You are on page 1of 6

132

Chemical and
Respiratory
Protective Suits
Type 4 suits are designed provide the workers with a high level
of protection against hazardous dusts/particulates and sprays of
certain liquid chemicals, for example in decontamination showers
and infection control.
Type 3 suits are designed to provide workers in both industrial
and Emergency Response environments with a high level of
personal protection against a broad range of industrial chemicals
and other agents found in Civil Emergency situations.
Both of these systems combine highly comfortable protective
suits with respiratory protection from the industry proven
3M
TM
Jupiter
TM
JP-ER-03 Powered Air Purifying Turbo.
Emergency Response personnel have unique needs from the
Personal Protective Equipment (PPE) they wear which are
diferent from industrial workers:
they are in emergency rather than routine situations +
there may be a wide range of hazards against which +
they need protection
they do not use the PPE everyday. +
Therefore, they often need PPE specically designed to meet
these needs.
Purpose-designed, integrated PPE solutions protecting
you in the harshest environments
The 3M JS-Series Chemical and Respiratory Protective Suits (CRPS) with temperature and
altitude correction technology allow you to use these systems in almost all geographies.
10_PC12_Emergency.indd 132 05-10-2011 13:19:52
133
3M JS-Series CRPS Features
There is no compromise on t or comfort thanks to the purpose-
designed suit and turbo combination system. The loose-tting
hood design provides full coverage and protection without the
need for a tight-tting facepiece meaning that the suit can be
used by people with facial hair, face-t testing is not required,
training needs are reduced and there is a reduced sense of
claustrophobia. The clear, wide viewing visor provides an
excellent eld of view and better focus on the task in hand. 3Ms
unique Head-Up-Display gives the user constant feedback from
the system in terms of visual and audible warnings and alarms.

3M Jupiter Features
Software programmed to alert you every hour the turbo has been
running with an audible beep allows you to get on with the job
and not worry about air ow calibration. There are a full range of
Jupiter lters available to suit the majority of applications and
hazards. The Jupiter turbo ofers an ideal air supply with the
minimum air ow rate of 150 liters per minute.
10_PC12_Emergency.indd 133 05-10-2011 13:19:55
134
Solutions
3M

Emergency Response
Features, Advantages and Benets
Approved to EN12941 TH3, with a Nominal +
Protection Factor (NPF) of 500
Additional testing to EN1073-1 gives and NPF +
of 2000 meaning that these suits can be used
to provide respiratory protection up to 2000
times the Threshold Limit Value (TLV)*
New comfort back harness allows for easier +
driving of vehicles and ensures ideal weight
distribution of x turbo and lters.
Type 3 Protective Suit with taped seams for +
protection against liquid chemical hazards
(tested under jet pressure)
Factory calibrated turbo to allow you to just get +
on with the job and not worry about air ow
calibration

Integrated Nitrile gloves welded to the suit so +
you dont have to spend time worrying about
getting an efective seal.

3Ms unique air exhaust positioning means air +
must pass over the whole body to exit the suit
through an active elastomeric exhaust valve.
This provides a cool airstream which improves
comfort, reduces heat stress, allows for better
focus on tasks and for longer wearing times.

Integrated sock (same material as suit) to allow +
wearer choice in footwear and added security
of boot ap to help prevent contamination of
the footwear.
* Additional testing, to EN 1073-1:1998 demonstrated that a Total Inward
Leakage (Respiratory Zone of less than 0.05% was achieved, relating
to a Nominal Respiratory protection factor of 2000 for all suits. Inward
leakage of whole suit design meets the requirement of the suit Type 5
Test, with Ljmn 82/90 =30% and Ls, 8/10
Key Applications
Mass decontamination exercises - evacuations +
Hospital rst receivers +
Emergency Medical Service (Ambulance) +
Casualty transport +
Triage +
Hazardous waste remediation +
Asbestos abatement +
Petrochemical applications +
Liquid chemical and solvent handling +
3M

JS-330 Series Chemical and Respiratory
Protective Suits (CRPS)
The 3M JS-330 Series of Type 3 Suits are designed to provide
Emergency Response workers with a high level of personal protection
against a broad range of industrial chemicals and other agents found
in Civil Emergency situations.

These systems combine robust highly comfortable Type 3 suits with
respiratory protection from the industry proven 3M Jupiter
JP-ER-03 Powered Air Purifying Turbo.
Wide viewing visor. + Comfortable, +
elasticated knitted
neck seal.
Head-Up-Display. +
10_PC12_Emergency.indd 134 05-10-2011 13:19:57
135
3M

JS-Series
Chemical and Respiratory Protective Suits (CRPS)
3M Filters and Accessories
Disclaimer
There are uses, environments and chemicals for which these garments and/
or fabrics are unsuitable. It is the responsibility of the user to review available
data and verify that the garment and/or fabric is appropriate for the intended
use and meets all specied government industry standards.
Item Description Pack Qty
Suits
JS-330 SUIT Type 3 broad range chemical protection suit 1
JS-470 SUIT Type 4/5 Lightweight suit, without integrated gloves 4
JS-470G SUIT Type 4/5 Lightweight Suit with integrated gloves 4
Turbo
JP-ER-03 Turbo Kit Turbo, Backpack, Head-Up Filter Retainers Display and Breathing Tube 1
Batteries
BAT-22 Single Use 4-Hr Battery 1
007-00-63P Rechargeable 4-Hr Battery 1
007-00-64P Rechargeable 8-Hr Battery 1
Filters
450-00-25P2 Particulate P R Filters (Pairs) 12
453-00-25P2 A2P R Filters (Pairs) 6
453-09-25P2 A2BEK1P R Filters (Pairs) 6
453-16-25P2 K1P R Filters (Pairs) 6
456-18-25P2 ABE1P R Filters (Pairs) 6
JFR-85 ABEK2P R (Pairs) 6
Spares & Accessories
BPK-01 Back Pack 1
008-00-42P3 / BT-20L Breathing Tube 3
003-00-58P Intelligent Battery Charger 1
003-00-59P Intelligent 10-Station Battery Charger 1
10_PC12_Emergency.indd 135 05-10-2011 13:19:59
136
3M

JS-470/JS-470G Series
Chemical and Respiratory Protective Suits (CRPS)
The 3M JS-470 Series of Type 4/5 Suits are designed to provide
workers in pharmaceutical, hospital and veterinary environments with a
high level of personal protection against a broad range of biological and
particulate hazards.
These systems combine highly comfortable Type 4/5 suits with
respiratory protection from the industry proven 3M Jupiter
JP-ER-03 Powered Air Purifying Turbo.
Features, Advantages and Benets
Type 4/5 Protective Suit with taped seams +
3Ms unique Head-Up-Display gives the user +
constant feedback from the system in terms of
visual and audible warnings and alarms
Factory calibrated turbo to allow you to just get +
on with the job and not worry about air ow
calibration
Approved to EN12941 TH3, with a Nominal +
Protection Factor (NPF) of 500.
Additional testing to EN1073-1 gives an NPF +
of 2000*
The clear wide viewing visor provides excellent +
eld of view and better focus on the task in
hand.
Comfortable, elasticated knitted neck seal. +
Centre closing zip helps speed up the donning +
and dof ng of the suit.
3Ms air exhaust positioning means air must +
pass over the whole body to exit the suit
through an active elastomeric exhaust valve.
This provides a cool airstream which may
improve comfort, reduces heat stress, allow for
better focus on tasks and for longer wearing
times.
Fully encapsulated over boots so no sealing +
around boots required.
Key Applications
Manufacturing of Medicines +
Laboratories +
Infection Control +
Contact with infectious agents e.g. H1N1 +
inuenza virus
Medical and Healthcare +
Agriculture +
3M

Individual
Systems
* Additional testing, to EN 1073-1:1998 demonstrated that a Total Inward
Leakage (Respiratory Zone of less than 0.05% was achieved, relating
to a Nominal Respiratory protection factor of 2000 for all suits. Inward
leakage of whole suit design meets the requirement of the suit Type 5
Test, with Ljmn 82/90 =30% and Ls, 8/10
3M conductive strip can ground the wearer
and the suit.
JS-470 has no gloves and elasticated cufs at
the wrists.
New comfort back harness allows for easier
driving of vehicles and ensures ideal weight
distribution of the turbo and lters.
Integrated +
Nitrile gloves
welded to the
suit so you
dont have to
spend time
worrying
about getting
an efective
seal (only on
JS-470G).
10_PC12_Emergency.indd 136 05-10-2011 13:20:01
137
3M

JS-Series Chemical and


Respiratory Protective Suits (CRPS)
3M Filters and Accessories
Item Description Pack Qty
Suits
JS-330 SUIT Type 3 broad range chemical protection suit 1
JS-470 SUIT Type 4/5 Lightweight suit, without integrated gloves 4
JS-470G SUIT Type 4/5 Lightweight Suit with integrated gloves 4
Turbo
JP-ER-03 Turbo Kit Turbo, Backpack, Head-Up Filter Retainers Display and Breathing Tube 1
Batteries
BAT-22 Single Use 4-Hr Battery 1
007-00-63P Rechargeable 4-Hr Battery 1
007-00-64P Rechargeable 8-Hr Battery 1
Filters
450-00-25P2 Particulate P R Filters (Pairs) 12
453-00-25P2 A2P R Filters (Pairs) 6
453-09-25P2 A2BEK1P R Filters (Pairs) 6
453-16-25P2 K1P R Filters (Pairs) 6
456-18-25P2 ABE1P R Filters (Pairs) 6
JFR-85 ABEK2P R (Pairs) 6
Spares & Accessories
BPK-01 Back Pack 1
008-00-42P3 / BT-20L Breathing Tube 3
003-00-58P Intelligent Battery Charger 1
003-00-59P Intelligent 10-Station Battery Charger 1
Disclaimer
There are uses, environments and chemicals for which these garments and/or fabrics are unsuitable. It is the responsibility of the
user to review available data and verify that the garment and/or fabric is appropriate for the intended use and meets all specied
government industry standards.
10_PC12_Emergency.indd 137 05-10-2011 13:20:03