the year AD 1950. AD 1950 was chosen since it represented a time prior to thermo-nuclear weapons testing which introduced large amounts of excess radiocarbon into the atmosphere with each explosion (termed "bomb carbon"). This was a logical point in time to use as a reference for archaeologists and geologists. For an archaeologist or geologist using radiocarbon dates, AD 1950 equals "zero years old". It also represents 100 pMC. "Bomb carbon" in the atmosphere reached almost twice normal levels in 1963 at the peak of testing and prior to the treaty halting the testing. Its distribution within the atmosphere has been approximated since its appearance, showing values that are greater than 100 pMC for plants and animals living since AD 1950. It has gradually decreased over time with today 's value being near 105 pMC. This means that a fresh biomass material such as corn, sugar cane or soybeans would give a radiocarbon signature near 105 pMC. Combining fossil carbon with present day carbon into a presuming ~105 pMC represents present day biomass pMC value for that material will reflect the proportions from present day soybeans would give a radiocarbon carbon, it would give a radiocarbon signature near 53 pMC. material will result in a dilution of the present day pMC content. By materials and 0 pMC represents petroleum derivatives, the measured of the two component types. For example, a material derived 100% signature near 105 pMC. But if it was diluted with 50% petroleum
The "biobased content" of a material is reported as a percent value relating total renewable organic carbon to total organic carbon. The final result is calculated by multiplying the pMC value measured for the material by 0.95 (to adjust for bomb carbon effect). The final value is cited as the MEAN BIOBASED RESULT and assumes all the components within the analyzed material were either present day living (within the last decade) or fossil in origin. The results provided in this report are uniquely applicable to the analyzed material and are reported using the designated labeling provided with the sample. Although analytical precision is typically 0.1 to 0.5 pMC, empirical data has demonstrated that indeterminant errors can introduce uncertainty to 2 to 3 pMC. As such, ASTM-D6866 cites an uncertainty of +/- 3 % (absolute) on each result. Remember the results only relate carbon source, not mass source. A reported percentage does not represent to the total mass of fossil vs. renewable components present. Only the amount of renewable carbon vs fossil carbon present is indicated.