You are on page 1of 6

HW II Power Control Data Table

PC Interval
Range: 1~15
Unit SACCH period (480ms)
Default: 4
Description: The minimum interval between 2 continuous power control commands.

Filter Length for UL RX_LEV
Range: 1~20
Unit -
Default: 6
Description: Indicates the number of MRs to be used for uplink power control judgement of the
uplink signal strength.


Filter Length for DL RX_LEV
Range: 1~20
Unit -
Default: 6
Description: Indicates the number of MRs to be used for downlink power control judgment of the
downlink signal strength.

Filter Length for UL Qual.
Range: 1~20
Unit -
Default: 6
Description: Indicates the number of MRs to be used for downlink power control judgment of the
uplink signal quality.



Filter Length for DL Qual.
Range: 1~20
Unit -
Default: 6
Description: Indicates the number of MRs to be used for downlink power control judgment of the
downlink signal quality.


MR. Compensation Allowed
Range: Yes/ No
Unit -
Default: Yes
Description: During the power control judgment, consideration should be given to the impact of
different transmitting power levels on the receiving signal strength. When the value
of this parameter is "Yes", the currently received MR will be placed into the MR
compensation queue. Then, according to the recorded information about MS and
BTS power changes, the receiving signal strength of the MR is compensated.

UL MR. Number Predicted
Range: 0~3
Unit number of MRs
Default: 2
Description: The number of uplink MRs to be predicted. In HW_II PC algorithm, the future
receiving signal strength will be predicted so as to counteract the impact of the
power control hysteresis.

DL MR. Number Predicted
Range: 0~3
Unit number of MRs
Default: 2
Description: The number of downlink MRs to be predicted. In HW_II PC algorithm, the future
receiving signal strength will be predicted so as to counteract the impact of the
power control hysteresis.

UL RX_LEV Upper Thrsh .
Range: 0~63 (-110dBm~-47dBm)
Unit Grade
Default: 35
Description: The upper threshold of uplink receiving signal strength. In HW_II PC algorithm, the
power control threshold includes upper threshold and lower threshold. Only when
the receiving signal strength exceeds the range between the upper threshold and
lower threshold, will the power control be performed. When the receiving signal
strength exceeds the range between upper threshold and lower threshold, the power
adjustment value = (UL RX_LEV upper Thrsh. + UL RX_LEV lower Thrsh.)/2- the
receiving level. This adjustment value works together with the MAX Adj. value for
Qual. zone 0/1/2 to determine the actual power adjustment step.

UL RX_LEV Lower Thrsh .
Range: 0~63, (-110dBm~-47dBm)
Unit Grade
Default: 25
Description: The lower threshold of uplink receiving signal strength. See the description of "UL
RX_LEV upper Thrsh"

UL Qual. Upper Thrsh.
Range: 0~7
Unit Grade
Default: 0
Description: The upper threshold of uplink receiving signal quality. In HW_II PC algorithm, the
power control threshold includes upper threshold and lower threshold. Only when
the receiving signal quality exceeds the range between the upper threshold and
lower threshold, will the power control be performed.

UL Qual. Lower Thrsh.
Range: 0~7
Unit Grade
Default: 2
Description: The lower threshold of uplink receiving signal quality. In HW_II PC algorithm, the
power control threshold includes upper threshold and lower threshold. Only when
the receiving signal quality exceeds the range between the upper threshold and
lower threshold, will the power control be performed.

DL RX_LEV Upper Thrsh .
Range: 0~63, (-110dBm~-47dBm)
Unit Grade
Default: 40
Description: The upper threshold of downlink receiving signal strength. In HW_II PC algorithm,
the power control threshold includes upper threshold and lower threshold. Only
when the receiving signal strength exceeds the range between the upper threshold
and lower threshold, will the power control be performed. When the receiving signal
strength exceeds the range between upper threshold and lower threshold, the power
adjustment value = (DL RX_LEV upper Thrsh. + DL RX_LEV lower Thrsh.)/2- the
receiving level. This adjustment value works together with the MAX Adj. value for
Qual. zone 0/1/2 to determine the actual power adjustment step.

DL RX_LEV Lower Thrsh .
Range: 0~63, (-110dBm~-47dBm)
Unit Grade
Default: 30
Description: The lower threshold of downlink receiving signal strength. See the description
of "DL RX_LEV upper Thrsh.".

DL Qual. Upper Thrsh.
Range: 0~7
Unit Grade
Default: 0
Description: The upper threshold of downlink receiving signal quality. In HW_II PC algorithm,
the power control threshold includes upper threshold and lower threshold. Only
when the receiving signal quality exceeds the range between the upper threshold and
lower threshold, will the power control be performed.

DL Qual. Lower Thrsh.
Range: 0~7
Unit Grade
Default: 2
Description: The lower threshold of downlink receiving signal quality. See the description
of "DL Qual. upper Thrsh.".

MAX Down Adj. value Qual. zone 0
Range: 0~30
Unit dB
Default: 4
Description: The maximum downward power adjustment value for quality zone 0. In HW_II PC
algorithm, the receiving signal quality is divided into three quality zones (0, 1~2,
3), and different maximum downward power adjustment steps are set for each
zone. In the power adjustment according to the receiving signal strength,
consideration should be given to the maximum step adjustment for each zone.

MAX Down Adj. value Qual. zone 1
Range: 0~30
Unit dB
Default: 4
Description: The maximum downward power adjustment value when RQ value is 1 or 2.

MAX Down Adj. value Qual. zone 2
Range: 0~30
Unit dB
Default: 4
Description: The maximum downward power adjustment value when RQ 3.

MAX Down Adj. PC Value by Qual.
Range: 0~4
Unit dB
Default: 4
Description: The adjustment step allowed for the downward power control due to receiving
signal quality.
Note In HW_II PC algorithm, the power adjustment request bases on the receiving signal
strength and the receiving signal quality. Then the power control adjustment
direction and step are obtained by combining the two, as shown as follow table.
MAX Up Adj. PC Value by RX_LEV
Range: 0~32
Unit dB
Default: 16
Description: It is used to set the maximum adjustment step for upward power control by receive
level.
Note: 1) BTS3X macro cellular: G3BTS32.30000.04.1130 and later version support the
function that the upward adjustment step and the upward adjustment step is
processed respectively; support bad receive quality power control. Other versions do
not support bad receive quality power control and the upward adjustment step and
the downward adjustment step is processed as the downward adjustment step.
2) BTS3002C: G3BTS36.30000.03.0820and later version support the function that
the upward adjustment step and the upward adjustment step is processed
respectively; support bad receive quality power control. Other versions do not
support bad receive quality power control and the upward adjustment step and the
downward adjustment step is processed as the downward adjustment step.
3) Other type sites: all versions do not support the function that the upward
adjustment step and the upward adjustment step is processed respectively; do not
support bad receive quality power control.

MAX Up Adj. PC Value by Qual.
Range: 0~32
Unit dB
Default: 8
Description: It is used to set the maximum adjustment step for upward power control by receive
quality.
Note: 1) BTS3X macro cellular: G3BTS32.30000.04.1130 and later version support the
function that the upward adjustment step and the upward adjustment step is
processed respectively; support bad receive quality power control. Other versions do
not support bad receive quality power control and the upward adjustment step and
the downward adjustment step is processed as the downward adjustment step.
2) BTS3002C: G3BTS36.30000.03.0820and later version support the function that
the upward adjustment step and the upward adjustment step is processed
respectively; support bad receive quality power control. Other versions do not
support bad receive quality power control and the upward adjustment step and the
downward adjustment step is processed as the downward adjustment step.
3) Other type sites: all versions do not support the function that the upward
adjustment step and the upward adjustment step is processed respectively; do not
support bad receive quality power control.
PC adjustment of
receiving signal
strength
PC adjustment of
receiving signal quality
Power control adjustment combining the
receiving signal strength and quality
AdjStep_Lev AdjStep_Qul maxAdjStep_Lev,AdjStep_Qul)
AdjStep_Lev AdjStep_Qul No action
AdjStep_Lev No action AdjStep_Lev
AdjStep_Lev AdjStep_Qul AdjStep_Lev
AdjStep_Lev AdjStep_Qul max(AdjStep_Lev,AdjStep_Qul)
AdjStep_Lev No action AdjStep_Lev
No action AdjStep_Qul AdjStep_Qul
No action AdjStep_Qul AdjStep_Qul
No action No action No action
BTS PC class
Range: 1~16; corresponding to 0dB~30dB
Unit: grade
Default: 16
Description: The maximum range of BTS dynamic power control adjustment.
Note: For versions before BTS24 06.1111/ BTS3X 03.1130/ BTS3001C 07.0301/
BTS3002C 02.0820, this parameter must be set as 2~16 when BTS is configured
with MR pre-processing and G-II power control. Otherwise, error will occur in TRX
configuration flow. For versions mentioned above and the subsequent versions, this
parameter can be set as 1~16.