You are on page 1of 3

ULHAS VAJRE AND ASSOCIATES BEE CERTIFIED ENERGY AUDITORS

MISSION To provide our clients with measurable and significant productivity gains through excellence in Energy Auditing, Energy Management and Technology Training.

1. Methodology A visit for a typical energy audit takes about three to Four weeks for our team depending on the si!e of the plant and the inclusions and exclusions which are plant specific". #uring the visit, all the data collection, measurements with our own set of instruments" performance test of critical e$uipment and preliminary analysis are completed. At the end of the audit, preliminary observations about the saving potential in various areas is discussed and presented to the client. !. "HAT "E ARE GOING TO DO AND HO" IT "ILL BENEFIT CLIENTS 1. Ele#t$%#&l D%'t$%()t%o* Net+o$, - U'&ge a" Transformers% &erformance evaluation through measurement of ma'or electrical parameters on (.T. and ).T. side and rationali!ation of transformer loading if re$uired. )osses on Transformers and * )oading" b" &ower Factor% Measurement of distortion and displacement power factor at various points vi!. &++, M++, )oad centers etc. and analysis of the same for optimi!ing the network losses. c" Metering and Monitoring ,tatus% -eview of existing meters for ade$uate monitoring re$uirements. d" Electricity .ills% ,tudy of present consumption pattern and recommendations for optimi!ation. e" Measure voltage drop in various feeders and improvement proposal. f" Measure Motors and measure * of loading and performance efficiency g" Measure rated /utput and rated 0nput and * loading h" 0dentify grossly under loaded motor for replacement of the same with EE motor. !. L%ght%*g' a" Measurement of 0llumination efficacy and -oom 0ndex as per latest standards lighting system Energy Efficiency study along with population of lightings" b" Management of light intensity and all ma'or electrical parameters vi!. 1oltage, amp. &.F. 23 etc. c" Measure Existing setup and propose EE lighting. ,tudy of type of lamps used, type of chokes used, day and night time lighting etc

.. "&te$ /)01' a" Evaluation of performance with respect to head 4 pressure, flow, power consumption of pumps. Measure actual (ead and rated head with respect to flow b" &ump efficiency. ,tudy present system with respect to flow, re$uirement and losses. 5 A%$ Co01$e''o$' %2 &*y

a" Measure compressor performance. #etermination of compressor capacities 1olumetric efficiency FA# Test" and specific power consumption. 23 4 +FM" b" )oad on +ompressor motors * loading" c" ,tudy of pressure loss for main circuits. &ressure drops" d" * )eakage in your system )EA2A6E TE,T". )eakage detection and $uantification of your plant 4 factory leakage in terms of 23 (r 7nits loss. 0dentification of leakage points through our 7ltrasonic )eak detector instrument. 3. Cool%*g To+e$' a" Measure +ooling Tower &erformance. Evaluation of cooling performance by measurement of water flow, inlet4outlet temperatures and ambient air #.T43.T, air flow, fan power etc. b" Measure cooling Tower Effectiveness. +o8relation of cooling tower performance with due consideration of cooling water system as a whole. c" Efficient system operation

4. F)$*&#e' 5 O6e*' %2 &*y a" Furnace efficiency in #irect Method b" Measurement of various losses like sensible heat loss in flue gas, (eat loss due to openings, (eat loss through furnace skin, unaccounted losses etc. c" -adiation heat loss, 3all losses etc. 7. HVAC 5 CHILLING /ALNT a" &erformance assessment of -efrigeration4 +hilling efficiency levels and +oefficient of &erformance. b" ,pecific &ower consumption k3 4 T-. c" &ossibilities of optimi!ation of refrigeration 9 A4+ load. 8. F&*' &*d Blo+e$' a" Evaluation of performance with respect to head4pressure, flow, power consumption of blowers. b" .lower &erformance and efficiency c" +alculation of 1elocity &ressure, 1elocity, Air density etc 9. D G Set 'y'te0 a" )oad pattern, load +haracteristics and #6 set capacity. &lant. Establishing present

b" Establish present performance levels. 1: . He&t e;#h&*ge$' % )0M0TE# T/ T3/ :7M.E- (EAT E;+(A:6E- /:)< a" (eat exchanger &erformance Assessment = /verall (eat transfer co efficient, effectiveness, )MT# etc.

3e trust our scope of work mentioned above is in line with your re$uirement, we are looking forward to receive your valued orders. ,hould you have any $ueries, please feel free to contact us. Thanking and assuring of our prompt and best services always <ours sincerely,

ULHAS VAJRE +ertified Energy Auditor -egn :o% EA =5>?>" +ertified by .ureau of Energy Efficiency to practice as Energy Auditor and Energy Manager under the E+ Act, @AAB

You might also like