Innerduct Seal-Off

You might also like

You are on page 1of 2

5 Blue Heron Drive

Comstar Supply, INC Collegeville, PA 19426


Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com

Limited Warranty USER GUIDE USER GUIDE USER GUIDE


Condux International, Inc. extends the following warranty to the original pur-
chaser of these goods for use, subject to the qualifications indicated:

Condux International, Incorporated warrants to the original purchaser for use


Innerduct Seal-Off
that the goods or any component thereof manufactured by Condux
International will be free from defects in workmanship for a period of one year
from the date of purchase, provided such goods are installed, maintained, and
used in accordance with Condux’s written instructions.

Components not manufactured by Condux International but used within the


assembly provided by Condux International are subject to the warranty period
as specified by the individual manufacturer of said component, provided such
goods are installed, maintained, and used in accordance with Condux’s and
the original manufacturer’s written instructions.

Condux’s sole liability and the purchaser’s sole remedy for a failure of goods
under this limited warranty, and for any and all claims arising out of the pur-
chase and use of the goods, shall be limited to the repair or replacement of
the goods that do not conform to this warranty.

To obtain repair or replacement service under the limited warranty, the pur-
chaser must contact the factory for a Return Material Authorization (RMA).
Once obtained, send the RMA along with the defective part or goods, trans-
portation prepaid, to:

Condux International, Inc.


145 Kingswood Road
Mankato, MN 56001

THERE ARE NO EXPRESS WARRANTIES COVERING THESE GOODS


OTHER THAN AS SET FORTH ABOVE. THE IMPLIED WARRANTIES OR
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
LIMITED IN DURATION TO ONE YEAR FROM DATE OF PURCHASE.

CONDUX ASSUMES NO LIABILITY IN CONNECTION


WITH THE INSTALLATION OR USE OF THIS PROD-
UCT, EXCEPT AS STATED IN THIS LIMITED WAR-
RANTY. CONDUX WILL IN NO EVENT BE LIABLE
FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.

CONDUX
Condux International, Inc. • P.O. Box 247 • 145 Kingswood Road • Mankato, MN 56001
507-387-6576 • 800-533-2077 • FAX 507-387-1442
Internet: http://www.condux.com © Copyright 1996, Condux International, Inc. ®
Printed in USA
Literature Part Number: 08034314
Revision Number: 1.2 CONDUX
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com
5 Blue Heron Drive
Comstar Supply, INC Collegeville, PA 19426
Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com

Operating Procedure Set-Up Procedure


NOTE: The seal-off body comes standard with a rope adapter for 1⁄4” diameter rope. 1. Based upon the duct’s inner diameter, determine the correct seal-off head size (Table 1).
Additional adapters are available for 3⁄16”-1⁄2” diameter ropes. Consult your Condux cata-
log, or see your Condux representative for more information. Part Duct Size Duct ID Range
Number Description (in) (mm) (in) (mm)
1. Insert the rope or line through the rope adapter and seal-off head. Tie the rope or 08034300 Complete Kit
line to the projectile or missile.
08034301 Seal-Off Body
2. Place the projectile or missile into the duct. Insert the seal-off head into the duct. 08034310 Seal-Off Body 1 25 .93-1.19 24-30

3. Twist the seal-off head and body clockwise until the head seats tightly inside the 08034311 Seal-Off Body 1 1/4 32 1.18-1.44 30-37
duct. Position the hose coupling for easy access. 08034312 Seal-Off Body 1 1/2 38 1.31-1.69 33-43
08034313 Seal-Off Body 2 51 1.93-2.31 49-59
4. Close the air flow valve by turning it until it is perpendicular to the coupling.
Table 1: Compatibility Chart
5. Attach the compressed air line to the seal-off’s air hose coupling. Ensure the air
pressure is not over 15 psi.
2. Screw the seal-off head onto the seal-off body and tighten until snug (Figure 1).
6. Slowly open the seal-off’s air flow valve until the rope or line begins to feed through
the duct. This valve also regulates the projectile or missile’s speed.
Rope Adapter Seal-Off Head

Removal Procedure
1. Close the air flow valve on the seal-off, and disconnect the compressed air line. Air Flow Innerduct
Valve
2. Loosen the seal-off by twisting it counterclockwise, and pull it out of the duct. Seal-Off Body

Air Hose Coupling

Figure 1: Condux Innerduct Seal-Off

!WARNING: Read and understand all procedure !CAUTION: Beware of sharp threads on the seal-off
and safety instructions before using any Condux head - wear leather work gloves when handling or
Innerduct Seal-Off. Failure to do so may result in personal injury could result.
personal injury or property damage. Save this
user’s guide for future reference.
ADVERTENCIA !ADVERTENCIA: Favor de leer y comprender todas !WARNING: Do not exceed 15 psi of air pressure.
las instrucciones de operación y seguridad antes Do not stand directly behind the Seal-Off. Serious
de usar el Condux Innerduct Seal-Off. Si Ud. no personal injury could result.
Instrucciones
de Operación comprende las instrucciones favor de consultarle a
su jefe.

!CAUTION: Wear personal protective equipment: !WARNING: Keep the compressed air hose
hard hat, safety glasses, safety shoes, and leather couplings clean of debris. Compressed air blows
work gloves. surrounding debris during the installation and
removal of the air line. Serious personal injury
could result.