You are on page 1of 5

ai r duct systems | silencers

Circular straight silencer

SLU 50

Dimensions

1
l

dy
d1

Description
Insulation thickness 50 mm.
For general information about the silencers design, please
refer to page 132.

Ordering example
SLU

125

600

50

Product
Dimension d1
Length l
Insulation thickness

Technical data
en

d1

10

[m

m]

0
20

ity
loc
Ve

Specific pressure drop p t

sio

16

10

[m
/

s]

50

12

10

80

15

100

25
0

Dim

[Pa/m]

1
0.5

0.1
10

50

100

500

1 000

100

500

1 000
Flow q

l
mm
300
600
900
1200
300
600
900
1200
300
600
900
1200
300
600
900
1200
300
600
900
1200
600
900
1200
600
900
1200
600
900
1200

Attenuation in dB for centre frequency


Hz
63 125 250 500 1k
2k
4k
8k
2
4
8
16
27
34
35
19
3
9
16
28
46
53
46
25
4
5
20
36
56
57
58
41
5
6
23
40
62
61
62
45
3
4
8
14
23
27
25
14
3
8
13
25
40
50
40
21
3
5
18
33
53
55
48
28
3
6
22
39
60
61
53
33
3
2
7
14
21
26
20
12
2
7
12
23
39
47
32
18
0
3
16
29
53
52
39
24
0
3
18
37
60
59
52
28
3
2
5
12
17
24
17
11
3
4
8
21
37
40
22
14
0
4
12
27
46
51
29
20
0
3
14
34
51
53
33
18
3
1
4
10
16
20
14
11
2
4
8
20
31
32
20
15
0
4
10
25
32
40
24
18
0
4
13
32
51
48
28
17
1
2
6
15
27
25
15
14
0
2
8
22
37
34
18
16
0
2
10
27
42
39
20
18
3
3
7
12
17
14
11
10
1
3
9
17
25
20
14
13
2
3
12
24
37
23
17
15
2
2
4
6
8
5
5
6
2
3
5
10
12
8
6
8
3
3
7
13
16
10
7
9

dy
mm
190
190
190
190
210
210
210
210
235
235
235
235
270
270
270
270
310
310
310
310
365
365
365
465
465
465
508
508
508

m
kg
2,21
3,73
5,49
6,90
2,64
4,80
6,25
7,89
3,05
5,18
7,38
9,05
3,45
6,30
8,88
11,1
4,43
7,54
10,7
13,3
9,30
12,8
16,5
12,7
17,7
23,0
20,0
26,0
29,0

5 000 10 000 [l/s]


[m3/h]

50

d1
nom
80
80
80
80
100
100
100
100
125
125
125
125
160
160
160
160
200
200
200
200
250
250
250
315
315
315
400*
400*
400*

* Supplied with two loose couplings

5 000 10 000

10

11

We reserve the right to make changes without prior notice

133

ai r duct systems | silencers

Circular straight silencer

SLU 100

Dimensions

1
l

dy
d1

Description
Insulation thickness 100 mm.
Good attenuation in 125 and 250 Hz bands.
For general information about the silencers design, please
refer to page 132.

Ordering example
SLU

200

600

100

Product
Dimension d1
Length l
Insulation thickness

Technical data
n

d1

m]

80

0
63

44

40

25

20

55

50

10

[m

16
0

ity
loc
Ve

Specific pressure drop p t

sio

10

[m
/

s]

50

12

15

80

en

100

31
5

Dim

[Pa/m]

10

1
0.5

9
0.1
10

50

100

500

1 000

5 000 10 000 [l/s]


[m3/h]

50

100

500

1 000
Flow q

10

5 000 10 000

d1
nom
80
80
80
80
100
100
100
100
125
125
125
125
160
160
160
160
200
200
200
200
250
250
250
315
315
315
400*
400*
400*
500*
500*
630*
630*
800*
800*

l
mm
300
600
900
1200
300
600
900
1200
300
600
900
1200
300
600
900
1200
300
600
900
1200
600
900
1200
600
900
1200
600
900
1200
900
1200
900
1200
1200
1500

Attenuation in dB for centre frequency


Hz
63 125 250 500 1k
2k
4k
8k
1
6
15
21
26
33
31
17
7
13
26
32
50
50
45
25
8
14
29
38
58
57
55
39
8
17
33
40
60
59
59
45
4
6
13
18
26
29
22
13
6
10
19
28
38
47
33
18
8
14
26
37
54
52
45
25
7
15
30
38
58
55
50
30
3
6
10
14
20
27
20
12
6
10
19
28
39
42
28
17
3
11
26
36
52
47
41
24
6
10
29
37
54
53
47
27
4
4
8
13
17
23
15
10
5
8
15
23
31
40
22
16
3
9
21
32
47
52
29
19
4
10
29
34
49
53
30
18
3
3
6
9
14
19
13
10
2
6
15
18
27
29
19
15
2
7
21
26
40
39
24
18
3
9
27
34
48
45
27
17
1
5
13
16
23
25
15
13
1
5
18
25
35
31
17
16
3
7
21
29
41
39
20
18
2
4
8
11
16
15
11
11
3
5
12
15
24
21
14
13
3
7
16
21
32
26
17
15
1
3
6
9
13
13
9
8
1
4
10
14
21
18
12
11
2
7
13
19
27
24
15
13
2
5
8
12
15
14
12
10
3
6
12
18
21
17
14
12
1
5
8
11
11
12
9
7
3
5
11
16
15
15
11
9
3
5
8
11
10
11
9
6
3
5
10
14
13
13
11
8

* Supplied with two loose couplings

11

134

We reserve the right to make changes without prior notice

m
dy
mm
kg
295
4,70
295
7,90
295 10,2
295 13,3
310
5,00
310
8,20
310 12,6
310 15,3
325
5,70
325
8,60
325 13,4
325 16,7
365
6,30
365 10,7
365 14,9
365 19,8
410
8,40
410 13,0
410 17,4
410 22,2
465 15,4
465 20,5
465 26,2
510 16,7
510 22,8
510 29,8
615 23,0
615 33,6
615 42,9
735 38,9
735 50,4
880 49,4
880 61,4
1030 84,8
1030 104

ai r duct systems | silencers

Circular straight silencer

SLGU 100

Dimensions

dy
d1

Description
Insulation thickness 100 mm.
Thanks to the lower insulation density, this silencer is about
20% lighter than the corresponding SLU 100.
For the general information about the silencers design, please refer to page 132.

Ordering example
SLGU 250

900

100

Product
Dimension d1
Length l
Insulation thickness

Technical data
n

[m

m]

0
63

80

50

44

31
5

25

55

10

40

20

12

d1

Ve
loc
ity

Specific pressure drop p t

sio

16
0

10

[m
/

s]

50

10
0

15

80

en

100

Dim

[Pa/m]

1
0.5

0.1
10

50

100

500

1 000

5 000 10 000 [l/s]


[m3/h]

50

100

500

1 000
Flow q

5 000 10 000

d1
nom
80
80
80
80
100
100
100
100
125
125
125
125
125
160
160
160
160
160
200
200
200
200
250
250
250
250
315
315
315
315
400*
400*
400*
400*
500*
500*
500*
500*
630*
630*
630*
630*
800*
800*
800*

l
mm
300
600
900
1000
300
600
900
1000
300
600
900
1000
1200
300
600
900
1000
1200
600
900
1000
1200
600
900
1000
1200
600
900
1000
1200
900
1000
1200
1500
900
1000
1200
1500
900
1000
1200
1500
1000
1200
1500

Attenuation in dB for centre frequency


Hz
63 125 250 500 1k
2k
4k
8k
5
8
13
19
27
33
29
19
10
17
26
29
53
53
45
26
8
25
23
32
55
56
46
27
12
24
27
33
55
58
47
27
3
6
12
18
23
28
23
14
9
13
23
34
46
52
40
22
7
17
30
39
54
55
46
27
6
19
36
39
56
51
46
28
4
6
10
15
19
23
18
14
5
11
20
30
40
45
30
20
5
15
27
38
56
62
39
24
5
16
31
35
48
51
40
24
8
15
34
38
56
59
45
27
3
4
8
12
16
21
14
10
2
9
16
28
33
37
21
16
2
11
24
35
49
51
27
18
2
12
25
38
54
54
29
20
4
12
29
41
56
57
33
21
2
6
12
22
28
28
18
17
0
8
18
28
40
37
23
14
0
9
21
29
44
38
25
20
5
10
25
33
50
42
27
23
1
5
12
20
24
23
14
16
0
6
17
30
34
28
17
19
0
7
18
31
36
30
18
20
4
9
22
35
39
33
20
21
0
4
8
14
17
14
12
11
0
4
12
21
26
19
15
15
0
5
13
23
29
20
16
15
4
7
15
28
35
24
18
17
0
5
12
19
22
18
13
13
2
5
13
22
24
20
14
15
4
7
16
22
29
22
15
16
6
9
20
32
35
24
17
18
2
4
11
18
16
14
11
11
2
5
12
19
18
15
12
12
3
6
13
21
21
17
14
13
5
7
19
27
26
19
15
15
2
5
9
14
12
13
9
8
3
5
10
15
13
14
10
9
4
6
13
18
15
15
12
10
4
7
15
23
18
17
13
12
2
4
8
11
9
9
8
7
3
5
9
13
11
11
9
7
3
6
12
17
14
14
11
9

* Supplied with two loose couplings

We reserve the right to make changes without prior notice

dy
mm
295
295
295
295
310
310
310
310
325
325
325
325
325
365
365
365
365
365
410
410
410
410
465
465
465
465
510
510
510
510
615
615
615
615
735
735
735
735
880
880
880
880
1030
1030
1030

m
kg
3,00
5,30
7,60
8,40
3,40
6,10
8,80
9,70
3,20
5,90
8,50
9,40
11,2
4,20
7,50
10,7
11,8
14,0
10,6
15,3
16,9
20,0
12,2
17,7
19,5
23,2
14,1
20,5
22,6
26,8
27,4
30,2
35,9
44,3
31,4
34,6
41,0
50,6
39,9
43,9
51,9
64,0
58,0
68,7
84,7

10

11

135

ai r duct systems | silencers

Circular straight silencer

SLGU 150

Dimensions

1
l

dy
d1

Description
Insulation thickness 150 mm.
Used when you need particularly good attenuation at low frequencies (125 and 250 Hz). Otherwise equivalent to
SLGU 100.

For general information about the silencers design, please


refer to page 132.

Ordering example
SLGU 160

Technical data
Dim

[Pa/m]

en

d1

20
0

ity
loc
Ve

Specific pressure drop p t

10

150

Attenuation in dB for centre frequency


Hz
63 125 250 500 1k
2k
4k
8k
11
26
22
27
50
55
47
27
6
25
36
42
59
53
47
28
10
22
34
38
51
50
40
25
11
21
36
40
62
55
46
27
6
16
28
40
51
52
28
20
7
17
33
44
58
56
32
21
4
14
24
32
45
36
24
21
7
15
25
36
49
42
26
22
4
12
22
31
37
31
18
20
7
15
26
36
41
34
20
21

sio

16

10

[m

/s]

50

12

10

80

15

100

1000

l
mm
1000
1000
1000
1200
1000
1200
1000
1200
1000
1200

[m

m]

25
0

Product
Dimension d1
Length l
Insulation thickness

d1
nom
80
100
125
125
160
160
200
200
250
250

1
0.5

0.1
10

50

100

500

1 000

5 000 10 000 [l/s]


[m3/h]

50

10

100

500

1 000
Flow q

5 000 10 000

11

136

We reserve the right to make changes without prior notice

dy
mm
410
410
465
465
465
465
510
510
580
580

m
kg
15,1
15,7
17,7
20,9
18,6
22,1
21,9
25,9
25,1
29,8

ai r duct systems | silencers

Circular straight silencer

SLBU 100

Dimensions

1
l

dy
d1

Description
Insulation thickness 100 mm.
Provided with a 100 mm thick baffle. This gives very good attenuation across the entire range.
Used where very good attenuation is needed and SLU 100 is
not enough. Specially suitable for large dimensions.
For general information about the silencers design, please
refer to page 132.

Ordering example
100

l
mm
600
900
1200
600
900
1200
900
1200
900
1200
1500
1200
1500

Attenuation in dB for centre frequency


Hz
63 125 250 500 1k 2k 4k
8k
4
6 10 16 22 28 27
18
5
7 16 23 30 38 32
22
7
9 23 30 38 47 37
25
4
5
7
9 13 16 15
13
5
7 12 16 22 26 20
16
6 10 18 23 31 36 25
19
4
6
9 12 17 20 15
13
4
8 13 18 24 28 17
16
3
6
6
9 13 13 11
10
3
8 10 13 18 18 12
12
4 10 13 17 23 22 13
13
2
4
8 10 13 12
9
8
2
5 11 12 17 15 10
10

dy
m
mm
kg
510 18,7
510 25,6
510 33,3
625 24,9
625 36,3
625 46,5
735 42,1
735 54,5
880 53,1
880 66,2
880 79,0
1030 90,4
1030 111

* Supplied with two loose couplings

Technical data

[Pa]

Dimension d1 [mm]

500

00
12 900 0
60
0

00
15 0
0 120
0
8

63

50

0
1
1 50
90 200 0
0

0
40

100

12
90 00
0

00 0
12 90 00
6
15

50

Product
Dimension d1
Length l
Insulation thickness

900

Pressure drop pt

SLBU 400

d1
nom
315
315
315
400*
400*
400*
500*
500*
630*
630*
630*
800*
800*

10

1
0,5
100

500
500

1000

5000

1000
5000

10000

10000 [l/s]
30000 [m3/h]

10

Flow q

11

We reserve the right to make changes without prior notice

137

You might also like