VFD-V Series

Specifications
230V Class
Model Number VFD-xxxV23A 150 185 220 300 370 Max. Applicable Motor 0.7 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 output (kW) Max. Applicable Motor 1 2 3 5 7.5 10 15 20 25 30 40 50 output (HP) Constant Torque Output 7.5 11 17 25 33 49 65 75 90 120 146 5.0 Current (A) Variable Torque Output 6.25 9.4 13 21 31 41 61 81 93 112 150 182 Current (A) Rated Output Capacity kVA 1.9 2.7 4.2 6.5 9.5 12.5 19 25 29 34 46 55.6 Maximum Output Voltage 3-phase 200~230V proportional to the input voltage (V) Rated Input 200/208/220/230 VAC 3-phase, 50/60Hz Voltage/Frequency Operation Voltage 180~265VAC, 47~63Hz Range/Frequency Input Current 6.4 10 14.9 21.2 25.2 33.2 50 69 89 99 120 146 161 189 271 Control System 1. Vector Control; 2. Torque Control; 3. V/F Control Starting Torque Starting Torque is 150% at 0.5Hz and above. Speed Control Range 1:100 Sensorless Vector (1:1000 when using PG card and encoder feedback) Speed Control Accuracy 0.5% Sensorless Vector (0.02% when using a PG card and encoder feedback) Speed Response Ability 5Hz (connect externally with PG to achieve 30Hz) Maximum Output 0.00 to 400.00 Hz Frequency (Hz) Frequency Output Digital Command: 0.005%, Analog Command: 0.5% Accuracy Frequency-Set Resolution Digital Command: 0.01Hz, Analog Command: 1/1000 (10bit) of the maximum output frequency Torque Limit Maximum allowable torque is 200% Torque Accuracy 5% Accel/Decel Time 0.00~600.00/0.1~6000.0 sec V/F Curve Adjustable V/F curve using 4 independent points. Frequency Control Signal 0-10V, -10-+10V, 4-20mA, Square wave pulse input Braking Torque Approx. 20% Motor Protection Electronic thermal relay protection Over-Current Protection The current forces 220% of the over-current protection and 300% of the rated current Current Leakage Protection: 50% peak value rated current Ground Current Leakage Protection Over-Load Ability Constant/Variable torque 150% for 60 seconds; 200% for 2 seconds Over-voltage level: Vdc>400/800 V; low-voltage level: Vdc<200/400 V Voltage Protection 220V/440V Over-Voltage Protection for Varistor (MOV) the Input Power Over-Temperature Built-in temperature sensor Protection Momentary Power Loss 5 second maximum time setting Protection Level NEMA 1/IP21 Ambient Temperature -10 ~40 for UL & -10 ~50 for CE Storage Temperature -20 ~60 Humidity Below 90% RH (non-condensing) Vibration Below 20hz: 1G, above 20hz: 0.6G Cooling System Forced air cooling Installation Location Altitude of 1,000m or less, keep away from corrosive gas, liquid, and dust. 007 015 022 037 055 230V Class 075 110

Control Characteristics

Input Rating

Output Rating

Environment

Protection Characteristics

DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED

A-1

VFD-V Series

460V Class
Model Number VFD-xxxV43x Max. Applicable Motor output (kW) Max. Applicable Motor output (HP) Constant Torque Output Current (A) Variable Torque Output Current (A) Rated Output Capacity kVA Maximum Output Voltage (V) Rated Input Voltage/Frequency Operation Voltage Range/Frequency Input Current Control System Starting Torque Speed Control Range Speed Control Accuracy Speed Response Ability Maximum Output Frequency (Hz) Frequency Output Accuracy Frequency-Set Resolution Torque Limit Torque Accuracy Accel/Decel Time V/F Curve Frequency Control Signal Braking Torque Motor Protection Over Current Protection Ground Current Leakage Protection Over-Load Ability Voltage Protection 220V/440V Over-Voltage Protection for the Input Power Over-Temperature Protection Momentary Power Loss Enclosure type Ambient Temperature Storage Temperature Humidity Vibration Cooling System Installation Location 460V Class 007 015 022 037 055 075 110 150 185 220 300 370 450 0.7 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 1 3.0 3.8 2.3 2 4.2 3 6 5 8.5 10 7.5 13 16 10 18 22 15 24 30 20 32 40 24 25 38 47 29 30 45 56 40 60 75 50 73 91 60 91 113 550 55 75 110 138 84 750 75 100 150 188 114

Output Rating

5.3 7.5

3.2 4.6 6.5 9.9 13.7 18

34 45.7 55.6 69.4

3-phase 380~460V proportional to the input voltage 380/400/415/460 VAC 3 phase, 50/60 Hz 340~500VAC, 47~63 Hz 4.0 5.7 7.3 9.9 12.2 17.2 23 38 55 56 60 73 91 130 175 1. Vector Control; 2. Torque Control; 3. V/F Control Starting Torque is 150% at 0.5Hz and above. 1:100 Sensorless Vector (1:1000 when using PG card and encoder feedback) 0.5% Sensorless Vector (0.02% when using a PG card and encoder feedback) 5Hz (connect externally with PG to achieve 30Hz) 0.00 to 400.00 Hz Digital Command: 0.005%, Analog Command: 0.5% Digital Command: 0.01Hz, Analog Command: 1/1000 (10bit) of the maximum output frequency Maximum allowable torque is 200% 5% 0.00~600.00/0.1~6000.0 sec Adjustable V/F curve using 4 independent points. 0-10V, -10-+10V, 4-20mA, Square wave pulse input Approx. 20% Electronic thermal relay protection The current forces 220% of the over-current protection and 300% of the rated current Current Leakage Protection: 50% peak value rated current Constant/Variable 150% for 60 seconds; 200% for 2 seconds Over-voltage level: Vdc>400/800 V; low-voltage level: Vdc<200/400 V Varistor (MOV) Built-in temperature sensor 5 second maximum time setting NEMA 1/IP21 -10 ~40 for UL & -10 ~50 for CE -20 ~60 Below 90% RH (non-condensing) Below 20hz: 1G, above 20hz: 0.6G Forced air cooling Altitude of 1,000m or less, keep away from corrosive gas, liquid, and dust.

Environment

Protection

Characteristics

Control Characteristics

Input Rating

A-2

DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED