You are on page 1of 1

Technical data 1500 kWel; 415 V, 50 Hz; Acc.

to gas analysis Design conditions


Comb. air temperature / rel. Humidity: Altitude: Exhaust temp. after heat exchanger: NOx Emission (tolerance - 8%): [C] / [%] [m] [C] [mg/Nm3] 35 / 80 100 120 500

Fuel gas data:

2)

Methane number: Lower calorific value: Gas density: Analysis: CO2 N2 O2 H2 CO CH4 C2H6 C3H8 C4H10 CxHy H2S

[-] [kWh/m3] [kg/Nm3]


Acc. to gas analysis

90 10,17 0,74 0,11 0,3 0 0 0 97,33 1,72 0,35 0,13 0,06 0

Genset:
Engine: Speed: Configuration / number of cylinders: Bore / Stroke / Displacement: Compression ratio: Mean piston speed: Mean lube oil consumption at full load: Engine-management-system: Generator: Voltage / voltage range / cos Phi: Speed / frequency: TCG2020V16K [1/min] [-] [mm]/[mm]/[dm3] [-] [m/s] [g/kWh] [-] 1500 V / 16 170 / 195 / 71 12 9,8 0,2 TEM EVO

[Vol%] [Vol%] [Vol%] [Vol%] [Vol%] [Vol%] [Vol%] [Vol%] [Vol%] [Vol%] [Vol%]

Marelli MJB 500 MC4 [V] / [%] / [-] 415 / 5 / 1 [1/min] / [Hz] 1500 / 50

Energy balance
Load: Electrical power COP acc. ISO 8528-1: Engine jacket water heat: Intercooler LT heat: Lube oil heat: Exhaust heat with temp. after heat exchanger: Exhaust temperature: Exhaust mass flow, wet: Combustion mass air flow: Radiation heat engine / generator: Fuel consumption: Electrical / thermal efficiency: Total efficiency: [%] [kW] [kW 8%] [kW 8%] [kW 8%] [kW 8%] [C] [kg/h] [kg/h] [kW 8%] [kW +5%] [%] [%]
1)

100 1500
740 163 987 497 8618 8349 54 / 40 3691 40,6 / 46,8 87,4

75 1125
575 110 810 524 6578 6369 52 / 33 2864 39,3 / 48,4 87,7

50 750
419 63 596 551 4520 4374 49 / 28 2014 37,2 / 50,4 87,6

System parameters
Ventilation air flow (comb. air incl.) with T = 15K Combustion air temperature minimum / design: Exhaust back pressure from / to: Maximum pressure loss in front of air cleaner: Zero-pressure gas control unit selectable from / to: 2) Pre-pressure gas control unit selectable from / to: 2) Starter battery 24V, capacity required: Starter motor: Lube oil content engine / base frame: Dry weight engine / genset:

[kg/h] [C] [mbar] [mbar] [mbar] [bar] [Ah] [kWel.] / [VDC] [dm3] [kg]

39700 25 / 35 30 / 50 5 20 / 200 0,5 / 10 430 15 / 24,0 265 / 6090 / 12600

Cooling system
Glycol content engine jacket water / intercooler: Water volume engine jacket / intercooler: KVS / Cv value engine jacket water / intercooler: Jacket water coolant temperature in / out: Intercooler coolant temperature in / out: Engine jacket water flow rate from / to: Water flow rate engine jacket water / intercooler: Water pressure loss engine jacket water / intercooler: [% Vol.] [dm3] [m3/h] [C] [C] [m3/h] [m3/h] [bar] 0/0 151 / 20 46 / 30 82 / 93 40 / 45 50 / 65 60 / 30 1,6 / 1,0

1) See also "Layout of power plants":

2) See also Techn. Circular 0199-99-3017

Engine noise level


63 125 250

Octave band centre frequency


500 1000 2000 4000 8000

Sum level
(distance 1 meter)

Exhaust noise
[dB(lin)]

119 92

128 96

120 98

117 97

116 99

115 97

112 96

107 98

122 dB(A) (2,5 dB(A)) 104 dB(A) (1,0 dB(A))

Air-borne noise
[dB(lin)]