Condux’s sole liability and the purchaser’s sole remedy for a failure of goods
under this limited warranty, and for any and all claims arising out of the pur-
chase and use of the goods, shall be limited to the repair or replacement of
the goods that do not conform to this warranty.
To obtain repair or replacement service under the limited warranty, the pur-
chaser must contact the factory for a Return Material Authorization (RMA).
Once obtained, send the RMA along with the defective part or goods, trans-
portation prepaid, to:
CONDUX
Condux International, Inc. • P.O. Box 247 • 145 Kingswood Road • Mankato, MN 56001
507-387-6576 • 800-533-2077 • FAX 507-387-1442
Internet: http://www.condux.com © Copyright 1996, Condux International, Inc. ®
Printed in USA
Literature Part Number: 08034314
Revision Number: 1.2 CONDUX
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com
5 Blue Heron Drive
Comstar Supply, INC Collegeville, PA 19426
Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com
3. Twist the seal-off head and body clockwise until the head seats tightly inside the 08034311 Seal-Off Body 1 1/4 32 1.18-1.44 30-37
duct. Position the hose coupling for easy access. 08034312 Seal-Off Body 1 1/2 38 1.31-1.69 33-43
08034313 Seal-Off Body 2 51 1.93-2.31 49-59
4. Close the air flow valve by turning it until it is perpendicular to the coupling.
Table 1: Compatibility Chart
5. Attach the compressed air line to the seal-off’s air hose coupling. Ensure the air
pressure is not over 15 psi.
2. Screw the seal-off head onto the seal-off body and tighten until snug (Figure 1).
6. Slowly open the seal-off’s air flow valve until the rope or line begins to feed through
the duct. This valve also regulates the projectile or missile’s speed.
Rope Adapter Seal-Off Head
Removal Procedure
1. Close the air flow valve on the seal-off, and disconnect the compressed air line. Air Flow Innerduct
Valve
2. Loosen the seal-off by twisting it counterclockwise, and pull it out of the duct. Seal-Off Body
!WARNING: Read and understand all procedure !CAUTION: Beware of sharp threads on the seal-off
and safety instructions before using any Condux head - wear leather work gloves when handling or
Innerduct Seal-Off. Failure to do so may result in personal injury could result.
personal injury or property damage. Save this
user’s guide for future reference.
ADVERTENCIA !ADVERTENCIA: Favor de leer y comprender todas !WARNING: Do not exceed 15 psi of air pressure.
las instrucciones de operación y seguridad antes Do not stand directly behind the Seal-Off. Serious
de usar el Condux Innerduct Seal-Off. Si Ud. no personal injury could result.
Instrucciones
de Operación comprende las instrucciones favor de consultarle a
su jefe.
!CAUTION: Wear personal protective equipment: !WARNING: Keep the compressed air hose
hard hat, safety glasses, safety shoes, and leather couplings clean of debris. Compressed air blows
work gloves. surrounding debris during the installation and
removal of the air line. Serious personal injury
could result.